View
236
Download
0
Category
Preview:
DESCRIPTION
Citation preview
Architecture Students Award Project: Green & Sustainable School Institute: Madhav Institute of Technology & Science
India
Project Highlights
• “Green & Sustainable Primary School” Design • Rain Water Harvested – 22% • Water Recycled – 72% • Rooms Well Ventilated – 92% • 100% Powered By Mix Of Wind Energy And Solar Energy • Green Area Of Total Land Area – 37% • Bio-toilets For Biogas Generation • Waste Water Treatment System (Reed Bed Technology)
Winner: v Madhur Goyal
Engineering Students Award Project: Energy Efficient Engineering University Institute: University of Philippines, Philippines
• Appropriate Usage Of Technologies o Ice Thermal o District Cooling o Rain Water Collection o Solar Day Light
• Good Document Support • Can Be Realistically Applied
Project Highlights
Winners: v Allan C. Liguan v Erwin Phillippe T. Beronio v Binoe E. Abuan v Ruben A. Bongat
Project: Global Education Centre Location: Infosys Mysore, India Application: Training Centre/Office Total Size: Water Cooled Chillers (250TR X 4)
Retrofit Building Excellence Award
Project Highlights • Built-up Area 440,000 sq. ft., 52 Training Rooms, 183 Faculty Rooms, Library With 60,000 Books • Project Involves Redesigning and Right Sizing Of Chilled Water Setup • The Results Were –
• Reduction In Energy Consumption – 30% • Reduction In Pumps Connected Load – 70% • Reduction In Plant Room Space – 23%
• ROI Of Less Than 2 Years
Winner: v Infosys Mysore,
Green Initiatives Team
Project: Project Optimizer, Hotel Vasant Continental Location: New Delhi, India Application: Hotel Total Size: Water Cooled Screw Chillers (285 TR X 3)
Retrofit Building Excellence Award
• Optimization Of Energy Usage Through Integration Of Appropriate Technologies • Implementation Of Various Energy Saving Measures In A 30 Year Old Hotel Building • Best Energy Efficiency Without Compromising Guest Comfort. • Optimized Air-conditioning Systems Within The Prevailing Constraints • Attractive ROI Ranging Through 1-3 Years
Project Highlights Winner: v Ujjal Majumdar,
Chief Engineer
Project: Office Building For Lakshmikumaran & Sridharan
Location: New Delhi, India Application: Office & Guest House Total Size: Air Cooled Digital Scroll VRF, 240 HP
New Building With Emerson Technologies Honorary Award
• Holistic Approach To Building Design By Combining Architecture With Practicality Of Energy Savings • Appropriate Selection Of High Efficiency Digital Scroll Technology • Caters Individualistic Heating / Air-conditioning Needs And Usage, With Minimal Life Cycle Cost • MoreThan 75% Of Space Lit With Daylight • Solar Panels (25KW) For Partial Feed To Building.
Project Highlights
Winner: v Pankaj Khullar,
ENAR Consultants
Project: Holy Stadium Location: Indonesia Application: Stadium Total Size: 1152HP Package System With Copeland Scroll Compressors
New Building With Emerson Technologies Excellence Award
• 25-30% Heat Gain Reduction By Using Passive Design Concept “Shell And Core Building” • Jet Nozzle Installed To Cool The Occupant Area • Air Ducting Eliminated By 80% • Reduced Total Cooling Load By 20% • Applied Active Heat-pipe Air Conditioning With Copeland Compressor
Project Highlights
Winner: v John Budi H Listijono,
PT Metropolitan Bayu Industri
Project: Prana Location: Bangalore, India Application: Home Office Total Size: Scroll Chiller + Radiant Cooling
Project Highlights
New Building Special Mention
• Green Initiative By ISHRAE To Show-case Latest Green Technologies • BMS Monitored Fully Functional High Performance Home Office Spread Over 200 Sq.M • Radiant Cooling For Floor And Ceiling, Earth Air Tunnel System For Fresh Air • Rain Water Harvesting, Low Water Flow Toilet Fittings • Part Power GenertionThrough Solar PV Cells Of 3 KW
Winner: v Sharukh Mistry,
Mistry Architects
Project: Bayer, Eco Commercial Building
Location: Greater Noida, India Application: Office Total Size: 30 TR Water Cooled Scroll Chiller + Chilled Beams
New Building Honorary Award
• First NET Positive Energy Building Of India • LEED Platinum Certified Project • Savings : 40% Compared With The ASHRAE 90.1-2004 Baseline • Carbon Reduction Strategies: 100% Solar, Emission-free On-site Energy Generation + Chilled Beam For Radiative Cooling Based Air Conditioning • Water Conservation: Zero Water Discharge
Project Highlights Winners:
v Ashish Rakheja, AECOM India
v Amogh Sule, Sankalpan Architects
Project: Software Development Block-1 Location: Infosys Hyderabad, India Application: Office Total Size: 325 TR Centrifugal + 275 TR Screw Chillers (Water Cooled)
New Building Honorary Award
Project Highlights • Integrated Design Approach, Achieving A Cooling Ratio Of 600 Sq.Ft .Per TR • 40% More Efficient Than ASHRAE Baseline Building • Natural Light (270 Lux) For More Than 90% Of Office • Radiant Cooling Technology, EPI - 82 Kwh/Sqm • 79% Construction Waste Diverted From Landfills. • Recycled Content 18% Of Total Materials Cost
Winner: v Infosys Mysore,
Green Initiatives Team
Project: Energy Commission Diamond Building
Location: Putrajaya, Malaysia Application: Office Total Size: 1462 HP Chiller
New Building Excellence Award
• Chilled Water Supply from Gas District Cooling • Low OTTV At 35 W/m2K • Apply Radiant Cooling With Thermal Mass Storage • Rain Water Harvesting • Used Recyclable Material • Renewable Energy From Photovoltaic • Achieve With Less Than 10% Development Cost
Project Highlights Winner: v Ahmad Izdihar Bin Supaat,
Primetech Engineers Sdn Bhd