VICTRIX PRORANGECommercial
condensing boilers
PR
OF
ES
SIO
NA
L
Certificate No: GSCS202042
Immergas.Our long story teaches us alwaysto look to the future.
The 5th of February 1964 saw the birth of Immergas out of an inescapable desire to come up with ideas and reliable products in the Italian style. Products designed to last that would improve people’s lives. Today, for the thousands of engineers and employees who work and cooperate with us, nothing has changed. We are present in over 40 countries with 9 branches in Europe and one in China, we have partnerships with the most important distribution companies across the globe, yet we keep on investing in facilities, plants, and technologies with the selfsame spirit.
On account of the same business idea we insist on developing our designs and paying more attention to the environment and consumption through new technologies. This same enthusiasm means that we continue to reaffirm day after day the importance of collaborating with those who sell, install and offer assistance to look after Immergas products and above all our end customers.Nowadays, just like 50 years ago, our profoundest thoughts go out to them with the intention of contributing to a better future made up of comfort, safety, reliability, and environmental friendliness.
1964 - 2016
VICTRIX PRO 80VICTRIX PRO 55 VICTRIX 100
VICTRIX PRO 120
Wall-hung modular condensing boilers for heating only
HIGH HEATING OUTPUT, WIDE MODULATING RATIO AND HIGH EFFICIENCYModularity and high output make the new VICTRIX PRO range ideal for the central heating systems of residential and commercial buildings, but the new design and compact dimensions make them suitable for private homes as well.All models can be installed either indoors or outdoors, on a wall or on a new free standing support frame, and offer excellent solutions to designers who have to install central heating systems in buildings where little space is available. The modularity of installation makes it possible to place up to 5 boilers side by side, and the exceptional power modulating ratio is up to 1:10. With these features, VICTRIX PRO boilers are perfect for energy upgrading of any existing or new buildings thanks also to the possibility of connecting them to renewable energy sources such as solar heating.The range includes:
VICTRIX PRO range
VICTRIX PRO RANGE
A WIDE RANGEFrom 55 kW to 120 kW output
REDUCED CONSUMPTION Very high modulation rangeup to 1:10
CASCADE INSTALLATIONOF UP TO 5 BOILERS SIDE BY SIDE OR 10 BOILERS BACK TO BACK
INDOOR AND OUTDOORINSTALLATION
NEW REMOTE CONTROL
VICTRIX PRO range
COMFORT & TECHNOLOGY
BEYOND TECHNOLOGY, SUPPORT FOR PROFESSIONALSTo provide professionals with all necessary information and get the most out of the new commercial light boiler solutions, Hunt Heating has a technical team always available to provide guidance or regulations for the design and layout of hydraulic and electrical plant schemes.
5
NEW CONTROL PANELThe new vertically sliding door protects the display and the board. The boiler controls are user friendly thanks to simple buttons and a backlit display.
HIGH SEASONAL EFFICIENCYThe modulation range of 1:10 makes it possible to optimize boiler function even with reduced heating requirements (for example, during mid-seasons or in case of multi zone systems).
NEW REMOTE CONTROLFor systems in which remote control is a desirable feature, an optional kit is available to communicate exclusively with the cascade and zone regulator (see page 11) so as to control the central heating system.
COMPLETE RANGE OF OPTIONALSWith VICTRIX PRO the installer and designer can avail themselves of all the optionals to complete the central heating system from the hydraulic components, the thermoregulation devices, the flue systems to condensate neutralisers.
PRODUCTION OF DOMESTIC HOT WATER IS ALSO INTEGRATED WITH SOLAR SYSTEMSFor both individual boilers and battery installations, VICTRIX PRO can be combined with Immergas solar solutions for the production of domestic hot water, in particular to the storage tanks units with capacities of 200, 300, 500, 1000, 1500 and 2000 liters.
ADVANTAGES
.01
.01
6
ADVANTAGES
MODULAR INSTALLATIONConsidering that up to 5 boilers (with the relative optionals) can be installed hydraulically in cascade, it has never been so easy to reach powers as high as 600 kW.
INSTALLATION ON SUPPORTING FRAMEVICTRIX PRO can be installed on a modular type supporting frame either individually or in batteries of up to 5 boilers in line or in a back-to-back arrangement in case of space constraints. The frames are equipped with a supporting collar for the hydraulic manifolds and can be fastened to the wall or floor with special anchor bolts.
IDEAL ALSO FOR OUTDOOR INSTALLATIONSThanks to the high degree of electrical protection (IPX5D) and cataphoresis treatment on the frame, VICTRIX PRO can also be installed outdoors.
.02
.02
7
TECHNICAL CHARACTERISTICS
.04
COMBUSTION SYSTEM AND TOTAL PREMIXINGResearch and development in the sector of combustion system has enabled us to achieve a modulation field raised from 10 to 100% of the thermal power on the entire range.In addition, the boilers can function with either national gas or LPG.
INTEGRATED TRAP FOR CONDENSATION DISPOSALA special trap built into the boiler collects the condensation and ensures its regular drainage; the trap is connected to a polypropylene hose which will not be damaged by the action of the condensate.On the outside of the boiler, the acid condensation should be discharged according to local regulations.
MODULE FOR CONDENSATION IN STAINLESS STEELThe range is equipped with condensation modules in which the hydraulic circuit is made of stainless steel (for the VICTRIX PRO 55 version, the outer shell is made from a composite material).It is essential that the central heating system is thoroughly cleaned and flushed when fitting a VICTRIX PRO; it is important to use the cleaning agent and inhibitor in order to preserve the heating system (pipes, heat exchanger, etc.).
LOW EMISSIONS OF NOxAND CO POLLUTANTSThe range has obtained a class 5 rating in terms of pollutant emissions, making it an excellent choice for installation in buildings that require high energy performance and low environmental impact.
OPTIMUM CONTROL OF ADJUSTMENTThe inclusion of two NTC probes (in the delivery and return of the system) guarantees optimum control of the operating temperature.
.03 .04
.03
8
EASY CONTROL OF BOILERS IN CASCADE INSTALLATIONSThe cascade and zone regulator makes it possible to manage, control and program the sequence of operations of the boilers connected, deciding which boiler to start, the output required and the operating sequence depending on the request of the heating system.
CONTROL OF SOLAR SYSTEMS FOR THE PRODUCTION OF DOMESTIC HOT WATERThe cascade regulator serves for easy management of a thermal solar system for the production of D.H.W., adding special control probes (see page 17).
Electrical connectionto the main boiler
Temperature setting
No. of boilersmanageable
Manageable zones
Connectionin series
Connection toa solar system
2 BUS cables: max distance 50 meters
Room heating:Comfort, less antifreeze
D.H.W. setting
8 3 (2 of which mixed)+ 1 boiler unit
Up to 5 cascade regulators of which only the main regulator (master)will be connectedon the boiler
Possibility of setting solar circuit parameters without the need of extra control units
MAIN FEATURES
.05
.05
TECHNICAL CHARACTERISTICS
9
TECHNICAL DATA
Technical data Unit ofmeasurement
VICTRIXPRO 55
VICTRIXPRO 80
VICTRIXPRO 100
VICTRIXPRO 120
Code N.G.L.P.G.
VICTRIX PRO 55 VICTRIX PRO 80 VICTRIX PRO 100 VICTRIX PRO 120
CE certificate 0051CO4405 0051CO4405 0051CO4405 0051CO4405
Nominal gas consumption MJ/h 204.,9 300,7 368,9 455,9
Minimum gas consumption MJ/h 21,9 30,3 39,0 45,6
Maximum nominal heat output (80/60 °C) kW 49,9 73,0 90,0 111,0
Minimum nominal heat output (80/60 °C) kW 5,0 7,2 9,4 11,0
Maximum nominal heat output (50/30 °C) kW 54.8 80.3 98.8 121.7
Minimum nominal heat output (50/30 °C) kW 5.5 8.1 10.5 12.2
Useful nominal efficiency (80/60 °C) % 97.3 97.0 97.5 97.3
Useful partial efficiency (80/60 °C) % 91.2 94.8 96.2 96.4
Useful nominal effiency (50/30 °C) % 106.8 106.6 107.0 106.7
Useful partial efficiency (50/30 °C) % 99.7 106.9 107.4 107.2
Useful nominal efficiency (40/30 °C) % 107.4 107.3 107.4 107.2
Useful partial efficiency (40/30 °C) % 103.5 107.2 107.6 107.5
Stack losses with burner on 100% Pn (80/60 °C) % 1,8 2,2 1,9 2,0
Stack losses with burner OFF % 0,02 0,01 0,01 0,01
Casing losses with burner ON 100% Pn (80/60 °C) % 0,8 0,7 0,6 0,7
Casing losses with burner OFF % 0,27 0,3 0,37 0,25
NOx class 5 5 5 5
Weighted NOx mg/kWh 39,0 25,0 20,0 33,0
Weighted CO mg/kWh 15,0 16,0 12,0 18,0
Gas flow rate to burner at max, and min. heat output with methane (G20) m3/h 4,89 - 0,52 7,18 - 0,72 8,80 - 0,93 10,88 - 1,09
Maximum fan available head (max/min) Pa 110/1 230/6 208/4 145/5
Flue exhaust mass flow rate at nominal heat output (N) Kg/h 73 103 131 160
CO2 at nominal/minimum heat output (N) 9,40 / 9,10 9,85 / 8,85 9,45 / 8,90 9,60 / 9,00
CO/CO2 at nominal heat output (N) 0,00134 0,00195 0,00153 0,00162
Maximum fume temperature °C 52 62 54 56
Maximum operating temperature °C 90 90 90 90
Heating system adjustable temperature °C 20- 85 20 - 85 20 - 85 20 - 85
Maximum operating pressure of heating circuit bar 4,4 4,4 4,4 4,4
Electric power V/Hz 230 - 50 230 - 50 230 - 50 230 - 50
Max power supply W 155 195 285 345
Electrical insulation rating IP X5D X5D X5D X5D
Empty weight kg 51,4 81,0 95,9 102,5
Boiler water capacity litres 2,8 4,0 10,1 11,7
10
CASCADE TECHNICAL DATA
Technical data Unit ofmeasurement
2 X VICTRIXPRO 55
2 X VICTRIXPRO 80
2 X VICTRIXPRO 100
2 X VICTRIXPRO 120
Nominal gas consumption MJ/h 409.8 601.4 737.8 911.8
Minimum gas consumption MJ/h 21.9 30.3 39 45.9
Maximum nominal heat output (80/60 °C) kW 99.8 146 180 222
Minimum nominal heat output (80/60 °C) kW 5 7.2 9.4 11
Heating system adjustable temperature °C 20 - 85 20 - 85 20 - 85 20 - 85
Maximum operating pressure of heating circuit bar 4.4 4.4 4.4 4.4
Electric power V/Hz 230 - 50 230 - 50 230 - 50 230 - 50
Electrical insulation rating IP X5D X5D X5D X5D
Empty weight (boilers only) kg 102.8 162 191.8 205
Boiler water capacity (boilers only) litres 5.6 8 20.2 23.4
Technical data Unit ofmeasurement
3 X VICTRIXPRO 55
3 X VICTRIXPRO 80
3 X VICTRIXPRO 100
3 X VICTRIXPRO 120
Nominal gas consumption MJ/h 614.7 902.1 1106.7 1367.7
Minimum gas consumption MJ/h 21.9 30.3 39 45.6
Maximum nominal heat output (80/60 °C) kW 149.7 219 270 333
Minimum nominal heat output (80/60 °C) kW 5 7.2 9.4 11
Heating system adjustable temperature °C 20 - 85 20 - 85 20 - 85 20 - 85
Maximum operating pressure of heating circuit bar 4.4 4.4 4.4 4.4
Electric power V/Hz 230 - 50 230 - 50 230 - 50 230 - 50
Electrical insulation rating IP X5D X5D X5D X5D
Empty weight (boilers only) kg 154.2 243 287.7 307.5
Boiler water capacity (boilers only) litres 8.4 12 30.3 35.1
11
CASCADE TECHNICAL DATA
Technical data Unit ofmeasurement
4 X VICTRIXPRO 55
4 X VICTRIXPRO 80
4 X VICTRIXPRO 100
4 X VICTRIXPRO 120
Nominal gas consumption MJ/h 819.6 1202.8 1475.6 1823.6
Minimum gas consumption MJ/h 21.9 30.3 39 45.6
Maximum nominal heat output (80/60 °C) kW 199.6 292 360 444
Minimum nominal heat output (80/60 °C) kW 5 7.2 9.4 11
Heating system adjustable temperature °C 20 - 85 20 - 85 20 - 85 20 - 85
Maximum operating pressure of heating circuit bar 4.4 4.4 4.4 4.4
Electric power V/Hz 230 - 50 230 - 50 230 - 50 230 - 50
Electrical insulation rating IP X5D X5D X5D X5D
Empty weight (boilers only) kg 205.6 324 383.6 410
Boiler water capacity (boilers only) litres 11.2 16 40.4 46.8
Technical data Unit ofmeasurement
5 X VICTRIXPRO 55
5 X VICTRIXPRO 80
5 X VICTRIXPRO 100
5 X VICTRIXPRO 120
Nominal gas consumption MJ/h 1024.5 1503.5 1844.5 2279.5
Minimum gas consumption MJ/h 21.9 30.3 39 45.6
Maximum nominal heat output (80/60 °C) kW 249.5 365 450 555
Minimum nominal heat output (80/60 °C) kW 5 7.2 9.4 11
Heating system adjustable temperature °C 20 - 85 20 - 85 20 - 85 20 - 85
Maximum operating pressure of heating circuit bar 4.4 4.4 4.4 4.4
Electric power V/Hz 230 - 50 230 - 50 230 - 50 230 - 50
Electrical insulation rating IP X5D X5D X5D X5D
Empty weight (boilers only) kg 257 405 479.5 512.5
Boiler water capacity (boilers only) litres 14 20 50.5 58.5
12
TECHNICAL DATA
KeyElectrical connectionGas supplyCondensate drain (minimum internal diameter Ø 13 mm)System deliverySystem return
VGSCMR
VICTRIX PRO 55 FRONT VIEW
Hydraulic connections
Gas Heating Condensate drain
G R M SC
3/4” 1 ½” 1 ½” 25 mm
Dimensions and connections
VICTRIX PRO 35 - 55 2 ErP
33
VICTRIX PRO 35 - 55 2 ErP boilers are supplied with a sin-gle-phase pump (230 V - 50 Hz) with variable speed control and low power consumption.When the boiler operates in heating mode, the pump speed is defined according to the “P27” and “P28” parameter settings of the boiler.
In domestic hot water mode, the circulator pump always runs at full speed.If zone valves are installed on the central heating system, or if there is poor water circulation, it is advisable to use the by-pass kit (optional).
GRUNDFOS UPM2 15-70 AOS PWM
23 GRAPH OF VICTRIX PRO 35 - 55 2 ErP PUMP HEAD FLOW RATE
A = Head available to the system. B = Power absorbed by the circulator pump (dotted area)
Hea
d (k
Pa)
Flow rate l/h
Pow
er a
bsor
bed
by p
ump
(W)
A
B
23.1 VICTRIX PRO 35 - 55 2 ErP PUMP
G
450
457225
Ø 80
225
14076
5 843 94
6
994
50
221 221
442
92 30
300 7171SC
V
M R
200
220
281
45316
0
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
190
136
160
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
190
136
GRUNDFOS UPM2 15-70 AOS PWM
13
TECHNICAL DATA
VICTRIX PRO 80
Dimensions and connections
KeyElectrical connectionGas supplyCondensate drain (minimum internal diameter Ø 13 mm)System deliverySystem return
VGSCMR
960
600
608304 304
Ø 80
G SCM
R
300 300
V
390105 105
1317560
1038 11
40
1219
502140
134220
291265
497
190
136
160
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
190
136
160
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
Hydraulic connections
Gas Heating Condensate drain
G R M SC
3/4” 1 ½” 1 ½” 25 mm
VICTRIX PRO 80 - 100 - 120 2 ErP
34
VICTRIX PRO 80 2 ErP boilers are supplied with a sin-gle-phase pump (230 V - 50 Hz) with variable speed control and low power consumption. When the boiler is in central heating mode, the pump's speed is
the boiler and varies to keep ∆T constant between the system's
In domestic hot water mode, the circulator pump always runs at full speed.
A = Head available to the system. B = Power absorbed by the circulator pump (dotted area)
GRUNDFOS UPM GEO 25-85 PWM
Hea
d (k
Pa)
Flow rate l/h
Pow
er a
bsor
bed
by p
ump
(W)
A
B
24 GRAPH OF VICTRIX PRO 80 2 ErP PUMP HEAD FLOW RATE
24.1 VICTRIX PRO 80 2 ErP PUMP
GRUNDFOS UPM 25-85 PWM
14
TECHNICAL DATA
VICTRIX PRO 100/120Key
Electrical connectionGas supplyCondensate drain (minimum internal diameter Ø 13 mm)System deliverySystem return
VGSCMR
Dimensions and connections
960
600
608304 304
Ø 80
G SCM
R
300 300
V
390105 105
1317560
1038 11
40
1219
632140
134220
291410
627
190
136
160
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
190
136
160
110
Horizontal concentrickit Ø 80/125
Horizontal outletkit Ø 80
Hydraulic connections
Gas Heating Condensate drain
G R M SC
1” 1 ½” 1 ½” 25 mm
VICTRIX PRO 80 - 100 - 120 2 ErP
35
VICTRIX PRO 100 2 ErP boilers are supplied with a sin-gle-phase pump (230 V - 50 Hz) with variable speed control and low power consumption. When the boiler is in central heating mode, the pump's speed is defined according to the “P27” and “P28” parameter settings of
the boiler and varies to keep ∆T constant between the system's flow and return at a value below 18 °C. In domestic hot water mode, the circulator pump always runs at full speed.
GRUNDFOS UPMXL GEO 25-125 PWM
25 GRAPH OF VICTRIX PRO 100 2 ErP PUMP HEAD FLOW RATE
25.1 VICTRIX PRO 100 2 ErP PUMP
A = Head available to the system. B = Power absorbed by the circulator pump (dotted area)
Hea
d (k
Pa)
Flow rate l/h
Pow
er a
bsor
bed
by p
ump
(W)
A
B
GRUNDFOS UPMXL GEO 25-125 PWMVICTRIX PRO 100
GRUNDFOS UPMXL GEO 25-125 PWMVICTRIX PRO 120
VICTRIX PRO 80 - 100 - 120 2 ErP
36
VICTRIX PRO 120 2 ErP boilers are supplied with a sin-gle-phase pump (230 V - 50 Hz) with variable speed control and low power consumption. When the boiler is in central heating mode, the pump's speed is defined according to the “P27” and “P28” parameter settings of
the boiler and varies to keep ∆T constant between the system's flow and return at a value below 18 °C. In domestic hot water mode, the circulator pump always runs at full speed.
GRUNDFOS UPMXL GEO 25-125 PWM
26 GRAPH OF VICTRIX PRO 120 2 ErP PUMP HEAD FLOW RATE
26.1 VICTRIX PRO 120 2 ErP PUMP
A = Head available to the system. B = Power absorbed by the circulator pump (dotted area)
Hea
d (k
Pa)
Flow rate l/h
Pow
er a
bsor
bed
by p
ump
(W)
A
B
15
ACCESSORIES
Type Description Code
Remote control for single VICTRIX PRO
This is a modulating control unit that serves to optimize climatic management of the temperature in rooms.It can only be used on systems with a single temperature control
3.020358
CRONO 7(weekly digital chronothermostat)
Chronothermostat ON-OFF for control of generator function according to time and temperature settings (comfort and economy)
3.021622
External probe
Connected to the boiler board, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature operation
3.015266
System delivery probe kit for the boilerConnected to the boiler board, it measures the delivery temperature after the hydraulic manifold
3.024245
Storage tank sensor probe For use with easy cascade 1.015677
Anti freeze protection kit -15 °C Usable in outdoor installations for minimum temperature as low as -15 °C 3.024513
SYSTEMS OF CONTROL AND HEAT ADJUSTMENT FOR INDIVIDUAL OR EASY CASCADE INSTALLATIONBased on the type of installation and comfort required, the following accessories can be used.
16
ACCESSORIES
Type Description Code
Cascade and zone regulator kit
ON-OFF adjustment, modulation andmalfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit)
3.015244
Wall box kit for cascade and zone regulator
If the cascade and zone regolator is not install inside an electrical box 3.015265
Zone manager kit
Electrically connected to cascade andzone regulator, serves to manage climaticconditions of one of system zone, and allow remote control of the cascade and zone regulator
3.015264
Flow probe
Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones
3.015267
Storage tank sensor kit (for managing the storage tank as a zone)
For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary
3.015268
Solar collector temperature probe kit
Positioned on the output of the solar manifolds, this device enables thecascade and zone regulator to controlthe temperature of the solar fluid
3.019374
External probe
Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function
3.024511
Anti freeze protection kit -15 °CUsable in outdoor installations forminimum temperature as low as -15 °C. One kit for every boiler
3.024513
SYSTEMS OF CONTROL AND HEAT ADJUSTMENT FOR INSTALLATION IN CASCADECentral heating systems or, in general, modular boilers installed in cascade formation, require an adequate system of heat adjustment capable of communicating in a practical, simple way with the boiler so as to satisfy the many and varied needs of the system. For this reason, the following accessories can be used with the VICTRIX PRO installation to control the central heating system and optimize climatic regulation.
17
ACCESSORIES
HYDRAULIC COMPONENTS FOR SINGLE INSTALLATIONThe following hydraulic accessories are supplied as optionals to complete the individual installation of a VICTRIX PRO.
Type Description Code
Safety kit single boiler
The kit Includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard
3.023949
Three-way valve kit connection to a separate storage tank
The kit Includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard
3.023950
Hydraulic manifold kit forVICTRIX PRO 55 Specially sized for large thermal systems
with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard
3.023951
Hydraulic manifold kit forVICTRIX PRO 80-100-120 3.023952
IPX4D protection box kit for single boiler safety kit 3.024028
Condensate neutralizer kit for single installation
Necessary to neutralize the acidity of the condensation. Inclusive of granulate 3.019857
Granulate for condensate neutralizer Extra granulate for condensationpassivator kit code 3.019857 3.019865
“Free standing” support frame kit VIC-TRIX PRO
Designed to resolve installation situations in which the wall of the furnace room is not usable.
With this modular construction, it is necessary to order a kit for every boiler installed.
Approved also for installation outside the building.
3.024246
18
ACCESSORIES
Type Description Code
Hydraulic manifold kit G 2 ½”for 2 VICTRIX PRO 55 in cascade
Kit for connection of 2 VICTRIX PRO 55 in cascade installation; includes a 2-way valves, a 3-way interception valve and a non-return valve for each generator.Insulation as standard
3.023953
Hydraulic manifold kit G 2 ½”for additional VICTRIX PRO 55in cascade
In combination with kit 3.023953, it serves to connect from 3 to 5 VICTRIX PRO 55 boilers in cascade installation (one kit required for each additional boiler); includes a 2-way interception valve, a 3-way interception valve and a non-return valve. Insulation as standard
3.023954
Safety kit G 2” ½ for VICTRIX PRO55 in cascade
The kit Includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard
3.023955
Hydraulic manifold kit DN 100 for 2VICTRIX PRO 80/100/120 in cascade
Kit to connect 2 VICTRIX PRO 80/100/120 in cascade installation; it includes a 2 way interception valve, a 3-way interception valve and a non-return valve for each generator.Insulation as standard
3.023959
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 80/100/120in cascade
In combination with kit 3.023959 serves to connect from 3 to 5 VICTRIX PRO 80/100/120 boilers in cascade installation (one kit required for each additional boiler); includes a 2-way interception valve, a 3-way interception valve and a non-return valve.Insulation as standard
3.023960
Safety kit DN 100 for VICTRIX PRO80/100/120 in cascade
The kit Includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard
3.023961
IPX4D protection box kit for cascade safety kit 3.024038
HYDRAULIC COMPONENTS FOR CASCADE INSTALLATIONThe following hydraulic accessories are supplied as optionals for completion of cascade installations from 2 up to 5 VICTRIX PRO.
19
ACCESSORIES
Type Description Code
Condensate neutralizer kit for cascade installation
Necessary to neutralize the acidity of the condensation. Inclusive of granulate 3.019464
Granulate for condensate neutralizer
Extra granulate for condensation passivator kit code. 3.019464(in case of cascade installation wesuggest to buy 2 kits)
3.019865
Hydraulic separator for upto 100 kWinstallations
Separator with G2 ½” threadedconnectors.Insulation as standard.
3.020839
Hydraulic separator for upto 240 kWinstallations
Separator with G2 ½” threadedconnectors.Insulation as standard.
3.021377
Hydraulic separator for upto 400 kWinstallations
Separator with G2 ½” threaded connectors on boiler side - DN 100 on system side.Insulation as standard.
3.021378
Hydraulic separator for 350 kWinstallations
Separator with threaded connectors -DN 100.Insulation as standard.
3.023965
Hydraulic separator for 600 kWinstallations
Separator with threaded connectors -DN 100.Insulation as standard.
3.023962
“Free standing” support frame kit VIC-TRIX PRO
Designed to resolve installation situations in which the wall of the furnace room is not usable.
With this modular construction, it is necessary to order a kit for every boiler installed.
Approved also for installation outside the building.
3.024246
HYDRAULIC COMPONENTS FOR CASCADE INSTALLATION CONT.
20
FLUE SYSTEM
Maximum distance (metres)*
Type VICTRIXPRO 55 1 I
VICTRIXPRO 80 1 I
VICTRIXPRO 100 1 I
VICTRIXPRO 120 1 I
Terminal verticaloutlet outdoor kit Ø 80
Code 3.024295
30 28 14 8,5
Terminal horizontal outlet kit Ø 80(to discharge horizontally)
Code 3.015255
30 28 14 8,5
Maximum distance (metres)*Type VICTRIX
PRO 55 1 IVICTRIXPRO 80 1 I
VICTRIX PRO 100 1 I
VICTRIXPRO 120 1 I
Vertical concentrickit Ø 80/125
Code 3.015243
18 15 11 6
Horizontal concentric kit Ø 80/125(internal application)
Code 3.015242
14,4 11 8 5
Horizontal concentric kit Ø 80/125(external application)
Code 3.025422
- - - -
CONFIGURATION B23 - OPEN CHAMBER, FAN ASSISTED
CONFIGURATION C - SEALED CHAMBER, FAN ASSISTED
“GREEN SERIES” FITTED FLUE SYSTEMVICTRIX PRO offers a dedicated set of kits for air suction/fume exhaust called “Green Series” by Immergas, with parts and accessories in materials specific for this type of boiler.The kits are built to guarantee high resistance to corrosion, ease of installation and functional fit, thanks also to the bayonet fastening system and special sealing gaskets.
VICTRIX PRO boilers are approved type “B23” (with open chamber, fan assisted). They therefore need only a single flue exhaust outlet. If necessary this can be “C” - shaped to function like sealed chamber equipment, fan assisted.
* Additional parts of the flue system are available (such as flexible inside pipes Ø 80, 90° angle bends, 45° degree angle bends, etc.) in which case the maximum admissible length decreased by a quantity equal to its “equivalent length”. For more information refer to the documentation supplied with the boiler.
21
FLUE SYSTEM
Type Description Code
Exhaust manifold kit 2 VICTRIX PRO 55 Ø 160 with flue lock
Serves for exhaust connection of two boilers in cascade 3.024279
Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lock
Serves for exhaust connection of two boilers in cascade 3.024281
Additional exhaust manifold kit VICTRIX PRO 55 Ø 160 with flue lock
For connection of an additional boiler (see also page 25) 3.024280
Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lock
For connection of an additional boiler(see also page 25) 3.024282
Additional exhaust manifold kit VICTRIXPRO 100/120 Ø 250 with flue lock for 4 VICTRIX PRO 100/120
3.024666
Additional exhaust manifold kit VICTRIXPRO 100/120 Ø 250 with flue lock for 5 VICTRIX PRO 100/120
3.024667
Extension pipe Ø 160 kit 0,5 m longfor flue manifold 3.024659
Extension pipe Ø 200 kit 0,5 m longfor flue manifold 3.024663
Extension pipe Ø 160 kit 1 m longfor flue manifold 3.024516
Extension pipe Ø 200 kit 1 m longfor flue manifold 3.024662
Extension pipe Ø 250 kit 1 m longfor flue manifold 3.024668
87° bend kit Ø 160 for flue manifold 3.024517
87° bend kit Ø 200 for flue manifold 3.024665
87° bend kit Ø 250 for flue manifold 3.024670
No. 2 45° bend kit Ø 160 forflue manifold 3.024518
No. 2 45° bend kit Ø 200 forflue manifold 3.024664
No. 2 45° bend kit Ø 250 forflue manifold 3.024669
CASCADE INSTALLATION – “GREEN SERIES” EXHAUST MANIFOLDSWith installations in central heating systems, using up to 5 units in the battery, in configuration B23 (open chamber fan assisted), Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers. The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.
22
The table below specifies the codes and quantities of exhaust manifold kits necessary, depending on the number of boilers installed in cascade.
Number of boilersExhaust manifold kit 2 VICTRIX PRO55 Ø 160 with flue lockCode 3.024279
Additional exhaust manifold kit VICTRIX PRO 55 Ø 160 with flue lockCode 3.024280
2 VICTRIX PRO 55 1
3 VICTRIX PRO 55 1 1
4 VICTRIX PRO 55 1 2
5 VICTRIX PRO 55 1 3
Number of boilersExhaust manifold kit 2 VICTRIX PRO80/100/120 Ø 200 with flue lockCode 3.024281
Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lockCode 3.024282
2 VICTRIX PRO 80 1
3 VICTRIX PRO 80 1 1
4 VICTRIX PRO 80 1 2
5 VICTRIX PRO 80 1 3
Number of boilers
Exhaustmanifold kit 2 VICTRIX PRO100/120 Ø 200 with flue lock Code 3.024281
Additional exhaustmanifold kitVICTRIX PRO100/120 Ø 200 with flue lockCode 3.024282
Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 4 VICTRIX PRO 100/120Code 3.024666
Additional exhaustmanifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 5 VICTRIX PRO 100/120Code 3.024667
2 VICTRIX PRO 100-120 1
3 VICTRIX PRO 100-120 1 1
4 VICTRIX PRO 100-120 1 1 1
5 VICTRIX PRO 100-120 1 1 1 1
FLUE SYSTEM
DIMENSIONSCASCADE INSTALLATION
2 X VICTRIX PRO 80/100/120 - BOILERS IN CASCADE
Dimensions and connections
452
330
1279
2785
40033 800 442
Ø 200
904
702
500
2100
2504
4
8
3
5
2
1 1
6
3°
9
710
To be connectedUnit DHW tank
Key
1 Boiler 4 Hydraulic separator 7 Cascade and zone regulator kit 10 Storage tank sensor kit
2 Hydraulic manifold kit DN 100 5 Condensate neutralizer kit for cascade installation
8 Flow probe
3 Safety kit DN 100 for boilersin cascade
6 Exaust manifold kit 9 External probe
452
330
1279
2785
40033 800 800 442
Ø 200
904
702
500
2900
3304
4
8
3
5
2
1 1 1
6
3°
9
710
To be connectedUnit DHW tank
Key
1 Boiler 4 Hydraulic separator 7 Cascade and zone regulator kit 10 Storage tank sensor kit
2 Hydraulic manifold kit DN 100 5 Condensate neutralizer kit for cascade installation
8 Flow probe
3 Safety kit DN 100 for boilersin cascade
6 Exaust manifold kit 9 External probe
3 X VICTRIX PRO 80/100/120 - BOILERS IN CASCADE
24
DIMENSIONSCASCADE INSTALLATION
Dimensioni e attacchiDimensions and connections
4 X VICTRIX PRO 80/100/120 - BOILERS IN CASCADE45
233
012
79
2785
40033 800 800 800 442
Ø 200
1010
755
500
3700
4210
4
8
3
5
2
1 1 1 1
6
3°
9
710
To be connectedUnit DHW tank
Key
1 Boiler 4 Hydraulic separator 7 Cascade and zone regulator kit 10 Storage tank sensor kit
2 Hydraulic manifold kit DN 100 5 Condensate neutralizer kit for cascade installation
8 Flow probe
3 Safety kit DN 100 for boilersin cascade
6 Exaust manifold kit 9 External probe
452
330
1279
2785
422
40033 800 800 800 800 442
Ø 200
1010
755
500
4500
5010
4
8
3
5
2
1 1 1 1 16
3°
9
710
To be connectedUnit DHW tank
Key
1 Boiler 4 Hydraulic separator 7 Cascade and zone regulator kit 10 Storage tank sensor kit
2 Hydraulic manifold kit DN 100 5 Condensate neutralizer kit for cascade installation
8 Flow probe
3 Safety kit DN 100 for boilersin cascade
6 Exaust manifold kit 9 External probe
5 X VICTRIX PRO 80/100/120 - BOILERS IN CASCADE
25
DIMENSIONSCASCADE INSTALLATION
4 X VICTRIX PRO 120 - BACK TO BACK
32
Dimensions and connections
26
DIMENSIONSCASCADE INSTALLATION
32
Ref
eren
ce2
boile
rs3
boile
rs4
boile
rs5
boile
rs
X21
3029
3037
3045
30
6 X VICTRIX PRO 120 - BACK TO BACK
Dimensions and connections
27
8 X VICTRIX PRO 120 - BACK TO BACK
32
Ref
eren
ce2
boile
rs3
boile
rs4
boile
rs5
boile
rs
X21
3029
3037
3045
30
Dimensions and connections
DIMENSIONSCASCADE INSTALLATION
28
DIMENSIONSCASCADE INSTALLATION
10 X VICTRIX PRO 120 - BACK TO BACK
Dimensions and connections
29
EXAMPLE SCHEMATICS
3.01
5266
EXTE
RN
AL
PRO
BE
VIC
TRIX
PR
O 5
5
3.02
3949
SAFE
TY K
IT
3.02
3950
3 W
AY V
ALV
E K
IT
EXPA
NSI
ON
TA
NK
OPT
ION
AL
RE-
CIR
CU
LATI
ON
PU
MP
UB
INO
X 20
0V
- P
OW
ER S
UPP
LYA
C -
DO
MES
TIC
HO
T W
ATER
OU
TLET
RU
- ST
OR
AG
E TA
NK
CO
IL R
ETU
RN
MU
- ST
OR
AG
E TA
NK
CO
IL F
LOW
AF
- D
OM
ESTI
C W
ATER
INLE
TR
P -
RET
UR
N T
O S
OLA
R C
OLL
ECTO
RS
(O
PTIO
NA
L)M
P -
FLO
W F
RO
M S
OLA
R C
OLL
ECTO
RS
(O
PTIO
NA
L)R
C -
DH
W R
E-C
IRC
ULA
TIO
N K
IT
AU
TOM
ATIC
FI
LLIN
G
SYST
EM
DIM
V2
AB
TV
- P
OW
ER S
UPP
LYM
G -
FLO
W F
RO
M B
OIL
ERR
G -
RET
UR
N T
O B
OIL
ERF
-
ZON
E 1
FLO
W (H
IGH
TEM
P)A
-
ZON
E 1
RET
UR
NE
-
ZON
E 2
FLO
W (L
OW
TEM
P)C
-
ZO
NE
2 R
ETU
RN
D
- Z
ON
E 3
FLO
W (L
OW
TEM
P)B
-
ZO
NE
3 R
ETU
RN
3.02
1622
CR
ON
O 7
3.02
1622
CR
ON
O 7
3.02
1622
CR
ON
O 7
ZON
E 1
ZON
E 2
ZON
E 3
Single boiler with DHW and zoned heating
Not
e: T
he d
iagr
am p
rovi
ded
here
is in
dica
tive,
indi
vidu
al re
quire
men
ts b
ased
on
spec
ific
desi
gn a
nd in
stal
latio
n co
nditi
ons
may
var
y.
30
EXAMPLE SCHEMATICS
KE
Y:
1 -
VICT
RIX
PRO
Boi
ler
2 -
Cron
o 7 -
ther
mos
tat
3
- Ex
tern
al pr
obe
4
- Sa
fety
kit
5
- At
tach
men
t for
expa
nsio
n ve
ssel
6
- Sy
stem
expa
nsio
n ve
ssel
7
-
8 -
Hyd
raul
ic se
para
tor
9
-
10
- Sy
stem
pum
p
11
-
12
- Co
nden
sate
neu
tralis
er
13
- U
B IN
OX
stora
ge ta
nk
14
- Te
mpe
ratu
re pr
obe f
or st
orag
e tan
k uni
t upp
er
part
15
-
Tem
pera
ture
pro
be fo
r st
orag
e ta
nk u
nit
lowe
r par
t
16
-
17
-
18
- Ex
pans
ion v
esse
l, sa
fety v
alve a
nd no
n retu
rn
valve
for t
he d
omes
tic h
ot w
ater
circ
uit
19
-
Solar
man
ifold
pro
be
20
- Ai
r ven
t valv
e
21
- Fl
at so
lar co
llect
ors
22
-
Regu
latin
g sol
ar co
ntro
l uni
t
23
- Si
ngle
solar
circ
ulat
ion
unit
24
-
Solar
expa
nsio
n ve
ssel
Cond
ensa
te d
rain
Gas
inlet
Syste
m F
illin
g
Flow
to th
e hea
ting
syste
mRe
turn
to th
e he
atin
g sy
stem
Main
s wate
r inle
t
�re
e way
valve
kit
Gas s
hut o
� va
lve
Wat
er in
let sh
ut o
�
25
- Co
mm
on �
ow p
robe
Single boiler with solar DHW and heating
Not
e: T
he d
iagr
am p
rovi
ded
here
is in
dica
tive,
indi
vidu
al re
quire
men
ts b
ased
on
spec
ific
desi
gn a
nd in
stal
latio
n co
nditi
ons
may
var
y.
31
EXAMPLE SCHEMATICS
K
EY:
1
- V
ICTR
IX P
RO B
oiler
2
- Ex
tern
al p
robe
3
- Sy
stem
inte
rcep
tion
cock
4
-
5 -
Non
retu
rn v
alve
6
- Sa
fety
kit
7
- At
tach
men
t fo
r ex
pans
ion
vess
el
8 -
Syste
m ex
pans
ion
vess
el
9 -
10
- C
onde
nsat
e neu
tral
iser k
it
11 -
Hyd
raul
ic se
para
tor
12
-
13
-
14
- M
ixin
g va
lve z
one 1
15
- T
emp.
pro
be zo
ne 1
16
- H
eatin
g circ
uit p
ump
zone
1
17 -
Saf
ety
ther
mos
tat
mix
ed
zone
18
- M
ixin
g va
lve z
one 2
19
- T
emp.
pro
be zo
ne 2
20
- H
eatin
g circ
uit p
ump
zone
2
21 -
Hea
ting c
ircui
t pum
p zo
ne 3
22
- S
tora
ge ta
nk fe
edin
g pu
mp
23
- C
asca
de an
d zo
ne re
gulat
or
24 -
25 -
Zon
e man
ager
26
- ki
t
27 -
UB
INO
X sto
rage
tank
28
- T
emp.
pro
be u
pper
par
t
29
- Te
mp.
pro
be lo
wer
par
t
30 -
31 -
Exp
ansio
n ve
ssel,
safe
ty va
lve
and
non
retu
rn v
alve
for t
he
dom
estic
hot
wat
er ci
rcui
t
32 -
Sol
ar m
anifo
ld te
mp.
pro
be
33 -
Air
vent
val
ve
34 -
Flat
sola
r col
lecto
rs
35 -
Sin
gle s
olar
circ
ulat
ion
unit
36 -
Sol
ar ex
pans
ion
vess
el
Gas
inlet
Syste
m fi
lling
ZONE
1ZO
NE 2
ZONE
3
Main
s wate
r inle
tCo
nden
sate
dra
in
Gas
shut
o�
valv
e
Wat
er in
let sh
ut o
�
Cascade boiler setup with solar DHW and zoned heating
Not
e: T
he d
iagr
am p
rovi
ded
here
is in
dica
tive,
indi
vidu
al re
quire
men
ts b
ased
on
spec
ific
desi
gn a
nd in
stal
latio
n co
nditi
ons
may
var
y.
32
EXAMPLE SCHEMATICS
K
EY:
1
- V
ICTR
IX P
RO B
oile
r
2
- Exte
rnal
pro
be
3
- Syste
m in
terc
eptio
n co
ck
4
-
5 - N
on re
turn
val
ve
6
- Safe
ty k
it
7
- Atta
chm
ent f
or ex
pans
ion
vess
el
8
- Syste
m ex
pans
ion
vess
el
9
-
10 - C
onde
nsat
e neu
tral
iser k
it
11
- Hyd
raul
ic se
para
tor
12
-
13
- C
omm
on �
ow t
emp.
pr
obe
14
- M
ixin
g va
lve
15
- T
emp.
pro
be zo
ne 1
and
2
16 -
Hea
ting
cir
cuit
pum
p zo
ne 1
and
2
17 -
Saf
ety
ther
mos
tat m
ixed
zo
ne 1
and
2
18 -
Cen
tral
hea
ting
circ
uit
pum
p
19 -
Sto
rage
tan
k fe
edin
g pu
mp
20
- C
asca
de an
d zo
ne re
gula
tor
21
- Zone
man
ager
Con
dens
ate d
rain
Gas
inle
t
Gas
inle
t
Con
dens
ate d
rain
Main
s wat
erin
let
ZON
E 1
ZON
E 2
ZON
E 3
ZON
E 4
ZON
E 5
Syst
em F
illin
g
22
-
23
- R
elay
box
24
-
25
- E
xpan
sion
ves
sel,
safe
ty
valv
e and
non
retu
rn v
alve
fo
r th
e do
mes
tic h
ot w
ater
ci
rcui
t
26 -
Nor
mal
ly c
lose
d w
ater
inle
t shu
t o�
27
- T
emp.
pro
be U
B IN
OX
uppe
r par
t
28 -
UB
INO
X sto
rage
tank
uni
t
29 -
kit
31
- T
emp.
pro
be U
B IN
OX
low
er p
art
32
- A
ir ve
nt v
alve
33
- S
olar
colle
ctor
s tem
p. p
robe
34
- F
lat s
olar
colle
ctor
s
35 -
Sin
gle
sola
r ci
rcul
atio
n un
it
36
- So
lar e
xpan
sion
vess
el
Gas
shut
o�
valv
e
Wat
er in
let s
hut o
�
30-
UB
INO
X s
tora
ge t
ank
unit
Cascade boiler setup with large scale solar DHW
Not
e: T
he d
iagr
am p
rovi
ded
here
is in
dica
tive,
indi
vidu
al re
quire
men
ts b
ased
on
spec
ific
desi
gn a
nd in
stal
latio
n co
nditi
ons
may
var
y.
33
NOTES
NOTES
Imm
erga
s re
serv
es th
e rig
ht to
mak
e su
ch c
hang
es to
its
prod
ucts
are
dee
med
nec
essa
ry fo
r the
ir ev
olut
ion,
with
out p
rior n
otic
e. C
E.04
42 -
rev.
001
(ver
. 591
) - 1
2/13
ai
cod.
it
11 Fiveways BlvdKeysboroughVictoria3173
T: 1300 00 1800 or (+61 3) 9798 5111F: (+61 3) 9798 5133E: enquiries@huntheat.com.auwww.huntheat.com.au
Recommended