ML2164 SeriesFLUSH MOUNT METAL PLATE MEDICAL SERVICE PANELS
cl ipsal .com/cis
Introduction 2
ML2164 Series
THE MODULAR ALTERNATIVE 4
AS3003 Electrical Instal lations
PATIENT TREATMENT AREAS 5
Customise to suit your requirements 6
Wall Boxes 7
Grids 8-9
Facias 10
Accessories 11
Contents
Introduction
Hospitals have undergone a dramatic transforma-
tion in the past 20 years. The development of less
intrusive medical techniques has meant that patient
recovery times have been greatly reduced. As a
result, day surgery clinics are now a feature of
almost all hospitals.
The hospital environment too, is now a less
intrusive one. No longer clinical and old, patient
accommodation today is often of hotel standard.
Although there is a greater reliance on hi-tech sup-
port equipment, this is now designed to blend into
the surroundings, creating a more relaxed environ-
ment for both patients and medical staff.
The Medilec Range of hospital equipment has been
designed to meet this growing demand for
hospital services and equipment that are attractive
and less intimidating.
ML2164 SERIES
THE
MO
DU
LAR
ALT
ER
NA
TIV
EM
L216
4 Se
ries
4
Now an impressive part of the Medilec Range, the
ML2164 Series is a range of Flush Mount Metal Plate
Medical Service Panels. The ML2164 Series is designed
to incorporate the Medilec ML2000 and Clipsal 2000
range of electrical accessories, as well as the various
OEM products based on the Clipsal 2000 format, which
include nurse call systems and gas outlets, etc.
The ML2164 Series produces a very attractive modular
Medical Service Panel System that can be assembled
quickly and easily.
Features
The ability to integrate the extensive range of Medilec
ML2000 and Clipsal 2000 series accessories, and
OEM 2000 series nurse call systems and gas outlets.
Grid mounted accessories allow for individual access
to each service without interruption to other serv-
ices.
A choice of facia fi nishes and colours including natu-
ral high grade stainless steel and powder- coated
fi nishes.
Adjustable grid height to allow easy positioning of
accessories fl ush with the wall surface.
Modular 1 to 4 gang components can be quickly
assembled together to produce special length panels
to suit the customer’s requirements, creating a sig-
nifi cant reduction in delivery times.
MEETING THE HIGH STANDARDS
All the ML2164 Series electrical accessories comply with
the relevant Australian Standards for electrical safety (as
well as standards for patient treatment areas) including
AS3003 - “Electrical installations: patient treatment areas
of hospitals and medical and dental practices”.
Pa
tien
t trea
tme
nt a
rea
s E
LE
CT
RIC
AL
INS
TA
LL
AT
ION
S
5
AS3003 : ELECTRICAL INSTALLATIONS - PATIENT
TREATMENT AREAS OF HOSPITALS AND MEDICAL
AND DENTAL PRACTICES
The ML2164 Series product range is designed to meet
the requirements of AS3003. AS3003 sets out the spe-
cialist electrical installation requirements often found in
the following premises:
Hospitals
Medical Practices
Dental Practices
Physiotherapy Practices
The areas within these premises that would need to
meet AS3003 are classfi ed as Body or Cardiac Protected
Areas. The procedures carried out to classify these areas
as Body or Cardiac Protected are as follows:
Within Body Protected Areas procedures are carried out
where a patient is connected to an item of electromedical
equipment which reduces the impedance of the skin by
either electrode paste or by the enterance of conducting
fl uids, metal needles, saline fi lled catheters, etc.
Within Cardiac Protected Areas the same procedures
are carried out as in the Body Protected Areas but also
procedures where a patient has an electrical conductor
placed within the heart or is likely to come in contact
with the heart eg. electrical wires such as cardiac pacing
electrodes and intracardiac ECG electrodes, or insulated
tubes fi lled with conducting fl uids.
CU
STO
MIS
E T
O S
UIT
YO
UR
RE
QU
IRE
ME
NTS
ML2
164
Seri
es
6
ML2164 System
CUSTOMISE TO SUIT YOUR REQUIREMENTS
A unique feature of the ML2164 Series is that it can be
quickly and easily customised to suit the customer’s
specifi cations. The system has been designed in such
a way that the standard components can be joined
together to produce a custom Medical Service Panel. The
advantage of this is the signifi cant reduction in delivery
times, which means the wall box assembly, grids, and
accessories can be supplied and installed almost imme-
diately. The only item required to fi nish the installation
would be the custom manufactured facia which would
be supplied shortly after.
ML2
164 SeriesW
ALL B
OX
ES
7
WALL BOXES
Features
Adjustable grid height allows easy positioning of
accessories fl ush with the wall surface. The front face
of the wall box can be mounted between 0 to 30mm
behind wall surface.
Multiple entry points.
Provision for mounting segregation between gangs.
If a longer panel is required the standard wall boxes
are designed so they can be easily joined together
using the ML2164JT Joining Tray.
CATALOGUE NUMBER DESCRIPTION
ML2164/1W 1 gang wall box. 120mm(H) x 104mm(W) x 65mm(D).
ML2164/2W 2 gang wall box. 120mm(H) x 176mm(W) x 65mm(D).
ML2164/3W 3 gang wall box. 120mm(H) x 248mm(W) x 65mm(D).
ML2164/4W 4 gang wall box. 120mm(H) x 320mm(W) x 65mm(D).
ML2164/1W
ML2164/2W
ML2164/3W
ML2164/4W
GR
IDS
ML2
164
Seri
es
Gr ids
Features
Adjustable grid height to allow easy positioning of
accessories fl ush with the wall surface.
Provision for mounting segregation between gangs.
Electrical accessories mounted on 72mm centres.
Gas outlets mounted on 108mm centres.
Accommodates all Medilec ML2000 and Clipsal 2000
accessories, and OEM 2000 series nurse call systems
and gas outlets.
8
ML2164/1G ML2164/2G
ML2164/3G
ML2164/4G
ML2164/3G2
ML2164/2G2
GAS - 2000 SERIES
ML2164/2G2 2 gang 2000 series gas grid 117mm(H) x 244mm(W) x 12mm(D).
Suits 3 gang wall box.
ML2164/3G2 3 gang 2000 series gas grid 117mm(H) x 316mm(W) x 12mm(D).
Suits 4 gang wall box.
CATALOGUE NUMBER DESCRIPTION
STANDARD
ML2164/1G 1 gang grid 117mm(H) x 100mm(W) x 12mm(D).
ML2164/2G 2 gang grid 117mm(H) x 172mm(W) x 12mm(D).
ML2164/3G 3 gang grid 117mm(H) x 244mm(W) x 12mm(D).
ML2164/4G 4 gang grid 117mm(H) x 316mm(W) x 12mm(D).
CATALOGUE NUMBER DESCRIPTION
ML2
164 SeriesG
RID
S
9
EQUIPOTENTIAL JUNCTION
The Equipotential (EP) Junction is part of the EP Earth-
ing System (detailed in AS3003) that is used to protect
against micro shock in Cardiac Protected Areas. The EP
Earthing system decreases the resistance/potential differ-
ences between various Earthed points within the Cardiac
protected area.
ML2164E35G Equipotential Junction grid assembly 117mm(H) x 244(W)mm x 60mm(D).
Suits 3 gang wall box.
Features
Adjustable grid height to allow easy positioning of the
EP Junction fl ush with the wall surface.
1 x BP25 Line tap for bus termination.
4 x 8mm and 10 x 5mm diameter termination tunnels.
1 x EP Earth stud.
CATALOGUE NUMBER DESCRIPTION
ML2164E35G
FAC
IAS
ML2
164
Seri
es
10
ML2164/1F
Features
A choice of facia fi nishes and colours including
natural high grade stainless steel and powder-
coated fi nishes.
Electrical accessories mounted on 72mm centres.
Gas outlets mounted on 108mm centres.
Accommodates all Medilec ML2000 and Clipsal
2000 accessories, and OEM 2000 series nurse call
systems and gas outlets.
Facias
STANDARD
GAS - 2000 SERIES
EQUIPOTENTIAL JUNCTION
ML2164/2F2 2 gang 2000 series gas facia 150mm(H) x 280mm(W).
Suit 3 gang wall box.
ML2164/3F2 3 gang 2000 series gas facia 150mm(H) x 352mm(W).
Suit 4 gang wall box.
CATALOGUE NUMBER DESCRIPTION
ML2164E35F 1 gang EPJ facia 150mm(H) x 280mm(W).
Suit 3 gang wall box.
CATALOGUE NUMBER DESCRIPTION
ML2164/1F 1 gang facia 150mm(H) x 136mm(W).
ML2164/2F 2 gang facia
150mm(H) x 208mm(W). ML2164/3F 3 gang facia
150mm(H) x 280mm(W). ML2164/4F 4 gang facia
150mm(H) x 352mm(W).
CATALOGUE NUMBER DESCRIPTION
ML2164/2F
ML2164/3F
ML2164/4F
ML2164/2F2
ML2164/3F2
ML2164E34F
ML2
164 SeriesA
CC
ESSO
RIE
S
11
Customised Medilec Service Panels that are longer than
the standard 1 to 4 gang ML2164 components will typi-
cally be supplied pre-assembled from Clipsal Integrated
Systems (CIS) but it is possible for the customer to de-
velop their own customised panels by using the ML2164
Accessories.
Please note that if the customer is to develop their
own custom Medilec Service Panels, information must
be recorded and supplied to CIS that details the exact
positioning of wall boxes and facia mounting brackets.
This information is required so that a custom facia can
be manufactured.
Accessories
ML2164FMB Facia mounting bracket.
ML2164JP Wall box joining tray joiner plate.
ML2164JT Wall box joining tray 2400mm.
ML2164S Segregation.
CATALOGUE NUMBER DESCRIPTION
ML2164JT ML2164S
ML2164JP
ML2164FMB
NO
TES
ML2
164
Seri
es
12
NOTES
Products of Clipsal Integrated Systems Pty Ltd ABN 15 089 444 931
Head Offi ce 12 Park Terrace, Bowden South Australia 5007
PO Box 103, HindmarshSouth Australia 5007Telephone (08) 8269 0560International +61 8 8269 0560Facsimile (08) 8346 0845International +61 8 8346 0845Internet clipsal.com/cisE-Mail cis@clipsal.com.au
Offi ces in all StatesNSW Sydney (02) 9794 9200 Albury (02) 6041 2377VIC Melbourne (03) 9207 3200 Country Areas 1800 653 893QLD Brisbane (07) 3244 7444 Townsville (07) 4729 3333SA Adelaide (08) 8269 0555WA Perth (08) 9442 4444TAS Hobart (03) 6272 3177 Launceston (03) 6343 5900NT Darwin (08) 8947 0278
International Enquiries Head Offi ce Export DepartmentTelephone +61 8 8269 0587Facsimile +61 8 8340 7350E-Mail export@clipsal.com.au
International Representatives
New Zealand Clipsal Industries (NZ) Ltd (Auckland)Telephone (09) 576 3403 Facsimile (09) 576 1015E-Mail headoffi ce@clipsal.co.nz
Customer Service Free Fax (0508) 250 305Auckland/Mobile Phone (09) 572 0014Free Phone (0508) CLIPSAL
MalaysiaClipsal Malaysia Sdn BhdLot 26, Jalan Pengapit 15/19Shah Alam Industrial Estate 40000 Sham AlamSelangor Darul EhsanWest Malaysia, Malaysia Telephone +60 3 551 91111Facsimile +60 3 551 94378
Singapore Clipsal Singapore Pte Ltd No. 5, Fourth Chin Bee RoadSingapore 619699Telephone +65 415 3288Facsimile +65 415 3289E-Mail clipsal@cyberway.net.sg
Argentina Controles Tecnova SA Telephone (114) 207 9534
China Clipsal (China) Ltd Telephone (755) 246 1122
Greece Clipsal Hellas S.A. Telephone (1) 600 3718
Middle EastClipsal Middle East Telephone (6) 557 0777
South Africa Clipsal South Africa (Pty) Ltd Telephone (11) 314 5200
TaiwanClipsal (Taiwan) Co Ltd Telephone (2) 2558 3456
Thailand Clipsal Thailand Ltd Telephone (2) 952 5338
United Kingdom Clipsal Ltd (UK) Telephone (44) 1494 521111
Vietnam Clipsal - VTEC Telephone (8) 856 3002
© Copyright Clipsal Integrated Systems Pty Ltd 2001Printed by Custom Press Pty Ltd (08) 8346 7999O/N 0910 Sept 01/01
2547725
Recommended