PTA REFERENCE GUIDEThe Pocket Guide to Our Market-Leading Balloons Portfolio
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AA
BOSTON SCIENTIFIC OFFERS COMPLIANT AND NON-COMPLIANT PTA
Non-Compliant Balloon• Retains shape
• Transmits greater dilating force at the lesion
• ~4-6% growth within the working range when inflated
Compliant Balloon• Hourglasses or “dog-bones” around lesion
• Provides less dilating force at the lesion
• ~8-10% growth within the working range when inflated
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BALLOON CATHETER DESIGN
Over-the-Wire Balloon Catheter
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Distal Bond Profile
Tip Entry Profile
Tapered Tip
Proximal Balloon ProfileLargest outer diameterat the proximal balloon cone
Balloon Materials and Design
Shaft
Inflation Port
Wire Port
Hub
Distal Balloon ProfileLargest outer diameter at the distal balloon cone
Distal Bond Profile
Tapered Tip
Balloon Materials and Design
Shaft
Inflation Port
Rapid-Exchange Guidewire Port
Distal Balloon ProfileLargest outer diameterat the proximal balloon cone
Proximal Balloon ProfileLargest outer diameter at the proximal balloon cone
Hub
Monorail™ Balloon Catheter
BALLOON CATHETER DESIGN
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Tip Entry Profile
BalloonDiameter
(mm)
Balloon Length (mm)
20 30 40 60 80 100
4.0 40 atm 40 atm 40 atm 40 atm 40 atm
5.0 40 atm 40 atm 40 atm 40 atm 40 atm
6.0 40 atm 40 atm 40 atm 40 atm 40 atm
7.0 34 atm 34 atm 34 atm 34 atm 34 atm
8.0 31 atm 31 atm 31 atm 31 atm 31 atm 31 atm
9.0 30 atm 30 atm 30 atm
10.0 30 atm 30 atm 27 atm
12.0 20 atm 20 atm 20 atm
ATHLETIS™ ULTRA-HIGH-PRESSURE BALLOON
8F6F 7F
Ultra-High pressures up to 40 ATM
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Why Athletis
Breakthrough Ultra-Low Tip Profile
• Class-leading 0.042” tip entry profile*
• Designed to promote crossability through tight stenosis
• Designed to facilitate atraumatic lesion entry
Exceptional Trackability
• Smooth, seamless tip-to-shaft transitions designed to enhance trackability
• Balloon and shaft design promote navigation through tortuous vasculature
Dilatation Efficiency
• Proprietary braided balloon design enables optimized deliverability and ultra-high pressures
• Ultra-low growth beyond stated diameter of <2% even at pressure up to 40 ATM
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
20 – 200 mm 8 ATM Up to 40 ATM Pebax™ 0.042"50 cm, 75 cm,
135 cm
ATHLETIS™ ULTRA-HIGH-PRESSURE BALLOON
1
2
3
Ultra-High Pressure. Ultra-Low Profile. 0.035
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
ATHLETIS™ VS. COMPETITORS
Trackability 28% lower force than Conquest
350
300
250
200
150
100
50
0
(Bench Test)
Trac
kab
ility
(p
eak
inp
ut
forc
e, g
ram
s)
Athletis™ Conquest 40™ Conquest™
All products 8 x 40 mm balloons. Average measurements taken by Boston Scientific (n = 3). Data on file (TR 92200478).Bench test results may not necessarily by indicative of clinical performance.
S-track Test: Measure of shaft’s ability to maneuver through a tortuous artery model.
255 grams
304 grams
327 grams
Low
er
is P
refe
rre
dBoston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
ATHLETIS™ VS. COMPETITORS
Lower compliance compared to Conquest and Conquest 40
*Data from Conquest 40 brochure
Soft Block Test: Measure of balloon’s ability to fully open a resistant lesion model.
All products 8 mm balloons. Average measurements taken by Boston Scientific (n = 15). Data on file (TR 92200478).Bench test results may not necessarily by indicative of clinical performance.
2.5
2
1.5
1
0.5
0
(Bench Test)
Ave
rag
e C
om
plia
nce
(%
)
Athletis™ Conquest™ Conquest™ 40
1.71% 2.2%* 1.22%
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20 30 40 60 80 100 120 150 180 200
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
12.0
MUSTANG™ BALLOON DILATATION CATHETER
5F 6F 7F
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
20 – 200 mm10 ATM (3-8, 12 mm)
8 ATM (9-10 mm)Up to 24 ATM NyBax™ 0.040"
40 cm, 75 cm, 135 cm
MUSTANG™ BALLOON DILATATION CATHETER
1
2
3
Why Mustang
Deliverable High Pressure
24 atmosphere rated burst pressure with a low profile. Nybax balloon material enables great trackability and high pressure in the same balloon.
Broadest Size MatrixBalloon lengths of 20-200 mm. Diameters from 3-12 mm. Available in 40 cm, 75 cm, and 135 cm shaft lengths.
Low ProfileLesion entry only 15% larger than the guidewire. 7 x 200 through 5F, 10 x 80 through 6F.
Excellence on Every Dimension 0.035
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
MUSTANG™ VS. COMPETITORS
Pushability1100
1050
1000
950
900
850
800
750
700
(Bench Test)
Pu
sh R
esp
on
se (
g/c
m)
Mustang™ Dorado™ PowerFlex™P3
Ultra-thin™Diamond™
AdmiralXtreme™
Conquest™ FoxCross™ EverCross™
All products 6x40 mm balloons.Average measurements taken by Boston Scientific (n=3). Data on file. (test 90143171).Bench testing may not be representative of clinical performance.
Push Response Test: Measure of shaft’s ability to transmit force to distal tip in straight-line configuration.
Hig
he
r is
Pre
ferr
ed
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
MUSTANG™ VS. COMPETITORS
Trackability
350
300
250
200
150
100
50
0
(Bench Test)
Trac
k (p
eak
inp
ut
forc
e, g
)
Mustang™ EverCross™ FoxCross™ AdmiralXtreme™
PowerFlex™
P3Ultra-thin™Diamond™
Conquest™ Dorado™
S-track Test: Measure of shaft’s ability to maneuver through a tortuous artery model.
All products 6x40 mm balloons.Average measurements taken by Boston Scientific (n=3). Data on file. (test 90555708).Bench testing may not be representative of clinical performance.
Low
er
is P
refe
rre
d
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20 30 40 60 80 100 120 150 180 200
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
12.0
CHARGER™ BALLOON DILATATION CATHETER
5F 6F 7F
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Why Charger
Post-Stent Dilatation Higher pressure when needed (up to 20 atm for 5 x 200 mm). Non-compliant for excellent stent-to-wall apposition.
Broad Size Matrix Balloon lengths of 20-200 mm. Diameters from 3-12 mm. Available in 40 cm, 75 cm, and 135 cm shaft lengths.
Low Profile0.040" tip over a 0.035" guidewire. 6 x 150 mm and 7x80 mm through 5 F. 10 x 80 mm through 6 F. Excellent rewrap.
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
20 – 200 mm10 ATM (3-8, 12 mm)
8 ATM (9-10 mm)Up to 20 ATM NyBax™ 0.040"
75 cm, 135 cm
CHARGER™ BALLOON DILATATION CATHETER
1
2
3
Count On It 0.035
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
1100
1050
1000
950
900
850
800
750
700
(Bench Test)P
ush
Re
spo
nse
(g
/cm
)
Charger™ PowerFlex™P3
Ultra-thin™Diamond™
AdmiralXtreme™
FoxCross™ EverCross™
CHARGER™ VS. COMPETITORS
Pushability
Push Response Test: Measure of shaft’s ability to transmit force to distal tip in straight-line configuration.
All products 6x40 mm balloons. Average measurements taken by Boston Scientific (n=3). Data on file. (test 90143171). Bench testing may not be representative of clinical performance
Hig
he
r is
Pre
ferr
ed
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
CHARGER™ VS. COMPETITORS
Withdrawal
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
Through a 5 F Sheath(Bench Test)
Wit
hd
raw
al F
orc
e (
lbs)
Charger™ AdmiralXtreme™
EverCross™ PowerFlex™ P3
FoxCross™
All products 6x40 mm balloons. Average measurements taken by Boston Scientific (n=3). Data on file (90137811). Bench testing may not be representative of clinical performance.
Low
er
is P
refe
rre
d
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20 40 60 80
4.0
5.0
6.0
7.0
8.0
9.0
10.0
12.0
GLADIATOR™ ELITE BALLOON DILATATION CATHETER
5F 6F 7F
OBL ONLY
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
20 – 80 mm10 ATM (3-8, 12 mm)
8 ATM (9-10 mm)Up to 24 ATM PeBax™ 0.037"
40 cm, 75 cm
Why Gladiator Elite
Deliverable High Pressure
24 atmosphere rated burst pressure with a low profile. Non-compliant.
Durable DesignInnovative tri-layer balloon technology for enhanced durability in challenging lesions.
Low Profile0.037" tip over a 0.035" guidewire. 7 x 80 mm through 5 F. 10 x 80 mm through 6 F.
1
2
3
GLADIATOR™ ELITE BALLOON DILATATION CATHETER
Powerful Dilatation with Agility 0.035
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
(Bench Test)
Gladiator™ Elite Ultra-thin™Diamond™
Blue Max™ Conquest™ Dorado™
GLADIATOR™ ELITE VS. COMPETITORS
Trackability
S-track Test: Measure of shaft’s ability to maneuver through a tortuous artery model.
All products 6 x 40 mm balloons.Average measurements taken by Boston Scientific (n = 3). Data on file (TR 90909453).Bench test results may not necessarily be indicative of clinical performance.
350
300
250
200
150
100
50
0
Trac
k (p
eak
inp
ut
forc
e, g
)
Low
er
is P
refe
rre
d
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
GLADIATOR™ ELITE VS. COMPETITORS
Withdrawal
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Through a 6 F Sheath(Bench Test)
Wit
hd
raw
al F
orc
e (
lbs)
Gladiator™ Elite Ultra-thin™Diamond™
Conquest™ Dorado™ Blue Max™
Low
er
is P
refe
rre
d
All products 6 x 40 mm balloons. Average measurements taken by Boston Scientific (n = 3). Data on file (TR 90909453). Bench test results may not necessarily be indicative of clinical performance.
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20 40 60
12.0
14.0
16.0
18.0
XXL™ BALLOON DILATATION CATHETER
7F
*16-18 mm - Indicated for Esophageal Procedures Only
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Available Shaft Lengths
20 –60 mm8 ATM (13-14 mm)5 ATM (16-18 mm)
Up to 8 ATM Selar™75 cm, 120 cm
XXL™ BALLOON DILATATION CATHETER
Trusted Strength
Why XXL
Low Profile12 mm and 14 mm diameter balloons compatible with 7F sheaths.
Non-Compliant Design
Strong material designed to enhance radial force without deformation for a predictable balloon diameter
Superb Pushability and Trackability
Quadra-Fold technology for tight rewrapping of balloon around catheter shaft for a low deflated profile.
1
2
3
0.035
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
10 15 20 30 40 60 80 100 120 150 200 220
2.02.53.03.54.04.55.05.56.06.57.08.09.010.0
STERLING™ AND STERLING™ SL BALLOON DILATATION CATHETER
STERLING OTW & MR
5F4F4F6F5F4F
STERLING OTW STERLING MR
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
10 – 220 mm 6 ATM Up to 14 ATM Pebax™ 0.020"40 cm, 80 cm, 90 cm, 135 cm,
150 cm
Demand More
Why Sterling
Breakthrough Deliverability
Laser-bonded, tapered tip designed to promote crossability through tight stenosis and near occlusions. Semi-compliant Pebax balloon material.
Broadest Size Matrix The most comprehensive size offering available in both over-the-wire and monorail rapid-exchange. Indicated for wider acute use including carotid.
Low Profile Exceptionally low 0.020" lesion entry profile on a 0.018" guidewire. 7 x 220 mm through 5F. Flexible tip promotes easy navigation through tortuous vasculature.
1
2
3
STERLING™ AND STERLING™ SL BALLOON DILATATION CATHETER
0.018
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
STERLING™ VS. COMPETITORS
Tip Entry Profile
0.035
0.03
0.025
0.02
0.015
0.01
(Bench Test)P
rofi
le (
inch
es)
Sterling™ PowerCross™ Pacific™
XtremeUltraverse™
018Savvy™ Long
Low
er
is P
refe
rre
d
Tip entry measurements performed at the distal-most portion of the tip. Average measurements taken by Boston Scientific (n=3, 5 mm x 150 mm balloons). Data on file. (TR 90884555). Bench testing may not be representative of clinical performance.
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
(Bench Test)
Sterling™ Ultraverse™
018Savvy™ Long Pacific™ Xtreme PowerCross™
STERLING™ VS. COMPETITORS
Trackability
S-track Test: Measure of shaft’s ability to maneuver through a tortuous artery model.
Tip entry measurements performed at the distal-most portion of the tip. Average measurements taken by Boston Scientific (n=3, 5 mm x 150 mm balloons). Data on file. (TR 90884555). Bench testing may not be representative of clinical performance. All photographs are property of Boston Scientific.
240
220
200
180
160
140
120
100
Trac
k (p
eak
inp
ut
forc
e, g
)
Low
er
is P
refe
rre
d
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20 30 40 60 80 100 120 150 220
1.5
2.0
2.5
3.0
3.5
4.0
COYOTE ES OTW & MR COYOTE OTW & MR
COYOTE™ AND COYOTE™ ES BALLOON DILATATION CATHETER
4F4F
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Tip Profile
Available Shaft Lengths
20 – 220 mm8 ATM (Coyote)
6 ATM (Coyote ES)Up to 14
ATMNyBax™ 0.017"
90 cm, 142 cm, 143 cm, 144 cm, 145 cm, 146 cm, 150 cm
COYOTE™ AND COYOTE™ ES BALLOON DILATATION CATHETER
Get To. Get Through. Get Going.
Why Coyote
Fast Deflation Deflation time of less than 10 seconds.
Excellent Trackability Available in four configurations: over-the-wire and Monorail platforms on 90 cm and 150 cm shaft lengths optimized for maximum push and excellent track.
Low Profile Ultra-low 0.017" lesion entry profile and best-in-class 0.030" crossing profile.
1
2
3
0.014
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
COYOTE™ VS. COMPETITORS
Pushability
800
700
600
500
400
300
200
(Bench Test)P
ush
Re
spo
nse
(g
/cm
)
Coyote™ Sleek™ NanoCross™ AmphirionDeep™
SAVVY™Long
Ultraverse™
014Armada™ 14
Average measurements taken by Boston Scientific (n=3, 2 mm x 120 mm balloons). Data on file (TM 90110865, 90226022, 90143171, 90483622). Bench test results may not necessarily be indicative of clinical performance.
Push Response Test: Measure of shaft’s ability to transmit force to distal tip in straight-line configuration.
Hig
he
r is
Pre
ferr
ed
OTW
Mo
no
rail™
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
COYOTE™ VS. COMPETITORS
Trackability
40
36
32
28
24
20
(Bench Test)Tr
ack
(pea
k in
pu
t fo
rce,
g)
Coyote™ SAVVY™Long
Sleek™ Ultraverse™
014Armada™ 14 Amphirion
Deep™NanoCross™
Average measurements taken by Boston Scientific (n=3, 2 mm x 120 mm balloons). Data on file (TM 90110865, 90226022, 90143171, 90483622). Bench test results may not necessarily be indicative of clinical performance.
S-track Test: Measure of shaft’s ability to maneuver through a tortuous artery model.
Low
er
is P
refe
rre
d
OTW
Mo
no
rail™
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
BalloonDiameter
(mm)
Balloon Length (mm)
20
5.0
6.0
7.0
8.0
PERIPHERAL CUTTING BALLOON™MICROSURGICAL DILATATION DEVICE FOR HEMODIALYSIS ACCESS MANAGEMENT
7F6F
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Available Balloon Lengths
Nominal Pressure
Rated Burst Pressure
Balloon Material
Available Shaft Lengths
20 mm 6 ATM Up to 10 ATMPolyethlene Terapthalate
(PET)
50 cm, 90 cm, 135 cm
The Proven Solution
Why Peripheral Cutting Balloon
Controlled Dilatation Designed for predictable, controlled dilatation.
Superior Results Over POBA
63% 12-month primary patency using PCB in arteriovenous stenosis vs 37% 12-month primary patency for conventional PTA.
Superior Results Over High Pressure PTA
66% 6-month primary patency using PCB in arteriovenous stenosis vs 40% 6-month primary patency for high pressure PTA.
1
2
3
0.018
PERIPHERAL CUTTING BALLOON™MICROSURGICAL DILATATION DEVICE FOR HEMODIALYSIS ACCESS MANAGEMENT
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
ENCORE™ 26 INFLATOR
• Sold individually or a box of 5
• Inflates up to 26 ATMs
• 20 ml Inflation capability, complete with pressure gauge
• Large printed pressure gauge dial with finger latch mechanism for 1-step locking and pressure release
The Encore 26 Inflation Device is recommended for use with balloon dilatation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
ENCORE™ 40 INFLATOR
• Inflates up to 40 ATMs
• 25 cc capacity, complete with pressure gauge
• Large printed pressure gauge that glows in the dark for easy reading in dark labs
• Quick latch mechanism allows for rapid deflation, even from max pressure.
• Clear barrel provides a precise view of the content and volume allowing user to perform thorough purging.
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
PTA SUPPORT
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. PI-630014-AB
Bre
adth
an
d D
epth
of
Pro
du
cts
We believe the best way to help our customers achieve the patient outcomes they’re looking for is to provide best-in-class support and service.
Customer Satisfaction
Our balloons portfolio is the ideal balance between highest quality PTA products and market-leading breadth of offerings.
Peripheral Interventions300 Boston Scientific WayMarlborough, MA 01752-1234www.bostonscientific.com
To order product or for more informationcontact customer service at 1.888.272.1001.
© 2020 Boston Scientific Corporationor its affiliates. All rights reserved.
PI-630014-AB
Boston Scientific Confidential. For Internal Use Only. Do Not Copy, Display or Distribute Externally. Mustang, Charger, Gladiator Elite, XXL, Sterling and Peripheral Cutting Balloon are registered or unregistered trademarks of Boston Scientific Corporation or its affiliates. All other trademarks are property of their respective owners.
Recommended