XSERIES 2 ICP-MS
Part of Thermo Fisher Scientific
e l e m e n t a l a n a l y s i s
XSERIES 2 ICP-MSTaking ICP-MS to higherlevels of performance andproductivity
XSERIES 2 ICP-MS
Thermo Scientific XSERIES 2ICP-MS (Inductively CoupledPlasma Mass Spectrometer) is a robust analytical instrumentcapable of meeting the mostchallenging requirements.It is a powerful and precisemeasurement tool designed tomaximize productivity in thelaboratory across a wide rangeof applications.
The XSERIES 2 ICP-MS offers analyticalscientists:• The world’s smallest benchtop ICP-MS• The highest throughput with protocol
compliance• An ICP-MS where the mass spectrometer
parts require no user maintenance • Unlimited flexibility through complete
Plug-and-Play upgradeability• Rapid start-up through Productivity packs
for routine analyses and comprehensiveoperator training courses
With the XSERIES 2, Thermo FisherScientific provides not just an analyticalinstrument, but a complete laboratorysolution that includes proven and reliablehardware, fully featured software, ongoingmethods development, and customerapplication support and training. All backedby a responsive worldwide serviceorganization and on-line knowledgeabletechnical support.
XSERIES 2 ICP-MS
More Practicality, M
ore Productivity, More Perform
ance
MorePracticality
XSERIES 2 ICP-MS
More Practicality, M
ore Productivity, More Perform
ance
Maximum Uptime … Minimum Maintenance
World’s smallest benchtop ICP-MSThermo Fisher ScientifIc has designed theworld’s smallest benchtop ICP-MS withtoday’s busy laboratories in mind. Withcovers constructed from inert compositematerials, the XSERIES 2 ICP-MS isequally at home in either high throughputenvironmental monitoring laboratories, busyclinical analysis laboratories or demandingsemiconductor clean room environments,where space is at a premium.
Proven simultaneous detectortechnologyAn advanced “plug in” simultaneousdetector system field proven for highsample throughput applications accuratelymeasures major and minor concentrationsin a single analytical run.
A unique cradle design ensures nocable connections inside the high vacuumarea for improved reliability and easycustomer replacement.
Careful attention to detail ensures thatboth heat dissipation and extractionrequirements are minimized, reducingenvironmental contamination and initialstart-up costs.
Future-proof technologyIntelligent modular design and a range ofunique plug-and-play performance optionsprovide flexibility and a guaranteed upgradepath to maintain future regulatorycompliance.
Maintenance-freemass spectrometerBased on innovative design models used inconsumer manufacturing processes, a radicalnew engineering approach has produced anICP-MS solution that’s as practical as it ispowerful. The maintenance-free InfinityII
Lens, quadrupole and detector systemsensure maximum productivity betweenscheduled preventive maintenance visits.
Highest signal-to-noise ratio ofany ICP-MS with collision cellcapabilityA compact, top-entry, cable-free vacuumhousing incorporating the robust InfinityII
Lens and an off-axis high-performancequadrupole mass analyzer combine todeliver the highest signal-to-noise ratio ofany ICP-MS, with the added bonus that theentire ion optics are identical in the wholerange of instrument models.
Advanced technology doesn’t have to be complicated. The XSERIES 2 ICP-MS makes eventhe most sophisticated of analytical protocols easy to implement.
MoreProductivity
Optimized Sample InterfaceThe Xt Interface minimizes polyatomicspecies in complex matrices enabling thedetection of iron at single-figure ppb levelsin standard ICP-MS operation. Uniqueproperties of the interface effectivelyextend the working range of the massspectrometer enabling the measurementof Na and other alkali metals to over200 mg/L in the same mass scan as ng/Llevels of trace analytes such as Pb and Cd.
By using the XSERIES 2 switchablequadrupole resolution, this dynamic rangecan be extended even further to over 400mg/L for sodium.
Optimized, accessible sample
Optimized, accessible sampleintroductionAn efficient, externally mounted sampleintroduction system is the foundation tomaximizing sample throughput. The openarchitecture ensures easy maintenanceand trouble-free connection to third partyaccessories.
Optimized plasma conditionsThree high-precision mass flow controllersand automated x, y, z torch positioningmaintain optimum plasma conditionsensuring consistent, reliable results withinan analytical protocol.
Productivity packsPredefined protocols facilitate worldwideregulatory compliance reducing start-uptime and increasing productivity. Methodtemplates, optimized acquisition parametersand customized reporting options areincluded to ensure the lowest cost persample analysis.
Unique productivity enhancement toolssuch as intelligent monitored uptake/rinseand protocol optimized autotune parameterssignificantly improve throughput andoperating efficiency.
Even the simplest configuration of theXSERIES 2 ICP-MS guarantees conformanceto latest worldwide environmentalregulatory protocols including US EPA 200.8,US EPA 6020A, US ILM05.3, Japanese JISK0102, German TVO, and UK DWI NS30.
The XSERIES 2 ICP-MS is also ideallysuited to the analysis of a wide variety ofsamples in other market areas, whichdemand high analytical performancecoupled with high sample throughput andmaximum uptime. The XSERIES 2 handlesclinical and pharmaceutical matrices withease, facilitating toxicology, nutritionaland biomedical studies. The high signal tonoise and efficient interference removalmake the XSERIES 2 the instrument ofchoice in fields such as geology andradionuclide measurement.
XSERIES 2 ICP-MS
More Practicality, M
ore Productivity, More Perform
ance
Operator-friendlyAll key system operations can be performedautomatically, from simple wizardinterfaces. Performance Reports and Auto-tune routines ensure that the system isalways set-up consistently and enablestotal unattended operation.
“Designed-in” application-specific protocolsTemplates can be tailored specifically toyour application needs to make it easy evenfor inexperienced operators to achievequick, accurate results.
Integral QA/QC packageAutomated real-time data validationroutines significantly reduce the number ofsample re-runs, improve productivity andlower overall cost per analysis.
Flexible reportingAnalytical reports can be adjusted to yourlaboratory requirements, using PlasmaLab’sflexible report generation and LIMSconnectivity.
Ease of Use and Performance Combined
PlasmaLab software for the XSERIES 2 gives the operator seamless control of all ICP-MS analysis routines, drawing on the ideas and best working practices of over 20 years of ICP-MS experience.
Simplicity through automation
Sample list showing QC flags
Simple spreadsheet style data entry
Flexible report generation anddata export
MorePerformance
PlasmaScreenTM Plus TechnologyGives sensitivity enhancement with boththe standard Xt and Xs interface optionswithout compromising the instrumentbackground. It is used with the Xt interfacefor improved hot plasma detectioncapability in both standard and CCTED
measurement modes or with the Xs forenhanced cool and hot plasma performancefor ultra trace analysis of high puritymatrices, giving sub-ppt detection ofLi, Na, K, Ca & Fe.
Micro LA-ICP-MS applicationsalso benefit from the improvedsignal-to-background withPlasmaScreen Plus Technology.
Xs InterfaceFor ultra-traceperformance in the analysisof semi-conductor reagents orother trace determinations such asthe analysis of radionuclides or REEsin geological materials, high sensitivityinterfaces can be fitted quickly and easily.
Peltier-Cooled Spray ChamberFor applications requiring reduced solventbased interferences or the ability to handleorganic matrices efficiently, the spraychamber can be cooled and preciselytemperature-controlled by a Peltier device.
CCTED
Third-generation collision cell technologyincorporating kinetic energy discriminationefficiently eliminates matrix and argon-based spectral interferences using simplereaction gases, minimizing unwanted sidereactions in the cell without complexelectronics.
Gas Control ModulesUp to two additional mass flow controllerscan be fitted to improve organic matrixhandling and/or enhance the use of high-performance, low-flow nebulizers.
* This product is protectedunder various patents, includingone or more of the following:US4760253 US6259091 GB2285170JP1778906 US5051584 EP0231131CA2045484 JP2516840 US5514868EP0407539 CA2143669 JP2922647US5767512 EP0871977 CA2241320AU0705918.
No Compromise Solution
A range of tailored options extends the XSERIES 2 performance and flexibility for the mostdemanding applications. These options provide a truly “no compromise” solution that isboth feature-rich and dependable for long-term reliability.
XSERIES 2 ICP-MS
More Practicality, M
ore Productivity, More Perform
ance
Sample Introduction SystemsConfigure the sample introduction system tosuit your application needs from the range ofnebulizers, spray chambers and ICP torches.Systems to cope with aggressive acids, highsolids and ultra pure chemicals are available.
Chromatography integrationand couplingHPLC and GC coupling kits allow full control of a Thermo Scientific or thirdparty chromatographic system for totallyintegrated speciation measurements.
Integrated Laser AblationSystemsDepending on your needs, a choice of fullyintegrated, easy-to-use laser ablationsystems allow you to analyze solids directly,without sample preparation.
Flexibility to exactly meet your requirements
Additional functionality and convenience features, as well as new and improved sampleintroduction systems, add value and even greater productivity to your XSERIES 2 ICP-MS.
XSERIES 2 with Trace GC Ultra™
Intelligent AutodilutionThe intelligent ID100 autodilutor worksseamlessly with the XSERIES 2 ICP-MS toimprove productivity and automate samplehandling to reduce sample re-runs to anabsolute minimum.
AutosamplersThe XSERIES 2 supports a complete range ofindustry standard autosamplers. IntelligentPICO technology automation routines deliverflexibility and drive productivity.
ID100 Autodilutor and Autosampler
XSERIES 2 with Accela™ XSERIES 2 with Laser
Customer TrainingTo ensure that maximum productivity isachieved as quickly as possible, ThermoFisher Scientific offers a range of operatortraining courses to cater for all levels ofanalyst experience:
Basic Operators Course Ensures that ALL users get the maximumperformance from the system by utilizingthe many features of the hardware andsoftware to make the analysis moreefficient.
Advanced Training CoursesTailored courses focus on specificapplication areas (Environmental, Clinical,Geological & Nuclear) and equip users withthe knowledge to develop new methods forthe analysis of these sample types.
Protocol Compliance AssistanceCoursesOn-Site assistance with the initialimplementation process to ensurelaboratories achieve validation forregulatory compliance.
With Thermo Fisher Scientificdemonstration facilities and ICP-MSspecialists located in all major countries youare never far from a quality assuredXSERIES 2 Training Course.
Customer SupportA total elemental analysis solution requiresmore than advanced technology and qualityproducts. It requires a high level of personalattention, applications support and on-siteservice.
This is one of the cornerstones ofThermo Fisher Scientific: a company-widecommitment to helping customers realizemaximum value for their investment in ourproducts through responsive, accessibleservice and support.
Highly skilled local Service Engineersare certified through rigorous factorytraining courses before any instruments aredelivered. A dedicated Support Team basedin the factory work to ensure that thehighest levels of support and products aremaintained and the web-based CustomerSupport forum gives 24 hour a day access tothe latest information, software updatesand consumables catalogs.
UpgradesThe specially designed XSERIES 2 ICP-MSupgrade packages offer total flexibility toupgrade your system. Every upgrade hasbeen custom designed and packaged tooffer the simplest and quickest route tocompletion together with on site installationwithout compromising the existingperformance of your XSERIES 2 ICP-MS.
Services to suit your needs - wherever you are
Support
XSERIES 2 ICP-MS
More Practicality, M
ore Productivity, More Perform
ance
The XSERIES 2 ICP-MS is designed to bea workhorse that even in its standardconfiguration can fulfill the needs of manyprotocols straight out of the box. For many
regulated applications, tailored productivitypacks provide all that is required to get upand running billable samples within days ofthe instrument delivery. In addition, the
various instrument and sample introductionoptions can be selected to optimize theXSERIES 2 for a diverse set of requirements.
Available application-specific configurations
Application sector Typical requirement Elements Recommended instrument options Recommended sample introduction options
Environmental Drinking water EPA 200.8, 98/83/EC No options required No options required
Sludge and soil digests EPA 6020A No options required Inert sample intro + Burgener Miramist nebulizer
Bore hole or hard groundwaters Group I & II, transition, toxic elements Peltier Burgener Miramist
Sea water or brine Transition metals, REEs, Th & U Peltier and CCTED Burgener Miramist + Ni Xs Interface
Nuclear pollution Tc, Am, Pu, Np, U Peltier Ni Xs Interface
Speciation LC-ICP-MS As, Cr, Sn etc Peltier, CCTED and Additional gas unit LC coupling kit
GC-ICP-MS Hg, Sn, S, Cl Additional gas unit GC coupling kit
Biomedical Blood Cd, Hg, Pb Peltier Burgener Miramist nebulizer
Urine As, Cr, Hg Peltier and CCTED Burgener Miramist nebulizer
Serum Al, Cu, Zn, Se Peltier and CCTED Burgener Miramist nebulizer
Biological tissue digests All metals Peltier and CCTED Burgener Miramist nebulizer
Pharmaceutical compounds QA All metals Peltier and CCTED No options required
Catalyst contamination Pt group metals Peltier and CCTED No options required
Semi-conductor Process chemicals SEMI specs. Peltier, CCTED and additional gas unit Pt Xs Interface, ESI PFA sample introduction
Si wafer wash SEMI specs. Peltier, CCTED and additional gas unit Pt Xs Interface, ESI PFA sample introduction
Organic solvents and photo-resists SEMI specs. Peltier, CCTED and additional gas unit Pt Xs Interface, ESI PFA sample introduction
Nuclear Fuel production QA/QC B, REEs Peltier Ni Xs Interface
Operator body fluid monitoring U, Pu Peltier Burgener Miramist nebulizer and Ni Xs Interface
Isotope ratio studies U Peltier Ni Xs Interface
Geochemical Groundwater and geochemical surveys Li to U Peltier No options required
Rock digests and lithium metaborate fusions Li to U Peltier Burgener Miramist nebulizer
Laser ablation ICP-MS REEs No options required Ni Xs Interface and Laser coupling kit
BR40336_E 02/07C
Thermo Electron (Bremen) GmbH is certified DIN EN ISO 2001:9000
©2007 Thermo Fisher Scientifc Inc. All rights reserved.All trademarks are the property of Thermo FisherScientific Inc. and its subsidiaries.
Specifications, terms and pricing are subject to change.Not all products are available in all countries. Pleaseconsult your local sales representative for details.
In addition to these offices, ThermoFisher Scientific maintains a network of representative organizationsthroughout the world.
Australia+61 2 8844 9500 • analyze.au@thermo.com
Austria+43 1 333 50340 • analyze.at@thermo.com
Belgium+32 2 482 30 30 • analyze.be@thermo.com
Canada+1 800 532 4752 • analyze.ca@thermo.com
China+86 10 5850 3588 • analyze.cn@thermo.com
Denmark+45 70 23 62 60 • analyze.dk@thermo.com
France+33 1 60 92 48 00 • analyze.fr@thermo.com
Germany+49 6103 408 1014 • analyze.de@thermo.com
India+91 22 6742 9434 • analyze.in@thermo.com
Italy+39 02 950 591 • analyze.it@thermo.com
Japan+81 45 453 9100 • analyze.jp@thermo.com
Latin America+1 608 276 5659 • analyze.la@thermo.com
Netherlands+31 76 587 98 88 • analyze.nl@thermo.com
South Africa+27 11 570 1840 • analyze.sa@thermo.com
Spain+34 91 657 4930 • analyze.es@thermo.com
Sweden / Norway / Finland+46 8 556 468 00 • analyze.se@thermo.com
Switzerland+41 61 48784 00 • analyze.ch@thermo.com
UK+44 1442 233555 • analyze.uk@thermo.com
USA+1 800 532 4752 • analyze.us@thermo.com
www.thermo.com
The use of an Inductively Coupled Plasmasource (ICP) is the accepted and mostpowerful technique for the analysis andquantification of trace elements in bothsolid and liquid samples. Its applicationsrange from routine environmental analysesto the materials industry, geologicalapplications to clinical research and fromthe food industry to the semiconductorindustry.
Thermo Fisher Scientific is the onlyinstrument manufacturer to offer the fullrange of Inductively Coupled PlasmaSpectrometers (ICP, Quadrupole and SectorICP-MS) to satisfy every aspect of plasmaspectrometry from routine to highlydemanding research applications.
Develop your lab from the easy-to-useiCAP ICP to the high performance XSERIES 2Quadrupole ICP-MS and up to the ultra-sophisticated ELEMENT2 and NEPTUNESector ICP-MS instruments. Each instrumentcombines leading-edge technology, fit forpurpose and affordability with a tradition ofquality, longevity, accuracy and ease of use.
Plasma Capabilities from Thermo Fisher Scientific
ELEMENT 2 Sector Field ICP-MS NEPTUNE Multicollector ICP-MS
XSERIES 2 ICP-MSiCAP ICP
Recommended