Tracker Thermal Control System
2023年4月21日 1
AMS-TTCS Status Report
AMS-TIM meeting, CERN, Oct.28th, 2008
ZH He
On behalf of SYSU team:
Y Chen, ZC Huang, TX Li, SS Lu, DC Mo, XM Qi, XH Sun, GL Tong, ZX. Wang, ZL Weng, RA You, YC Zhang, Z Zhang.
Tracker Thermal Control System
2023年4月21日 2
OutlineOutline
• Working meeting in Zhuhai
• QM condenser test
• TTCS Functional Test for secondary loop in 3d layout
• Exceptional hot case test result
• Evaluation of air cooling solution
• Documents finished
Tracker Thermal Control SystemTTCS Zhuhai Working MeetingSeptember 29th to October 3rd
2023年4月21日 3
Tracker Thermal Control System
Condenser QM Test StatusCondenser QM Test Status
2023年4月21日 4arrival
2008/09/28 2008/09/29
Tracker Thermal Control System
2023年4月21日 5Working hard to fix
Tracker Thermal Control System
2023年4月21日 6He leak test: passed
Tracker Thermal Control System
2023年4月21日 7
Heater mounting
Tracker Thermal Control System
2023年4月21日 8
Heaters mounted
Tracker Thermal Control System
2023年4月21日 9
Thermal couple mounting
Tracker Thermal Control System
2023年4月21日 10
Heater plate mounted
Tracker Thermal Control System
2023年4月21日 11
Thermally insulated
Tracker Thermal Control System
2023年4月21日 12
Put into the chamber
Tracker Thermal Control System
2023年4月21日 13Connected to the test loop
Tracker Thermal Control System
TTCS FUNCTIONAL TEST FOR TTCS FUNCTIONAL TEST FOR SECONDARY LOOP IN 3D LAYOUTSECONDARY LOOP IN 3D LAYOUT
2023年4月21日 14
Tracker Thermal Control System
Walk- in Climate Chamber
Shorten the evaporator outlet
tubes to save room
Wake Radiator located drawn for clarity ( not build)
Wake Condenser located in bench top climate
chamber( located at the far back)
RAM and WAKE ( the tube length is kept constant )
RAM Condenser located in bench top climate
chamber ( located at the far back)
D
Top
B
Climate chamber
door
2023年4月21日 15
Layout of TTCS Layout of TTCS 22ndnd Loop Loop
Tracker Thermal Control System
2023年4月21日 16
TTCS Functional Test TTCS Functional Test for 1for 1stst loop in 3d Layout loop in 3d Layout
Tracker Thermal Control System
2023年4月21日 17
TTCS TTCS Functional Functional Test for 2Test for 2ndnd loop in 3d loop in 3d
LayoutLayout
Tracker Thermal Control System
2023年4月21日 18
• Objective:– To test the performance of TTCS in the orientation
as that in the TVT test and the Beam test.– To check any difference of performance between
the 1st and 2nd loop in gravity.
• Test items:– Test cases: extremely hot (23C), coldest (-15C)
– Operation and control test: Start-up, shut-down, heat load change, heat load imbalance, pump speed change, rapid change of condenser temperature.
Some representative results are shown below
Tracker Thermal Control System
2023年4月21日 19
Start-up Start-up
Set point
In coldest case with start-up heaterIn extremely hot case without start-up heater
Tracker Thermal Control System
2023年4月21日 20
Heat load imbalance test in extremely hot caseHeat load imbalance test in extremely hot case
Tracker Thermal Control System
2023年4月21日 21
Heat Load Change TestHeat Load Change Test
In coldest casein extremely hot case
Tracker Thermal Control System
2023年4月21日 22
Rapid Change of Condenser TemperatureRapid Change of Condenser Temperature
Pump_inlet
Set point
Tracker Thermal Control System
2023年4月21日 23
Pump speed changePump speed change
3g/s
2g/s
4g/s
In coldest casein extremely hot case
Tracker Thermal Control System
2023年4月21日 24
Walk-in Climate Chamber
Front View to (Walk-in) Climate Chamber Looking from D-side
Top
A
C
Bench Top Climate Chamber
Condensers
Connecting tubing located in a plastic pipe connected to the controlled air of
the climate chambers. Additional outside insulation to avoid condensation on the
plastic tube
Vapor flowing down Vapor flowing down for 2for 2ndnd loop loop
Open to discussOpen to discuss
Tracker Thermal Control System
2023年4月21日 25
Pump speed (RPM)
DPS (mbar) for stable loopPrimary loop (3D) Secondary loop(3D)
4000 137mbar (dry-out )
5000 200mbar (220mbar for g)
210mbar (dry-out ) (200mbar for g)
7500 420mbar 440mbar
10000 730mbar 740mbar
Pressure Drop Comparison in Hottest CasePressure Drop Comparison in Hottest CaseOpen to discussOpen to discuss
Tracker Thermal Control System
2023年4月21日 26
Summary Summary
• TTCS functional test is done for the 2nd loop in 3d layout.• The loop in 2nd 3d layout operated very well and passed
the test; it has some what lower performance than that in 1st loop 3d layout.
• Suggestion for control scenario (done by ground control):– Do not run the loop at pump speed lower than 7500RPM in any
tracker operation case for ground test.– Use the start-up heater to depress pressure spike caused by
superheating during the start-up process in nominal case and cold case.
Tracker Thermal Control System
Exceptional hot case TestExceptional hot case Test
• Purpose– To evaluate the cooling capacity and stability of
TTCS in the exceptional hot case, Tsp>23C– To provide reference of cooling scheme for beam
test and ground functional check.
• Tsp=26C Tevp 27C Ttracker 37C• For secondary Loop (worst case)
2023年4月21日 27
Tracker Thermal Control System
Setpoint Change in Exceptional hot case TestSetpoint Change in Exceptional hot case Test
Tsp: 23C to 26C
2023年4月21日 28
Tracker Thermal Control System
Tsp=26 C; T=2.5C;
Heat Load Change in Exceptional Hot Case Test Heat Load Change in Exceptional Hot Case Test
2023年4月21日 29
Tracker Thermal Control System
2023年4月21日 30
Summary Summary
• TTCS 2nd loop in 3d layout can operate at the set point temperature of 26C, with subcooling of 2.5C and heat load of 200W.
• In the exceptional case, the vapor quality is above design value (0.4).
Tracker Thermal Control System
Air Cooling Scheme EvaluationAir Cooling Scheme Evaluation
• From simulation, temperature difference between the radiator surface and the return CO2 liquid in condenser outlet is about 7C for heat load of 144W;
• For subcooling of 2C, the radiator surface temperature must be 9C below the set point temperature;
• For the highest set point temperature of 26C, the radiator surface temperature must be below 17C.
2023年4月21日 31
Tracker Thermal Control System
Solution Solution (presented by Johannes)(presented by Johannes)
• Employing force air panels on the top of the radiators to produce turbulent flowing effect, and forming a close air loop;
• Blowing chill air on the top the radiators with tracker working at half of its maximum power (72W).
2023年4月21日 32
Tracker Thermal Control System
Documents Finished since last TIMDocuments Finished since last TIMTitle DOC.# Date Prepared by
TTCS EXTREME-TEST PROCEDURE FOR 3D SECONDARY LOOP
TTCS-SYSU-TEST-TPR-014-1.0
2008-8-7 X.H.Sun
CHANGE SETPOINT TESTTTCS-SYSU-TEST-
TRP-008-1.02008-8-2
Guinian Tong
TTCS EXTREME TEST REPORT FOR 3D SECONDARY LOOP
TTCS-SYSU-TEST-TRP-009-1.0
2008-8-7 X.H.Sun
TTCS EM TEST REPORT FOR both 1ST AND 2ND LOOP IN 3D LAYOUT
TTCS-SYSU-TEST-TRP-010-1.0
2008-8-25X.H.Sun, Y.Chen
Investigation AMS TTCS air coolingTTCS-SYSU-SIMU-RP-
007-1.02008-10-22 Shushen Lv
Heat Pipe Failure Sensitivity AnalysisTTCS-SYSU-SIMU-TN-
005-2.02008-07-22 D.C.Mo
simulation on TVT testTTCS-SYSU-SIMU-TN-
006-1.02008-10-15 D.C.Mo
TTCS QM CONDENSER PERFORMANCE AND THERMAL
CYCLING TEST PROCEDURES
TTCS-SYSU-TEST-TPR-013-3.0
2008-10-9Z.ZhangZL.Weng