RELOCATED DUMPSTER Love FieldAirport - Dallas...20.85' 25.09' bollard 24.0' phase i...

Preview:

Citation preview

S

GA

SGAS

GAS

G

A

S

GAS

GAS

GASGAS

GASGAS

GAS

GASGAS

CO

MM

C

O

M

M COMMCOMM

CO

MM

C

O

M

M

CO

MM

EX. 3" GAS TO REMAIN

10

7

5

9

8

8

7

7

4

11

3

9

EX

. B

ILLB

OA

RD

24.0'

24.0'

24.0'

R

1

0

.

0

'

R

8

.

0

'

R

8

.

0

'

R

8

.

0

'

R

1

0

.

0

'

R

1

0

.

0

'

24.0'

12.0'

9.0'

27.0'

12.0'

5.0'

8.0'

9.0'

9.0'

9.0'

9.0'

24.0'

9.0'

18.0'

24.0'18.0'

24.0'

18.0'

43.5'

83.9'

R

3

0

.

0

' R

3

0

.

0

'

R

2

4

.

0

'

2.0'

143.0'

18.0'

18.0'

24.0'

7.0'

R

8

.

0

'

R

8

.

0

'

5.0

'

22.3'

147.5'

2.5'

R250.0'

R250.0'

R

8

.

0

'

R

1

0

.

0

'

R

8

.

0

'

R

8

.

0

'

R

2

.5

'

R

4

8

.

0

'

22.7'

2.0'

60.0'

R

8

.

0

'

R

1

0

.

0

'

81.0'

18.0'

9.0'

9.82'71.0'

14.0'

9.0'

24.0'

18.0'

18.0'

24.0'

9.7

'

9.0'

24.0'

14.47'

9.0'

9.0'

18.9'

EX. FH

EX. FH

R

8

.

0

'

R

1

0

.

0

'

23.61'

9.0'

18.0'

R

8

.0

'

R

5

.

0

'

R

8

.

0

'

24.0'

29.0'

65.53'

29.53'

3.0'

36.0'

99.0'

81.0'

27.0'

14.53'

R

1

0

.

0

'

7.44'

S44°37'11"E

200.00'

S46°27'54"W 56.54'

N45°34'23"W

27.73'

N45°34'23"W

336.95'

N45°16'38"E275.45'

S45°16'38"W

13.50'

S47°03'22"W

100.05'

S45°34'23"E

563.05'

S45°34'34"E

186.27'

S45°16'38"W 288.95'

N44°40'57"W

96.58'

N45°19'03"E

17.03'

N44°40'57"W

97.25'

N: 6988729.87

E: 2476828.46

N: 6988860.26

E: 2476695.44

N: 6988805.06

E: 2476671.05

EX. MH

EX. MH

EX. GI

EX.

EX. BFR

BFR

BFR

RETAINING

WALL

RETAINING WALL

DUMPSTERS

DUMPSTER

RELOCATED

FH

PROP. WE

BY PLAT

PROP. WE

BY PLATPROP. WE

BY PLAT

8.0'

8.0'

8.0'

9.0'

72.0'

R

1

0

.

0

'

32.40'

R

2

0

.

0

'

10.8'

R

2

.

0

'

83.42'

10.0'

2.0'

2.0'

4.0'

12.0'

12.0'

18.0'

18.0'

24.0'

63.0'

81.0'

16.0'

16.0'

14.0'

18.0'

1

5

.

0

'

1

2

.

0

'

1

5

.

0

'

1

2

.

0

'

6

.

5

'

10.0'

8.93'

20.85'

25.09'

BOLLARD

24.0'

PHASE I

USE: RETAIL

± 1.59 ACRES

MONUMENT SIGN

PERMITTED AREA

131.96'

S46°20'33"W 253.97

N45°19'03"E 250.83'

WE

ST

LO

VE

R

ET

AIL

PR

EP

AR

ED

F

OR

MO

CK

IN

GB

IR

D V

EN

TU

RE

PA

RT

NE

RS

, L

.L

.C

.

©

N

O

R

T

H

NOTES

TYP.TYPICAL

RRADIUS

FIRE HYDRANTFHPROPERTY LINE

PROPOSED FIRE HYDRANT

CURB INLETCI

PROPOSED BUILDING

AUEACCESS & UTILITY EASEMENT

ACCESSIBLE HANDICAP PARKING

SYMBOL

LINE NUMBER. REF LINE TABLE

LXX

CURVE NUMBER. REF CURVE TABLE

CXX

EEELECTRICAL EASEMENT

WEWATER EASEMENT

SESEWER EASEMENT

BFR BARRIER FREE RAMP

LEGEND

UEUTILITY EASEMENT

GIGRATE INLET

MHMANHOLE

SWITCH GEAR

TRANSFORMER

M

A

P

L

E

D

E

N

T

O

N

T

H

U

R

S

T

O

N

Love Field

Airport

F

O

R

E

S

T

P

A

R

K

M

O

C

K

I

N

G

B

I

R

D

H

A

W

E

S

H

A

W

E

S

C

E

D

A

R

S

P

R

I

N

G

S

E

M

P

I

R

E

C

E

N

T

R

A

L

H

A

R

R

Y

H

I

N

E

S

S

H

E

A

L

O

V

E

D

A

L

E

A

N

S

O

N

M

O

H

A

W

K

F

I

L

L

M

O

R

E

D

E

N

T

O

N

M

A

P

L

E

S

T

U

T

Z

K

I

M

S

E

Y

B

O

M

A

R

M

O

H

A

W

K

VICINITY MAP

N.T.S.

SITE

DEVELOPMENT PARKING DATA

PARKING REQUIRED:

PARKING PROVIDED:

ON-SITE PARKING

ADA PARKING

DEVELOPMENT SITE DATA

SITE AREA

1.59 AC. (69,214 S.F.)

OPEN SPACE

0.48 AC. ( 20,076 S.F.)

LOT COVERAGE RATIO

(MAX. 80%)

(69,214-20,076 S.F.) / 69,214 S.F. = 71%

GROSS SQUARE

FOOTAGE

9,938 S.F.

FLOOR AREA RATIO

(MAX 1.5)

83

40

TOTAL PARKING REQUIRED 43

NUMBER OF PARKING SPACES

9,938 S.F. / 69,214 S.F. = 0.136

BUILDING HEIGHTS

TOTAL PARKING PROVIDED 88

ADA PARKING 3

TOTAL ON-SITE PARKING

(4 SPOTS / 1000 SF)

5

TOTAL BUILDING

FOOTPRINT

0.68 AC. ( 9,938 S.F.)

(INCLUDING 1 ADA VAN SPOT)

PH

AS

E I

DE

VE

LO

PM

EN

TA

L P

LA

N

CAUTION!!

EXISTING UNDERGROUND UTILITIES IN THE AREA CONTRACTOR

IS RESPONSIBLE FOR DETERMINING THE HORIZONTAL AND

VERTICAL LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION.

CONTRACTOR SHALL BE RESPONSIBLE FOR ANY REPAIRS TO

EXISTING UTILITIES DUE TO DAMAGE INCURRED DURING

CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER OF

ANY DISCREPANCIES ON THE PLANS.

Know what'sbelow.

Call

Know what'sbelow.

before you dig.before you dig.

Know what'sbelow.

LA

ST

S

AV

ED

9/9

/2

01

9 4

:0

3 P

M

PL

OT

TE

D B

YF

LA

HE

RT

Y, C

AIT

LIN

9

/1

0/2

01

9 1

1:2

0 A

M

DW

G P

AT

HK

:\D

AL

_C

ivil\0

64

27

10

11

-M

ockin

gb

ird

M

ixe

d U

se

\0

64

27

10

13

-W

est L

ove

R

eta

il\C

AD

\P

la

nS

he

ets\L

OT

3

C-D

eve

lo

pm

en

t

DW

G N

AM

EC

-D

ev-L

ot3

C.d

wg

, [ D

IM

EN

SIO

N C

ON

TR

OL

P

LA

N ], S

he

et S

et [ S

et N

am

e ]

IM

AG

ES

XR

EF

S xB

ase

: xE

sm

t : xE

xU

til : xS

urv : xU

til-F

ra

nch

ise

: xS

sw

r : xS

trm

: xW

atr : xE

xU

til-F

ra

nch

ise

: xL

nd

scp

: xT

tlb

-L

ot3

C

311T

#-9221

Not for construction or permit purposes.

FOR REVIEW ONLY

Engineer

P.E. No. Date

DAVID. E MEYERS

81512 09/09/2019

26'-8'', 24'-0"

1. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED.

2. ALL CURB RADII ARE 2' UNLESS DIMENSIONED OTHERWISE.

ZONING CASE NO.: Z189-304

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

GAS

GA

SGAS

GAS

G

A

S

GAS

GASGAS

GASGAS

GAS

GASGAS

GASGAS

GAS

GAS

GASGAS

GASGAS

GA

S

GA

S

GASGAS

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

GA

S

COMMCOMM

CO

MM

C

O

M

M COMMCOMM

CO

MM

C

O

M

M

CO

MM

G

F

F

FEX. 3" GAS TO REMAIN

MOCKINGBIRD LANE

MA

PLE

A

VE

NU

E

EX. FH

EX. FH

EX. FH

N45°14'11"E325.77'

S44°37'11"E

200.00'

S46°27'54"W56.54'

S69°28'06"E

49.37'

N45°59'13"W

29.70'

N69°28'06"W

N45°34'23"W

27.73'

N45°34'23"W

336.95'

N45°16'38"E275.45'

S45°16'38"W

13.50'

S45°59'13"E

182.28'

S47°03'22"W

100.05'

S0°10'40"W

20.78'

S45°34'23"E

563.05'

S45°34'34"E

186.27'

∆=4°53'11"

R=242.50'

L=20.68'

CB=N47°12'07"E

C=20.67'

∆=4°19'40"

R=217.50'

L=16.43'

CB=N47°28'53"E

C=16.42'

S45°16'38"W 288.95'

N44°40'57"W

96.58'

N45°19'03"E

17.03'

N44°40'57"W

97.25'

82.56'

N: 6989291.77

E: 2477133.60

N: 6989165.12

E: 2477264.69

N: 6988729.87

E: 2476828.46

N: 6988860.26

E: 2476695.44

EX. BFR

EX. 7' SW

EX. 6' SW

6627 MAPLE AVENUE LLC

INST.NO. 201500213882

O.P.R.D.C.T.

GREENWAY-MOCKINGBIRD, L.P.

NO. 200600441187

O.P.R.D.C.T.

N: 6989144.34

E: 2477264.63

PHASE I

USE: RETAIL

± 1.59 ACRES

PHASE II

USE: RETAIL

±1.13 ACRES

15' FRONT-YARD SETBACK

5' F

RO

NT

-Y

AR

D S

ET

BA

CK

MONUMENT SIGN

PERMITTED AREA

131.96'

ACCESS POINT

ACCESS POINT

S46°20'33"W 247.67'

S45°19'03"W 204.03'

S46°20'33"W 253.97

N45°19'03"E 250.83'

WE

ST

LO

VE

R

ET

AIL

PR

EP

AR

ED

F

OR

MO

CK

IN

GB

IR

D V

EN

TU

RE

PA

RT

NE

RS

, L

.L

.C

.

©

N

O

R

T

H

NOTES

TYP.TYPICAL

RRADIUS

FIRE HYDRANTFHPROPERTY LINE

PROPOSED FIRE HYDRANT

CURB INLETCI

PROPOSED BUILDING

AUEACCESS & UTILITY EASEMENT

ACCESSIBLE HANDICAP PARKING

SYMBOL

LINE NUMBER. REF LINE TABLE

LXX

CURVE NUMBER. REF CURVE TABLE

CXX

EEELECTRICAL EASEMENT

WEWATER EASEMENT

SESEWER EASEMENT

BFR BARRIER FREE RAMP

LEGEND

UEUTILITY EASEMENT

GIGRATE INLET

MHMANHOLE

SWITCH GEAR

TRANSFORMER

M

A

P

L

E

D

E

N

T

O

N

T

H

U

R

S

T

O

N

Love Field

Airport

F

O

R

E

S

T

P

A

R

K

M

O

C

K

I

N

G

B

I

R

D

H

A

W

E

S

H

A

W

E

S

C

E

D

A

R

S

P

R

I

N

G

S

E

M

P

I

R

E

C

E

N

T

R

A

L

H

A

R

R

Y

H

I

N

E

S

S

H

E

A

L

O

V

E

D

A

L

E

A

N

S

O

N

M

O

H

A

W

K

F

I

L

L

M

O

R

E

D

E

N

T

O

N

M

A

P

L

E

S

T

U

T

Z

K

I

M

S

E

Y

B

O

M

A

R

M

O

H

A

W

K

VICINITY MAP

N.T.S.

SITE

CONCEPTUAL SITE DATA

PER IR ZONING

MAXIMUM F.A.R.

PER IR ZONING

CO

NC

EP

TU

AL

P

LA

N

CAUTION!!

EXISTING UNDERGROUND UTILITIES IN THE AREA CONTRACTOR

IS RESPONSIBLE FOR DETERMINING THE HORIZONTAL AND

VERTICAL LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION.

CONTRACTOR SHALL BE RESPONSIBLE FOR ANY REPAIRS TO

EXISTING UTILITIES DUE TO DAMAGE INCURRED DURING

CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER OF

ANY DISCREPANCIES ON THE PLANS.

Know what'sbelow.

Call

Know what'sbelow.

before you dig.before you dig.

Know what'sbelow.

LA

ST

S

AV

ED

9/9

/2

01

9 4

:0

3 P

M

PL

OT

TE

D B

YF

LA

HE

RT

Y, C

AIT

LIN

9

/1

0/2

01

9 1

1:2

0 A

M

DW

G P

AT

HK

:\D

AL

_C

ivil\0

64

27

10

11

-M

ockin

gb

ird

M

ixe

d U

se

\0

64

27

10

13

-W

est L

ove

R

eta

il\C

AD

\P

la

nS

he

ets\L

OT

3

C-D

eve

lo

pm

en

t

DW

G N

AM

EC

-D

ev-L

ot3

C.d

wg

, [ D

IM

EN

SIO

N C

ON

TR

OL

P

LA

N (2

) ], S

he

et S

et [ S

et N

am

e ]

IM

AG

ES

XR

EF

S xB

ase

: xE

sm

t : xE

xU

til : xS

urv : xU

til-F

ra

nch

ise

: xS

sw

r : xS

trm

: xW

atr : xE

xU

til-F

ra

nch

ise

: xL

nd

scp

: xT

tlb

-L

ot3

C

311T

#-9221

Not for construction or permit purposes.

FOR REVIEW ONLY

Engineer

P.E. No. Date

DAVID. E MEYERS

81512 09/09/2019

1. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED.

2. ALL CURB RADII ARE 2' UNLESS DIMENSIONED OTHERWISE.

MAXIMUM STRUCTURE HEIGHT

ZONING CASE NO.: Z189-304

Recommended