Silentium Company Profile

Preview:

Citation preview

Company Overview

Joel(Yoel) Naor, Director of Products

T: +972-8-9468664

C: +972-542-320409

F: +972-8-9468604

Email: yoel@silentium.com

www.silentium.com

2 Oct-10

The “Pain”

• Equipment/Products generate Noise

• Noise is Pollution, annoying, harmful and

reduces productivity and “Quality of Life”

• Noisy products are inferior

• Regulations

• Market demand

3 Oct-10

Silentium – Spatial & Broadband Active

Acoustic

Canceling emitted noise by counter noise

• Physics of Spatial Active Acoustics

• DSP – Proprietary Prediction Algorithms

4 Oct-10

Noise Reduction Methodology

Reduces Effectively

Low-frequency noise

Reduces Effectively

High-frequency noise

5 Oct-10

Noise Sources-Spectrum

Air flow spectrum example

Active Noise Control => effective in the low frequency band

Passive absorption => effective in the high frequency band

Broad band Noise => Requires a combination of

Passive and Active Noise Control

6 Oct-10

Technology – Silentium’s ANC

Canceling the emitted noise

at the source

Embedded in Products (OEM&ODM

oriented)

Vs.

Engineering each target zone/space

(Environment)

7 Oct-10

OEM - S-Cube™ Kit

Reference Design

8 Oct-10

Active Acoustics Fields

AVC

Active Vibration Control

S-Cube™SoC - Reference Design

ANC

Active Noise Control

ASAC

Active Structural Acoustic Control

ASAC

Active Structural Acoustic Control

9 Oct-10

Hot Swap ANC- Fan for CRAY CX1

Design Win

10 Oct-10

Blower application example

Blower

Microphone

Speaker

Inlet

11 Oct-10

ActiveSilencer™ Duct

12 Oct-10

AcoustiRACK™ Active - ARA™

• The first rack mount cabinet with ANC- reducing

fan generated noise

• Ideally designed for office environment

• Up to 30dBA reduction

13 Oct-10

- Silentium Remote Site Solution

c3000 with UPS & local KVM in a small 15U (usable) AcoustiRACK™

14 Oct-10

ASE™ for Intel® Modular Server

15 Oct-10

Business Model

Collaborations

with

OEM’s & ODM’s

16 Oct-10

Reference Design Methodology

Acoustic

Development

Mechanical Design Production phase

HW Design (based on

SILENTIUM’s Reference

Design)

S-Cube™ Controller

Gate

Silentium Provides:

1. SCDK™

2. Technical Coaching

Silentium Provides:

1. S-Cube™ Controller \ Reference Design Notes

2. Technical Coaching

Silentium Provides:

1. S-Cube Controller or Silentium

components S/W

2. SEK™ (Calibration units)

3. Technical Coaching

17 Oct-10

Silentium Products

SCK™

S-cube™ Kit

ARA™

AcoustiRACK™ Active

SCDK™

S-cube™ Development Kit

ASFT™

Active Silencer Fan

Tray

ASE™

Acoustic Silencer Enclosure

for Intel® Modular Server

18 Oct-10

The S-Barrier™ Panel

• Components:

• 2 PZTs (sensor + actuator)

• S-Chip™ microcontroller

• Panel: Aramid Honeycomb core with Epoxy Glass Fiber skin

• Thickness: 6 mm

• Weight: 2.3 Kg/m2

• Fire: Fire-resistant and self extinguishing.

• Service Temperature: -20o-90o C

The S-Barrier is aiming at reducing 10 dB(A) structure borne

noise on top of the passive reduction.

19 Oct-10

Applications

Technology/

Market

SegmentationANC ASAC Z-2-Z

Home appliances

IT

Transportation - Ventilation System -Engine noise reduction

- Road/wind noise reduction

Industrial

Quiet

zone

20 Oct-10

Thank you!