Lighting Current Limiters

Supplementary circuit breakers, designed to limit available wattage

based on the actual lighting design criteria, thereby avoiding the

“watts-per-linear-foot penalty” imposed by energy codes while

maintaining track lighting density, performance and configuration

flexibility.

What is a Current Limiter

04/13/23 2

Page 3: 120330 current limiters

X

Lighting Current Limiters

• To limit the size of the electrical service

• NEC 220.43(B) requires 75W per linear foot for service calculations.

• By using current limiter you can use the track load as a typical lighting

load.

Why use Current limiters

04/13/23 3

Page 4: 120330 current limiters

X

Lighting Current Limiters

• Required by local Codes:

• California Title 24.

• City of Seattle Energy Code.

• City of Denver Energy Code.

Why use current Limiters (cont.)

04/13/23 4

• To help meet local codes:

• IEEC and ASHRAE 90.1 requires 30-watts per linear foot.

• California Title 24 requires 45-watts per linear foot.

• City of Seattle Energy Code requires 70-watts per linear foot.

Page 5: 120330 current limiters

X

Lighting Current Limiters

• Standard layout without current limiters

• 100’ of track and (32) 39W CHM (45W total fixture wattage).

• 32x45=1440W connect load.

• Using track length wattage calculations: 100x45 (based on T24)=4500W.

Example

04/13/23 5

Page 6: 120330 current limiters

X

Lighting Current Limiters

• Revised layout using short track segments without current limiters

• 64’ of track and (32) 39W CHM (45W total fixture wattage).

• 32x45=1440W connect load.

• Using track length wattage calculations: 64x45 (based on T24)=2880W.

Example (cont.)

04/13/23 6

Page 7: 120330 current limiters

X

Lighting Current Limiters

• Original layout using current limiters

• 100’ of track and (32) 39W CHM (45W total fixture wattage).

• 32x45=1440W connect load.

• Using Current limiter wattage calculations: 4x480=1920W.

Example (cont.)

04/13/23 7

Page 8: 120330 current limiters

X

Lighting Current Limiters

• Track mounted current limiters

• End Feeds, 1-ckts and 2-ckts

• In-Line Feeds, 1-ckts and 2-ckts

Types of current Limiters

04/13/23 8

Page 9: 120330 current limiters

X

Lighting Current Limiters

• Current limiting panel

• LC&D Sliver Bullet

• Current limiting for up to 12 Ckts (Mini) and up 21 ckts

• Current limiting available from 1-8, 10,13 & 15 amps (80% rated).

• Compact Sizes 12" w x 18" h x 4" d or 12″ w x 12″ h x 4″ d

Types of current Limiters (cont.)

04/13/23 9

Page 10: 120330 current limiters

X

Lighting Current Limiters

• Current limiting panel

• Cooper Greengate TracKeeeper

• Current limiting for up to 16 Ckts (Mini) and up 32 ckts

• Current limiting available: 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10, 13, 15, 16, 20, 25, 30,

32, 40, 50, 60. (80% rated)

• Available in 120V and 277V.

Types of current Limiters (cont.)

04/13/23 10

Page 11: 120330 current limiters

X

Lighting Current Limiters

• Current limiting panel

• Juno Trac-Master

• Available sizes: 1-12 Ckts (Mini), 6-21 Ckts (standard), 22-42 Ckts (large),

• Current limiting available: 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, and 13A. (80%

rated)

• Available in 120V and 277V.

Types of current Limiters (cont.)

04/13/23 11

Page 12: 120330 current limiters

X

Lighting Current Limiters

• Individual current limiter cost $50-$60

• LC&D Sliver Bullet mini panel cost approximately $2000

• Use Individual current limiter on smaller spaces like Sunglass Hut.

• Use a current limiting panel on larger stores like F21, casual male.

Current Limiter vs. Current limiting Panel

04/13/23 12