OEM LOADCENTER INTERIOR ASSEMBLIES
CIRCUIT BREAKERS AND ACCESSORIES
Page 1
OEM INTERIORASSEMBLIES
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OEM Loadcenter Interior Assemblies
Type CH Indexpage(s)
Type BR Index
Type CH OEM LoadcenterInterior Assemblies ....................................... 4
Type CH Loadcenter Accessories ..................... 5
Type CH Circuit Breakers .................................. 6
Plug-On .......................................................... 7
Plug-On Special Application ................... 7-11
Accessories ................................................. 12
Type CH Interior Assemblies
Single-Phase, Single-RowCopper Bus, 70 and 125 Amp .................... 13
Single-Phase, Double-RowCopper Bus, 125, 200 and 225 Amp ..... 14-18
Three-Phase, Double-RowCopper Bus, 125 and 225 Amp ............. 19-21
Surge Protectors ............................................. 46
Type BR OEM LoadcenterInterior Assemblies ..................................... 22
Type BR Loadcenter Accessories ................... 23
Type BR Circuit Breakers ................................ 24
Plug-On ............................................... 25 & 30
Plug-On Special Application ...... 26, 27, & 30
Plug-On Duplex, Quadplex .................. 28, 29
Accessories ................................................. 31
Type BR Interior Assemblies
Single-Phase, Single-RowAluminum Bus, 70 and 125 Amp ......... 32, 33
Single-Phase, Double-RowAluminum Bus,125, 200 and 225 Amp ........................... 34-39
Single-Phase, Double-RowCopper Bus, 125 and 200 Amp ............ 40, 41
Three-Phase, Double-RowAluminum Bus,125, 150, 200 and 225 Amp ................... 42-44
Three-Phase, Double-RowCopper Bus, 125 and 200 Amp .................. 45
Surge Protectors ............................................. 46
page(s)
OEMPage 2
INTERIORASSEMBLIES
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Two Products OfferDesign FlexibilityAs a manufacturer of two lines ofloadcenters, we are in a uniqueposition to offer the broadest rangeof interiors in the market. Each linehas its own unique characteristicsthat appeal to various segments ofthe market. OEM interiors are ULrecognized components and are listedin either of the following UL files:E8741 or E52977.
The interiors are designed for eitherhorizontal (single-row breakermounting), or vertical (double-rowbreaker mounting). To comply withNational Electrical Code® (NEC)requirements if mounted horizontally,when the breaker is ON, the handleshould be in the UP position. Whenmounted vertically, the handle togglesfrom left to right, so this is not a concern.
Type CHThe CH interiors feature 100% copperbus and use the CH 3/4-inch wide(19.1 mm) circuit breaker, whichminimizes panel space. Recognizedby contractors for its sturdy design,the CH interior will appeal to thosecustomers seeking an industrialquality bolted bus bar and the spacesaving of 1/4-inch (6.4 mm) per busstab. With a typical 12 circuit CHinterior, this space savings amountsto an 1-1/2 inch (38.1 mm) savingsover its 1-inch (25.4 mm) counterparts.The stab rating of the CH interiors is140 amperes maximum, meaning thatthe handle rating of breakers mountedacross from one another may notexceed 140 amperes.
Type BRThe BR interiors are manufactured offormed, plated aluminum or copper,and use the Cutler-Hammer Type BR1-inch wide (25.4 mm) circuit breaker.This design affords customers themost circuit flexibility as many ofthese interiors allow the installationof standard 1- and 2-pole breakersas well as duplex (2 poles in a 1-inchspace, 25.4 mm), or quadplex (4 polesin a 2-inch space, 50.8 mm) breakers.The stab rating of the BR interiors is200 amperes maximum, meaning thatthe handle rating of the breakers thatare mounted across from one anothermay not exceed 200 amperes.
GeneralAs a leader in the electrical distribu-tion equipment business, Cutler-Hammer has a unique productoffering for equipment manufacturers,panel builders and virtually any OEMthat has a need for power distributionwithin their equipment. The OEMinterior offering consists of a widevariety of power distribution optionsutilizing components from Cutler-Hammer’s CH and BR Loadcenterproduct lines. With high-volume,standardized products, OEMs canexpect to receive high-qualityproducts in configurations meetingvirtually any power distribution need.
Coupled with Cutler-Hammer’sexpertise in circuit breaker designand manufacturing, our OEM interiorsprovide solid power distribution andcircuit protection in a compact, easy-to-install package. Interiors are offeredfrom 2 to 42 circuits, and from 70 to225 amperes.
QualityBuilt in our ISO 9002 certified manu-facturing facilities, customers can beassured of the process quality in placefor the manufacture of these products.Utilizing the latest in computer-controlled plating, painting, molding,stamping and welding processes,our customers have come to expectconsistent high quality from shipmentto shipment.
Ordering InformationCutler-Hammer OEM interiors are aseasy to order as they are to install.Customers place orders by catalognumber in multiples of the standardpackage quantities. The products areeither stocked in Cutler-Hammerwarehouses or are shipped directlyfrom the plant. For those panelsshipping directly from the plant,shipping lead time is 10 working days.Distributors should refer to VISTA orthe Cutler-Hammer Price andAvailability Digest for pricing. Forinteriors not shown in this catalog,contact your local Cutler-Hammersales engineer or the CustomerSupport Center at 1-800-356-1243.
Page 3
OEM INTERIORASSEMBLIES
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OEM Loadcenter Interior Assemblies
Specifications, ListingsClass CTLNEC Paragraph 384-15 requires branchcircuit panelboards to be providedwith physical means to prevent theinstallation of more overcurrentdevices than the number of which theenclosure was designed, rated andapproved. Class CTL duplex, quadplexand twin breakers (identified by acatalog number prefix BD, BQ, BQCand CHT) are equipped with a ULlisted rejection tab over the lineterminal. All OEM interiors haveappropriately notched stabs to acceptthese rejection tab Class CTL breakers.
Duplex, quadplex and twin breakersmanufactured without the rejectiontab (identified by a catalog numberprefix BR, BRD and CHNT) areavailable for replacement purposesin older interiors.
Federal SpecificationsAll loadcenter enclosures meetFederal Specifications W-P-115b,Type 1, and Class 2 requirements.
All 120/240V breakers, both 1-inch(25.4 mm), 1/2-inch (12.7 mm) and3/4-inch (19.1 mm) per pole meet therequirement of Federal SpecificationsW-C 375B/Gen Type 1.
Canadian Standards Association ListingAll 1-pole and 2-pole, 120/240Vbreakers, both 1-inch (25.4 mm),1/2-inch (12.7 mm) and 3/4-inch(19.1 mm) per pole, 225 amperemaximum, are listed as certified bythe Canadian Standards Association,Guide No. 69-11.19, Class 1432,File 18328.
Underwriters Laboratories Inc. ListingAll grounding bars manufacturedcomply with Underwriters LaboratoriesInc. standards and are listed underGuide No. DHJR, File E31424, Volume W,Section 17.
All circuit breakers 10 amperes andlarger comply with the UnderwritersLaboratories Inc. “Standard for BranchCircuit and Service Circuit Breakers”UL489, Guide No. 60 10.2 File E31424;and “Requirements for Wire Connec-tors and Soldering Lugs” UL486B,Guide No. 461 10-C File E7830.
All Cutler-Hammer breakers wheremarked, are suitable for use with60/75°C rated wire, unless otherwisespecified.
All devices comply with the 22,000 AIC– 10,000 AIC UL series connectedcomponents File DKSY2 of theRecognized Components Index.
NEC 384-15
Lighting and Appliance PanelboardsLighting and appliance branch circuitpanelboards are defined in NEC Article384 as “One having more than 10% ofits overcurrent devices rated 30amperes or less for which neutralconnections are provided.” Article 384also limits the number of overcurrentdevices (branch circuit poles) to amaximum of 42 in any one cabinet.When the 42 poles are exceeded, twoor more separate panels are required.
TYPE CH ASSEMBLIESPage 4
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CH 4 L 3 125 INT
OEM Loadcenter Interior Assemblies
Catalog Numbering System
OEM InteriorAmpere RatingSingle-Phase: Blank / Three-Phase: 3
Breaker TypeMaximum Single PolesMain Lug
70 2 2 E8741 (1) #8–#2 AWG Cu/Al 1 CH9MB270 1 13
125 2 2 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH2L125INT 2 13
Type CH OEM Loadcenter Interior Assemblies
Single-Phase Single-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire 125 4 4 E8741 (1) 2/0–#14 AWG Cu/Al 20 CH4L125INT 3 14
125 8 8 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH8L125INT 4 14
125 12 12 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH12L125INT 5 15
125 16 16 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH16L125INT 6 15
200 12 12 E8741 (1) 300 kcmil–#4 AWG Cu/Al 20 CH12L200INT 7 16
200 16 16 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH16L200INT 8 16
225 24 24 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH24L225INT 9 17
225 32 32 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH32L225INT 10 17
225 42 42 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH42L225INT 11 18
Three-Phase Double-Row Breaker Mounting – Copper Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta 125 12 12 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH12L3125INT 12 19
125 18 18 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH18L3125INT 13 19
125 24 24 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH24L3125INT 14 20
225 24 24 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH24L3225INT 15 20
225 30 30 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH30L3225INT 16 21
225 42 42 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH42L3225INT 17 21
Ampere Maximum Number UL Main Terminal Wire Size Range Standard Catalog Diagram ReferenceRating 1-Inch (24.5 mm) File (Per Phase) Package Number Spaces Single Poles Reference Cu/Al 60°C or 75°C Quantity Number Page
TYPE CH ASSEMBLIESPage 5
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
B
A .269(6.83)
.844(21.44)
2.360(59.94)
CL of Mounting Hole CL of Mounting Hole
1.187(30.15)
1.182(30.02)
B
A
2.000(50.80)
.156(3.96)
.688(17.47)
CLof
MountingHole
.269(6.83)
.344(8.74)
.844(21.44)
2.360(59.94)
1.750(44.45)
2.860(72.64)
.250(6.35)
.182 Diameter(4.62)
.120(3.05)
1.750(44.45)
.750(19.05)
.344(8.74)
CL of Mounting Hole
B
A
Neutral AssembliesAmpere UL Main Incoming Terminal Number of Terminals Standard Catalog Dimensions – Inches (mm)Rating File Wire Size Range Package Number
Reference 60°C or 75°C Quantity
125 E52977 #6–1/0 AWG Cu 10 – 20 10NEU125B 1 5.938 (150.83) 5.400 (137.16)#6–2/0 AWG Al
125 E52977 #6–1/0 AWG Cu 17 – 20 17NEU125B 1 8.388 (213.06) 7.850 (199.40)#6–2/0 AWG Al
125 E52977 #6–1/0 AWG Cu 20 – 20 20NEU125B 1 9.438 (239.73) 8.900 (226.06)#6–2/0 AWG Al
225 E52977 #1–300 kcmil Cu/Al 24 1 20 24NEU225B 2 10.913 (277.19) 10.300 (261.62)
225 E52977 #1–300 kcmil Cu/Al 35 1 20 35NEU225B 2 15.813 (401.65) 15.200 (386.08)
125 — — 4 2 1 BINA 3 2.266 (57.56) 0.594 (15.09)
#14–4 AWG #6–1/0 AWG Cu Figure Overall Length MountingCu/Al #6–2/0 AWG Al A B
Figure 1
Figure 3
Figure 2
Loadcenter Accessories
Add-on Lugs for Neutral Assemblies
Ground Bar Kits
1
Must be purchased in multiples of ordering quantities indicated.
2
Distance between mounting holes is 1-3/4 inches (44.5 mm).
3
For 1- and 3-phase 400 and 600 ampere applications.
4
Distance between mounting holes is 2-11/32 inches (59.5 mm).
Description Wire Size RangeCu/Al 60°C or 75°C
OrderingQuantity
1
CatalogNumber
Neutral/Ground LugAdd-On Neutral or Ground Lug
#2/0 Maximum#3/0 Maximum300 kcmil Maximum
111
NL20NL30NL300
Description(See Legend)
LengthInches (mm)
OrderingQuantity
1
CatalogNumber
dssssds
dssssdsj
dssssdssssss
dssssdssssssj
dssssdssssssssss
dssssdssssssssssj
dssssdsssssssssssssssss
dssssdsssssssssssssssssj
ofodofooofodofooofo
2.54 (64.5)3.59 (91.2)4.29 (109.0)5.34 (135.6)4.61 (117.1)5.69 (144.5)6.74 (171.2)8.14 (206.8)9.19 (233.4)5.78 (146.8)
1111111111
GBK5
2
GBK520
2
GBK10
2
GBK1020
2
GBK13
2
GBK14
2
GBK1420
2
GBK21
2
GBK2120
2
BRGBK39512
34
f d f f f k f d f k f f f
Ground Bar Legend
s
j
o
d
(3) #14
–
#10 Cu/Al or (1) #14 – #4 Cu/Al(1) #6
–
2/0 Cu/Al(1) #14
–
#6 Cu/Al or (2) #14 – #12 Cu/Al(1) 1/0
–
14 or (3) #10 – 12 Cu/Al(1) #14
–
1/0 Cu/Al or (3) #14 – #10 Cu/Al(1) #6
–
14 Cu/Al or (2) #1/0 – 14 Cu/AlMounting Hole
f
f
GBK14
BRGBK39512
k
Page 6
TYPE CH
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
CH Circuit BreakersCutler-Hammer Type CH plug-onbreakers are a 3/4-inch (19.1 mm)design with a UL listed 10 kA interrupt-ing rating. CH breakers can be used asmain or branch disconnect devices.Several ratings are SWD and HACRapproved. Typical ampacity range forCH breakers is 15 to 150 amperes.
CH-GF People Protection BreakersCutler-Hammer Type CH-GF (groundfault circuit breakers) combine state-of-the-art electronic technology witha circuit breaker mechanism in acompact 3/4-inch (19.1 mm) package.The CH-GF automatically senses hotwire-to-ground faults in a 4 to 6 mArange and disconnects the power, thusproviding an extra margin of safetybeyond that of conventional circuitbreakers. CH-GF applications includebathrooms, cellar outlets, swimmingpools, outdoor branch circuits andkitchen branch circuits. Available in ULlisted 120 and 120/240V ratings. Cutler-Hammer also offers non-UL listedground fault breakers for internationalapplications as well as ground faultdevices for equipment protection.
CH-EPD Equipment ProtectionBreakersThe Cutler-Hammer Type CH-EPDdevice is similar to the CH-GP exceptthat it is designed to protect equip-ment (not people) against damagefrom arcing ground faults. It isavailable with a 30 mA trip level.Applications include infrared heatingequipment, process control equip-ment, etc.
Special Application BreakersAs the name implies, these devices aredesigned for special applications as re-quired by the National Electrical Code.
Neutral Switching BreakerPrimary application for the Cutler-Hammer switching neutral breaker isfor protection of process equipmentsuch as gas pumps that utilizeflammable liquids. Non-automaticpole breaks the neutral power leg,minimizing the danger of arc conditions.
2-Pole Breakers 120V or More to GroundUsed on Delta distribution systems,these Type CH breakers are applied onphase legs where voltage-to-ground isabove 120V.
Arc Fault Circuit Interrupters (AFCIs)Reduce the risk of fire by detectingand interrupting electrical arcing faultswhich standard thermal magneticbreakers cannot. For more informa-tion, see page 9.
CH-HM BreakersCH-HM breakers are designed withhigh magnetic trip settings. Single-and 2-pole CH-HM breakers (“HM”suffix) rated 15 and 20 amperes arerecommended for circuits withinherently high inrush currents.
CH-M50 BreakersCH-M50 breakers are designed tooperate at a maximum temperatureof 50°C. Single- and 2-pole CH-M50breakers (“M50” suffix) rated 15 to50 amperes are recommended forapplications where the ambienttemperatures are above 40°C.
CHP BreakersCHP breakers are designed with athree-position commercial trip (on-tripped-off). Single-, 2- and 3-poleCHP breakers rated 10 to 70 amperesare recommended for applicationsrequiring a breaker center trip position.
Unique two-position trip. Helps to eliminate nuisance callbacks, breaker trips to “OFF,” homeowner simply turns to “ON,” no reset required.
Plated steel latch lever provides load force for quick and reliable tripping during a thermal or magnetic trip condition.
Latch spring provides consistent relatching operation of the breaker trip mechanism.
Heavy-duty over-center toggle spring to ensure a quick and reliable “make-break” action.
Tin-plated copper contact stabs for good conductivity and quick installations.
Contact clip springfor solid bus stab connection. Eliminates expansion during envi-ronmental changes.
Large silver tungsten contacts for good contact wear and conductivity.
Magnetic armature place-ment spring ensures con-sistent low instantaneous trip on 15 and 30 ampere breakers.
Calibrated one-piece bimetal for reliable thermal protection.
Magnetic armature – assists in the instanta-neous tripping for short circuit protection.
Glass polyester base and cover for superior con-struction and durability. One-piece molded base allows for repeatable quality every time.
Heavy duty tin-plated copper box lugs for load termination. Rated for two 60/75 °C wire conductors.
Calibration screw (under UL label) provides for accurate and predictable protection every time. Factory calibrated.
Zinc-plated magnetic pole piece – works with magnetic armature to provide instantaneous tripping for short circuit protection.
Large gas port allowing short circuit gases to safely exit the circuit breaker.
All internal metal components are plated to provide a 100% non-corrosive circuit breaker.
CH Breaker Section View
Page 7
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE CHCIRCUITBREAKERSPlug-On Circuit BreakersSpecial Application Plug-On Circuit BreakersType CH Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AICAmpereRating
Wire Size RangeCu/Al60ºC or 75°C
1-Pole 120/240V AC
Requires One 3/4-inch (19.1 mm)Space
2-Pole 120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
3-Pole 240V ACCommon TripRequires Three 3/4-inch (19.1 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC 10,000 AIC
Catalog Number Catalog Number Catalog Number
10 15 20 25 30
(1) #14 – 8 1(2) #14 – 10 12(1) #14 – 6 3
CH110CH115 45CH120 45CH125 5CH130 5
CH210CH215 5CH220 5CH225 5CH230 5
CH310CH315 5CH320 5CH325 5CH330 5
35 #14 – 2 1#14 – 6 3
CH135 5 CH235 5 CH335
40 45 50 60 70 80 90100110125150
#10 – 1/0 6#14 – 2 7#3/0 8
CH140 5CH145 5CH150 5CH160 5CH170——————
CH240 5CH245 5CH250 5CH260 5CH270CH280CH290CH2100CH2110CH2125CH2150 9
CH340 5CH345 5CH350 5CH360 5CH370CH3080CH3090CH3100———
CH Neutral Switching Breakers — 10,000 Amperes Interrupting Capacity — 120 or 120/240V ACType CH Neutral Switching Breakers, 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AICUsed to open the neutral along power line(s) for applications of gas pumps.
1 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space. 2 Switching duty rated.
AmpereRating
Wire SizeRangeCu/Al60ºC or 75°C
2-Pole120V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
3-Pole120/240V ACCommon TripRequires Three 3/4-inch (19.1 mm) Spaces
1 per Individual Carton 1 per Individual Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
1520304050
#14 – 8 CH215SW 1CH220SW 1CH230SW 1CH240SW 1CH250SW 1
CH315SW 2CH320SW 2CH330SW 2CH340SW 2CH350SW 2
Neutral InNeutral Out(Hot leg)
Neutral InNeutral OutPhasePhase
CH-HID Circuit Breakers — 10,000 Amperes Interrupting Capacity — 120, 120/240 or 240V ACType CH-HID Circuit Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AICSuitable for use in circuits for fluorescent and High Intensity Discharge lighting. Also suitable for HACR applications.
1 CH215HID is rated for 120/240V.
AmpereRating
Wire SizeRangeCu/Al60ºC or75°C
1-Pole120/240V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
3-Pole240V ACCommon TripRequires Three 3/4-inch (19.1 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC 10,000 AIC
Catalog Number Catalog Number Catalog Number
152030
#14 – 8 CH115HIDCH120HIDCH130HID
CH215HID 1CH220HIDCH230HID
CH315HIDCH320HIDCH330HID
1 For 1- and 2-pole breakers.2 Solid and stranded wire can be used together.3 For 3-pole breakers.4 Switching duty rated.5 HACR rated.6 1-pole 60 – 70 amperes, 2-pole 80 – 125
amperes, 3-pole 40 – 100 amperes.7 1-pole 40 – 50 amperes, 2-pole 40 – 70
amperes.8 2-pole 150 amperes.9 CH2150 requires 4-pole spaces and is
not suitable for use on 3-phase panels, not CSA certified.
Plug-on Circuit Breakers
Plug-On Circuit Breakers, Type CH10,000 Amperes Interrupting Capacity 120, 120/240 or 240V AC
Page 8
TYPE CH
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
Special Application Plug-On Circuit Breakers
Plug-On Ground Fault Circuit Breakers, Type CH 10,000 Amperes Interrupting Capacity 120 or 120/240V AC
Ground Fault Application NotesSingle-pole Type CHGFIs are designed for use in 2-wire, 120V AC circuits. Figure 4 shows a typical wiring configuration.
Two-pole Type CHGFIs are designed for use in 3-wire, 120/240V AC circuits, 120V AC multiwire circuits employing common, neutral and 2-wire, 240V AC circuits obtained from a 120/240V AC source.
Figure 5 and Figure 6 illustrate typical wiring configurations for 120/240V AC multiwire circuits.
Figure 7 depicts a 240V AC, 2-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120V AC power source to the ground fault sensing circuit.
The figures are shown with a 120/240V AC, single-phase, 3-wire power source, but are also applicable to a 120/208V AC, 3-phase, 4-wire power supply. For all figures the electrical operation of the Type CHGFI is not affected by the equipment ground.
Type CH 1-Pole Type CH 2-Pole
Type CH Ground Fault Circuit Breakers (5 Milliampere)3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
1 60 ampere breaker listed for 75°C Cu wire only.
Type CH Ground Fault Equipment Protection Circuit Breakers (30 Milliampere)3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
1 60 ampere breaker listed for 75°C Cu wire only.
Figure 4. 1-Pole
Figure 5. 2-Pole
AmpereRating
Wire SizeRangeCu/Al60ºC or75°CAWG
1-Pole120V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
1 per Shelf Carton 1 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
152025303540455060
#14 – 6 1 CH115GFCH120GFCH125GFCH130GF—————
CH215GFCH220GFCH225GFCH230GFCH235GFCH240GFCH245GFCH250GFCH260GF
AmpereRating
WireSizeRangeCu/Al60ºC or75°CAWG
1-Pole120V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
1 per Shelf Carton 1 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
15202530405060
#14 – 6 1 CH115EPDCH120EPDCH125EPDCH130EPD———
CH215EPDCH220EPD—CH230EPDCH240EPDCH250EPDCH260EPD
Figure 6. 2-Pole
Figure 7. 2-Pole
Page 9
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE CHCIRCUITBREAKERSSpecial Application Plug-On Circuit Breakers
Plug-On Arc Fault Circuit Breakers, Type CH 10,000 Amperes Interrupting Capacity 120 or 120/240V AC
Type CH 1- and 2-PoleAFCI Circuit Breakers
Type CH FIRE-GUARD™ AFCI Circuit Breakers3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
1 Common trip refers to 2-pole 240V load application sourced by 120/240V AC (see Figure 10).2 Independent trip refers to 2-pole shared neutral circuits (see Figure 9 and Figure 11).
Figure 8. 1-Pole Single 120V Load Application Sourced by 120/240V AC
Figure 9. 1-Pole Shared Neutral with Multi-Duplex Receptacle Application
Poles AmpereRating
Configuration Catalog Number
Wire Size Range Cu/Al60ºC or 75ºC AWG
1-Pole10 kAIC
15 AFCI AFCI with GFCI
CH115AFCH115AFGF
#14 – 6
20 AFCI AFCI with GFCI
CH120AFCH120AFGF
#14 – 6
2-Pole10 kAIC 12
15 AFCI Common TripAFCI Independent TripAFCI Common Trip with GFCI
CH215AFCH215AFITCH215AFGF
#14 – 6
20 AFCI Common TripAFCI Independent TripAFCI Common Trip with GFCI
CH220AFCH220AFITCH220AFGF
#14 – 6
N A B
120/240V ACSource
120VDuplexReceptacle
1 Pole
Line B
Neutral
Neutral
Equipment Ground
N A B
120/240V ACSource
2-120VDuplexReceptacles
2 Pole
Line B
Line A
Neutral
Neutral
Equipment Ground
Figure 10. 2-Pole 240V Load Application Sourced by 120/240V AC
Figure 11. 2-Pole Shared Neutral with Duplex Receptacle Application
Line B
N A B
120/240V ACSource
Line A 240VDuplexReceptacle
2 Pole
Neutral
Equipment Ground
N A B
120/240V ACSource
Line A
120V DuplexReceptacle(With Line SideJumper Removed)
2 Pole
Line B
Neutral
Neutral
Equipment Ground
Page 10
TYPE CH
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
Special Application Plug-On Circuit Breakers
CHP Commercial Breakers — 10,000 Amperes Interrupting Capacity120, 120/240 or 240V ACNote: CHP Breakers feature on-off and trip positions for commercial applications
Type CHP Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AICNote: CHP Breakers offer on-off and trip positions for commercial applications
1 For 1- and 2-pole breakers.2 Solid and stranded wire can be used together.3 For 3-pole breakers.4 Switching duty rated.5 HACR rated.6 1-pole 60 – 70 amperes, 2-pole 80 – 125 amperes, 3-pole 40 – 100 amperes.7 1-pole 40 – 50 amperes, 2-pole 40 – 70 amperes.
CHP-GFCI Circuit Breakers — 10,000 Amperes Interrupting Capacity 120 or 120/240V ACNote: CHP Breakers offer on-off and trip positions for commercial applications.
Type CHP-GFCI Breakers — 5 Milliampere — 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AICNote: CHP Breakers offer on-off and trip positions for commercial applications.
AmpereRating
Wire Size RangeCu/Al60ºC or 75°CAWG
1-Pole120/240V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
3-Pole240V ACCommon TripRequires Three 3/4-inch (19.1 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC 10,000 AIC
Catalog Number Catalog Number Catalog Number
10 15 20 25 30
(1) #14 – 8 1(2) #14 – 10 12(1) #14 – 6 3
CHP110CHP115 45CHP120 45CHP125 5CHP130 5
CHP210CHP215 5CHP220 5CHP225 5CHP230 5
CHP310CHP315 5CHP320 5CHP325 5CHP330 5
35 #14 – 2 1#14 – 6 3
CHP135 5 CHP235 5 CHP335 5
40 45 50 60 70 80 90100110125
#10 – 1/0 6#14 – 2 7
CHP140 5CHP145 5CHP150 5CHP160 5CHP170—————
CHP240 5CHP245 5CHP250 5CHP260 5CHP270CHP280CHP290CHP2100CHP2110CHP2125
CHP340 5CHP345 5CHP350 5CHP360 5CHP370——CHP3100——
AmpereRating
Wire Size RangeCu/Al 60ºC or 75°CAWG
1-Pole120V ACRequires One 3/4-inch (19.1 mm) Space
1 per Individual Carton
10,000 AIC
Catalog Number
152030
#14 – 6#14 – 6#14 – 6
CHP115GFCHP120GFCHP130GF
Ground Fault Application NotesSingle-pole Type CHP-GFI breakers are designed for use in 2-wire, 120V AC circuits. Figure 12 shows a typical wiring configuration.
The figure is shown with a 120/240V AC, single-phase, 3-wire power source, but a 120/208V AC, 3-phase, 4-wire power supply is also applicable. Electrical operation of the Type CHPGFI is not affected by the equipment ground.
Figure 12. Typical 1-Pole Wiring Diagram
Page 11
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE CHCIRCUITBREAKERSSpecial Application Plug-On Circuit Breakers
CHP Neutral Switching Breakers 10,000 Amperes Interrupting Capacity 120 or 120/240V ACType CHP Neutral Switching Breakers, 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AICUsed to open the neutral along power line(s) for applications of gas pumps.
1 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space.
CH-M50 High Ambient BreakerType CH-M50 High Ambient Breakers 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
CH-HM and CHP-HM High Magnetic BreakersType CH-HM and CHP-HM High Magnetic Breakers 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
AmpereRating
WireSizeRangeCu/Al60ºC or75°CAWG
2-Pole120V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
3-Pole120/240V ACCommon TripRequires Three 3/4-inch (19.1 mm) Spaces
1 per Shelf Carton 1 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
1520
#14 – 8 CHP215SW 1CHP220SW 1
CHP315SW 1CHP320SW 1
AmpereRating
Wire Size Range Cu/Al60ºC or 75°CAWG
1-Pole120/240V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
15202530354045506070
(1) #14 – 8(2) #14 – 10
CH115M50CH120M50CH125M50CH130M50CH135M50CH140M50CH145M50CH150M50——
CH215M50CH220M50CH225M50CH230M50CH235M50CH240M50CH245M50CH250M50CH260M50CH270M50
AmpereRating
Wire Size RangeCu/Al60ºC or 75°CAWG
1-Pole120/240V AC
Requires One 3/4-inch (19.1 mm) Space
2-Pole120/240V ACCommon TripRequires Two 3/4-inch (19.1 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number Catalog Number
1520
(1) #14 – 8(2) #14 – 10
CH115HMCH120HM
CH215HMCH220HM
1520
(1) #14 – 8(2) #14 – 10
CHP115HMCHP120HM
CHP215HMCHP220HM
Neutral InNeutral Out(Hot leg)
Neutral InNeutral OutPhasePhase
Page 12
TYPE CH
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
Accessories
CHML
CHSF3125
CHSF2125
CHPL
Circuit Breaker Accessories
Main and Sub-Feed Lug Blocks
1 Must be purchased in multiples of ordering quantities indicated.2 Handle Ties: Typically used to join two similar independent single-pole breakers to form a 2-pole
noncommon trip breaker.3 Handle Lockoffs: Devices that use a padlock to lock the circuit breaker’s handle in the “On” or
“Off” position.4 Requires one additional pole space.5 Escutcheon Mounted: Device mounted semipermanently to the face of the circuit breaker and
secured by the loadcenter deadfront.6 Handle Lockdogs: Devices that are used to secure a circuit breaker’s handle in the “On” or “Off”
position. Handle Lockdogs are not padlockable devices.7 Handle Mounted: Device mounted above or below handle using spring pressure.8 Hold-Down Kits: Devices used to secure the circuit breaker to the loadcenter for back-feed main
application. See NEC Article 384-16(g).9 Add suffix indicated to end of breaker catalog number.
Description Ordering Quantity 1
Catalog Number
Handle Ties 2Handle tie bar for physically joining the handles of two adjacent 1-pole
Type CH Circuit Breakers. (Molded Plastic Handle Cover) 25 CHHT
Handle Lockoffs 34Padlockable device for locking the handle of 1-, 2-, or 3-pole
Type CH Circuit Breakers (Escutcheon Mounted) 5 Padlockable device for locking the handle of a 1-, 2- or 3-pole
Type CHGFI Circuit Breaker. (Escutcheon Mounted) 5
1
1
CHPL
CHPLGF
Handle Lockdogs 46Device used to secure handle in “On” or “Off” position for
1-pole Type CH Circuit Breakers. (Handle Mounted) 7 10 CHLO
Hold-Down Kits 8Hold-down retainer kit for 1-, 2-, 3-pole Type CH Circuit Breakers. For
6 – 24 circuit 125 ampere single- and 3-phase, 12 – 42 circuit single-phase 225 ampere and 24 – 42 circuit 3-phase 225 ampere MLO Type CH Loadcenters. 1 CH125RB
Hold-Down Kits 8Hold-down retainer kit for 1-, 2-, 3-pole Type CH Circuit Breakers
for 2 through 4 circuit MLO CH Loadcenters. 1 CH125RB24
Mechanical InterlockType CH for 2-, 3- and 4-pole Breakers 10 CHML
Shunt Trip for CH120V AC 1 ST 9
Number of Poles
Ampere Rating
Number of 3/4-inch (19.1 mm)Spaces Needed
Wire Size RangeCu/Al 60ºC or 75ºCAWG
Ordering Quantity
Catalog Number
23
125125
23
#1/0#1/0
1 1
CHSF2125CHSF3125
CHHT
CHPLGF
CHLO
CH125RB
TYPE CH ASSEMBLIESPage 13
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
70 AMP 2 SPACES 2 SINGLE POLES
Single-Phase Single-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
DIAGRAM 1
CH9MB270
125 AMP 2 SPACES 2 SINGLE POLESDIAGRAM 2
CH2L125INT
2.000(50.80)
2.250(57.15)
3.563(90.50)
2.688(68.28)
1.063(26.99)
Wire Range:(1) 2/0 - 14 AWG (Al/Cu)
.598(15.19)
MaximumHandleHeight
2.844(72.24)
.625(15.88)
.156 Diameter Nib .031 x 45° Chamfer
1 Nib Required
1.812(46.02)
4.588(116.54)
1.782(45.26)
.183(4.65)
3.700(93.98)
3.000(76.2)
#10 MountingScrews
.297(7.54)
.156(3.96)
.188(4.78)
1.680(42.67)
1.500(38.10)
0.750(19.05)
0.937(23.80)
#8 - #2 AWG (Al/Cu)
0.685(17.40)
0.500(12.70)
3.805(96.65)
3.087(78.41)
3.850(97.79)
2.190(55.63)
1.410(35.81)
.188(4.78)
0.200 ± 0.005 Diameter(5.08 ± 0.13)
0.200 ± 0.005 Diameter(5.08 ± 0.13)
MaximumHandleHeight
Dimensions – Inches (mm)
Legend
TYPE CH ASSEMBLIES
Dimensions – Inches (mm)
Legend
Page 14
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
125 AMP 4 SPACES 4 SINGLE POLESDIAGRAM 3 DIAGRAM 4
125 AMP 8 SPACES 8 SINGLE POLES
CH4L125INT
CH8L125INT
1.063(26.99)
2.250(57.15)
2.844(72.24)
1.625(41.28)
.156 Diameter Nib .031 x 45° Chamfer
1 Nib Required
1.182(30.02)
2.000(50.80)
3.563(90.50)
Wire Range:(1) 2/0 - 14 AWG (Al/Cu)
#10 MountingScrews
2.688(67.28)
4.666(118.52)
3.311(84.10)
.781(19.84)
2.041(51.84)
6.332(160.83)
MaximumHandleHeight
.183(4.65)
.188(4.78)
.203 Diameter(5.16)
.250(6.35)
.169 Diameter(4.29)
.169 Diameter(4.29)
5.56(141.22)
5.00(127.00)
MaximumHandleHeight
3.125(79.38)
1.439(36.55)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.172(55.17)
.203 Diameter(5.16)
.750(19.05)
.780(19.81)
.780(19.81)
6.00 (152.40)
3.125(79.38)
Wire Range:(1) 4/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.52(38.61)
3.125(79.38)
TYPE CH ASSEMBLIESPage 15
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
125 AMP 12 SPACES 12 SINGLE POLESDIAGRAM 5
125 AMP 16 SPACES 16 SINGLE POLESDIAGRAM 6
CH12L125INT
CH16L125INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
9.250(234.95)
8.400(213.36)
MaximumHandleHeight
3.256(82.70)
1.439(36.55)
3.961(100.61)
3.324(84.43)
.188 (4.78)
2.172(55.17)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:2/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.610(40.90)
C Lbreaker
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
7.750(196.85)
7.000(177.80)
MaximumHandleHeight
3.125(79.38)
1.439(36.55)
3.961(100.61)
3.324(84.43)
.188 (4.78)
2.172(55.17)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:2/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.610(40.90)
C Lbreaker
TYPE CH ASSEMBLIES
Dimensions – Inches (mm)
Legend
Page 16
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
200 AMP 12 SPACES 12 SINGLE POLESDIAGRAM 7
200 AMP 16 SPACES 16 SINGLE POLESDIAGRAM 8
CH12L200INT CH16L200INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
13.625(346.08)
12.875(327.03)
MaximumHandleHeight
3.124(79.35)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
C Lbreaker
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
13.625(346.08)
12.875(327.03)
MaximumHandleHeight
3.124(79.35)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
C Lbreaker
TYPE CH ASSEMBLIESPage 17
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
225 AMP 24 SPACES 24 SINGLE POLESDIAGRAM 9
225 AMP 32 SPACES 32 SINGLE POLESDIAGRAM 10
CH24L225INT
CH32L225INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
13.625(346.08)
12.875(327.03)
MaximumHandleHeight
3.124(79.35)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
.218 Diameter(5.54)
.310(7.87)
MaximumHandleHeight
3.124(79.35)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
.218 (5.54)
15.875(403.23)
15.025(381.64)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
TYPE CH ASSEMBLIES
Dimensions – Inches (mm)
Legend
Page 18
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
225 AMP 42 SPACES 42 SINGLE POLESDIAGRAM 11
CH42L225INT
.218 (5.54)
19.625(498.48)
18.875(479.43)
.218 Diameter(5.54)
.310(7.87)
MaximumHandleHeight
3.125(79.38)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
TYPE CH ASSEMBLIESPage 19
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
125 AMP 12 SPACES 12 SINGLE POLESDIAGRAM 12
Three-Phase Double-Row Breaker Mounting – Copper Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
125 AMP 18 SPACES 18 SINGLE POLESDIAGRAM 13
CH12L3125INT
CH18L3125INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
7.750(196.85)
7.000(177.80)
MaximumHandleHeight
Wire Range:2/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.685(42.80)
1.440(36.58)
1.440(36.58)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.172(55.17)
.750(19.05)
6.249 (158.72)
3.125(79.38)
1.610(40.90)
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
10.750(273.05)
10.000(254.00)
MaximumHandleHeight
1.685(42.80)
1.440(36.58)
1.440(36.58)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.172(55.17)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:2/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.610(40.90)
TYPE CH ASSEMBLIES
Dimensions – Inches (mm)
Legend
Page 20
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Three-Phase Double-Row Breaker Mounting – Copper Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
125 AMP 24 SPACES 24 SINGLE POLESDIAGRAM 14
225 AMP 24 SPACES 24 SINGLE POLESDIAGRAM 15
CH24L3225INT
CH24L3125INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
12.250(311.15)
11.500(292.10)
MaximumHandleHeight
1.685(42.80)
1.440(36.58)
1.440(36.58)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.172(55.17)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:2/0 - #6 AWG (Al/Cu)Torque Wire Screws*
1.610(40.90)
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
13.625(346.08)
12.875(327.03)
MaximumHandleHeight
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
1.674(42.52)
1.451(36.86)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
2.010(51.05)
TYPE CH ASSEMBLIESPage 21
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
225 AMP 30 SPACES 30 SINGLE POLESDIAGRAM 16
225 AMP 42 SPACES 42 SINGLE POLESDIAGRAM 17
Three-Phase Double-Row Breaker Mounting – Copper Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
CH30L3225INT
CH42L3225INT
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
15.875(403.23)
15.025(381.64)
MaximumHandleHeight
1.687(42.85)
1.438(36.53)
1.438(36.53)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lbreaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
.218 Diameter(5.54)
.218 (5.54)
.310(7.87)
19.625(498.48)
18.875(479.43)
MaximumHandleHeight
1.674(42.52)
1.451(36.86)
1.451(36.86)
3.961(100.61)
3.324(84.43)
.188 (4.78)
C Lof breaker
2.797(71.04)
.750(19.05)
6.249 (158.72)
3.125(79.38)
Wire Range:(1) 300 kcmil - #4 AWG (Al/Cu) Torque Wire Screws: 225 lb-in
2.010(51.05)
TYPE BR ASSEMBLIESPage 22
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OEM Loadcenter Interior Assemblies
Catalog Numbering System
Bulk Pack / C Indicates Copper BusAmpere RatingSingle-Phase: Blank / Three-Phase: 3
Maximum SpacesMaximum Single PolesInterior
12 24 INT 3 125 B
70 2 4 E8741 (1) #8–#2 AWG Cu/Al 20 24INT70B 18 32
125 2 4 E8741 (1) 1/0–#14 AWG Cu 20 24INT125B 19 32 2/0–12 AWG Al
125 6 12 E52977 (1) 2/0–#14 AWG Cu/Al 20 612INT125SRB 20 33
Single-Phase Single-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire 125 4 8 E8741 (1) 2/0–#14 AWG Cu/Al 20 48INT125B 21 34
125 6 12 E8741 (1) 2/0–#14 AWG Cu/Al 20 612INT125B 22 34
125 8 16 E8741 (1) 2/0–#14 AWG Cu/Al 20 816INT125B 23 35
125 12 12 E52977 (1) 2/0–#14 AWG Cu/Al 20 1212INT125B 24 35
125 12 24 E52977 (1) 2/0–#14 AWG Cu/Al 20 1224INT125B 25 36
125 16 24 E52977 (1) 2/0–#14 AWG Cu/Al 20 1624INT125B 26 36
125 20 24 E52977 (1) 2/0–#14 AWG Cu/Al 10 2024INT125B 27 37
125 24 24 E52977 (1) 2/0–#14 AWG Cu/Al 10 2424INT125B 28 37
200 8 16 E52977 (1) 300 kcmil –#1 AWG Cu/Al 20 816INT200B 29 38
200 12 24 E52977 (1) 300 kcmil –#1 AWG Cu/Al 20 1224INT200B 30 38
200 30 40 E52977 (1) 300 kcmil –#1 AWG Cu/Al 10 3040INT200B 31 39
225 42 42 E52977 (1) 300 kcmil –#1 AWG Cu/Al 10 4242INT225B 32 39
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire 125 8 16 E52977 (1) 2/0–#14 AWG Cu/Al 20 816INT125BC 33 40
125 12 12 E52977 (1) 2/0–#14 AWG Cu/Al 20 1212INT125BC 34 40
200 12 24 E52977 (1) 300 kcmil –#1 AWG Cu/Al 20 1224INT200BC 35 41
Three-Phase Double-Row Breaker Mounting – Aluminum Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta 125 12 24 E52977 (1) 2/0–#8 AWG Cu/Al 10 1224INT3125B 36 42
150 18 36 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 1836INT3150B 37 42
150 24 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 2442INT3150B 38 43
200 30 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 3042INT3200B 39 43
225 42 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 4242INT3225B 40 44
Three-Phase Double-Row Breaker Mounting – Copper Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta 125 12 24 E52977 (1) 2/0–#8 AWG Cu/Al 10 1224INT3125BC 41 45
200 12 24 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 1224INT3200BC 42 45
Ampere Maximum Number UL Main Terminal Wire Size Range Standard Catalog Diagram ReferenceRating 1-Inch (24.5 mm) File (Per Phase) Package Number Spaces Single Poles Reference Cu/Al 60°C or 75°C Quantity Number Page
Type BR Loadcenter Interior Assemblies
TYPE BR ASSEMBLIESPage 23
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Loadcenter Accessories
B
A .269(6.83)
.844(21.44)
2.360(59.94)
CL of Mounting Hole CL of Mounting Hole
1.187(30.15)
1.182(30.02)
B
A
2.000(50.80)
.156(3.96)
.688(17.47)
CLof
MountingHole
.269(6.83)
.344(8.74)
.844(21.44)
2.360(59.94)
1.750(44.45)
2.860(72.64)
.250(6.35)
.182 Diameter(4.62)
.120(3.05)
1.750(44.45)
.750(19.05)
.344(8.74)
CL of Mounting Hole
B
A
Figure 13
Figure 15
Figure 14
Add-on Lugs for Neutral Assemblies
Ground Bar Kits
1 Must be purchased in multiples of ordering quantities indicated.2 Distance between mounting holes is 1-3/4 inches (44.5 mm).3 For 1- and 3-phase 400 and 600 ampere applications.4 Distance between mounting holes is 2-11/32 inches (59.5 mm).
Description Wire Size RangeCu/Al 60°C or 75°C
OrderingQuantity 1
CatalogNumber
Neutral/Ground LugAdd-On Neutral or Ground Lug
#2/0 Maximum#3/0 Maximum300 kcmil Maximum
111
NL20NL30NL300
Description(See Legend)
LengthInches (mm)
OrderingQuantity 1
CatalogNumber
dssssds
dssssdsj
dssssdssssss
dssssdssssssj
dssssdssssssssss
dssssdssssssssssj
dssssdsssssssssssssssss
dssssdsssssssssssssssssj
ofodofooofodofooofo
2.54 (64.5)3.59 (91.2)4.29 (109.0)5.34 (135.6)4.61 (117.1)5.69 (144.5)6.74 (171.2)8.14 (206.8)9.19 (233.4)5.78 (146.8)
1111111111
GBK5 2GBK520 2GBK10 2GBK1020 2GBK13 2GBK14 2GBK1420 2GBK21 2GBK2120 2BRGBK39512 34
f d f f f k f d f k f f f Ground Bar Legends
j
o
d
(3) #14 – #10 Cu/Al or (1) #14 – #4 Cu/Al(1) #6 – 2/0 Cu/Al(1) #14 – #6 Cu/Al or (2) #14 – #12 Cu/Al(1) 1/0 – 14 or (3) #10 – 12 Cu/Al(1) #14 – 1/0 Cu/Al or (3) #14 – #10 Cu/Al(1) #6 – 14 Cu/Al or (2) #1/0 – 14 Cu/AlMounting Hole
f
f
GBK14
BRGBK39512
k
Neutral AssembliesAmpere UL Main Incoming Terminal Number of Terminals Standard Catalog Dimensions – Inches (mm)Rating File Wire Size Range Package Number
Reference 60°C or 75°C Quantity
125 E52977 #6–1/0 AWG Cu 10 – 20 10NEU125B 13 5.938 (150.83) 5.400 (137.16)#6–2/0 AWG Al
125 E52977 #6–1/0 AWG Cu 17 – 20 17NEU125B 13 8.388 (213.06) 7.850 (199.40)#6–2/0 AWG Al
125 E52977 #6–1/0 AWG Cu 20 – 20 20NEU125B 13 9.438 (239.73) 8.900 (226.06)#6–2/0 AWG Al
225 E52977 #1–300 kcmil Cu/Al 24 1 20 24NEU225B 14 10.913 (277.19) 10.300 (261.62)
225 E52977 #1–300 kcmil Cu/Al 35 1 20 35NEU225B 14 15.813 (401.65) 15.200 (386.08)
125 — — 4 2 1 BINA 15 2.266 (57.56) 0.594 (15.09)
#14–4 AWG #6–1/0 AWG Cu Figure Overall Length MountingCu/Al #6–2/0 AWG Al A B
Page 24
TYPE BR
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
BR Circuit BreakersCutler-Hammer Type BR plug-onbreakers in the standard 1-inch(25.4 mm) per pole package haveunique color-coded cases that indicateUL listed 10 kA or 22 kA interruptingratings and can be used as main orbranch disconnect devices. All are typeI.C. (interchangeable) devices; severalratings are SWD and HACR approved.Typical ampacity range for BRbreakers is 15 to 150 amperes.
GFCB® People Protection BreakersCutler-Hammer Type GFCBs (groundfault circuit breakers) combine state-of-the-art electronic technology with acircuit breaker mechanism in acompact 1-inch (25.4 mm) per polepackage. The GFCB automaticallysenses hot wire-to-ground faults in a4 to 6 mA range and disconnects thepower, thus providing an extra marginof safety beyond that of conventionalcircuit breakers. GFCB applicationsinclude bathrooms, cellar outlets,swimming pools, outdoor branchcircuits and kitchen branch circuits.Available in UL listed 120 and 120/240Vratings. Cutler-Hammer also offersnon-UL listed GFCBs for internationalapplications as well as ground faultdevices for equipment protection.
GFEP Equipment ProtectionBreakersThe Cutler-Hammer Type GFEP device issimilar to the GFCB, except that it isdesigned to protect equipment (notpeople) against damage from arcingground faults. It is available with a 30 mAtrip level. Applications include infraredheating equipment, computer equip-ment, process control equipment, etc.
BJ Circuit BreakersAvailable in 125 through 200 ampereframes, Cutler-Hammer Type BJ plug-on breakers have 10 kA and 22 kAinterrupting ratings that can be usedas main or branch disconnect devices.Large extruded aluminum box lugs,complies with UL486B, provide cooloperation. Tripping mechanism hasthermal and magnetic protection forlong-life performance. Rupture gas issafely vented into box gutter.
BD Circuit BreakersBD plug-on breakers have the sameconstruction as Cutler-Hammer Type BR1-inch (25.4 mm) per pole devicesexcept that two poles are in a space-saving 1-inch (25.4 mm) package.
UL listed interrupting rating is 10 kA.Some ratings are SWD and HACRapproved. Exclusive CTL rejectionfeature allows only 42 circuits in thepanel in compliance with NEC Article384-15.
BQ Circuit BreakersQuadplex® construction of Cutler-Hammer Type BQ plug-on breakersincorporates two duplex breakersassembled together to provide variouscombinations of 2-pole and single-poledevices in a 2-inch (50.8 mm) package,and allows compliance with NEC Article240-20(b). The 2-pole combinations ofCutler-Hammer Type BQ breakers aremarked “independent trip” meaningthat each pole of a 2-pole device tripsindependently of the other, but may beactuated jointly by means of the handletie. Independent trip devices may onlybe used on 3-wire Edison circuits wherethe neutral is present.
BQC Circuit BreakersQuadplex construction of Cutler-Hammer Type BQC plug-on breakersincorporates a special internalcommon trip cam. BQC breakers areavailable in several combinations of2-pole and single-pole deviceswherein the 2-pole circuits have aninternal common trip mechanism.These breakers are labeled “commontrip” and meet all the requirements ofUL489 paragraph 9.1 requiringmultipole breakers to have commontrip. Common trip breakers arerequired on all 240V circuits wherethere is no neutral present such aswater heaters, baseboard heat, airconditioners and other motorloads.
Special Application BreakersAs the name implies, these devices aredesigned for special applications asrequired by the National Electrical Code®.
Water Heater BreakerSome watthour meters incorporaterate register switches used in conjunc-tion with off-peak rates. Water heaterbreakers do not derive their circuitfrom the loadcenter stab. The line andload side of the breaker are fed toterminals on the breaker. Except forthese terminations, the device offersnormal circuit breaker protection.
Switching Neutral BreakerPrimary application for the Cutler-Hammer switching neutral breaker isfor protection of process equipmentsuch as gas pumps that utilize flam-mable liquids. Non-automatic polebreaks the neutral power leg, minimiz-ing the danger of arc conditions.
2-Pole Breakers 120V or More-to-GroundUsed on Delta distribution systems,these Type BR breakers are applied onphase legs where voltage-to-ground isabove 120V.
Non-Automatic Molded Case SwitchIdentical to comparable circuit breakerframes with this exception: non-automatic molded case switches do nothave thermal or magnetic elements.
Arc Fault Circuit Interrupters (AFCIs)Reduce the risk of fire by detectingand interrupting electrical arcing faultswhich standard thermal magneticbreakers cannot. For more informa-tion, see page 27.
Heavy-duty mechanismspring for reliableoperation.
Hardened cradle forpositive action underfault conditions.
Non-abrasive integrallymolded pivot for quickmechanism response.
One-piece movingcontact arm for quickon/off response.
Heavy-duty line terminaland spring clip for quickload center installationand cool operation.
Silver tungsten alloycontacts.
Provision forhandle tie.
Unique one-piece heavy-duty De-ionassembly for quick arc interruption.
Black Molded Handle.
Callibrated one-piece bimetal forreliable thermaltrip function.
One-piece frameassembly fordimensional stabilityand reliable operation.
Four-rivet constructionenhances strength andstructural integrity ofbreaker case.
Common trip camassures simultaneouspole opening.
Heavy-duty multi-strandflexible copper shunt forcool operation.
UL 486B approved terminalassembly for use withcopper or aluminum wire.
Large gas port for ventingshort circuit gases safelyinto load center gutter.
One-piece moldedcase construction.
Full width slot forchannel type leadcenter hold-downs.
BR Breaker Section View
Page 25
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE BRCIRCUITBREAKERSPlug-On Circuit Breakers
Plug-On Circuit Breakers, Types BR10,000/22,000/42,000 Amperes Interrupting Capacity 120, 120/240 or 240V AC
BR120 BR215 BR320
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120, 120/240 or 240V AC, 10,000, 22,000 or 42,000 AICNote: All Type BR 1-, 2-, and 3-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.
1 1-pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add-suffix H to catalog number.
2 Switching duty rated.3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.4 For use as a branch circuit breaker in 400 and 600 ampere panels only.
AmpereRating
Wire Size RangeCu/Al60°C or 75°CAWG
1-Pole 120/240V AC Requires One 1-Inch (25.4 mm) Space
2-Pole 120/240V AC Common Trip Requires Two 1-Inch (25.4 mm) Spaces
3-Pole 240V ACCommon Trip Requires Three 1-Inch (25.4 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC 42,000 AIC 10,000 AIC 22,000 AIC
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
10 15 20 25 30
#14 – 4 BR110BR115 12BR120 12BR125BR130
—BRH115BRH120BRH125BRH130
BR210BR215 3BR220 3BR225 3BR230 3
—BRH215BRH220BRH225BRH230
—————
BR310 BR315 12BR320 12BR325 BR330
—BRH315 12BRH320 12BRH325BRH330
35 40 45 50
#14 – 4 BR135BR140—BR150
BRH135BRH140BRH145BRH150
BR235 3BR240 3BR245 3BR250 3
BRH235BRH240 3BRH245BRH250 3
————
BR335 BR340 BR345 BR350
BRH335BRH340 BRH345BRH350
55 #14 – 3 BR150 BRH155 BR255 BRH255 — BR355 BRH355
60 70 80 90100110
#4 – 1/0 BR160BR170————
BRH160BRH170————
BR260 BR270 BR280 BR290 BR2100 BR2110
BRH260 BRH270 BRH280BRH290 BRH2100 BRH2110
BRHH260 BRHH270 BRHH280 BRHH290 BRHH2100 BRHH2110
BR360 BR370 BR380 BR390 BR3100—
BRH360 BRH370 BRH380BRH390 BRH3100 —
125150
#4 – 2/0 ——
——
BR2125 BR2150 4
BRH2125 —
BRHH2125 —
——
——
Page 26
TYPE BR
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
Special Application Plug-On Circuit Breakers
Ground Fault Application NotesSingle-pole GFCBs are designed for use in 2-wire, 120V AC circuits. Figure 16 shows a typical wiring configuration.
Two-pole GFCBs are designed for use in 3-wire, 120/240V AC circuits, 120V AC multiwire circuits employing common, neutral and 2-wire, 240V AC circuits obtained from a 120/240V AC source.
Figures 17 and 18 illustrate typical wir-ing configurations for 120/240V AC multiwire circuits.
Figure 19 depicts a 240V AC, 2-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120V AC power source to the ground fault sensing circuit.
The figures are shown with a 120/240V AC, single-phase, 3-wire power source, but are also applicable to a 120/208V AC, 3-phase, 4-wire power supply. For all figures, the electrical operation of the GFCB is not affected by the equipment ground.
Type GFCB Ground Fault Circuit Breakers (5 Milliampere) 1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC, 22,000 AIC
1 Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page 31.2 For use with copper wire only.
Type GFEP Ground Fault Equipment Protectors (30 Milliampere)1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Figure 16. 1-Pole
Figure 17. 2-Pole
AmpereRating
Wire Size RangeCu/Al 60°C or 75°CAWG
1-Pole120V ACRequires One 1-Inch (25.4 mm)Space
2-Pole120/240V ACCommon TripRequires Two 1-Inch (25.4 mm) Spaces
1 per Shelf Carton 1 per Shelf Carton
10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC
CatalogNumber 1
Catalog Number
152025304050
#14 – 4 GFCB115GFCB120GFCB125GFCB130GFCB140—
GFCBH115GFCBH120GFCBH125———
GFCB215GFCB220GFCB225GFCB230GFCB240 2GFCB250 2
GFCBH215GFCBH220GFCBH225GFCBH230——
AmpereRating
Wire Size RangeCu/Al 60°C or 75°CAWG
1-Pole120V ACRequires One 1-Inch Space
2-Pole120/240V ACCommon TripRequires Two 1-Inch Spaces
1 per Shelf Carton 1 per Shelf Carton
10,000 AIC 10,000 AIC
Catalog Number
Catalog Number
152025304050
#14 – 4 GFEP115GFEP120GFEP125GFEP130——
GFEP215GFEP220GFEP225GFEP230GFEP240GFEP250
Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP10,000/22,000 Amperes Interrupting Capacity120 or 120/240V AC
Figure 18. 2-Pole
Figure 19. 2-Pole
Type GFCB 1-Pole
Type GFCB 2-Pole
Page 27
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE BRCIRCUITBREAKERSSpecial Application Plug-On Circuit Breakers
Plug-On Arc Fault Circuit Breakers, Type BR10,000 Amperes Interrupting Capacity120 or 120/240V AC
Type BR 1- and 2-PoleAFCI Circuit Breakers
Type BR FIRE-GUARD™ AFCI Circuit Breakers 1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC
1 Common trip refers to 2-pole 240V load application sourced by 120/240V AC (see Figure 22).2 Independent trip refers to 2-pole shared neutral circuits (see Figure 21 and Figure 23).
Figure 20. 1-Pole, Single 120V Load Application Sourced by 120/240V AC
Figure 21. 1-Pole Shared Neutral with Multi-Duplex Receptacle Application
Poles AmpereRating
Configuration CatalogNumber
Wire Size Range Cu/Al60ºC or 75ºC AWG
1-Pole10 kAIC
15 AFCI AFCI with GFCI
BR115AFBR115AFGF
#14 – 4
20 AFCI AFCI with GFCI
BR120AFBR120AFGF
#14 – 4
2-Pole10 kAIC 12
15 AFCI Common TripAFCI Independent TripAFCI Common Trip with GFCI
BR215AFBR215AFITBR215AFGF
#14 – 4
20 AFCI Common TripAFCI Independent TripAFCI Common Trip with GFCI
BR220AFBR220AFITBR220AFGF
#14 – 4
N A B
120/240V ACSource
120VDuplexReceptacle
1 Pole
Line B
Neutral
Neutral
Equipment Ground
N A B
120/240V ACSource
2-120VDuplexReceptacles
2 Pole
Line B
Line A
Neutral
Neutral
Equipment Ground
Figure 22. 2-Pole 240V Load Application Sourced by 120/240V AC
Figure 23. 2-Pole Shared Neutral with Duplex Receptacle Application
Line B
N A B
120/240V ACSource
Line A 240VDuplexReceptacle
2 Pole
Neutral
Equipment Ground
N A B
120/240V ACSource
Line A
120V DuplexReceptacle(With Line SideJumper Removed)
2 Pole
Line B
Neutral
Neutral
Equipment Ground
Page 28
TYPE BR
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
CTL Plug-On Circuit Breakers, Type BD Duplex, BQ and BQC Quadplex10,000 Amperes Interrupting Capacity 120/240V AC
Common Trip Quadplex BreakersClass CTL, 1-Inch (25.4 mm) per Pole 120/240V AC, 10,000 AIC — All circuit breakers have rejection tab feature.
1 All Type BQC Quadplex circuit breakers carry listing for HACR applications.2 All 15 and 20 ampere single poles are switching duty rated.
Figure 24. CTL and Non-CTL Breakers
Type BQC Quadplex Common Trip Center Poles (UL Type BRD)
Wire SizeRangeCu/Al65°C or75°CAWG
Type BQC Quadplex Common Trip Center and Outer Poles (UL Type BRD)
2-Pole 1 and 1-Pole 2
2-Pole 1
Requires Two 1-Inch (25.4 mm) Spaces Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC
120V AC 120/240V AC 120V AC CatalogNumber
120/240V AC CatalogNumberAmpere Rating Ampere Rating
Outer Left1-Pole
Center 2-PolesCommon Trip
Outer Right1-Pole
Outer 2-PolesCommon Trip
Center 2-PolesCommon Trip
1515151515———
2025304050———
1515151515———
BQC2202115BQC2252115BQC2302115BQC2402115BQC2502115———
#14 – 4 1515152020202020
1520301520304050
BQC215215BQC215220BQC215230BQC220215BQC220220BQC220230BQC220240BQC220250
202020202020
152025304050
202020202020
BQC2152120BQC2202120BQC2252120BQC2302120BQC2402120BQC2502120
#14 – 4 252530303030—
253015304050—
BQC225225BQC225230BQC230215BQC230230BQC230240BQC230250—
30————
50————
20————
BQC2502030————
#14 – 4 4040405050
3040502050
BQC240230BQC240240BQC240250BQC250220BQC250250
120V AC
120V AC120/240V AC
120/240V AC
120/240V AC
NotchedBus Stab
UnnotchedBus Stab
Type BR orType BD Duplex, (CTL),Type BQ and BQC Quadplex
Type BR Notched Stab Non-CTL
Non-CircuitLimiting Type BR
Type BDDuplex
CTL CircuitLimitingFeature
RejectionTab
BQC2302115 BQC230230
Page 29
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE BRCIRCUITBREAKERS
Duplex and Independent Trip Quadplex BreakersClass CTL, 1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC — All circuit breakers have rejection tab feature.
1 All 15 and 20 ampere single poles are switching duty rated.2 All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications.
Type BD Duplex (UL Type BRD)
Wire Size RangeCu/Al 65°C or 75°CAWG
Type BQ Quadplex Independent Trip (UL Type BRD)
Type BQ Quadplex Independent Trip (UL Type BRD)
1-Pole 1 2-Pole 2 and 1-Pole 1
2-Pole
Requires One 1-Inch (25.4 mm) Space
Requires Two 1-Inch (25.4 mm) Spaces
Requires Two 1-Inch (25.4 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
AmpereRating
10,000 AIC 10,000 AIC 10,000 AIC
120V AC 120V AC 120/240V AC 120V AC CatalogNumber
120/240V AC CatalogNumberCatalog
NumberAmpere Rating Ampere Rating
Outer Left1-Pole
Center2-PolesIndependentTrip
Outer Right1-Pole
Outer2-PolesIndependentTrip
Center2-PolesIndependentTrip
10 – 1015 – 1515 – 2015 – 3020 – 1520 – 2020 – 3025 – 2530 – 1530 – 2030 – 3030 – 4030 – 5050 – 30
BD1010BD1515BD1520BD1530BD2015BD2020BD2030BD2525BD3015BD3020BD3030BD3040BD3050BD5030
#14 – 4 1520152015201520——————
2020303040405050——————
1520152015201520——————
BQ2202115BQ2202120BQ2302115BQ2302120BQ2402115BQ2402120BQ2502115BQ2502120——————
152020202025303030404050——
152030405025304050405050——
BQ215215BQ220220BQ220230BQ220240BQ220250BQ225225BQ230230BQ230240BQ230250BQ240240BQ240250BQ250250——
120/240V AC120/240V AC
120V AC
120V AC120/240V AC
120/240V AC
120/240V AC
BD2020 BQ2302115 BQ230230
Page 30
TYPE BR
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CIRCUITBREAKERS
Plug-On Circuit BreakersSpecial Application Plug-On Circuit Breakers
Plug-On Circuit Breakers, Types BJ and BJH10,000/22,000 Amperes Interrupting Capacity120/240 or 240V ACFor Use in 1-Phase and 3-Phase Loadcenters150 Amperes and Above
Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240V AC, 10,000, 22,000 AICNote: If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page 31.
1 Breaker uses two 1-Inch (25.4 mm) pole spaces on left side and two 1-Inch (25.4 mm) pole spaces on right side of loadcenter.2 Breaker uses three 1-Inch (25.4 mm) pole spaces on left side and three 1-Inch (25.4 mm) pole spaces on right side of loadcenter.
Plug-On Special Application Circuit Breakers10,000 Amperes Interrupting Capacity120, 120/240 or 240V AC
Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole, 120, 120/240 or 240V AC
AmpereRating
2-Pole120/240V ACCommon TripRequires Four 1-Inch (25.4 mm) Spaces 1
Wire SizeRangeCu/Al60°C or 75°C
3-Pole240V ACCommon TripRequires Six 1-Inch (25.4 mm) Spaces 2
10 per Shelf Carton 5 per Shelf Carton
10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
125150175200
BJ2125BJ2150BJ2175BJ2200
BJH2125BJH2150BJH2175BJH2200
#2 AWG – 300 kcmil
BJ3125BJ3150BJ3175BJ3200
BJH3125BJH3150BJH3175BJH3200
Water Heater Breakers Switching Neutral Breakers Wire SizeRangeCu/Al60°C or 75°CAWG
240V Breakers Non-Automatic Molded Case Switches
2-Pole120/240V ACCommon TripRequires Two 1-Inch (25.4 mm) Spaces
2-Pole120V ACCommon TripRequires Two 1-Inch (25.4 mm) Spaces
2-Pole240V ACCommon TripRequires Two 1-Inch (25.4 mm) Spaces
2-Pole240V AC
Requires Two 1-Inch (25.4 mm) Spaces
With Isolated Line Terminals for Separately Metered Water Heaters
With Switching Neutral Pole for Gasoline Pump Applications
Where Voltage toGround is 240V AC
For Use as Disconnect Contains No Magnetic or Thermal Trip Properties
5 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10,000 AIC 10,000 AIC 10,000 AIC 5,000 AIC
AmpereRating
CatalogNumber
AmpereRating
CatalogNumber
AmpereRating
CatalogNumber
AmpereRating
CatalogNumber
152030———————
BRWH215BRWH220BRWH230———————
15202530——————
BRSN215BRSN220BRSN225BRSN230——————
#14 – 4 10 15 20 25 30 35 40 45 50 55
BR210HBR215HBR220HBR225HBR230HBR235HBR240HBR245HBR250HBR255H
————————
50—
————————BR250NA—
—————
—————
—————
—————
#4 – 1/0 60 70 80 90100
BR260HBR270HBR280HBR290HBR2100H
60———100
BR260NA———BR2100NA
LINE
LOADOUTIN
NEUTRAL
Type BJ
BRWH215Water Heater Breaker
BRSN220Switching Neutral Breaker
Page 31
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE BRCIRCUITBREAKERSAccessories
Circuit Breaker Accessories
FIeld Installation Kits and Parts
1 Must be purchased in multiples of ordering quantities indicated.2 Handle Ties: Typically used to join two similar independent single-pole breakers to form a 2-pole noncommon trip breaker.3 Handle Lockoffs: Devices that use a padlock to lock the circuit breaker’s handle in the “On” or “Off” position.4 Escutcheon Mounted: Device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.5 Handle Mounted: Device mounted directly to the handle by the use of a set screw.6 Handle Lockdogs: Devices that are used to secure a circuit breaker’s handle in the “On” or “Off” position. Handle Lockdogs are not padlockable devices.7 Hold-Down Kits: Devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384-16(g).8 Add suffix indicated to end of breaker catalog number.
Description OrderingQuantity 1
CatalogNumber
Handle Ties 2Handle tie bar for physically joining the handles of two adjacent 1-pole
Type BR Circuit Breakers. (Metal Cylinder Pin Type)Handle tie bar for joining two independent outside poles of Types BQ and
BQC Quadplex and outside poles of two Type BD Duplex Circuit Breakers.Handle tie bar for joining two adjacent outside poles of Types BQ and BQC
Quadplex and outside poles of two Type BD Duplex Circuit Breakers.
10
10
10
BHT
THOW
THS1
Handle Lockoffs 3Padlockable device for locking the handle of 1-, 2-, or 3-pole Type BR
Circuit Breakers and 1-pole of a Type BD Duplex or one independent outside pole of a Type BQ or BQC Quadplex Circuit Breaker. (Escutcheon Mounted) 4
Padlockable device for locking the handle of a 1-pole Type BR Circuit Breaker. (Handle Mounted) 5
Padlockable device for locking the handle of a 2- and 3-pole Type BR Circuit Breaker. (Handle Mounted) 5
Padlockable device for locking the handle of a 1-pole Type BD Duplex, BQ or BQC Quadplex Circuit Breaker. (Handle Mounted) 5
Padlockable device for locking the handle of the two center poles and the two outer poles of a 2-pole Type BQ and BQC of Type BQ and BQC Quadplex Circuit Breakers. (Escutcheon Mounted) 4
10
10
10
10
10
BRLW
BRLW1
BRLW2
BRDL1
BRQLW
Handle Lockdogs 6Device used to secure handle in “On” or “Off” position for 1-, 2-, or 3-pole Type
BR Circuit Breakers and 1-pole of Type BD Duplex and one independent outside pole of Type BQ or BQC Quadplex Circuit Breakers. (Escutcheon Mounted) 4
Device used to secure handle in “On” or “Off” position for 1-pole Type BR Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for 2- and 3-poleType BR Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for 1-pole Type GFCB Ground Fault Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for one independent outside pole of Types BQ and BQC Quadplex or 1-pole Type BD Duplex Circuit Breakers. (Handle Mounted) 5
10
10
10
10
10
BHLW
BHLW1
BHLW2
BHGW
HLW1
Hold-Down Kits 7Hold-down screw kit for 2-pole Type BR Circuit Breakers in 1-phase MLO
Loadcenters through 125 amperes.Hold-down screw kit for 2-pole Type BR Circuit Breakers in MLO Loadcenters 150
through 225 amperes (1-phase only).Hold-down screw kit for 2-pole Types BJ and BJH Circuit Breakers in MLO
Loadcenters 125 through 225 amperes.Hold-down screw kit for 3-pole Types BJ and BJH Circuit Breakers in MLO
Loadcenters 125 through 225 amperes.
1
1
1
1
BREQS125
BRHDK125
BJHDS
BJHDS3P
Mechanical InterlocksTypes BR for 2-, 3- and 4-pole Breakers 10 BRML
Shunt Trips for BR120V 1 ST 8
Alarm Contacts for Type GFCB (1-Pole)Alarm Contact for GFCB (1-Pole)(1) N.O. and (1) N.C.
1 1
W1 8W2 8
Numberof Poles
AmpereRating
Number of 1-inch (25.4 mm)Spaces Needed
Wire Size RangeCu/Al 60°C or 75°C
OrderingQuantity1
CatalogNumber
Main and Sub-Feed Lug Blocks2 125
150225
222
#8 – 2/0 AWG#8 – 2/0 AWG#2 AWG – 300 kcmil
1 1 1
BRSF125BRSF150BRS225
3 150225
33
#8 – 2/0 AWG#2 AWG – 300 kcmil
1 1
3BRSF1503BRS225
BREQS125 BRHDK125
THS1 BHLW2
BRLW2
BRQLW
BHLW
THOW (Installed) BRML
BRSF125
3BRS225
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 32
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Single-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
70 AMP 2 SPACES 4 SINGLE POLESDIAGRAM 18
125 AMP 2 SPACES 4 SINGLE POLESDIAGRAM 19
24INT70B
24INT125B
2.000(50.80)
2.250(57.15)
1.063(26.99)
3.563(90.50)
2.688(68.28)
.703(17.86)
#10 MountingScrews
1.063(26.99)
#2/0 to 12 AWG (Al)
.625(15.88)
MaximumHandleHeight
3.545(90.04)
3.000(76.20)
.187(4.75)
1.625(41.28)
.297(7.54).625
(15.88).156(3.96)
.156 Diameter Nib .031 x 45° Chamfer
1 Nib Required
1.782(45.26)
.183(4.65)
4.359(110.72)
1.812(46.02)
2.000(50.80)
2.250(57.15)
1.063(26.99)
3.563(90.50)
2.688(68.28)
1.782(45.26)
1.812(30.02)
4.359(110.72)
.703(17.86)
#10 MountingScrews
1.063(27.00)
#14 - 2 AWG (Al/Cu)
.625(15.88)
MaximumHandleHeight
3.345(84.96)
3.000(76.2)
.156(3.96)
.187(4.75)
.156 Diameter Nib .031 x 45° Chamfer
1 Nib Required
1.625(41.28)
.297(7.54).625
(15.88)
TYPE BR ASSEMBLIESPage 33
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Single-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
125 AMP 6 SPACES 12 SINGLE POLESDIAGRAM 20
612INT125SRB
.218 (5.54)
9.250(235.00)
8.500(215.90)
.310(7.87)
2.388(60.66)
1.000(25.40)
4.152(105.46)
2.868(72.85)
MaximumHandleHeight
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - 14 AWG (Al/Cu)
.187 (4.75)
( )
2.146(54.51)
1.795(45.59)
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 34
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
125 AMP 4 SPACES 8 SINGLE POLESDIAGRAM 21
48INT125B
125 AMP 6 SPACES 12 SINGLE POLESDIAGRAM 22
612INT125B
2.250(57.15)
1.063(26.99)
2.688(68.28)
1.812(46.02)
5.874(149.20)
.703(17.86)
1.063(26.99)
1.782(45.26)
3.545(90.04)
3.000(76.20)
.625(15.88)
MaximumHandleHeight
#10 MountingScrews
2.000(50.80)
3.563(90.50)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
XXXX(XXXX)
XXXX(XXXX)
.187(4.75)
.156 Diameter Nib .031 x 45° Chamfer
1 Nib Required
.218 (5.54)
7.249(184.12)
6.401(162.59)
.220 Diameter(5.59)
.310(7.87)
C Lbreaker
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
TYPE BR ASSEMBLIESPage 35
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
125 AMP 8 SPACES 16 SINGLE POLESDIAGRAM 23
816INT125B
125 AMP 12 SPACES 12 SINGLE POLESDIAGRAM 24
1212INT125B
.218 (5.54)
7.249(184.12)
6.401(162.59)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
.218 (5.54)
9.250(235.00)
8.500(215.90)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 36
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
125 AMP 12 SPACES 24 SINGLE POLESDIAGRAM 25
1224INT125B
125 AMP 16 SPACES 24 SINGLE POLESDIAGRAM 26
1624INT125B
.218 (5.54)
9.250(235.00)
8.500(215.90)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
.218 (5.54)
11.250(285.75)
10.500(266.70)
.220 Diameter(5.59)
.310(7.87)
2.388*(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
.187 (4.75)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
TYPE BR ASSEMBLIESPage 37
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
125 AMP 20 SPACES 24 SINGLE POLESDIAGRAM 27
2024INT125B
125 AMP 24 SPACES 24 SINGLE POLESDIAGRAM 28
2424INT125B
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
.218 (5.54)
13.250(336.55)
12.500(317.50)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
C Lbreaker
.218 (5.54)
15.250(387.35)
14.500(368.30)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 38
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
200 AMP 8 SPACES 16 SINGLE POLESDIAGRAM 29
816INT200B
200 AMP 12 SPACES 24 SINGLE POLESDIAGRAM 30
1224INT200B
.218 (5.54)
9.625(244.48)
8.875(225.43)
.220 Diameter(5.59)
.310(7.87)
2.762(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.530(38.86)
2.100(53.34)
3.655(92.84)
3.110(78.99)
.187 (4.75)
Wire Range:300 kcmil - #6 AWG (Al/Cu)
2.671(67.84)
MaximumHandleHeight
1.391(35.33)
2.954(75.03)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 300 kcmil - #6 AWG (Al/Cu)
.187 (4.75)
1.500(38.10)
C Lbreaker
MaximumHandleHeight
1.391(35.33)
2.954(75.03)
3.655(92.84)
3.110(78.99)
Wire Range:300 kcmil - #1 AWG (Al/Cu)
.187 (4.75)
.218 (5.54)
9.625(244.48)
8.875(225.43)
.220 Diameter(5.59)
.310(7.87)
2.762(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
1.500(38.10)
C Lbreaker
TYPE BR ASSEMBLIESPage 39
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus120/240V AC, 3-Wire
200 AMP 30 SPACES 40 SINGLE POLESDIAGRAM 31
3040INT200B
225 AMP 42 SPACES 42 SINGLE POLESDIAGRAM 32
4242INT225B
.218 (5.54)
25.625(650.88)
24.875(631.83)
.220 Diameter(5.59)
.310(7.87)
2.762(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.391(35.33)
2.954(75.03)
3.655(92.84)
3.110(78.99)
Wire Range:300 kcmil - #1 AWG (Al/Cu)
.187 (4.75)
1.500(38.10)
C Lbreaker
.218 (5.54)
19.625(498.48)
18.875(479.43)
.220 Diameter(5.59)
.310(7.87)
2.762(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.391(35.33)
2.954(75.03)
3.655(92.84)
3.110(78.99)
Wire Range:300 kcmil - #1 AWG (Al/Cu)
.187 (4.75)
1.500(38.10)
C Lbreaker
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 40
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
125 AMP 8 SPACES 16 SINGLE POLESDIAGRAM 33
816INT125BC
125 AMP 12 SPACES 12 SINGLE POLESDIAGRAM 34
1212INT125BC
.218 (5.54)
7.249(184.12)
6.401(162.59)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
.218 (5.54)
9.250(235.00)
8.500(215.90)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.795(45.59)
2.146(54.51)
3.655(92.84)
3.110(78.99)
Wire Range:(1) 2/0 - #14 AWG (Al/Cu)
.187 (4.75)
1.389(35.28)
C Lbreaker
TYPE BR ASSEMBLIESPage 41
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus120/240V AC, 3-Wire
200 AMP 12 SPACES 24 SINGLE POLESDIAGRAM 35
1224INT200BC
MaximumHandleHeight
1.391(35.33)
2.954(75.03)
3.655(92.84)
3.110(78.99)
Wire Range:300 kcmil - #1 AWG (Al/Cu)
.187 (4.75)
.218 (5.54)
9.625(244.48)
8.875(225.43)
.220 Diameter(5.59)
.310(7.87)
2.762(70.15)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
1.500(38.10)
C Lbreaker
TYPE BR ASSEMBLIES
Dimensions – Inches (mm) Notched Bus Stab Solid Bus Stab
Legend
Page 42
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
125 AMP 12 SPACES 24 SINGLE POLESDIAGRAM 36
1224INT3125B
Three-Phase Double-Row Breaker Mounting – Aluminum Bus208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
150 AMP 18 SPACES 36 SINGLE POLESDIAGRAM 37
1836INT3150B
2.811(71.40)
Wire Range:#8 - 2/0 AWG (Al/Cu)
.218 (5.54)
13.250(336.55)
12.500(317.50)
.220 Diameter(5.59)
.310(7.87)
2.388(60.66)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
1.612(40.94)
Unuseable Space
C Lbreaker
.218 (5.54)
13.625(346.08)
12.875(327.03)
.220 Diameter(5.59)
.310(7.87)
3.760(95.50)
1.000(25.40)
5.736 (145.69)
2.868(72.85)
MaximumHandleHeight
1.570(39.88)
1.500(38.10)
1.500(38.10)
3.655(92.84)
3.110(78.99)
W
Recommended