PANEL CUBIERTA ISOVER 175 - Aislamiento …PANEL CUBIERTA ISOVER 175 Roofing Thickness d, mm Stated...

Preview:

Citation preview

DescriptionRigid non-absorbent unlined ISOVER stonewool panel. Resistant to compression (allowing rooftop access).

Applications Due to its outstanding thermal-acoustic and mechanical properties, the Isover 175 Roof Panel is the perfect choice for: · Flat and conventional sloping roofs on collective residential

buildings and single-family housing units. For trafficable roofs, roofs for private use, tar and gravel roofs and roof underlays.

· Suitable for metal roofs and on-site «sandwich» constructions.· Suitable for supporting compression strength of light vehicles.

Technical properties

Symbol Parameter Icon Units Value Standard

lD

Stated thermal conductivity W/m·K 0,040 EN 12667 EN 12939

Cp

Approximate specific heat J/kg·K 800 –

AFR Airflow resistance kPa·s/m2 > 5 EN 29053

Reaction to fire Euroclass A1 EN 13501-1

WS Short-term water absorption kg/m2 < 1 EN 1609

MU Steam diffusion resistance, µ 1 EN 12086

SD Dynamic rigidity MN/m3 10 EN 29052-1

CP Compressibility, c mm < 5 EN 13162 y EN 12431

CS Compressive strength at 10% deformation, σ

10

Kpa 65EN 826

Kg/m2 6.500

DS Dimensional stability, De % < 1 EN 1604

Advantages· Optimum thermal and acoustic insulation for roofing. · Especially recommendable for light roofing. · High resistance to compression.· Sustainable product, manufactured from recycled material.· Inert material ensures an inhospitable environment for micro-

organisms.· Maintains unaltered system performance throughout the useful

life of the building, with no drop-off over time.

Certificates

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•Qualité

del'a

irin

térie

ur· Calidad aire interior ·Q

ualityInterior• Aislante térmico

ProductoCertificado

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

LeedBreeamVerde

Installation guideFor further information: www.isover.es

Presentation

PANEL CUBIERTA ISOVER 175Roofing

Thicknessd, mm

Stated thermal conductivityR

D ,

m2·K/W

Acoustic absorption coefficient, AW, a

w

Designation code

EN 823EN 12667 EN 12939

EN ISO 354 EN 13162

40 1,00 0,70 MW-EN 13162-T6-DS (70,90)-WS-MU1-SD10-CP5-AW0,70-AFr5 50 1,25 0,70

Thickness d (mm)

Lengthl (m)

Width b (m)

m2/ pack

m2/ pallet

m2//truck

40 1,20 1,00 4,80 72,00 1.872

50 1,20 1,00 4,80 57,60 1.498

Sain

t G

obai

n Is

over

Ibér

ica,

S.L

. res

erve

s th

e ri

ght

to m

odif

y, t

otal

ly o

r p

arti

ally

an

d w

ith

out

pri

or n

otifi

cati

on, t

he

info

rmat

ion

con

tain

ed in

th

is d

ocu

men

t. S

imila

rly,

th

e co

mp

any

can

not

gu

aran

tee

the

abse

nce

of

any

invo

lun

tary

err

or. 1

7/02

/16

Construimos tu Futuro

+34 901 33 22 11

www.isover.es

isover.es@saint-gobain.com

www.isover-aislamiento-tecnico.es

@ISOVERes

isoveresISOVERaislamientoISOVERaislamiento

Recommended