SUBMITTAL AJ009NBNDCH/AA

www.SamsungHVAC.com888-699-6067

Page 1 of 2

Samsung FJM Series, Wind-Free™ Mini 4-Way Cassette

© 2019 Samsung HVAC SHA-FJM-03262019

Cooling (Btu/h) 8,900

Heating (Btu/h) 9,900

1 / 208-230 / 60

0.51

Turbo (1)

Type BLDC (1)

FLA / Output 0.17A / 24 W

Airflow CFM L/M/H 244 / 290 / 318

R410AElectronic Expansion Valve

(at outdoor unit)

Liquid (flare) Inches 1/4

Suction (flare) Inches 3/8

Drain Inches OD 1 1/4, ID 1

W X H X D Inches 22 5/8 X 10 X 22 5/8

Weight 25.40

Sound Level L / H dB(A) 24 / 33

Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

Piping Connections

Unit Dimensions

Fan

Type

Motor

RefrigerantType

Control Method

Specifications

Performance Nominal Capacity

PowerVoltage (ø/V/Hz)

Nominal Running Current (A)

lbs.

• Electro-static, washable, pleated filters as standard (included withfascia panel)

• Built in condensate pump with maximum 29" lift from the bottom of the unit, check valve, and float switch that disables indoor unit during overflow detection.

• Knock-out for outside air capability (with booster fan connection)

• Fascia panel shall have LED indicator lights, IR receiver, and 4motorized louvers with independent control.

• High-voltage terminal block temperature sensor to disable unit in theevent overheating of power connection.

• The indoor unit shall be powered by the outdoor unit

ConstructionGalvanized steel frame with HIPS chassis and fascia panel certified toUL94 V0.

Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

Indoor FanIndoor fan is a single turbo type

Three fan speed settings and auto setting

ControlsControl signal shall be a DDC type signal

Interconnect control wire between outdoor and indoor shall be 16AWGX 2 shielded

The system shall integrate with the Samsung Controls Solution.

CompatibilityWill only operate with Samsung outdoor unit model numbers:AJ020JCJ2CH/AA, AJ020MCS3CH/AA, AJ024JCJ3CH/AA,AJ024MCS4CH/AA, AJ030MCS4CH/AA, AJ036JCJ5CH/AA,

MIM-B14

MCR-SMD

AR-EH03U

MWR-WH00U

25' - ILS2506

50' - ILS5006

ETL (UL 1995)Safety Certifications

Line sets - insulated and flared, interconnect cables included

Accessories

External Contact Control

Motion Occupancy Sensor

Wireless Remote Controller

Standard Wired Controller

• Wind-Free™ function will close the supply air outlet louver while incooling mode to gently disperse cool air into the space withoutblowing directly onto occupants. The Wind-Free™ feature isoptional and can be enabled using central or local control options(MWR-WE13U, AR-EH03U only).

• The Wind-Free™ 4-way cassette can be configured for 2-stageoperation, cooling the space with the louver open (fixed or swing)until the room temperature nears set temperature. Once roomtemperature is near set temperature, Wind-Free™ operation will startautomatically, closing the louver and using the face of the fasciapanel to gently cool the space with still air*.

*The Wind-FreeTM unit delivers an air current that is under 0.15 m/s while in Wind Free mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers).

24 3/8 X 24 3/8 X 2 1/4

lbs.Weight 6

Fascia Panel1(purchased separately)

L X W X H(Inches) 24 3/8 X 24 3/8 X 2 3/16

PC4SUFMUN (Wind-Free™)PC4SUSMUN (Standard)

1PC4SUFMUN fascia panel must be installed to use the Wind-Free™ functions. MWR-WE13U wired controller or AR-EH03U wireless remote control must be used to enable Wind-Free™ functions.

The Wind-Free™ panel (PC4SUFMUN) has an integral humiditysensor that will open the louvers for standard cool mode when spaceconditions could potentially cause condensation formation on thepanel surface.

MWR-WE13UWired Controller W/Scheduling & Wind-Free™

PC4SUFMUN

PC4SUSMUN

Wind Free™ Fascia Panel

Standard Fascia Panel

59" or more

59" or more

59" or more

59" or more

www.SamsungHVAC.com

SUBMITTAL

Proper clearance must be maintained around unit for proper operation.

No. Name Description

1234567

Liquid Pipe ConnectionGas Pipe ConnectionDrain Pipe ConnectionConduit for Power & Communication WiringAir Inlet GrilleAir Outlet LouverFresh Air Intake

Ø 1/4" FlareØ 3/8" Flare

OD 1 1/4", ID 1"---

Ø 4"

Page 2 of 2 AJ009NBNDCH/AA Samsung FJM Series, Wind-Free™ Mini 4-Way Cassette

Ø4"

22 13/16 ~ 23 1/16" Ceiling Opening

19 13/16" Suspension Point

19 1

3/16

" Sus

pens

ion

Poin

t

22 1

3/16

~ 2

3 1/

16" C

eilin

g O

peni

ng

22 5/8" 22 5/8"

1 5/

8"9

1/4"

7 3/

16"

3 1/

8"

6 3/4"

3 1/8"

5 15/16"5 7/16"

M4 Screw

11 13/16" 5 7/16"

4 11

/16"

12 5

/16"

9 5/

8"

7/8" 7/8"

8 7/8"8 5/16"

2" 5 1/

2"

7 3/

8"

Max

imum

21

5/16

" fro

m d

rain

con

nect

ion

(Max

imum

29"

from

bot

tom

of u

nit)

8 1/

8"

6 1/2"

9 13/16"

10 9/16"

2 5/

8"

24 3/8"

15"

24 3

/8"

15"

7

1

3

24

6

5

PC4SUFMUN Panel(Wind-Free™)

Recommended