Imagination at work
The new OPC UA Discovery Specification delivers new value to Automation Solutions
GE Intelligent Platforms
September 2015
AGENDA
• OPC UA: Enabling Industrial
Internet
• OPC & OPC UA – Key components
• GDS (Global Discovery Server)
• Conclusion
2
The Industrial Internet
• Entertainment is digitized
• Social marketing emerged
• Communications mobilized
• IT architecture virtualized
• Retail and ad transformed
• Monitoring to component levels
• Predictive maintenance
• Energy and fuel efficiencies
• Virtualized operations technology
• Workforce transformation
Consumer Internet Industrial Internet
What happened when 1Bpeople became connected?
What happens when 50Bmachines become connected?
Industrial Internet - Connecting Assets & People
5
BRILLIANT
MACHINES
Connect machines,
facilities, fleets and
networks with advanced
sensors, controls and
software applications
ADVANCED
ANALYTICS
Optimize Operations
Combine the power of
physics-based analytics,
predictive algorithms, and
domain expertise
PEOPLE
AT WORK
Connect people at
work any place, any
time for intelligent
operations
DATA INFORMATION
EGDProprietaryModbusProfinetECAT
Industry Standard ProtocolsSystems that speak the same language
OPC UA
The interoperability standard
Data ModelsTurn data into knowledge
Knowledge
Information
Data
Authenticate Encrypt
SecurityTrusted communications
OPC UAEvolving Standards for Greater Interoperability
• OS independent communication standard
• Client Server Architecture
• All encompassing - Data, Alarm and Conditions, historical
data
• Robust Data Modeling
• Secure IT friendly communications
8
Driving the Right Outcomes in Your Business
• Reduced communications configuration time & costs
• Drive secure-by-design connectivity
• Improve reliability and redundancy for higher uptime
• Connect to your multiple platforms for greater flexibility
• Leverage data from legacy systems for improved intelligence
9
Why OPC UA for GE?
A strategic decision within GE - Seamless integration of our
own components across GE & of 3rd party’s
• RXi PLC
• Proficy HMI/SCADA
• MarkVIe
• ADAPT 3701
• System 1
• 8 Series
• 3 Series
The 13 parts of OPC UA
[UA1] Overview and Concepts
[UA2] Security Model
[UA3] Address Space Model
[UA4] Abstract Services Def.
[UA5] Information Model
[UA6] Mapping of the abstract
services to a concrete technology
[UA7] Profiles for OPC UA clients
and servers
[UA8] Data Access
[UA9] Alarms and Conditions
[UA10] Programs
[UA11] Historical Access
Core Specification Access Types
(specializations for data access)
[UA12] Discovery
[UA13] Aggregates
Utility Specification
• Device configuration is time
consuming
• Legacy installs make it even more
complicated
• To keep this information up to date is
very difficult over time
• Certificate Management is an
unknown concept for many
Why a GDS?*Global Discovery Server
GE Global Discovery Server (GDS)Based on part 12 of the Specification
1. Server discovery
• Local discovery and global discovery
• Compliant servers broadcast their endpoints
• Provide list of available endpoints to clients for ease of configuration
2. Certificate management
• Acts as a certificate authorityand store for UA client andserver connections
• Facilitates the exchange ofcertificates to enable easierconfiguration
Before and After OPC UA and GE GDS
BEFORE AFTER
Manual entry of end point addressesAutomatically locate devices quickly and
easily throughout the site
Certificate Management was painful
– time consuming
Facilitates the exchange of certificates on
behalf of the user
Manual synchronization of certificatesTake advantage of existing authentication
services
Some devices cannot talk (“headless”)!Implements push/pull for client/servers
– Device initialization
Reduces implementation costs & overall lifecycle costs
Even if your devices don’t talk OPC UA …they can still communicate
• Leverage a GE gateway
(Agent) to secure your
system even without GDS
aware devices
• Agent populates the device
directory on behalf of the
Server
• Manages certificate
exchange for UA servers
Continuing theJourney toSelf-ConfigurationManaging Systemswithout IT Support
• Plug and play user experience to
provide faster time to solution and
value – reducing costs
• Model for configuring smart devices
• Integrated user experience for control
and HMI/SCADA
• Integrated user experience for
heterogeneous hardware
17
From Assets to the Plant to Global SitesAggregating Data Vertically and Horizontally – with Scalability
*APM: Asset Performance Management
A cornerstone of the
Industrial Internet & a
foundation for the APM*
OPC UA GDS* by GEConfiguring a SCADA to talk to a GDS-enabledOPC UA Server in 3 simple steps
1. Register with the GDS
2. Create/Sign Certificate by the GDS
3. Update Trust List
Released in Jan. 2015 for the
Industrial Internet Control Systems
The first of its kind on the market
* GDS: Global Discovery Server
GDS-enabled
OPC UA Server
HMI/SCADA OPC
UA Client
3rd Party UA Client
(UA Expert)
One-button
Configuration
Reducing Costs and Saving Timewith Greater Interoperability
• Modularity enables architectural flexibility and cloud
assisted design
• Consistent interoperability enables a better experience
• Data server provides scalability and flexibly to leverage new
devices and bring forward existing investments
• New tools built on this foundation
will provide new value for
automation solutions
20