XL2

Audio and Acoustic Analyzer

Introducing the new flagship of the handheld EXEL line.

V1.001, Sep. 09

XL2

Audio and Acoustic Analyzer

• Sound Level MeterReal Time Analyzer

XL2

Audio and Acoustic Analyzer

• Sound Level MeterReal Time Analyzer

• Acoustic Analyzer

XL2

Audio and Acoustic Analyzer

• Sound Level MeterReal Time Analyzer

• Acoustic Analyzer• STI-PA Analyzer

XL2

Audio and Acoustic Analyzer

• Sound Level MeterReal Time Analyzer

• Acoustic Analyzer• STI-PA Analyzer• Audio Analyzer

XL2

Applications

• Live Sound Solutions • Sound Installations and

Recording Studios • Broadcast • Environmental Noise

Measurements • Service and Repair Centers

XL2

Configurations

• Set XL2 + M2210XL2 with M2210 - Extended Performance - Measurement Microphone withclass 1 frequency response

• Set XL2 + M4260XL2 with M4260 Measurement Microphone, Class 2

+

M2210

+

M4260

XL2 Interfaces

Big LCD 160x160with Backlight

Function Buttons

Limit LED withred, yellow, green Indication

Rotary Wheel

ShockProtectionJacket

HeadphoneOutput

Wire Stand

Rear Speaker

Battery Compartmentwith Li-Po Batteryincluded

Tripod Mount

Balanced &Unbalanced Input

Voice NoteMicrophone

Mains PowerAdapter Input

Digital I/O(prepared for later

firmware extension)

USB Interface

Mini-SD Card 2 GByteRemovable

TOSLink Output(prepared for laterfirmware extension)

XL2 Key Features

XL2

Features

• Flexible User Interface • Visual Limit LED of high sound

levels • Mini-SD Card, 2 GB removable • Real Time Clock • Built-in Speaker • Rechargeable Li-Po Battery

included • Automated Sensor Detection

reads electronic data sheet of M4260 and M2210

• Wave File Recording* • Voice Notes*

*optional

XL2

Sound Level Meter / RTA

• Applications– Live Sound Events– Environmental Noise Monitoring

XL2

Sound Level Meter / RTA

• Measures actual level, Leq, Lmin, Lmax, LCpeak, …

• Frequency weighting A, C, Z• Time Weighting F, S, I*• Linear operating range >100dB• XL2 accuracy acc. IEC 61672, class

1• Logs automatically to Mini-SD card• Real time clock

*optional

XL2

Sound Level Meter / RTA

Extended Acoustic Pack • Percentiles %: 1, 5, 10, 50, 90,

95, 99%• Time Weighting: Impulse• Sound Pressure Level LIeq

• Sound Exposure Level LAE• TaktMax as specified in DIN

45645-1• WAV-file recording (ADPCM) • Voice note recording• High-resolution FFT up to 0.3Hz

steps

XL2

Sound Level Meter / RTA

• All measurement results are simultaneously available.

• Select the available levels to be shown on the XL2 display

XL2

Sound Level Meter / RTA

• 3 or 5 levels may be displayed simultaneously in different selectable sizes

XL2

Sound Level Meter / RTA

• Displays two spectra simultaneously

• Resolution selectable• Broadband values displayed in

parallel• Measurement range selectable• Measurement time and control

XL2

Sound Level Meter / RTA

• Pre-defined limits for all levels• Firmware V1.00 operates with

fixed limits– Level ok Limit LED is

GREEN – Level near limit LED is

YELLOW– Limit exceeded LED is RED

XL2

Live Sound Challenges

• Sound pollution protection limits maximum level in audience area.

• Loudest audience position is commonly not accessible for measurements.

• XL2 offers a wizard to measure correction values k1 and k2 between loudest position and measurement point

Public listening area

Stage

FOH

Loudest accesible position Audience position

MeasurementPosition

k1 = Difference in LAeq

k2 = Difference in LCPeak

XL2

Correction Factor Wizard

• Run Pink Noise in the auditorium

• Measure level at the loudest position

• Measure level at the measurement point, e.g. at the mixing desk FOH

• XL2 stores results with time stamp and displays the calculated correction values k1 and k2

XL2

Audio Analyzer

• Balanced XLR, unbalanced RCA input

• -112 dBu to 30 dBu (1.4uV to 25V)

• Residual THD+N <-100dB (0.001%)

• Frequency range: 9 Hz to 20 kHz

• Frequency accuracy: 0.003%• Loudspeaker and headset

output for signal monitoring

XL2

FFT Analyzer

• Measures LZF and Leq simultaneously

• Real time FFT in 3 ranges– 10 Hz - 220 Hz with 1.5 Hz steps– 20 Hz - 1.7 kHz with 15 Hz steps– 200 Hz - 20 kHz with 150 Hz

steps

• High-resolution FFT including zoom mode up to 0.3 Hz steps with Extended Acoustic Pack

XL2

RT60 Analyzer

• Measures 8 octave bands from 63 Hz – 8 kHz according to ISO3382 by Schroeder-method

• Auto triggering• Auto averaging• Measurement error indication• Stimulus:

– Gated pink noise– Impulse sound source

XL2

Polarity Testing

• Checks polarity of speaker cabinets, individual drivers and line signals

• Positive/Negative detection • Using internal microphone or

input signal of XLR/RCA connector

XL2

Polarity Testing

• In-depth verification of the polarity - frequency relation for speaker cabinets or other multi-way-systems

• Sample Screenshot left:The major part of the signal energy is measured in the mid-range frequency bands, thus the overall displayed polarity is NEGATIVE.

XL2

Propagation Delay

• For accurate setup of delay line arrangements

• Measures delay between electrical reference and acoustical signal

• Relative measurements supported

• Displays distance to speaker in meter or feet

XL2

STI-PA Analyzer

• Measures speech intelligibility of public announcement systems

• Complies with IEC 60268-16 (2003) and NFPA 72

• Displays STI and CIS results• Shows table of modulation

indices and Leq’s• Supports ambient noise post

processing

*optional

XL2

Application Profiles

• XL2 supports application profiles

• Application profile may disable and hide any selections or measurement functions

• Allows fixed operator interfaces for basic users

• Firmware V1.0 offers a set of fixed application profiles

XL2

Store and Log Results

• Results stored as ASCII files• Storing all or subsets of

measurements results• Adding a voice note to

measurement* • Records the ADPCM compressed

audio signal in parallel*

*optional

XL2Automated Sensor

Detection

• Automatically detects microphone type– Reads sensitivity– Reads product data– Shows last calibration

• ASD CableExtension cable tandem up to 20 m supported

XL2

Powering Concept

• Rechargeable Li-Po battery– included– typical battery lifetime > 5 hours

• Dry cell batteries– type AA, 4 x 1.5 V– typical battery lifetime > 4 hours

• Mains power supply 9 VDC– charges Li-Po battery in operation

Measurement Microphones

XL2

Measurement Microphones

• Omni-directional, pre-polarized condenser, free-field microphone

• Build-in Pre-amplifier• Electronic Data Sheet installed • Phantom Power 48 VDC• High dynamic range • Wide frequency range• Low residual noise

M2210 M4260

XL2

Comparison of Microphones

M4260M2210 –Extended Performance

Capsule / Transducer  1/4”

permanently installed capsule

1/2” detachable capsulewith 60UNS2 thread

Flatness  

Class 2 (IEC61672-1)< ±1 dB @ 100 Hz - 1250

Hz< ±3 dB @ 20 Hz - 20 kHz

Class 1 (IEC61672-1)< ±1 dB @ 100 Hz - 4

kHz< ±2 dB @ 10 Hz - 20

kHz

Frequency Range   20 Hz - 20 kHz 1 Hz - 20 kHz

Residual Noise Floor typical   24 dB(A) 18 dB(A)

Upper Limit of Dynamic Range typ.

  136 dBSPL 145 dBSPL

Sensitivity typical  -30 dBV/Pa ±4 dB

(30 mV/Pa @ 1kHz)-34 dBV/Pa ±3 dB

(20 mV/Pa @ 1kHz)

XL2 Accessories

XL2

Accessories

• Ever-Ready pouch– Detachable front flap – Connectors accessible– Zipper

• EXEL System Case– Compartments for XL2, MR-PRO,

M4260 or M2210– Accessories, battery and

adapter

XL2

Accessories

• Battery Charger– Includes spare battery– Connects to 100-230V AC – Intelligent charger controller

• Spare Battery– rechargeable spare battery– Li-Po battery

XL2

Accessories

• ASD Cable– For extended connections of the

measurement microphones M4260 or M2210

– Maintaining the automated sensor detection

– Length = 5 meter (16 feet)

• External AC power supply– Suitable also for use with MR-

PRO– Operates XL2 and chargers Li-Po

battery in parallel

XL2

Firmware Options

• Extended Acoustic Pack– Percentiles: 1%, 5%, 10%, 50%,

90%, 95%, 99%– Time Weighting: Impulse – Sound Pressure Level LIeq, Sound

Exposure Level LAE – TaktMax and values as specified in

DIN 45645-1 – WAV-file recording (ADPCM) – Voice note recording for individual

measurements – High-resolution FFT including zoom

mode up to 0.3 Hz steps at 10 Hz - 20 kHz

XL2

Firmware Options

• STI-PA Option– Measures speech intelligibility of

public announcement systems– Complies with IEC 60268-16

(2003) and NFPA 72– Displays STI and CIS results

New Technologies in Audio