Quality and Service
The B.E.G. Controls family of companies was founded in 1975, and has always stood for quality and innovation. From the beginning, our focus has been on customer satisfaction. Let our staff of lighting control experts assist you.
� Our support specialists are highly trained and available to assist you.
� Our customer care department is ready to assist you and will make sure the project meets the high standards of B.E.G. Controls pleasant and easy.
� B.E.G Controls products are German-engineered to the highest performance and reliability standards. Manufac-turing processes are certified ISO 14001 and ISO 9001 compliant.
� Our products are available exclusively through leading electrical and lighting distributors supported by a network of local manufacturer representatives.
� Our Applications Engineering group is available to assist you with the planning and specification for your next project. Sensor placement drawing services are available in PDF and CAD format.
2
ControlsB.E.G.
3
MINI – One Size Fits All
MINI from B.E.G. Controls could end up being the only occupancy sensor you’ll ever use. The industry-leading small foot print and detection area, combination of motion and daylight sensing, mounting versatility, scalable granularity, and control options for power packs makes the MINI the perfect sensor for a wide range of solutions.
... Integral Fixture or Zone control
... PIR Motion and Daylight sensing
...Switching or Dimming Control
... IP 65 / wet location
B.E.G. Controls – The lighting control professionals
... Low Bay or High Bay optics
... IR Wireless Set-up & Testing
4
Power PackAvailable in:-Switching-Switching with HVAC relay-Dimming (0-10V, 1-10V)-DALI (coming soon)
OEM Fixture Internal/External Mounting Bracket for sensor and power pack
Smartphone App with IR Adapter*
* Adapter sold separately, App download is free. Smartphone by others4
1 7/16 in. / 36 mm
1i n.25 mm
0.5 in.12m
m0.6 in.16 m
m
33 ft/10 m20 ft/6 m13 ft/4 m
33 ft/10 m 360°
8 ft/2.50 m RJ 12
MINI-P-PP-A-FC
Power supply: 24 V DC from B.E.G. Controls‘ Power Pack or from proprietary system
Power consumption: 1W
Detection area: 360°
Detection range: Ø 19 ft / 6 m across
Protection/ Polution degree: IP65 / Class IV
Operating Temperature: -13 °F to 122 °F / -25 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Remote controllable: IR-Adapter for Smartphones
0.6 in.16 m
m0.94 in.24m
m
1 7/16 in./36mm
1i n.25 mm
MINI-P-PP-A-GH-FC
Power supply: 24 V DC from B.E.G. Controls‘ Power Pack or from proprietary system
Power consumption: 1W
Detection area: 360°
Detection range: Ø 32 ft / 10m across Ø 19 ft / 6 m towards Ø 13 ft / 4 m seated
Protection/ Polution degree: IP65 / Class IV
Operating Temperature: -13 °F to 122 °F / -25 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Remote controllable: IR-Adapter for Smartphones
19 ft / 6 m32 ft / 10 m RJ
360°
19 ft / 6 m
19 ft / 6 m
11 ft / 3.5 m
11 ft / 3.5 m
ControlsB.E.G.
5
� The small footprint makes the MINI aesthetically unobtrusive and easy to mount while still delivering superior 360-degree detection coverage that is comparable to or better than full size sensors on the market.
� Passive infrared motion detection and daylight sensor in one package.
� A choice of two optics enables the MINI to be used in high or low ceiling applications.
� Designed and tested for wet and high-humidity locations. IP65 rated.
� When used with B.E.G. Controls’ Power packs, additional sensor(s) can be connected in parallel to increase to the control zone detection area.
� Spring clips allow a quick and easy installation in suspended ceilings and light fixtures.
� The available RJ-12 connector allows the sensor to plug right into the power pack making wiring quick and error-free.
� Includes clip-on blinds to fine tune the detection area.
� Sensor functions and test mode are set via Smartphone App.
� The available OEM fixture mounting bracket simplifies mounting of the MINI and a power pack internally or externally for integral sensor applications.
� 5 year limited warranty.
Application examples: Private and open offices, conference rooms, school and university classrooms, corridors, healthcare facility areas, warehouses, gymnasiums and multipurpose rooms.
MINI – One Size Fits All
5
6
PP-1-W PP-1-J PP-A-W
PP-A-J PP-DIM
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 24 V DC/4mA1 control input. Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
Switching power: max 20A @277 V AC 50/60 Hz1hp @277VAC 50/60 Hz
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 24 V DC/4mA1 control input. Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
Switching power: max 20A @277 V AC 50/60 Hz1hp @277VAC 50/60 Hz
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 2 control inputs (Motion and HVAC). Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
Switching power: max 20A @277 V AC 50/60 Hz1hp @277VAC 50/60 Hz
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 2 control inputs (Motion and HVAC). Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
Switching power: max 20A @277 V AC 50/60 Hz1hp @277VAC 50/60 Hz
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 1 control input (Motion). Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
DIM Output: 1-10V, max. 50 ECG
ControlsB.E.G.
7
� Full-featured power packs that provide power and switching control to B.E.G. low voltage occupancy sensors and photosensors.
� Suitable for parallel connection of multiple sensors. Consult product specifications of a particular sensor for the maximum number of sensors supported. Please contact B.E.G.
� Suitable for parallel interconnection
� LED status and fault indicators
� ½ inch trade size threaded nipple with two lock nuts included.
� RJ-12 sensor port. Splitter accessory available to connect multiple sensors.
� Integral short circuit and thermal protection
� 5 years limited warranty
� ROHS compliant and UL 2043 plenum rated
� Indoor applications: Warehouses Gymnasiums Private and Open Offices Conference Rooms School/University Classrooms Corridors Healthcare and Laboratory Spaces Multipurpose rooms
� Outdoor applications: Open air parking garages Under outdoor canopies Sally ports Loading docks Pole light applications Vacancy (Manual) operation is achieved by combining the PP-A-J power pack with a low voltage momentary contact switch and setting the integral mode switch to “manual”.
Power PacksPP-A-W
Power supply: 120 - 277 V 50 /60 Hz
Power output: 24 V DC/200 mA (Class II)
Control input: 2 control inputs (Motion and HVAC). Normally-open momentary contact switch or dry contact closure.
Protection/ Pollution degree: IP20 / Class III
Operating temperature: -4 °F to 122 °F / -20 °C to +50 °C
Housing: UV- and shock resistant 5VA material
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.
Switching power: max 20A @277 V AC 50/60 Hz1hp @277VAC 50/60 Hz
8
MINI – One Size Fits All
Private and Open Offices Corridors
GymnasiumOne Size Fits AllClassrooms
Warehouses
Industrial AreasClean Room AreasConference Rooms
ControlsB.E.G.
9
The MINI can easily be mounted in or on light fixtures, either at the factory or in the field. The small surface area and IP65 rating of the MINI along with the available power packs means the MINI can be integrated into almost any fixture. The available interior/exterior mounting bracket for the sensor and power pack and RJ-12 jack facilitates streamlining of fixture design and assembly. B.E.G. Controls welcomes custom product specification requests from OEM customers to find solutions that will suit their needs.
MINI – One Size Fits All
One Sensor, Many Solutions ...and many more!
The MINI can provide several solution options for virtually endless applications. The available power pack control options, choice of two optics for low or high ceiling applications, combination of PIR motion sensor and photosensor, and the ability to connect multiple sensors in parallel to a power pack to increase a zone’s detection area will give designers flexibility in granularity of control and value engineering while still satisfying project specifications and energy building codes like California Title 24, ASHRAE 90.1, and the International Energy Conservation Code (IECC). The IP65 rating and small surface area makes the MINI suitable for a number of complex environment applications where other sensors won’t perform well or last long before failing.
RJ12 splitter
The MINI offers several benefits to both the installer and end user. The RJ-12 jack connection of the sensor to the power pack saves time and prevents errors in wiring. Should an additional sensor be required in a zone after the project is installed, a simple RJ12 splitter can be added, this makes adding another sensor simple.
The wireless infrared remote control feature allows the sensor to be programmed, tested and configuration after the sensor is installed, so there is no need to worry about getting up to the sensor to change dip switches if the sequence of operation changes during the project or usage patterns of the space requires a setting change down the road. The high quality of B.E.G Controls sensors means few or no call-backs for the installer, and years of worry-free operation for the end user.
10
MINI – One Size Fits All
Secondary
Primary Secondary
Primary Secondary
Primary Secondary
Primary Secondary
Primary
Primary
Primary
Primary
Secondary Secondary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Sensor
Sensor with blinds
Power Pack
Mounting information:When used in high-bay warehouses, care should be taken that, in the cross-aisles of the warehouse, detectors are installed that can detect movement only in the desired aisle locations, by using blinds or other technical arrangements.
!
PowerPack
ControlsB.E.G.
11
Warehouse spaces offer an excellent opportunity for lighting control. Shelve aisles and traffic areas can be zoned separately from traffic areas to turn off or dim unoccupied areas, and then turn on or raise the light level when a person or vehicle enters the area. Warehouses with skylights offer additional opportunity for savings through daylight harvesting. This reduces operating costs through reducing energy consumption and increasing LED or lamp life, and compliance with national and local energy codes that require lighting control in these areas.
In the example on the left, the traffic areas are divided into five control zones. The loading dock (Zone 1) uses a single power pack to switch the lighting and the detection range is extended by connecting one MINI primary sensor and two MINI se-condary sensors. The traffic aisles are divided into two zones each (Zones 2-5), using a power pack and primary sensor in each zone so the lights will not switch on until a person or vehicle is detected by the sensor in that control zone. Each of the five shelf rack aisles are zoned separately (Zones 6-10) using a power pack each and the detection range is extended by connecting a primary and secondary sensor. Included masking shields are installed on the shelf aisle sensors sides facing the traffic aisles so that the sensors do no detect motion unless a person or vehicle actually enters the shelf aisle.
Different variations can be made to this design to suit specific needs. Dimming power packs and MINI sensors can be used in the aisles to allow the lighting to remain on at a low level instead of completely off if there are safety concerns and enable day-light harvesting. Fixtures with integral MINI sensors can be used instead of externally wired power packs and sensors to provide even more granular control and simplify installation.
Application Example – High Bay Warehouse
MINI – One Size Fits All
Product Code Part Number
MINI-P-PP-A-GH-FC 97184
MINI-S-PP-GH-FC 97187
PP-1-J 96017
For High Bay Warehouse Alternative Product Code Part Number
MINI-P-PP-DIM-GH-FC 97188
MINI-S-PP-GH-FC 97187
PP-DIM-J 97017
MINI – One Size Fits All
12
MINI – One Size Fits All
Primary Primary Primary Primary Primary
PrimaryPrimarySecondaryPrimary
Prim
ary
Seco
ndar
y
Seco
ndar
y
Primary
Secondary
Primary
Secondary
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
PowerPack
MINI – One Size Fits All
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5-11
Additional override switch
Sensor
Sensor with blinds
Power PackPowerPack
ControlsB.E.G.
13
The above example is of an office space containing a mix of private offices, open areas with cubicles, and a conference room. The reception and open cubicle areas are divided into three control zones. The reception area (Zone 1) uses a single power pack to switch the lighting and the detection range is extended by connecting one MINI primary sensor and one MINI secondary sensors. The traffic aisles and center cubicle area are divided into a second zone (Zone 2) using a single power pack, and the detection range is extended by connecting a primary and two secondary sensors. The sensors are placed where they will detect minor motion in each of the cubicles. Included masking shields are installed on the primary sensor facing the third control zone so it will not detect motion when someone is in that area. The back cubic area (Zone 3) is designed similarly to Zone 2 only using a primary and secondary sensors connected to a single power pack. Each of the private offices (Zones 5-11) use a single power pack and primary sensor to provide individually zoned occupancy sensing, as well as daylight harvesting control if the offices have windows. A low voltage momentary contact switch is wired to the power pack to provide a wall switch override. Where code requires a vacancy sensor in private offices this mode is selected via a switch on the power pack. The PP-A power pack has an auxiliary relay to signal a change in occupancy to HVAC and BMS systems. The conference room (Zone 4) adds a secondary sensor to extend minor motion detection range.
Different variations can be made to this design to suit specific needs. Dimming power packs and MINI sensors can be used for daylight harvesting, to allow the lighting to remain on at a low level instead of completely off, and to provide full range dimming via low voltage switch in private offices and conference rooms. Fixtures with integral MINI sensors can be used instead of externally wired power packs and sensors to provide even more granular control and simplify installation.
MINI – One Size Fits All
Application Example – Office Area
Product Code Part Number
MINI-P-PP-A FC 97180
MINI-S-PP-FC 97183
PP-A-J 97020
For Office Areas Alternative Product Code Part Number
MINI-P-PP-DIM-FC 97181
MINI-S-PP-FC 97183
PP-DIM-J 97017
MINI – One Size Fits All
14
MINI – One Size Fits AllMINI – One Size Fits All
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
Zone 1
Zone 2
Zone 3
Additional override switch
Sensor
Power PackPowerPack
ControlsB.E.G.
15
MINI – One Size Fits All
The above example is a conference room containing a suspended direct/indirect fixture over the conference table and recessed wall wash downlights along the perimeter. The front wall has a projection screen and the side wall has a window.
The conference room is broken up into three zones. Zone 1 is the suspended fixture over the table, Zone 2 consists of the wall washers in front and along the inside wall, and Zone 3 consists of the wall washers along the outside wall. PP-DIM power packs are used with one MINI primary sensor each. A 3-button low voltage momentary contact switch is used to override and dim each zone. The photosensor in Zone 3 will dim the fixtures along the window to satisfy daylighting code requirements. The photosensors in Zone 1 & 2 will also dim the lights in response to ambient light but less since they are further in from the window.
Variations to this design approach could be to use switching PP-A or PP-1 power packs if no dimming is desired, or if daylight harvesting is not a requirement. Another zone could be added to separate control of the front wall washers in front of the projector screen. The pendant fixture over the table could also be ordered with an integral MINI sensor.
Application Example – Conference Room
Product Code Part Number
MINI-P-PP-DIM-FC 97181
MINI-S-PP-FC 97183
PP-DIM-J 96017
For Conference Room Alternative Product Code Part Number
MINI-P-PP-A-FC 97180
MINI-S-PP-FC 97183
PP-A-J 97020
MINI – One Size Fits All
16
MINI – One Size Fits All
Secondary Primary Secondary
PowerPack
Primary
PowerPack
Zone 1
Zone 2
Additional override switch
Sensor
Power PackPowerPack
ControlsB.E.G.
17
MINI – One Size Fits All
The above example is of an L-shaped corridor with LED downlights spaced at 4’ centers at an 8’ mounting height. The corridor is split into two zones. PP-A power packs are used, with Zone 1 utilizing a primary and two secondary MINI sensors to extend the detection range down the long hall, and a single primary MINI that can cover the short leg in Zone 2. Since passive infrared (PIR) sensors require line of sight to detect motion, the MINI sensors must be placed where they can see down each leg of the corridor as someone approaches. The sensors are spaced within the “walking toward” coverage range in each direction. The PP-A power pack has an auxiliary relay to signal a change in occupancy to HVAC and BMS systems.
A variation to this design is to use PP-DIM dimming power packs. The will allow the lighting to remain on at a low level instead of completely off for emergency egress and/or provide daylight harvesting to satisfy energy codes if the corridor has windows or skylights.
Application Example – Corridor
Product Code Part Number
MINI-P-PP-A-FC 97180
MINI-S-PP-FC 97183
PP-A-J 97020
For Conference Room Alternative Product Code Part Number
MINI-P-PP-DIM-FC 97181
MINI-S-PP-FC 97183
PP-DIM-J 96017
MINI – One Size Fits All
18
MINI – One Size Fits All
Primary
PowerPack
Secondary Secondary
Zone 1
Fixtures on Emergency Circuit
Sensor
Power PackPowerPack
ControlsB.E.G.
19
MINI – One Size Fits All
The above example is of a public restroom with LED downlights and indirect cove lighting at an 8’ mounting height. Certain fixtures remain on 24 hours on the emergency circuit per building code so only one control zone is necessary. PP-A or PP-1 power packs are used with a primary and two secondary MINI sensors to extend the detection range over the toilet stalls. Since passive infrared (PIR) sensors require line of sight to detect motion, the MINI sensors must be placed above the toilet stalls where they can see minor motion. The sensors are spaced within the “seated activity” coverage range in each direction. The PP-A power pack has an auxiliary relay to signal a change in occupancy to HVAC and BMS systems.
A variation to this design is to use PP-DIM dimming power packs. The will provide daylight harvesting control to satisfy energy codes if the restroom has windows or skylights.
Application Example – Public Restroom
Product Code Part Number
MINI-P-PP-A-FC 97180
MINI-S-PP-FC 97183
PP-A-J 97020
For Conference Room Alternative Product Code Part Number
MINI-P-PP-DIM-FC 97181
MINI-S-PP-FC 97183
PP-DIM-J 96017
MINI – One Size Fits All
20
MINI – One Size Fits All
Primary
Primary
Primary
Secondary
Secondary
Secondary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Zone 1
Zone 2
Zone 3
Zone 4
Additional override switch
Sensor
Power PackPowerPack
ControlsB.E.G.
21
MINI – One Size Fits All
The above example is a school classroom with recessed 2x4 fixtures in a grid ceiling on 4’ x 6’ centers at a height of 10 feet. PP-DIM power packs are used to provide daylight harvesting and the room is divided into 4 control zones to achieve accurate daylight sensing. The spacing of the sensors ensures detection of seated minor motion activity. A 4-button low voltage momentary contact switch is wired to the power packs to provide a wall switch override and full range dimming. Where code that requires a vacancy sensor in private offices this mode is selected via a switch on the power pack. The power pack has an auxiliary relay to signal a change in occupancy to HVAC and BMS systems.
Fixtures with integral MINI sensors can be used instead of externally wired power packs and sensors to provide even more granular control and simplify installation.
Application Example – Classroom
Product Code Part Number
MINI-P-PP-A-FC 97180
MINI-S-PP-FC 97183
PP-A-J 97020
For Conference Room Alternative Product Code Part Number
MINI-P-PP-DIM-FC 97181
MINI-S-PP-FC 97183
PP-DIM-J 96017
MINI – One Size Fits All
22
MINI – One Size Fits All
Primary
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Primary
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Primary
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Primary
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Primary
Primary
Primary
Primary
PowerPack
PowerPack
PowerPack
PowerPack
Sensor
Power PackPowerPack
ControlsB.E.G.
23
MINI – One Size Fits All
The above example is of a school gymnasium. Each LED high bay fixture is mounted 30’ above the finished floor and has an integral internal PP-DIM power pack with the MINI GH sensor mounted on the exterior using the OEM fixture bracket. The fixtures are spaced 16’ x 16’. The power pack has an auxiliary relay to signal a change in occupancy to HVAC and BMS systems. This solution will provide occupancy sensing and daylight harvesting at a granular level as skylights and windows on two sides are contributing a substantial amount of ambient light during the daytime hours. Installation is also simplified since the controls are prewired in the fixtures from the factory.
Application Example – Gymnasium
Product Code Part Number
MINI-P-PP-DIM-GH-FC 97184
PP-A-J 97020
For Conference Room Alternative Product Code Part Number
MINI-P-PP-DIM-GH-FC 97184
PP-DIM-J 96017
MINI – One Size Fits All
Recommended