8/6/2019 Project Comparison
1/46
Edition 08/2008
SIMOTION
Project comparison
Function Manual
s
Preface, Contents
Overview of project comparison1
General information about object comparison2
Functions3
Overview of comparison attributes4
Index
http://-/?-http://-/?-http://-/?-http://-/?-8/6/2019 Project Comparison
2/46
Copyright Siemens AG 2008 All Rights Reserved
The reproduction, transmission or use of this document or its contentsis not permitted without express written authority. Violation of this rulecan lead to claims for damage compensation. All rights reserved, es-pecially for granting patents or for GM registration.
Siemens AGAutomation & DrivesMotion Control SystemsPO Box 3180, D-91050 ErlangenGermany
Disclaimer of liability
We have checked that the contents of this document correspond tothe hardware and software described. Since variance cannot be pre-cluded entirely, we cannot guarantee full consistency. The data in thisdocument is regularly checked and the necessary corrections are in-cluded in subsequent editions.
Siemens AG 2008Subject to change without prior notice
Safety Guidelines
This manual contains notices you have to observe in order to ensure your personal safety, as well as to
prevent damage to property. Notices referring to your personal safety are highlighted in the manual by a
safety alert symbol; notices referring to property damage only have no safety alert symbol. The notes
shown below are graded according to the level of danger in downward sequence:
If more than one level of danger exists, the warning notice for the highest level of danger is used. A warn-
ing with a warning triangle indicating possible injury to personnel may also include a warning relating to
property damage.
Qualified personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning
and operation of a device/system may only be performed by qualified personnel. Within the context ofthe safety notes in this documentation qualified persons are defined as persons who are authorized to
commission, ground and label devices, systems and circuits in accordance with established safety prac-
tices and standards.
Intended purpose
Please note the following:
Trademarks
All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights
of the owner.
Danger
indicates that death or serious injury will result if proper precautions are not taken.
Warning
indicates that death or serious injury may result if proper precautions are not taken.
Caution
with a safety alert symbol, indicates that minor personal injury may result if proper precautions are not
taken.
Caution
without a safety alert symbol, indicates that damage to property can result if proper precautions are not
taken.
Notice
indicates that an unintended result or situation may occur if the corresponding information is not taken into
account.
Warning
This device may only be used for the applications described in the catalog or the technical description and
only in conjunction with devices or components from other manufacturers which have been approved or
recommended by Siemens.
Correct transport, storage, installation and assembly, as well as careful operation and maintenance, are
required to ensure that the product operates safely and without faults.
Siemens Aktiengesellschaft SIMOTION Project comparison
8/6/2019 Project Comparison
3/46
Preface-3 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Preface
This document is part of the SIMOTION System and Function Descriptionsdocumentation package.
SIMOTION Documentation
An overview of the SIMOTION documentation can be found in a separate list ofreferences.
This document is supplied in electronic format with SIMOTION SCOUT.The SIMOTION documentation consists of 9 documentation packages containingapproximately 75 SIMOTION documents and documents on related systems (e.g.SINAMICS).
The following documentation packages are available for SIMOTION V4.1 SP2:
SIMOTION Engineering System
SIMOTION System and Function Descriptions
SIMOTION Diagnostics
SIMOTION Programming
SIMOTION Programming - References
SIMOTION C
SIMOTION P350
SIMOTION D4xx
SIMOTION Supplementary Documentation
Hotline and Internet addresses
Technical support
If you have any technical questions, please contact our hotline:
Europe / Africa
Phone +49 (0) 180 5050 222 (subject to charge)
Fax +49 (0) 180 5050 223
Internet http://www.siemens.de/automation/support-request
http://www.siemens.de/automation/support-requesthttp://www.siemens.de/automation/support-request8/6/2019 Project Comparison
4/46
Preface
Preface-4 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Questions about this documentation
If you have any questions (suggestions, corrections) regarding this documenta-tion, please fax or e-mail us at:
Siemens Internet address
The latest information about SIMOTION products, product support, and FAQscan be found on the Internet at
Americas
Phone +1 423 262 2522
Fax +1 423 262 2200
E-mail techsupport.sea@siemens.com
Asia / Pacific
Phone +86 1064 719 990
Fax +86 1064 747 474
E-mail adsupport.asia@siemens.com
Note:
Country-specific telephone numbers for technical support are provided under thefollowing Internet address:
http://www.siemens.com/automation/service&support
Calls are subject to charge (e.g. 0.14 /min on the German landline network). Tar-iffs of other phone companies may differ.
Fax: +49 9131 / 98 - 63315
E-mail: mailto: docu.motioncontrol@siemens.com
General information:
http://www.siemens.de/simotion (German)
http://www.siemens.com/simotion (International)
Product support:
http://support.automation.siemens.com/WW/view/de/10805436
mailto:techsupport.sea@siemens.commailto:adsupport.asia@siemens.comhttp://www.siemens.com/automation/service&supportmailto:docu.motioncontrol@siemens.comhttp://www.siemens.de/simotionhttp://www.siemens.com/simotionhttp://support.automation.siemens.com/WW/view/de/10805436mailto:docu.motioncontrol@siemens.comhttp://www.siemens.com/automation/service&supportmailto:adsupport.asia@siemens.comhttp://support.automation.siemens.com/WW/view/de/10805436http://www.siemens.com/simotionhttp://www.siemens.de/simotionmailto:techsupport.sea@siemens.com8/6/2019 Project Comparison
5/46
Preface
Preface-5 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Further support
We also offer introductory courses to help you familiarize yourself with SIMO-TION.
Please contact your regional training center or the central training center in D-90027 Nuremberg, phone +49 (911) 895 3202 for more information.
8/6/2019 Project Comparison
6/46
Preface
Preface-6 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
8/6/2019 Project Comparison
7/46
Contents-7 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Contents
Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preface-3
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents-7
1 Overview of project comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
2 General information about the object comparison . . . . . . . . . . . . . . . . . . . . . 2-11
2.1 The user interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
2.2 Comparison icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
2.3 Comparison tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
2.4 Comparison attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
2.5 Object attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
3 Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
3.1 Downloading additional data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
3.2 Starting the object comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
3.3 Assignment of objects in object comparison . . . . . . . . . . . . . . . . . . . . . 3-203.3.1 Manual selection of comparison objects . . . . . . . . . . . . . . . . . . . . . . . . 3-203.3.2 Automatic assignment of the subordinate comparison objects . . . . . . . 3-203.3.3 Changing the object address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.4 Detailed comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-233.4.1 Starting the detailed comparison. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-233.4.2 ST detailed comparison. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-233.4.3 TO/DO detail comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
3.5 Data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
4 Overview of comparison attributes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.1 SIMOTION objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4.2 SINAMICS objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
4.3 MICROMASTER and SINAMICS G120 objects . . . . . . . . . . . . . . . . . . 4-43
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-45
8/6/2019 Project Comparison
8/46
Contents
Contents-8 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
8/6/2019 Project Comparison
9/46
1-9 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Overview of project comparison 1You can use the SIMOTION SCOUT/Starter function Project comparison (startusing Start object comparison button) to compare objects within the sameproject and/or objects from different projects (online or offline) with one another.Objects are devices, programs, technology objects (TOs) or drive objects (DOs)and libraries. The project comparison is available to you under SIMOTIONSCOUT and Starter. Comparing projects helps you in the event of service workon the system.
Cases may occur for example where inconsistencies are indicated when chang-ing into online mode in the project navigator, i.e. there are deviations betweenyour project in the SCOUT and the project loaded in the target system. Possiblecauses for this are e.g.:
A program has been changed
The result of compiling a program is different
There is a deviation on the global device variables
The execution system has been changed
The hardware configuration has changed
An ST program in a library has been changed
A piece of configuration data for an axis has been changed
The object comparison allows you to establish these differences and if necessaryrun a data transfer to rectify the differences. The following comparisons are pos-sible:
Offline object with offline object from the same project
Offline object with offline object from a different project
Offline object with online object (not for libraries)
The first comparison partner (the reference object) is in the open project while thesecond partner (the comparison object) can be a comparison object in the openproject, in a different project or the online partner.
Note
A comparison with online objects is only possible if there is already an online con-nection. No implicit connection is established when the comparison is started!
8/6/2019 Project Comparison
10/46
Overview of project comparison
1-10 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
The highest level for a comparison is a device, not the project. The comparisoncan be started via
a SIMOTION device,
a drive unit or
a library.
A detailed comparison is available of the individual objects for ST programs, DOs
(drive objects) and TOs (technology objects).
Note
When comparing with another project, this must be at least in SIMOTIONSCOUT/Starter version 4.1. Otherwise you will first have to convert the project.
The project comparison function is also available when using devices with olderfirmware versions if you have edited or converted the project with SIMOTIONSCOUT or Starter V4.1 SP2. The project then has to be recompiled and loaded.
8/6/2019 Project Comparison
11/46
2-11 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
General information about object comparison 2Below you will find an overview of the elements and structure of the object com-parison dialog. You can start the detailed comparison for ST programs, TOs andDOs from this dialog.
2.1 The user interface
A user interface in which the differences in the various objects have beendetected was selected by way of example for the following screenshot. If workingwith programs, all the data from this user interface could be transferred and adetailed comparison would be possible for two programs.
Fig. 2-1 SIMOTION object comparison
8/6/2019 Project Comparison
12/46
General information about object comparison
2-12 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Table 2-1 The user interface elements of the object comparison
No. Description
1 Comparison partner A and comparison partner B
2 Comparison tree made up of comparison partner elements.
3 Object present (column A, column B):
You can see in the columns whether a tree object is present for comparison part-
ner A and/or comparison partner B or not.
4 Result of comparison:
The comparison result is shown in this column (same/different).
(See Comparison icons on page 2-13)
5 Select/change comparison partner
6 Update comparison
7 Call up online help8 Display object attributes (See Object attributes on page 2-16)
The attributes of the comparison partners are compared in two columns.
9 Start a detailed comparison
10 Comparison attributes of one object (See Comparison attributes on page 2-15)
11 Data transfer:
Transfer of data from comparison partner B into the open project.
12 Status bar
13 Object comparison tab
8/6/2019 Project Comparison
13/46
8/6/2019 Project Comparison
14/46
General information about object comparison
2-14 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
2.3 Comparison tree
The way in which the comparison tree is depicted is oriented towards the waytrees are depicted in the project navigator. Depiction of the comparison attributes
is added to the comparison tree. (See Overview of comparison attributes onpage 4-33)
Onetree is produced from the two trees/sub-trees of the comparison partners. Ifit has been possible to assign two of the comparison partners' objects, there isoneentry in the tree, columns 'A' and 'B' feature the symbol for 'Object present'.If it has not been possible to assign any comparison partners, the symbol 'Objectpresent' or 'Object not present' is shown in the corresponding column dependingon whether it belongs to comparison partner A or comparison partner B (seeexample below).
Fig. 2-2 Example of merging comparison partners
If an object is only present for one comparison partner, no comparison attributesare shown in the tree. Subordinate folders and objects are shown.
If the comparison partners are different , the tree is shown expanded. This givesyou a quick overview of the differences.
The comparison tree shows a snapshot. As a result of changes in the openproject, the comparison status may no longer be up-to-date. You are informed ofthis status in the status bar: The comparison is no longer up-to-date.
Since the comparison tree is not automatically updated, you have to explicitlystart the update by clicking on the Update button.
Note
You will find more information on assigning objects in the chapter Assignment ofobjects in object comparison, page 3-20.
8/6/2019 Project Comparison
15/46
General information about object comparison
2-15 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
2.4 Comparison attributes
In order to be able to analyze the differences when comparing objects, there area series of comparison attributes per object type which structure an object into
smaller units (comparison features) and in total contain all the object's data of rel-evance to the process.
You will already be familiar with some of the comparison attributes from theproject navigator (e.g. global device variables). In addition to this, there are newattributes which can contain various pieces of data, such as the compilation resultfor programs, and these also contain the global and local compiler settings.
You will find an overview of the specific comparison attributes for SIMOTION,SINAMICS and MICROMASTER objects in chapter Overview of comparisonattributes.
To enable the attributes to be compared as efficiently as possible, information iscalculated, e.g. a check sum, which is stored along with the project or objects, and
online too. If this information is not available (e.g. with the hardware configura-tion), a statement on the comparison cannot be made (indicated in the compari-son tree by ?).
You can start a detailed comparison for comparison attributes if you find differ-ences. The detailed comparison is available for
ST programs,
TOs (configuration data, system variables) and
DOs (parameters).
You can compare and transfer the content of data in the detailed comparison.
8/6/2019 Project Comparison
16/46
General information about object comparison
2-16 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
2.5 Object attributes
You can select the following object attributes in the two right-hand columns in theobject comparison.
Table 2-3 Object attributes
Name Description
Name Name of the object1
1 from the Object properties dialog.
Object address Unique object address 1
You need the object address e.g. to address the objects via
the HMI.
Author Name of the author1
Version external External version code1
Version internal Internal version code of object, e.g. for TOs, the technologypackage version
Creation version SIMOTION SCOUT version with which the object was cre-
ated
Time stamp of last
change
Date and time of last change
Comment Comment 1
8/6/2019 Project Comparison
17/46
3-17 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Functions 33.1 Downloading additional data
To enable you to run a detailed comparison and if necessary a complete datatransfer into PG/PC during an offline/online comparison, when downloading theproject onto the target device, you must also save the additional data, e.g.sources, symbol information etc. This is a setting in the SIMOTION SCOUT.
Procedure
Proceed as follows:
1. Select the Options > Settings menu command. The Settings windowappears.
2. Switch to the CPU-Download tab.
3. Activate Save additional data on the target device and confirm using OK.
The next time the project is downloaded to the target device, the additional datais saved on the target device. If deactivated, the additional data is deleted whennext downloading to the target device.
3.2 Starting the object comparison
The object comparison is only undertaken using saved data. In contrast, thedetailed comparison uses the data in the work memory of the PC/PG. The objectand detailed comparisons may therefore result in different results.
You must note the following during an online comparison and a compari-son with a different project:
The comparison only uses the saved data in the open project.
During an online comparison the device you are comparing with is implicitlyuploaded. The comparison is therefore made with a copy of the online data.
Note
The downloading of additional data is also available when using devices witholder firmware versions if you have edited or converted the project with SIMO-TION SCOUT or Starter V4.1 SP2. The project then has to be recompiled andloaded.
8/6/2019 Project Comparison
18/46
Functions
3-18 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Starting object comparison and selecting comparison partners
How to start the object comparison:
1. Click on the device with which you want to run the comparison in the projectnavigator.
2. Either start the object comparison via
the menu bar using Options > Compare...,
the button Start object comparison or
the context menu for the comparable objects Compare....The following dialog appears.
Fig. 3-1 Select comparison partner dialog
The object you selected previously in the project navigator is highlighted ascomparison partner A. If you had not selected an object, the first object inthe list is highlighted.
3. Select comparison partner B. The following options are available:
Object from the open project:You can select from the objects in the open project.
Object from a saved project:First open a saved project using the button:
You can select from the objects in this project.
Note
A comparison with online objects is only possible if the objects are online. Noimplicit connection is established when the comparison is started!
8/6/2019 Project Comparison
19/46
Functions
3-19 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Object from the target system (online): (only possible in ONLINE mode andif the project is present in the target system)The object from the SCOUT or Starter is compared with the object on thetarget system.
4. The Start comparison button is activated once you have selected the objectwith which the comparison can be run. Open the object comparison using thebutton Start comparison.
Different versions detected (offline comparison with saved project)
If the comparison partner is in a different project, that was created with an olderversion of SIMOTION SCOUT, a comparison cannot be undertaken. The follow-ing note appears:
Fig. 3-2 Different comparison partner versions
In this case, first convert to the current version of SIMOTION SCOUT. Thenrestart the comparison.
Note
When comparing with a different project, this must at least be in SIMOTIONSCOUT/Starter version 4.1. Otherwise you will first have to convert the project.
8/6/2019 Project Comparison
20/46
Functions
3-20 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
3.3 Assignment of objects in object comparison
The objects of the two comparison partners must be assigned to one another. Thecomparison types and comparison categories are needed for this:
Every object and every folder has just one comparison type and can be assignedto one comparison category. For example, two SIMOTION devices (e.g. C230and D435) belong to the same category, but have different comparison types. Acomparison category may therefore contain objects with different comparisontypes.
A distinction is made between the following cases when assigning objects:
Manual assignment when selecting the comparison objects
Automatic assignment of the subordinate objects
3.3.1 Manual selection of comparison objects
The comparison objects you have selected represent the roots in the comparisontree. The objects must at least belong to the same comparison category while thecomparison type may differ.
If the names are different, e.g. CPU_1 is being compared with CPU_2, bothnames are shown in the root node of the comparison tree.
If the object types are different, a difference is marked and attempts are made toassign the lower level objects.
3.3.2 Automatic assignment of the subordinate comparison objects
During automatic assignment, all objects below the root are assigned taking theirposition in the tree into account. For example, axis 1 and axis 2 are assigned inthe comparison. During automatic assignment of the subordinate objectsattempts are made to assign the probes under axis 1 to the probes under axis 2provided that they are of the same comparison type.
During a specific object to object assignment, a distinction is made betweenTOs/DOs and other objects:
Assignment of TOs/DOs using object addresses
TOs/DOs are assigned using their object address. In this case, the objectaddress appears after the name: (). Since the name ofthe object may differ in this case, both names are shown in the event of deviation.
Note
When switching into ONLINE mode, TOs/DOs for the consistency display in theproject navigator are also assigned using the object address.
8/6/2019 Project Comparison
21/46
Functions
3-21 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
When assigning using the object address, cases may arise where e.g. a probeunder axis A1 has the same object address as the probe under axis A2 in thecomparison project:
Fig. 3-3 Example of assignment when the object addresses differ
Since the object addresses are issued automatically, this may occur if the objectsare created e.g. in a different order or using script.
But this assignment is not desirable as it would result in incorrect object assign-ment. The object address is therefore only taken into account within the samehierarchy level during assignment but not over hierarchy levels.
If necessary, you can change the object addresses of TOs yourself. This allows
you to enforce correct assignment of the object address for TOs later on.
Assignment of other objects using names
Other objects, i.e. all objects outside the TOs/DOs, are assigned using theirnames.
Note
We would recommend always explicitly issuing the object address for TOs (SeeChanging the object address on page 3-22). You cannot change the address ofDOs!
Note
If objects are not automatically assigned despite having the same name and aretherefore positioned one above the other in the comparison tree, the comparisontype is different.
8/6/2019 Project Comparison
22/46
Functions
3-22 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
3.3.3 Changing the object address
Procedure
To change the object address:
1. Select the appropriate TO in the project navigator.
2. In the context menu, open Properties....
3. Click on the Object address tab.
4. Change the object address in the New address field.
5. Click on the Assign button and confirm with OK.
8/6/2019 Project Comparison
23/46
Functions
3-23 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
3.4 Detailed comparison
3.4.1 Starting the detailed comparison
Requirement
The detailed comparison for ST programs, TOs and DOs can be started from thecomparison tree by clicking on the
button.
You can only start the detailed comparison if
you have found differences or
if the additional data required is available for the online comparison.
In the detailed comparison, the corresponding content are shown next to oneanother, the differences marked and the transfer of changes from the comparisonobject into the reference object made possible if required.
Procedure
1. First run an object comparison on the device you want. (See Starting theobject comparison on page 3-17)
2. The Start detailed comparison button is shown in the Status column forobjects for which a detailed comparison can be run.
Fig. 3-4 Example of detailed comparison for two ST programs
3. Click on the Start detailed comparison button to compare the ST programsor DOs/TOs. The corresponding editors are opened next to one another in theview and the differences marked.
3.4.2 ST detailed comparison
The ST detailed comparison allows you to run a textual comparison on STsources. The compared sources are shown next to one another and the differ-ences marked in color. Missing lines (marked in gray) are added so that identicallines can be shown synchronized.
You can transfer the differences line by line. You have to open the ST editor forediting. You cannot edit in the detailed comparison.
8/6/2019 Project Comparison
24/46
Functions
3-24 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Fig. 3-5 Example of ST detailed comparison
Note
Not the information provided in the status bar at the end of the view.
Note
In isolated cases, a difference is detected as a result of a control character, e.g.a line break, which is not however of any relevance to the source text.
8/6/2019 Project Comparison
25/46
Functions
3-25 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Function buttons of the ST detailed comparison
Menu ST detailed comparison
Procedure
1. Perform an object comparison test.
2. Start the ST detail comparison. The sources are compared in the ST detailcomparison and the differences marked in color.
3. If necessary, transfer the differences into the project.
4. Close the detail comparison and confirm with OK.
Table 3-1 Function buttons ST detailed comparison
Description
Jumps to next difference
Jumps to last difference
Jump to marked line(s) in the source (from comparison partner B to A)
Complete transfer of differences in the source (from comparison partner B to A)
Table 3-2 Menu ST detailed comparison
Menu item Description
Display line numbers Displays the line numbers of comparison partners A
and B
Ignore indents Indents in the source are ignored; you need to
define this before first transferring changes as youcannot change the setting for the current compari-
son afterwards.
Transfer changes into project Transfers the changes into the project and saves
the changes
Close and open editor Opens comparison partner A in the ST editor. Thedetail comparison closes.
8/6/2019 Project Comparison
26/46
8/6/2019 Project Comparison
27/46
Functions
3-27 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
TO detailed comparison
Example of a TO detailed comparison.
Fig. 3-6 Example of a TO detailed comparison.
8/6/2019 Project Comparison
28/46
Functions
3-28 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
DO detailed comparison
Example of a DO detailed comparison
Fig. 3-7 Example of a DO detailed comparison
8/6/2019 Project Comparison
29/46
Functions
3-29 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
3.5 Data transfer
You can use the "Data transfer" function in the object comparison to transfer thedata of the comparison object (B) into the open project (A). You can transfer indi-
vidual data working from the detail comparison. You can run a complete onlinecalibration from B to A using the function Download into PG/PC or from A to Busing Download to target device.
Rules for data transfers in the object comparison
Rules applicable to the transfer:
When you transfer an object, the content of the object is transferred in full fromthe comparison object (e.g. compiler settings too) and overwrites the data inthe reference object. In other words, changes that you undertook in the refer-ence project may be lost!
If the comparison partner is in the target system, the corresponding informa-tion must be available online. If this is not the case (e.g. if there is no intercon-nection information for DCC plans, or if the sources of ST programs have notbeen downloaded to the target device), the transfer is not possible.
DOs cannot be transferred.
A TO/program can be transferred into an existing TO/program. TOs/programs
cannot on the other hand be created, e.g. in cases where there is not a TO inA, but there is one in B.
TOs/DOs cannot be deleted by transferring them, e.g. if there is a TO/DO inA, but not in B.
Know how-protected objects are transferred. Objects open in an editor areclosed.
When entire objects are transferred, the object address is also transferred(see duplicate assignment of an object address).
If an object cannot be transferred because it is not present in the open project,you can create an "empty" object with the same object address (for TOs) orwith the same name (for programs) and then repeat the data transfer. TOs ora program entry in the execution system then still has to be linked by hand.
If you do not want to transfer entire objects but just individual pieces of datafrom an object, you can only do this in the detail comparison. Here you can forexample transfer one particular change to an ST program (see detailed com-parison).
Note
In the event of errors when downloading to the PG, note the information on thedetail view in the object comparison tab.
8/6/2019 Project Comparison
30/46
Functions
3-30 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Procedure for data transfer
To transfer data, proceed as follows:
1. Place a check mark in the check box (see diagram below) for the object youwant to transfer.
Fig. 3-8 Selection and transfer of objects
2. Start the transfer by clicking on the button Data transfer and confirm the fol-lowing dialog with OK.
Fig. 3-9 Data transfer dialog
Once transferred, the check box is replaced by a check mark. The result of thecomparison in the object comparison is then no longer up-to-date. This is indi-cated in the status bar at the end of the view.
Fig. 3-10 View following transfer
8/6/2019 Project Comparison
31/46
Functions
3-31 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Duplicate assignment of an object address
When transferring entire objects, the object address is also transferred. Since theobject address in the address space of a SIMOTION device must be unique,address conflicts may result. A transfer which would result in a duplicate assign-
ment is not carried out. The object affected by the address conflict is entered inthe log in the detailed view.
Change the object address as required.
(See Changing the object address on page 3-22)
8/6/2019 Project Comparison
32/46
8/6/2019 Project Comparison
33/46
4-33 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Overview of comparison attributes 4Below you will find an overview of the comparison attributes for SIMOTION,SINAMICS and MICROMASTER objects.
The comparison attributes are made up of several comparison features. Thereare various reasons for a difference in comparison attributes. A difference in thecompilation result may e.g. result from program changes (source code) and/or achange to the compiler settings. The tables below describe the comparisonattributes for the individual object types. They should help you to be able to
quickly establish the causes in the event of a difference if a detailed comparisonis not available.
We recommend the following procedure for efficiently finding the reason for a dif-ference to a comparison attribute:
If necessary compile the project if the compilation result is no longer up-to-date
Start detailed comparison, if available
Search for description of comparison attribute in the object table
Check the comparison features
To be able to check the comparison features (e.g. the compiler settings) duringan online comparison, create a new project with a SIMOTION device and down-
load the target devices into the PG for this new SIMOTION device. The additionaldata must have already been downloaded.
When comparing with a different project, we would recommend opening this in asecond SCOUT/Starter.
8/6/2019 Project Comparison
34/46
Overview of comparison attributes
4-34 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
4.1 SIMOTION objects
SIMOTION device
Table 4-1 Comparison attributes of a SIMOTION device
Comparison attributes of a
SIMOTION device
Comparison features which are included in the com-
parison attribute
Execution system The configuration of the execution system:
The assignment of programs to the tasks
Configuration of tasks in the "Task configuration" tab
System cycle settings using the function "Set system
cycles..." (Servo, Ipo, Ipo_2, TControl)
Execution system - compila-
tion result
The part which results from the project's compilation pro-
cess.
The compilation result includes:
The configuration of the execution system (see above)
The technology packages used
I/O variables Configuration of I/O variables
Note: Structural changes to the I/O variables are also
included in the "HMI relevant data" comparison
attribute.
Global device variables Configuration global device variables
Note: Structural changes to the global device variables
are also included in the "HMI relevant data" comparison
attribute.
HW config (time stamp com-
parison)
Comparison of the hardware configuration is based solely
on a time stamp comparison. The time stamp of the last
change is used. A comparison undertaken on this basis
only allows a same statement to be made if the time
stamp is the same. If the time stamp is different, the hard-
ware configuration may be the same or different. This is
the case e.g. if the last change has been reversed.
STEP7 SIMATIC manager offers a block comparison for
such cases.
Offline comparison
The comparison is undertaken as described above.
Online comparison (devices which have been down-loaded with a SCOUT/STARTER version
8/6/2019 Project Comparison
35/46
Overview of comparison attributes
4-35 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
HW config (system integra-tion) The data from the hardware configuration which isincluded in the SIMOTION configuration:
I/O addressing (in HW config)
DP cycle (bus cycle)
Equidistant bus cycle
Devices which have been downloaded with a
SCOUT/STARTER version
8/6/2019 Project Comparison
36/46
8/6/2019 Project Comparison
37/46
8/6/2019 Project Comparison
38/46
Overview of comparison attributes
4-38 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
DCC plan
Table 4-4 Comparison attributes of a DCC plan
Comparison attributes of a
DCC plan
Comparison features which are included in the com-
parison attribute
Source code
(time stamp comparison)
Offline only
Changes in the DCC editor based on a time stamp (last
change).
If values are changed in online mode, the changes and
therefore the time stamp are detected offline.
Note: The comparison is based on a time stamp com-
parison only. The time stamp of the last change is used.
A comparison undertaken on this basis only allows a
same statement to be made if the time stamp is the
same. If the time stamp is different, the source code
may be the same or different (e.g. if the last change
was reversed). A statement on this cannot be made inthe object comparison. This is shown by a ?.
Blocks Block instances and their properties, like
Type
Name
Address
Constant values (initial values) of inputs and outputs
Assignment to run-time group
Predecessor in run-time group
Interconnections The following interconnections are included in the com-
parison:
Plan interconnections
Interconnection of all the plan's inputs
Interconnections with run-time groups
Interconnections with @ parameters
Interconnections with non-DCC-objects within SIMO-
TION (TOs/sources, global device variables, I/Os)
Run-time groups Plan run-time groups and their properties
Name
Task assignment
Predecessor run-time group
Initial state of run-time group (active / inactive)
8/6/2019 Project Comparison
39/46
Overview of comparison attributes
4-39 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
@ parameters and externalreferences SIMOTION: Published parameters
Compiler settings
External references
Interfaces of referenced sources (pro-
grams(ST,MCC,KOP-FUP),
Reference parameters of other DCC plans,
Interfaces of DCC libraries used,
Global device variables used,
I/O variables used,
TO system variables used
SINAMICS:
Parameter values of the @parameters
p parameter: Values of adjustable parameters and
BICO interconnections on BICO dies
HMI relevant data Records the structural set-up (data type of variables,
number of variables) of the data which an HMI system
can access. If the set-up changes, the HMI configuration
must be updated. Data included:
SIMOTION:
Online/offline comparison:
The @ parameters of the plan (published parameters)
The object address (see plan properties)
Offline/online comparison:
See @ parameters and external references
SINAMICS:
Not applicable
Table 4-4 Comparison attributes of a DCC plan
Comparison attributes of a
DCC plan
Comparison features which are included in the com-
parison attribute
8/6/2019 Project Comparison
40/46
8/6/2019 Project Comparison
41/46
Overview of comparison attributes
4-41 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
DCC plan in a library
Table 4-7 Comparison attributes of a source in a DCC library
Comparison attributes of a
DCC library
Comparison features which are included in the com-
parison attribute
Source code (time stamp
comparison)
Offline only
Changes in the DCC editor based on a time stamp (last
change).
If values are changed in online mode, the changes and
therefore the time stamp are detected offline.
Note: The comparison is based on a time stamp com-
parison only. The time stamp of the last change is used.
A comparison undertaken on this basis only allows a
same statement to be made if the time stamp is the
same. If the time stamp is different, the source code
may be the same or different (e.g. if the last change
was reversed). A statement on this cannot be made inthe object comparison. This is shown by a ?.
Blocks Block instances and their properties, like
Type
Name
Address
Constant values (initial values) of inputs and outputs
Assignment to run-time group
Predecessor in run-time group
Interconnections The following interconnections are included in the com-
parison:
Plan interconnections
Interconnection of all the plan's inputs
Interconnections with run-time groups
Interconnections with @ parameters
Interconnections with non-DCC-objects within SIMO-
TION (TOs/sources, global device variables, I/Os)
Run-time groups Plan run-time groups and their properties
Name
Task assignment
Predecessor run-time group
Initial state of run-time group (active / inactive)
8/6/2019 Project Comparison
42/46
Overview of comparison attributes
4-42 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
4.2 SINAMICS objects
Drive unit
DO
DCC plan
Description of comparison attributes: See DCC plan on page 4-38
Table 4-8 Comparison attributes of a drive unit
Comparison attributes of a
drive unit
Comparison features which are included in the com-
parison attribute
Reference topology The reference topology
For this comparison attribute, the serial number is not
taken into account in the comparison.
Topology
(with serial number)
Topology
For this comparison attribute, the serial number is taken
into account in the comparison.
Table 4-9 Comparison attributes of a DO
Comparison attributes of a
drive object (DO)
Comparison features which are included in the com-
parison attribute
Function modules Function modules (see parameter 108 in the DO list of
experts)
Structure parameters Parameter which determine structures, e.g. DDS
Download parameters Download parameters (see DO list of experts)
Units Units
This comparison feature does not determine structure.
8/6/2019 Project Comparison
43/46
Overview of comparison attributes
4-43 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
4.3 MICROMASTER and SINAMICS G120 objects
Table 4-10 Comparison attributes
Comparison attribute Comparison features which are included in the com-parison attribute
Device version Power unit/infeed
(configuration vector specifies the device version of a
device type)
(Only available with G120, not MM4 or Combimaster)
Download parameters Download parameters (see list of experts)
8/6/2019 Project Comparison
44/46
8/6/2019 Project Comparison
45/46
Index-45 Siemens AG 2008 All Rights ReservedSIMOTION Project comparison, Edition 08/2008
Index
CChanging object address
Object comparison, 3-22Comparison attributes
Data of relevance to the process, 2-15DCC plan, 4-38DCC plan in a library, 4-41DCC plan SINAMICS, 4-42
Detailed comparison, 2-15DO SINAMICS, 4-42Library, 4-40MICROMASTER, 4-43Object comparison, 4-33SIMOTION device, 4-34SINAMICS drive unit, 4-42SINAMICS G120, 4-43Source in a library, 4-40Sources, 4-36Technology objects, 4-36
Comparison status
not up-to-date, 2-14Comparison tree
Update, 2-14
DData transfer
Object comparison, 3-29Detailed comparison, 3-23Different versions object comparison, 3-19DO detailed comparison, 3-28
IInconsistencies in the project comparison
Project navigator, 1-9
OObject address object comparison
Technology objects, drive objects, 2-16Object comparison
Additional data, 3-17Assignment of objects, 3-20Automatic assignment of objects, 3-20Changing object address, 3-22
Comparison tree, 2-14Elements, 2-11Manual assignment of objects, 3-20Starting, 3-17
PProject comparison
Overview, 1-9
RResult of comparison
Object comparison icons, 2-13
Same/different, 2-12Status in object comparison, 2-12
SSIMOTION objects, 4-34SINAMICS objects
Comparison attributes, 4-42ST detailed comparison, 3-23Starting detailed comparison, 3-23Structure, 2-11
TTO detailed comparison, 3-27
TO/DO detail comparison, 3-26
8/6/2019 Project Comparison
46/46