View
1.992
Download
5
Category
Preview:
Citation preview
Gas Chromatography - Olfactometry (GC-O or Sniffer)
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
The human nose is an incredible detector for aroma/mal-odor components. The sensitivity and selectivity are equal or better than the available GC detectors. Gas Chromatography - Olfactometry (GC/O) is the collection of techniques that combine Olfactometry or the use of human detectors to access odor activity in defined air streams with the Gas Chromatographic (GC) separation of volatiles.
PHASER – Gas Chromatography Olfactory Port
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
PHASER is an advanced sniffing port, through which an analyst using his/her sense of smell can efficiently sense and identify flavor and fragrance components separated by a gas chromatographic column. A column effluent is directly transferred to a PHASER nose cone through deactivated fused silica tube allowing the operator to smell the compounds that exit the column.
Why PHASER?
No-cold-spot design provides possibility to sniff high boiling compoundsTransfer line temperature up to 300 ˚COperator nose protection by adding moisturized air to sniffing portEasy-connect SilFlow™ micro-channel device as column flow splitterSitting or standing while sniffingCompact and easy-to-install on any type of GCVoice recording with replay function and voice recognitionWith or without MS detector
SilFlow is a trademark of SGE
PHASER – Gas Chromatography Olfactory Port
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Why PHASER?
No-cold-spot design provides possibility to sniff high boiling compounds
PHASER with 100 cm transfer line and Shimadzu 2010 GC
System setup
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Split Manager Software (standard supplied)
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Standard supplied with the PHASER comes the SplitManager software. This software helps to make a good and easy installation. All flows and split ration can be calculated.
Olfactory Voicegram Software (option)
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Olfactory Voicegram software features:
Recording analog detector data during runImport MS chromatogramsClickable aroma palette (configured by the user)Voice recognitionVoice recording and replay function on each peakOdour intensity can be set with the mouse buttonsFree software updates
Olfactory Voicegram Software for PHASER
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Aroma Palette for PHASER
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
With a touchscreen and the Aroma Palette (part of the software)
it is very easy for the operator to set the recognised smell.
The Aroma Palette must be configured to your own taste.
Different items for the PHASER
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
The installation can be done in different ways
65 or 100 cm transfer line
Y type nose cone
R type nose cone(standard)
www.glsciences.eu
GL Sciences B.V. | De Sleutel 9, 5652 AS Eindhoven, The Netherlands |Phone: +31 40 2549531 | info@glsciences.eu |www.glsciences.eu
Please visit www.glsciences.eu for more information