Chromatographic Analysis of Natural Gas Liquids Ben James President, Petrochemical Services Sherry Laboratories

Chromatographic Analysis of Natural Gas Liquids, sherry petrochemical

Embed Size (px)

Citation preview

Chromatographic Analysis of Natural Gas Liquids

Ben James

President, Petrochemical Services

Sherry Laboratories

Who is Sherry Laboratories

• Founded in 1947, an industry leader in independent, third-party testing

• 10 laboratories

• Accredited testing

• Technical expertise

• Mission critical

Sherry Environmental Testing

Sherry Petrochemical Testing & Standards

Manufacturing

Sherry Materials Testing

Sherry Engineering Group

Sherry Microbiological & Food Testing

Sherry Subsidiaries

Hydrocarbon Lab

• Serves industries such as:– Natural Gas Production– Gas Transmission Pipeline– Drilling and Exploration– Liquid Hydrocarbon

Fractionation

• Provides services such as:– Gas Analysis– Liquid Analysis– Condensate Analysis– Sulfur and Mercaptans– Extended Analysis– Flash and Shrink Test

Reference Standards

• Serves industries such as:– Natural Gas Production– Gas Transmission Pipeline– Drilling and Exploration– Liquid Hydrocarbon

Fractionation

• Provides products such as:– Natural Gas Blends– GPA and Custody Transfer

Chromatographic Standards– Petrochemical Mixtures– Refinery Gas Mixtures– On-line Chromatograph

Calibration Gas

Analytical Methods

• GPA 2177– “Method for the Analysis of Demethanized Hydrocarbon

Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography”

• GPA 2186– “Method for the Extended Analysis of Hydrocarbon Liquid

Mixtures Containing Nitrogen and Carbon Dioxide by Temperature Programmed Gas Chromatography”

Composite Sampler

• Sample Probe

– Center 1/3 of Pipe

– Not located in dead-end or recirculation area

• Tubing to Pump

– Small Enough to Ensure That a Fresh, Representative Sample is at the Pump Suction Prior to Each Stroke

– High Pressure, Low Temperature

Composite Sampler

• Sample Pump– Flow Proportional

– Repeatable Volume

• Sample Accumulator– Floating Piston Type

– Mixer

– Sufficient Back Pressure

– Choose Back Pressure Gas Carefully

– Never Fill More than 80%

Transport Cylinder

Transport Cylinder

Sampling

• Mix Well

• Adequate Purging

• Transfer under Pressure

• Check For Leaks

• 80% Maximum

• D.O.T Regulations

Typical AutomaticSampling System

From the PipelineTo the Chromatograph

• 500,000 barrels

• To 15,000 cc

• To 1/2 microliter

• Less than 1 part in 150,000,000,000,000

• Sample Must be Representative of the Product Pumped

Chromatograph Systems

• Sample injection system

• Pressure, Flow and Temperature Control

• Columns

• Detectors

• Integrator or Computer Systems

• Calibration

• Calculations

The Chromatograph

Sample Injection

• Pressurize Inert Gas Side of Sample Cylinder

• Mix Sample

• Connect Product Side to Sample System

• Shut Purge / Block Valve

• Admit Sample to System

• Purge Slowly and Sufficiently

• Block In

• Inject Sample

Sample Injection System

Inert Gas

Purge/Block

Valve(s)

Carrier Gas

To Chromatograph

Injector

Filter

Sample Injection System

Column

Packed Column

Capillary Column

Column

• Polar

• Non-Polar

• Temperature

• Flow

• Temperature Programming

• Combinations of Columns

Hexanes Plus

• Back Flush

• Pre Cut

• Temperature Programming

Back Flush

Pre Cut

Extended Analysis

• Hexanes Plus Fraction of Sample

– Over 100 components

• Physical Properties Depend on Mix of These Components

• Average Molecular Weight

• Average Density

Temperature Program

Temperature

Detectors

• Thermal Conductivity

• Flame Ionization

Thermal Conductivity Detector

• Universal

• Wire Filament or Bead

• Conductivity of Gas Determines Temperature of Detector Filament

• Linearity

• Sensitivity

Thermal Conductivity

Flame Ionization Detector

• More Sensitive Than TCD

• Higher Linear Range

• Not Sensitive to H2S or CO2

• Flame May Be Objectionable

Column

Effluent

Air

Hydrogen

Flame

Tip

Collector

Flame

Electrical

Signal

Detectors

TCD

FID

Integration or Computer

• Adequate separation

• Integration parameters

• Peak identification

• Calibration

Chromatogram

Calibration

• 80 Mole %

• 80,000 Counts from Integrator

• 80 / 80,000 = 0.001 Calibration Factor

• 79,000 Counts

• 79,000 x 0.001 = 79 Mole %

Evaluating Calibration Standard

• Run as an Unknown

• Outside Lab Verification

• Plot of Response Factors

• Control Charts

• GPA 2198

GPA 2177

• Chromatograph Repeatability and Reproducibility Criteria

• Revision 01/07/08

• Natural Gas Liquids

Plot

Calculations

• Industry Standards for Calculations

• Industry Standards for Physical Constants

– Latest Versions

Summary

• Good Sample to Chromatograph

• Sample Injection

• Peak Separation

• Detector Response

• Integration

• Calibration

• Calculations