STUDY OF BUILDING REGULATIONS 1 NITIN THAKRAL 13025006017 B. Arch V Semester

Study of building regulation

Embed Size (px)

Citation preview

Page 1: Study of building regulation

1

STUDY OF BUILDING REGULATIONS

NITIN THAKRAL 13025006017B. Arch V Semester

Page 2: Study of building regulation

2

Page 3: Study of building regulation

3

Page 4: Study of building regulation

4

Page 5: Study of building regulation

5

Page 6: Study of building regulation

6

Page 7: Study of building regulation

7

Page 8: Study of building regulation

8

Page 9: Study of building regulation

9

Page 10: Study of building regulation

10

Page 11: Study of building regulation

11

Page 12: Study of building regulation

12

Page 13: Study of building regulation

13

Page 14: Study of building regulation

REQUIREMENT FOR CONSTRUCTION OF A.T.M. IN RESIDENTIAL USE ZONE

THE CONSTRUCTION OF ATM CAN ONLY BE PERMITTED ONLY IN A LANDMARK WITH AREA MORE THAN 300 SQ. M.

THE MINIMUM WIDTH OF THE ROAD ON WHICH THE ATM IS LOCATED SHOULD BE MORE THAN 12 METER

MAXIMUM GROUND COVERAGE FOR ATM MUST BE 6 SQ. M. WHICH MUST ALSO BE ENCLOSED WITHIN THE BOUNDARY MAIN BUILDINGS.

EXCEPT THE COMMERCIAL AND OFFICIAL LANDMARKS IF THE CONSTRUCTION OF ATM IS PERMITTED THEN THE DEVELOPMENT CHARGE WOULD BE TAKEN AS PER THE APPLICABLE ZONING REGULATION CHARGE.

14

Page 15: Study of building regulation

15

• ANY BUILDING IN WHICH THE CONSTRUCTION OF ATM HAS BEEN PERMITTED MUST HAVE BEEN MADE BY FOLLOWING THE BYE LAWS FOR THAT BUILDING.

• THE PROCEDURE FOR THE PERMISION OF CONSRUCTION OF ATM WILL BE SAME AS PER THE SPECIAL PERMISSION PROCEDURE SPECIFIED IN ZONING REGULATION.

Page 16: Study of building regulation

16

REQUIREMENTS FOR SHOPPING MALL WILL ONLY BE PERMITTED IN COMMERCIAL OR SMALL

OR SERVICE INDUSTRY TYPE USABLE LAND. BUT BEFORE ATTAINING PERMISSION IT IS NECESSARY

THAT BUILDING SHOULD HAVE FACILITIES LIKE PROPER TRAFFIC LOAD,CIRCULLATION SPACE,PARKING,WATER SUPPLY AND DRANAGE SERVICES,SUFFICIENT POWER SUPPLY,FIRE FIGHTING SYSTEM AND SEVERAL OTHER SAFETY MEASURES.

Page 17: Study of building regulation

17

• IN SHOPPING MALL COMPLEX,COMMERCIAL SPACES LIKE SHOWROOM,RETAIL OUTLETS,HOTEL,RESTRAURANT ETC. AND ENTERTAINMENT ACTIVITIES ARE ALL PERMITTED.

• PROPOSED LANDMARK FOR SHOPPING MALL MUST BE MORE THAN 4000 SQ. M.

• MIMIMUM FRONTAGE OF THE LANDMARK ACCORDING TO THE SURFACE AREA ARE AS FOLLOWS:

S.A. OF LANDMARK MIN. FRONTAGE IN M.4000 404001 TO 15000 5015001 TO 50000 100MORE THAN 50000 200

• MIN. WIDTH OF ROAD IN FRONT MUST BE 24 M.

Page 18: Study of building regulation

18

• MINIMUM SETBACKS IN ACCORDANCE TO THE AREAS ARE :

S..A. OF LAND MARK40004001 TO 1500015001 TO 50000MORE THAN 50000

FRONT BACK SIDE 1 SIDE 2

12 60 6.0 6.015 9.0 9.0 9.018 12 12 1224 15 15 15

• THREE BASEMAENS CAN BE CONTRUCTED UPTO THE BUILDING ENVELOPE FOR PARKING SERVICES AND STORAGE WHICH WILL NOT BE CONSIDERED UNDER F.A.R.

• PERMISSION FOR MALL WILL ONLY BE GIVEN ATLEAST 100 M. DISTANCE FROM ‘CHAURAHA’

• THE ENTRY AND EXIT OF THE MALL WOULD BE GIVEN FROM SERVICE ROAD INSTEAD OF MAIN ROAD.

• BUILDING MUST BE INSTALLED WITH WATER HARVESTING

Page 19: Study of building regulation

19

SYSTEM, SOLAR WATER HEATING SYSTEM ,EARTHQUAKE RESISTANCE CONTRUCTIN AND RAMPS FOR THE PHYSICALLY CHALLEGED PEOPLE.• THE DESIGN/STRUCTURE OF SLAB SHULD BE IN

ACCORDANCE TO BEAR THE LOAD OF FIRE TENDER.

Page 20: Study of building regulation

20

REQUIREMENTS FOR AUDITORIUM OR CONVENTION CENTRE

CONSTRUCTION OF AUDITORIUM WILL ONLY BE PERMITTED UNDER THE MASTER PLAN ZONING REGULATION.

MIN. WIDH OF ROAD MUST BE 24 M. I ALREADY DEVELOPED AREAS AND 30 M. IN DEVELOPING OR NEWLY DEVELOPED AREAS.

FOR COVENTION CENTRE PROPOSED IN AREA LESS THAN 10 ACRES F.A.R. IS 2.0 ALTHOUGH FOR 10 ACRES OR MORE THAN THAT IT IS 3.0

Page 21: Study of building regulation

21

• SET BACK,PARKING AND OTHR REQUIREMENTS WILL BE ACCORDING TO THE BUILDING BYE LAWS.`

Page 22: Study of building regulation

22

REQUIREMENTS FOR SERVICE APARTMENTS

WILL ONLY BE PERMITTED INSIDE COMMERCIAL SPACE,HOTEL AND OFFICIAL/INSTITUTIONAL USE ZONES

SERVICE APARTMENTS WILL BE WELL DECORATED AND ‘SELF CONTENTED APRTMENTS’ IN WHICH KITCHEN AND PANTRY SERVICE WOULD BE AVAILABLE.

USED FOR STAYING FOR SHORT PERIOD OF TIME. MAXIMUM 20% OF THE TOTAL PERMITTED F.A.R. OF

HOTEL OR OFFICIAL BUILDING WILL BE ALLOWED FOR SERVICE APARTMENT.

DETACHED SERVICE APARTMENTS CAN BE CONSTRUCTED IN COMMERCIAL USE ZONE FOR WHICH THE BYE LAWS AND F.A.R TO BE APPILIED WOULD BE OF THAT ZONE.

Page 23: Study of building regulation

23

• IN DETACHED UNIT MAXIMUM 20% OF TOTAL FLOOR AREA CAN BE USED FOR OFFICE,CONFERENCE SERVICES,GUEST ROOM AND RETAIL OR SERVICE SHOP.