OpenLAB CDS - Agilent · How Does OpenLAB CDS ChemStation Edition Address ... • The master method...

Preview:

Citation preview

OpenLAB CDS ChemStation Edition Overview

Jon Welsh Agilent Informatics

1

How Does OpenLAB CDS ChemStation Edition Address Other Lab Needs? An Enterprise-wide Chromatography Data system • Fully scalable from stand-alone workstation to Distributed System • Easily connects to Data Store or ECM for central data storage and regulatory

compliance with GLP/GMP and 21 CFR Part 11 • Multi-technique: Control of Agilent GC, LC, CE, LC/MS, CE/MS, SFC • Tight instrument integration • Flexible report generation tools for custom calculations, sequence summary and

single run reporting • Macro language

Page 2

OpenLAB CDS Workstation Configuration

Page 3

OpenLAB CDS: Networked Workstation Configuration

Page 4

OpenLAB CDS: Fully Distributed Configuration

Page 5

OpenLAB CDS ChemStation Edition – A Scalable Part of the LI Family Features

• All Data and Methods generated by any version of ChemStation rev. B are compatible.

• The UI and workflow of OpenLAB CDS is very familiar and doesn’t change in scaling or adding Data Store or ECM for storage.

Benefit

• Customers have a smooth migration path from single workstation to a Networked System with or without Data Store / ECM.

Page 6

Multi-Technique Instrument Control

Many Instruments - One Enterprise Software

Page 7

• One user interface • Lab-at-a-glance view of the lab • Identical look & feel – independent of

the hardware • Easy to learn and use • Central administration • Central place to configure data storage

Roles & Privileges

• ChemStation roles and privileges are managed in OpenLAB Control Panel and can be used without OpenLAB ECM or Data Store.

• Support for local and domain user authorization.

• Grouping of instruments into locations.

• Define access security for each location in the tree.

Page 8

Data Organization – What’s in a Result Set?

• The master method is copied at the start of the sequence to create a sequence method.

• Any changes made during data analysis (e.g., during an update of the calibration table) are saved into the sequence method.

• The acquisition method is stored in ACQ.txt.

• The individual Data Analysis Method (DA.M) preserves the last data analysis parameter to re-create the last version of the results for a specific data file.

Page 9

Usability: Introducing Workflows

Review View • ChemStation Review View • Uses Intelligent Reporter to show results

Data Analysis View

Recalculation Mode - Flexible • Recalculate peak results in the navigation table with one or several different methods • Shortcut to recalculate all data in the navigation table with a single method • Manually step through navigation table or use auto-stepping to review

Reprocessing Mode - Traceable • Reprocess the sequence with different method(s) to update or modify calibration • Add new or changed methods to result set and reprocess the whole or partial sequence • Store and manage all result and method revisions with sequence/result set

Page 10

Review View

Page 11

Key Benefit: Preview or print reports without reprocessing and get your reports 10 times faster!

Select report template(s) and data-files and get

immediately answers on complete experiments!

Recalculate Mode

Page 12

Any method can be loaded from the tree

“autostepping” toolbar

Switch between Recalculation and Reprocessing Mode

“Recalculate” menu

Key benefit: quickly apply multiple methods to a self-defined set of runs

Reprocess Mode

Page 13

New tree with current sequence methods; quickly add master methods to the result set

Key benefit: Easy way to reprocess and recalibrate complete sequence

Switch between modes “sequence reprocessing” toolbar

Self-Assembled Data Sets and Result Sets

Self-assembled Data Set

• Use “Add” functionality to add data from different sources

• Reprocess/recalculate and report over self-assembled set of data assembled from different folders [not possible in strict 21 CFR part 11 workflow!].

Self-assembled Result Set

• A self-assembled data set can be turned into a self-assembled result set.

• Always available for cross-sample calculations and uploading into Data Store or ECM.

• Supports cross-sequence review in 21 CFR part 11 workflow

Page 14

• Select data files in the navigation table

Self-Assembled Result Set

Page 15

• Select the method and destination folder • Launch Create New Result Set… dialog

Sequence Queuing

• The Run Queue now also supports ChemStation sequences. You can directly schedule a single sequence, or process all sequences given in a Queue Plan.

• Select a sequence template to be added to the queue (online only)

Page 16

Run Queue • Single Samples can now

be added to the Run Queue.

• Run Method / Run Sequences are submitted to the queue.

Page 17

Queue Planner

• The Queue Planner allows setting up the relevant sequences and queueable pauses in a queue plan

• Load, create and save queue plans (as *.qpl file)

• Available in online and offline

Page 18

Queueable pause

Easy Sequence

Native Sequence

METHOD HANDLING

OpenLAB CDS ChemStation Edition

Page 19

Method Download

• Upon instrument startup, users are given a choice: • download the ChemStation

method to the instrument • upload the instrument method

to ChemStation • create a new method from

instrument method • A differences viewer highlights

the differences between the ChemStation method and the instrument method.

OpenLAB CDS ChemStation Edition – Acquisition Method Viewer Problem I need to review the Acquisition Method parameters before downloading to the instrument. I do not want to trigger Method Resolution.

Solution Acquisition Method Viewer-provides a way to view the acquisition method parameters.

Page 21

OpenLAB CDS ChemStation Edition – Single Sample Workflow • The Navigation Table now shows the acquisition method as

well as the data analysis method.

• A fly-over indicates the path to the data analysis method.

Page 22

OpenLAB CDS ChemStation Edition

STORAGE OPTIONS

Storage Option Review

File System

• Simple configuration supports Workstation and Networked Workstation

Data Store

• Compliant workgroup solution: Compliance with GLP/GMP and 21 CFR part 11

• Includes sophisticated search support

ECM

• The Enterprise data repository

• Compliance with GLP/GMP and 21 CFR part 11

• Includes sophisticated search support

Page 24

• Download any result set or single run from Data Store (or ECM) to the local ChemStation file system.

• The downloaded data can be reviewed and reprocessed, since the result set contains all necessary files.

Data that have been uploaded to Data Store (or ECM) have a different icon in the tree view.

OpenLAB CDS ChemStation Edition – Integration with Data Store or ECM

Page 25

For more Information

OpenLAB CDS ChemStation Edition web page

Page 26

Title: Agilent OpenLAB CDS eFamiliarization DVD P/N: M8301-60032 This DVD includes a set of eFamiliarization modules for OpenLAB CDS ChemStation and EZChrom Editions Literature Type: DVD Language: English (currently shipping) Chinese & Japanese (ships in Feb. 2014) Target Audience: Agilent customers who need basic overview of the software operations and functions.

What’s New in OpenLAB CDS A.01.06

Support for Windows 7 and 8

Improvements to sequence handling

• Refreshed Sequence Table [CS]

• Full sequence rollout [CS]

Targeted Customer & Support Enhancements

• Improved bar code handling [CS]

• Recoverable error handling for GC

• Improved display of driver versions

Instrument Control

Intelligent Reporting Updates

OpenLAB Data Analysis A.01.02 • Expand support for HPI • Integration with Data Store

Integration with OpenLAB Data Store A.02.01 • Expansion of database compatibility to

PostgreSQL

OpenLAB CDS Secure ChemStation Workstation [CS] = ChemStation Edition [EE] = EZChrom Edition

November 2013 27

OpenLAB CDS A.01.06 Agilent Restricted

Customer Experience

• Stop the GC and Continue the Sequence

• Recoverable error handling

Continue Abort and Continue Queue Abort

Skip Pause Abort and Continue Queue Abort

28

Customer Experience

• Improve customer experience of ChemStation sequence table [CS]

• Sequence rollout [CS]

Barcode Reading – Chain of Custody

June 19, 2013 30

• Enter sample information including the sample name into the sequence table

• 7693 ALS with 7890B reads barcode

• CDS compares the Barcode field (Actual) to the sample name (Expected) and determines mismatched values

• Logic determines whether to inject or not and prints results on the reports

• True = prints “barcode match” • False = prints “barcode

mismatch” ChemStation Edition

Recommended