View
271
Download
6
Category
Preview:
Citation preview
© A
BB S
ubst
atio
n Au
tom
atio
n -1
-1/
14/2
005
New features ofMicroSCADA Pro
-2-
General
SYS 600
DMS 600
LIB 500
COM 500
IEC 61850
MicroSCADA Pro
-3-
Quick Overview
SYS 600 *9.0New User Interface
Process DisplaysAlarm ListEvent ListBlocking List Trends
IEC 61850 connectivityExtended language supportVarious improvements in the engineering toolsImproved integration with DMS 600
MicroSCADA Pro
-4-
Quick Overview
DMS 600 *4.0Improved network editingEvent history simulationExtensions in fault location algorithmsGPS utlisation for network editing and field crew locationNetwork status on the webOPC ClientEtc.
MicroSCADA Pro
-5-
Quick Overview
COM 500IEC 61850 supportEnhanced data importMore alarm groupsMore protocolsEtc.
LIB 500/510IEC 61850 support
MicroSCADA Pro
-6-
Introduction
MicroSCADA ProNext step in the development of MicroSCADA and Open++ OperaThe complete and harmonized product family for substation Control, Network Control and Distribution Management
Starting pointMicroSCADA 8.4.5Opera 3.3
MicroSCADA Pro
-7-
Application Areas
Distribution AutomationNetwork ControlSubstation ControlSubstation MonitoringFeeder Automation
MicroSCADA Pro
-8-
Systems
Substation MonitoringSubstation Control
Distribution Management Network ControlFeeder Automation
MicroSCADA Pro
-9-
Built in local HMI or HHHMI
High End Scadaposition
MicroSCADA
MicroSCADA
EMS
Substation HMI
SCADA
SMS 510
CAP 5xx DMS
IndicatorsProtection & Control HMI
GraphicalProtection & Control HMI
TextualProtection & Control HMI
Substation Gateway
Opera
Position
MicroSCADA Pro
MicroSCADA Pro
-10
-
Products
MicroSCADA Pro Control System SYS 600 *9.0Distribution Management System DMS 600 *4.0Communication Gateway COM 500 *4.1
MicroSCADA Pro
-11
-
Main Requirements
Network ControlNew Process Graphics
zoom, panning and de-cluttering
Substation ControlSupport for new standard IEC 61850
IEC61850 System support
MicroSCADA Pro
-12
-
Evolutionary development strategy
Upgradeability and system continuity are key factors to maintain the customers confidence in ABB’s solutions
Keeps our existing customersEnable our customers to relocate existing solutions to a more modern environment. Preserves a customer's existing solution investment and the functionality and reliability.Market message to new customers:
Safe investment when using ABB’s solution.
Leverage on installed MicroSCADA base3400 installations -- 820 SCADA-systemsLarge # of trained staff in local units.
MicroSCADA Pro
-13
-
Compatibility
SYS 600 *9.0 is fully backward compatible with current applicationsThe new user interface is an additional function that works well in parallel with the current user interface
MicroSCADA Pro
© A
BB S
ubst
atio
n Au
tom
atio
n -1
4-
1/14
/200
5
MicroSCADA ProSYS 600 *9.0
-15
-
New User Interface
Improved look & feelImproved PerformanceMore functions, flxible and modifiableNew monitor type
SYS 600
-16
-
New Process Displays
Process displaysView - Zoom Control…
zoompande-clutter
SYS 600
-17
-
New Process Displays
Zoom, Pan & DeclutteringDynamic Busbar coloringStandard symbols for electrical applicationsHundreds of other symbolsSupport for standard graphics formats and ActiveX componentsCan be connected directly to existing LIB process databaseCan be used in parallell with existing pictures
SYS 600
-18
-
New Display Builder
New symbol library for electrical applicationsHundreds of other symbolsEasy handling of own symbol librariesGeneric OPC clientExtensive generic drawing toolsFlexible configuration of dynamic behaviour (show/hide, fill, move, color, rotate, blink, scale, etc.)
SYS 600
-19
-
New Display Builder
Easy building of Single Line Diagram with Drag & Drop
Browse the database structureDrag the device to the single line diagramDone! All connections made!
Builds topology for dynamic busbar coloring automatically
SYS 600
-20
-
New Trends
All functions of current trends +Improved Zoom & PanImproved performanceImproved look & feel
SYS 600
-21
-
New Alarm Lists
Improved performanceImproved look & feelImproved customizationNew functions
FindCopy/PasteTexts in local language
SYS 600
-22
-
New Event List
Improved performanceImproved look & feelImproved customizationNew functions
FindCopy/PasteProgrammable coloringIncreased time interval (up to one year)Message TextTexts in local language
SYS 600
-23
-
New Blocking List
All functions of current blocking list +Improved performanceImproved look & feelImproved customizationNew functions
FindCopy/PasteTexts in local language
SYS 600
-24
-
Migration Tools
Event ConversionAdds new event handling to existing LIB database
Creates H-objects and links them to P-objectsBased on FORM-pictures and text files
SYS 600
-25
-
Migration Tools
DAT ExportExtracts Picture Function configuration data from existing LIB pictures to be used by new process graphics
SYS 600
-26
-
Language Support
New Event Handling Object (H)To handle event & status texts
Maps object value/state to texts
To support localisation of event & status textsText id in H-objectActual language specific text in text database
To support future OPC A&E interface
SYS 600
-27
-
Language Support
New Process Object AttributesTX - Translated Object Text
The value of the OX attribute translated into the current languageAll texts now support user specific languages – also in event and alarm list
EH - Event HandlingThe name of the event handling object associated to the process object
SX - State TextA descriptive text of the object state in the current languageRetreived through the H object
MX - Message TextA descriptive text of the event in the current languageRetreived through the H object
SYS 600
-28
-
Text Translation Tool
Support for Text databases
SYS 600
-29
-
Object Navigator
New P-object viewsBy unit number (UN)By object identification (OI)By OPC name (ON)
Support for IEC 61850 P-object typesImproved OI editor
SYS 600
-30
-
Object Navigator
Standard Function installationInstallation of LIB standard functions without picturesTo be used with new process displays
Import/ExportStart export based on the active selection
Event Handling objectsManagement of the new event handling objectsCreate, view, modify, delete
SYS 600
-31
-
Import/Export Tool
New VS Import/Export Tool
Import/Export of application objects from/to ascii fileCan also operate on selections in the object navigator
SYS 600
-32
-
Online Backup Tool
New online backup toolOnlineBackup of the main applicationManual & AutomaticUses ShadowingAdvanced programmable option
SYS 600
-33
-
Base System Object Navigator
Online handling of base system objectsViewCreate Modify
SYS 600
-34
-
System Configuration Tool
DNP data point editorGeneral ASCII (ADEMCO) Communication Line and Stations ConfigurationASCII Printer Communication Line Configuration
SYS 600
-35
-
DMS integration
Integrated user interfacePop-up menu to trace feeders, locate objects on map etc.Easy way to open single line diagrams from the network mapNetwork data from DMS available in process graphicsIntegrated login
Single data entryThe data on the single line diagrams are reusedLayout, objects and connectivity are used in DMS
HarmonizationLook and feelColorsSymbol presentation
SYS 600
© A
BB S
ubst
atio
n Au
tom
atio
n -3
6-
1/14
/200
5
MicroSCADA Pro DMS 600 *4.0(Opera technology)
-37
-
MicroSCADA Pro DMS 600 *4.0
DMS 600 *4.0 is direct successor to Open++ Opera 3.3
Existing installation can be updated directly using installation program
DMS 600 *4.0 belongs to MicroSCADA Pro product family
A standard option to any SCADA and SA systemConsistent product name (ref. SYS 600, LIB 500)Integrated and consistent ordering tool and procedures
DMS 600
-38
-
Harmonized and integrated with MicroSCADA Pro SYS 600 *9.0
Common Windows look and feel New process graphics, new list applications
User interface well integratedMicrosoft component technology (COM and OPC) used. Same technology used also to third party software integration (Microsoft Office).
MicroSCADA Pro DMS 600 *4.0DMS 600
-39
-
Changes in license structure
+ General extensionsOpera standard+ other options+ other options
DMS 600 (Base)Opera LT (light)
In DMS 600 there is one basic product and options can be selected on top of that. In Opera 3.3 additional options where available only on top of Opera standard.
New license modules (in addition to General extensions)Outage info using HTML for intra/internetOutage info using telephone answering machineOutage info using SMS messagesGPS data for field crew location and network editing
DMS 600
-40
-
Unchanged license modules
Network AnalysisExtended load modelingOperations planningReconfigurationFault locationOutage reporting and statisticsRestoration supportAutomatic fault isolation and restorationLow voltage networksExtended data management
DMS 600
-41
-
DMS 600 - SYS 600 Integration
User interface integrated (DMS 600 base)Pop-up menu to trace feeders, locate objects on map etc.Easy way to open single line diagrams from the network mapControl dialogs for switches opened directly from network mapFeeder data from DMS available in process graphics for feeding CBs and line indicators without using DMS in the user sessionIntegrated login and logoff (SYS 600 ->DMS 600)
Single data entryThe data on the single line diagrams are reusedLayout, objects and connectivity are used in DMS
HarmonizationWindows look and feelColorsSymbol presentation
DMS 600
-42
-
New requirements for DisCos
The society requires information of distribution quality
Exact information of outage situation and forecastsFor media, customers and own organization
The authorities and regulators require statistics and information
Key figures to evaluate operational quality and efficiency
New lawsIn Finland compensation for long outages to all customers
DMS 600
-43
-
Outage information in internet/intranet
Information to internal management and external parties like mediaHistory of the situation is stored to study the chosen actionsDMS 600 creates automatically
html-document for intra- and internetMS Word-documents stored for later studies
DMS 600
-44
-
Outage information using SMS messages
Automatic GSM SMS-messages when a fault occurs on a feederOpera queries from database those customers telephone numbers that are fed by the faulted feederCan be used to inform maintenance outages etc.Uses a GSM modem and modem driver installed in MicroSCADA server
DMS 600
-45
-
Outage information by telephone
Recorded messages for each feeder Messages can be generated automaticallyCalling customers can try reach a person or leave a voice message
if recorded messages do not give enough information or customer has vital information to give
The voice messages are sent as email to the operators
DMS 600
-46
-
GPS support
GPS for field crew locationCoordinates from GPS can be used in real-timeSupports WGS84 and local Map Datums
Continuous location of own position with map panning in moving vehiclesGPS coordinates used in network editing
Way-points can be stored to GPS deviceNMEA-0183 serial communication standard is used to transfer points to Opera so that network can be updated accuratelyNMEA = National Marine Electronics Association
DMS 600
-47
-
New features in DMS 600 base
Enhanced network editingCopy-pasteMoving and deleting large parts of network
Simulation of historical eventsTrace coloring remains on screen while zooming and panningFindings to show added information on network map(in parallel with existing operator notes)Print-out of several listsNew way to zoom out desired amount
DMS 600
-48
-
Other new features
Impedance-based fault distance calculation (Fault location)Setting of hour of the year (date and time) (Network analysis)Blinking symbols when object having an unacknowledged alarm in SYS 600 (Alarms in module general extensions)
DMS 600
© A
BB S
ubst
atio
n Au
tom
atio
n -4
9-
1/14
/200
5
LIB 5xx withMicroSCADA Pro
-50
-
LIBs for SYS 600 *9.0
LIB 500 *4.0LIB 510 *4.1LIB 520 *4.0.4LIB 530 *4.0.4LIB 542 *4.0.4
LIB 500 *4.0.5 for SYS 500 *8.4.5
LIB 500/510
-51
-
New features
News in 4.0.5 and 4.1 :REX 521 rev. E supportPossibility to use the Relay Setting Tool and DR-Collector Tool together with IEC101/SPA and IEC104/SPA gateways. No support for the Power Quality Monitoring tool and Event editor Tool.
LIB 500/510
-52
-
New features
News in 4.1 onlyIEC 61850 support
Pictures (generic)DB (generic)Relay setting (SPA over 61850)Disturbance recorder (SPA over 61850)
LIB 500/510
© A
BB S
ubst
atio
n Au
tom
atio
n -5
3-
1/14
/200
5
MicroSCADA Pro -communication
COM 500 *4.1
FIPTUA/SAPFIPTMV/DA
-54
-
New Features
Well known substation gateway COM500 – new revision!!Main changes since *4.0
New Base System SYS 600 9.0 IntegratedIncluding MicroSCADA Data Access OPC Server
Communication SoftwarePC-NET protocol extensions included
Signal RoutingSupport for IEC 61850 process devices2000 alarm groups now supported
ToolsUpdated tools from the SYS 600 9.0 integratedCross-Reference file converter
COM 500
-55
-
Protocol improvements (also in SYS600)DNP V3.00 Subset Level 3
Both master & slave
Faster Interrogation with SQ=1 Packing Style in IEC60870-5-101Enhanced process communication
Improved Modbus (RTU/TCP) Master for multidropImproved DNP3.0 Master for multidrop
New protocol support in SYS600IEC61850-8-1 as OPC server (see later)P214, ported from DCP-NETGeneral ASCII, ported from DCP-NETRCOM, ported from DCP-NET
New FeaturesLIB 500/510
-56
-
Miscellaneous:Increased Alarm Group count (from 255 to 2000)New Options for Trip Signal HandlingDirect IEC commands for Secured Controls in process directionMore command parameters for REC 561
New FeaturesLIB 500/510
-57
-
Following SYS 600 9.0 Tools IntegratedObject Navigator with New Functionality
Install Standard FunctionsNew Navigation Schemes
for Process Objects, Data Objectsfor Command Procedures and for Free Type Process Objects
Export and Import Application Objects
System Configuration tool with New FunctionalityNew Base System Object Navigator toolNew Online Backup tool New SCIL Database toolNew Event Conversion tool
ToolsLIB 500/510
-58
-
Cross reference file converterConvert the cross reference information from the tabular sheet file (e.g. Excel files) to .XRF formatXRF format file is then imported into Cross-References toolSupports at the moment monitoring direction cross references only
ToolsLIB 500/510
© A
BB S
ubst
atio
n Au
tom
atio
n -5
9-
1/14
/200
5
MicroSCADA Pro
IEC61850 supportFIPTUA/SAPFIPTMV/DA
-60
-
IEC61850-8-1 support
IEC61850-8-1 support in MicroSCADA ProNewest, most exciting protocol in Substation Automation supported in
SYS600 *9.0COM500 *4.1
Common implementation for all products aboveImplemented as OPC DA serverSYS600 and COM500 will use MicroSCADA OPC DA clientCET is always used as the configuration tool
IEC61850-8-1
-61
-
IEC61850-8-1 client OPC Server
IEC61850-8-1 OPC server featuresMMS protocol stack implemention
Read / Write Variable Data, Buffered / Unbuffered Reporting -> dynamically updated process imageCommandsSpecial handling for Setting Group control
XML based access using XSAT protocol
Namespace corresponding to IEC61850-7-x data modelTransparent SPA over TCP/IP for IED tool connectivity
Supported also in SPA-ZC40x and in Swiss RE.316Can be used for tool remote access – as far as TCP/IP connection is available
Protocol diagnostics published also in OPC namespaceTime synchronization: SNTP client
Support several servers for redundancyCET, Communication Engineering Tool
SCL device descriptions import for signal engineeringMandatory for IEDs supporting IEC61850
IEC61850-8-1
-62
-
IEC61850-8-1 client OPC Server
CET
IEC61850-8-1
-63
-
IEC61850-8-1 – SYS600New features for IEC61850-8-1 protocol support in SYS600/LIB500
Protocol implemented as IEC61850-8-1 client OPC serverSYS 600
Object navigatorSupport of creating LIB510 process database for generic IEC61850devices
LIB 510 *4.1Support of IEC61850 process object types in single-line-diagram picture functions
COM 500 *4.1Support of IEC61850 process object types
MicroSCADA OPC DA client *2.1A stand-alone MicroSCADA node behind TCP/IPEasier mapping between OPC namespace and process database
IEC61850-8-1
-64
-
SYS600
Ethernet / IEC61850-8-1
OPC Client
MicroSCADAACP TCP/IP
ProcessDatabase
IEC61850-8-1 OPC Server
IEC61850 and SYS600
MicroSCADA ProSYS 600 *9.0
OPC DA Client *2.1IEC61850-8-1 client OPC server
LIB 510 *4.1 or COM500 *4.1
ACP
MS
OPC
DA
clie
ntSY
S600
OPC
Se
rver
IEC61850-8-1
Recommended