The PrimEx HyCal Calorimeter. Outline HyCal calorimeter PbW0 4 detectors Resolutions Transition region. A. Gasparian NC A&T State University, Greensboro, NC. 1. The PrimEx HyCal Calorimeter. 1152 PbWO4 individual crystal detectors (70 x 70 cm 2 insertion). - PowerPoint PPT Presentation

Citation preview

5/10/2010 1GlueX Col meeting, A. Gasparian

1

The PrimEx HyCal Calorimeter

A. GasparianNC A&T State University, Greensboro, NC

Outline

HyCal calorimeter PbW04 detectors Resolutions Transition region

5/10/2010 2

The PrimEx HyCal Calorimeter

1152 PbWO4 individual crystal detectors (70 x 70 cm2 insertion)

GlueX Col meeting, A. Gasparian

576 Lead Glass detectors

5/10/2010 3

The HYCAL Calorimeter (Crystal part)

GlueX Col meeting, A. Gasparian

Calor-2004, March 30 A. Gasparian 4

PbWO4 Crystal Dimensions

Geometrical size:

20.5 x 20.5 x 180.0 mm3

Tolerances (mm):

20.5 + 0.0 - 0.1 180.0 + 0.3 -0.0 Specified

Measured

Calor-2004, March 30 A. Gasparian 5

PbWO4: Optical Properties

04/21/23 6

PbWO4: Position Resolution vs. Energy

Detector characteristics and resolution have been done in different ways: with secondary electron beam (PS in Hall B); with low intensity tagged photon beam (Hall B tagger)

σ =2.7 mm @ 1. GeV

04/21/23 7

PbWO4: Position Resolution vs. impact coordinate

04/21/23 8

Lead-Glass: Position Resolutionvs. Energy

σ =5.6 mm @ 1. GeV

04/21/23 9

PbWO4: Energy Resolution vs. Energy

σ =2.45% @ 1. GeV

04/21/23 10

Lead-Glass: Energy Resolution vs. Energy

σ =5.7% @ 1. GeV

04/21/23 11

Transition Region: PbWO4 - Lead-Glass

04/21/23 12

Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate

04/21/23 13

Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate (Eγ = 5.2 GeV)

04/21/23 14

Transition Region: PbWO4 - Lead-GlassPosition Resolution (Eγ = 5.2 GeV)

04/21/23 15

Transition Region: PbWO4 - Lead-GlassReconstructed Energy (Eγ = 5.2 GeV)

04/21/23 16

Transition Region: PbWO4 - Lead-GlassEnergy Resolution (Eγ = 5.2 GeV)

5/10/2010 17

Sensitivity to Magnetic Field

GlueX Col meeting, A. Gasparian

Possible modifications:

change the G10 housing to sift ion housing and extend it to ~1”

insert optical extension

extend the brass strips (look at different options first)No need to change the optical wrapping

The current design do not have extended µ-metal on photocathode Try to shield the FCAL frame with some µ-metal, if it is all possible

5/10/2010 18

Summary

The Hybrid Calorimeter concept have been successfully reapproved with the HyCal calorimeter in the PrimEx experiment.

Technical and methodical aspects of the Hybrid calorimeter are well understood and tested. On-site expertise is available.

HyCal is equipped with ~2000 channel power supply (CAEN) unit; Trigger and analog electronics are old.

1152 PbWO4 high resolution, radiation hard crystal detectors are available for future experiments.

HyCal will stay in Hall B up to the end of PrimEx-II experiment.

GlueX Col meeting, A. Gasparian

5/10/2010 19A. Gasparian GlueX Col meeting, A. Gasparian

19

The End

04/21/23 20

Invariant Mass Resolution

PbWO4

onlyPb-Glassonly

Recommended