1. Before Installation
1.1 To install
Please follow the installation guide because the performance
can be decreased if the product is installed incorrectly.
1.2 Product package
Product Pictures Qty Use
Terminal 1ea Access Controller
Adapter 1ea
Power cord 1ea
Supplying power for
the terminal
Rear case 1ea Fastening the terminal
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
4/20
- 5 -
4ea Fastening the terminalBolt
6ea Fastening the rear
case
1ea
5ea
Connecting door cable
S/W CD 1ea
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
5/20
- 6 -
2. Installation Environment
Please keep in mind the following conditions when you install the
product. You might need to obtain the user's consent if necessary.
This product is originally designed to install indoors. If you
have to install it outdoors, however, do not expose the terminal
to direct sunlight, snow or rain.
The connection cables should not be exposed outside, and it
is highly recommended to bury them underground. If that is
impossible, you must obtain the user's consent beforeinstallation.
Power supply should begin after all connections are completed.
Do not disconnect the lines or make any additional
connections while the power is supplied.
If you install the product as an access controller at a proper
height for the users and in a near place that facilitates control
of the entrance, you can use it more efficiently.
The power requirement for the system is AC 100~240V,
50/60Hz.
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
6/20
- 7 -
3. System Configuration
3.1 Network mode
Terminals are connected by network and it can be remote
control.
Terminal
Lock
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
7/20
- 8 -
3.2 Standalone mode
One terminal is used independently. All settings such as user
registration, deletion, and access control are performed in the
terminal alone.
Figure 3.2 Terminal Block Diagram
Locking Device
Door Open S/W
Interphone
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
8/20
- 9 -
4. Installation
The overall installation procedure is as follows:
Fasten the bracket
Attach other devices except terminal(locking device, interphone,
etc.)
Connect the external cables
Fasten the terminal
4.1 Fastening the auxiliary plate
Decide where you want to install the product, and cut the
rear case as shown Figure 4.1 to make the hole for wiring.
Figure 4.1 Making the hole for wiring in the rear case
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
9/20
- 10 -
Align the bracket with the hole for wiring as shown Figure
4.2, and fasten it with 6 bolts supported in the packet.
Figure 4.2 Fastening rear case
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
10/20
- 11 -
4.2 Attaching other devices except terminal
You can attach the following devices. Refer to the specifications
of each device for more information on installation.
Locking device
Door Open button
Types of installable locking devices and specifications
Type Specifications RemarksDeadbolt input: DC12V,
1A or lower
Voltage output,
Fail Safe/Secure
Electronic
Magnetic-Lock
input: DC12V,
1A or lower
Voltage output,
Fail Safe/Secure
Electric Strike input: DC12V,
1A or lower
Voltage output,
Fail Safe/Secure
Auto Door *Maximum Switching Voltage:
220V DC,250V AC.
*Maximum Switching Current:
2A DC,AC or lower
Contact output
Fail Safe Type: UNLOCKED, Open Type on EmergencyFail Secure Type: LOCKED, Close Type on Emergency
4.3 Connecting the external cables
You should connect the following external cables.
But you don't have to install the network cables if the customer
doesn't request them.
Door control cable
Network cable
Power cable
Wiegand signal cable
RS485 cable
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
11/20
- 12 -
4.3.1 Connecting the door control cable (Main board J2)
Specifications of the cable and material
Housing Receptacle Cable
5264-06 5263PBT UL Cable, 24~28AWG
Connection Note
Pay attention to terminal numbers when connecting the cable to
the connector.
Contact output is used when installing on the auto door. So makesure to set the terminal [JP1] as OPEN. The factory default of
the terminal [JP1] is JUMPER.
Some locking devices may not have door monitoring signals.
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
12/20
- 13 -
How to connect cables by types of locking devices
Deadbolt/Strike/Electronic Magnetic-Lock
PIN
NO.Feature Fail
Safe Type
Fail
Secure
Type
Door
Monitoring
Door
Open
1 GND GND GND COMOpen
button
2 Door Open buttonOpen
button
3 Door MonitoringMonitor
(12/24V)
4 CONTACT_BVCC(12/24
V)
5 COMMON (COM)
6 CONTACT_AVCC(12/24
V)
*The Relay Boad [JP1]=>Close
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
13/20
- 14 -
Auto DoorPIN
NO.Feature Normal
Open
Normal
Close
Door
Monitoring
Door
Open
1 GND COMOpen
button
2 Door Open buttonOpen
button
3 Door MonitoringMonitor
(12/24V)
4 CONTACT_B Contact
5 COMMON Contact Contact
6 CONTACT_A Contact
*The relay board [JP1]=>Open
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
14/20
- 15 -
4.3.2 Connecting the network cable (Network board J3)
Connect network lines as follows (pay attention to PIN numbers):
SchematicHousing Cable
PIN No Feature
1 TXP
2 TXN
3 RXPRJ45, 8PIN UTP
6 RXN
4.3.3 Connecting the power cable
Connect 12V adapter to Relay Board J4.
Connect 5V adapter ro Main Board J3
4.3.4 Wiegand output (Main board J5)
Check if the external device is pull up. If it is not, connect J16 and
J17.
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
15/20
- 16 -
4.3.5 RS-485 (Main board J1)
* If the device needs a termimal resistance, connect J18.
4.3.6 Wiegand input (Main board J9)
* Wiegand input cannot be used with RF module.
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
16/20
- 17 -
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
17/20
- 18 -
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
18/20
- 19 -
Fasten the terminal
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
19/20
- 20 -
8/9/2019 Nitgen NAC 2500 PLUS Fingerprint Access Controller Terminal Installation Manual
20/20
- 21 -
5. Check After Installation
When you finish the installation of the entire system, check if it is
installed correctly before supplying power.
Check if locking device and other devices work normally as the
following order. For more information, please refer to
"NAC-2500 Terminal User Manual" and "Access Manager
User Manual ".
When power is supplied, the initial screen with NITGEN logo
will appear.
Press the menu button to choose System Option > Terminal
Mode and check if the terminal is in SO mode.
Choose User Manager from the menu and then register user
ID and fingerprint. (By default, user ID is set to 4 digits long.)
Test the devices (including locking device) attached to the
terminal by performing fingerprint authentication.
If there's no problem, delete the fingerprint you registered for
the test.
If you manage terminals via the network after installation,
proceed the following test:
Install the program on a server PC for manager registration
and initial settings.
Set the terminal mode to NL or NS from the terminal menu.
Set the network environment from the terminal menu.
Run Remote Manager to check the terminal connection and
then register it.
In the server PC, register a terminal user and check if the
authentication is performed normally.
If there's no problem, delete both server and terminal users.
Recommended