1
First Floor 0' - 0" MEZZANINE 15' - 8" Basement -15' - 8" T.O. STEEL 30' - 4" A B C D F G H I E Top of Parapet 32' - 10" 2.5" X 5" RECTANGULAR MULLION INSULATED TINTED GLASS SET IN ALUMINUM. PRECAST CONCRETE PANEL 12" X 42" CONCRETE TRENCH FOOTING 8' GLASS CANOPY SET IN ALUMNI CANOPY HEIGHT 13' 5" PRECAST CONCRETE SEAM NORTH ELEVATION SCALE: 1/8" = 1'- 0" POURED CONCRETE FOUNDATION WALL HVAC ROOF SCREEN HVAC ROOF SCREEN 1 A-5 - --- - --- CAP FLASHING 55' - 4 1/2" 2' - 6" 14' - 8" 15' - 8" 15' - 8" 5/8" DRAIN TILE 5/8" DRAIN TILE 4' 0' X 4' 0' X 12 CONCRETE COLUMN FOOTING CAP FLASHING 4' - 0" 8' - 0" 8' - 0" 2' - 0" 3' - 0" FIXED 36 X 24 INSULATED GLASS SLOPE ROOF GRADE First Floor 0' - 0" MEZZANINE 15' - 8" Basement -15' - 8" T.O. STEEL 30' - 4" A B C D F G H I E Top of Parapet 32' - 10" INSULATED GLASS SET IN ALUMINUM. 18' WIDE GLASS CANOPY SET IN ALUMINUM. PRECAST CONCRETE PANEL 18' X12' PANEL AUTO. SLIDING DR. GLASS- MARVIN-IG LOW E II HVAC ROOF SCREEN 12' X 42" CONCRETE TRENCH FOOTING 2.5" X 5" RECTANGULAR MULLION PRECAST CONCRETE JOINT SOUTH ELEVATION SCALE: 1/8" = 1'- 0" POURED CONCRETE FOUNDATION WALL HVAC ROOF SCREEN 1 A-5 GRADE - --- - --- 54' - 0" 15' - 8" 15' - 8" 14' - 8" 2' - 6" 4' 0' X 4' 0' X 12 CONCRETE COLUMN FOOTING 5/8" DRAIN TILE GRADE GRADE 5/8" DRAIN TILE 8' GLASS CANOPY SET IN ALUMNI CANOPY HEIGHT 13' 5" CAP FLASHING 8' - 0" 8' - 0" 4' - 0" ROOF SLOPE CAP FLASHING 8' - 0" 8' - 0" 9' - 0" 12' - 0" 1' - 6" Drawn By: Veronica Todd Checked By: Professor Goldsmith ANGUARD ESIGN 26899 LAMUERA FARMINGTON HILLS, MI 48334 248-997-8700 0FFICE 248-997-8701 FAX Approved By: Project Title Sheet Name: Interior Elevation Large Conference Room Preliminary: Final: Complete: Sheet Number Submittal Market Place AG1.6 03/01/12 1/8" = 1'-0" 1 South 1/8" = 1'-0" 2 North

Cantoro market bldg system 2 sheet - ag1-6 - north-west elevation

Embed Size (px)

Citation preview

Page 1: Cantoro market bldg system 2   sheet - ag1-6 - north-west elevation

First Floor0' - 0"

MEZZANINE15' - 8"

Basement-15' - 8"

T.O. STEEL30' - 4"

A B C D F G H IE

Top of Parapet32' - 10"

2.5" X 5" RECTANGULARMULLION

INSULATED TINTED GLASSSET IN ALUMINUM.

PRECAST CONCRETEPANEL

12" X 42" CONCRETETRENCHFOOTING

8' GLASS CANOPYSET IN ALUMNICANOPY HEIGHT 13' 5"

PRECAST CONCRETESEAM

NORTH ELEVATIONSCALE: 1/8" = 1'- 0"

POUREDCONCRETEFOUNDATION WALL

HVAC ROOF SCREENHVAC ROOF SCREEN

1A-5

----

----

CAP FLASHING

55' -

4 1

/2"

2' -

6"14

' - 8

"15

' - 8

"15

' - 8

"

5/8" DRAIN TILE

5/8" DRAIN TILE

4' 0' X 4' 0' X 12CONCRETE COLUMNFOOTING

CAP FLASHING

4' -

0"8'

- 0"

8' -

0"

2' -

0"

3' - 0"

FIXED 36 X 24INSULATEDGLASS

SLOPEROOF

GRADE

First Floor0' - 0"

MEZZANINE15' - 8"

Basement-15' - 8"

T.O. STEEL30' - 4"

ABCDFGHI E

Top of Parapet32' - 10"

INSULATEDGLASSSET INALUMINUM.

18' WIDE GLASSCANOPY SET INALUMINUM.

PRECAST CONCRETE PANEL

18' X12' PANELAUTO. SLIDINGDR. GLASS-MARVIN-IG LOWE II

HVAC ROOF SCREEN

12' X 42" CONCRETETRENCH FOOTING

2.5" X 5"RECTANGULARMULLION

PRECAST CONCRETEJOINT

SOUTH ELEVATIONSCALE: 1/8" = 1'- 0"

POURED CONCRETEFOUNDATION WALL

HVAC ROOF SCREEN

1A-5

GRADE

----

----

54' -

0"

15' -

8"

15' -

8"

14' -

8"

2' -

6"

4' 0' X 4' 0' X 12CONCRETE COLUMNFOOTING

5/8" DRAIN TILE

GRADE

GRADE

5/8" DRAIN TILE

8' GLASS CANOPYSET IN ALUMNICANOPY HEIGHT 13' 5"

CAP FLASHING

8' -

0"8'

- 0"

4' -

0"

ROOF SLOPECAP FLASHING

8' -

0"8'

- 0"

9' -

0"

12' -

0"

1' -

6"

Drawn By: Veronica Todd

Checked By:Professor Goldsmith

ANGUARD

ESIGN

26899 LAMUERAFARMINGTON HILLS, MI48334248-997-8700 0FFICE248-997-8701 FAX

Approved By:

Project Title

Sheet Name: InteriorElevation Large ConferenceRoom

Preliminary:

Final:

Complete:

Sheet Number

Submittal

Market Place

AG1.6

03/01/12

1/8" = 1'-0"1 South

1/8" = 1'-0"2 North