MILTECH-9012 – Data Sheet–Rev.2 -19.11.2014. (1)

Preview:

DESCRIPTION

datasheet, miltech

Citation preview

  • Driven by rapid advancement and lower costs, Ethernet is becoming the standard for IP-based components in a wide range of military and commercial applications, including:

    Battlemanagementsystems(BMSs) UAVs Landautonomousvehicles(UGVs) Robots Mobileequipmentfieldedinharshenvironments

    Modernplatformscontaindozensofnetworkdevicesthatmustbeinterconnected.TheMILTECH9012isanidealsolutionformobileEthernet-equippedplatforms.Withthebestcombinationofsize,weight,powerandcost(SWaP-C)intheindustry,itsavesvaluablerealestate for computers, sensors, targeting systems, andotherdevicesthatmakemobileplatformshighlyeffective.

    The 9012 is aMIL-STD, fullymanagedmilitarygrade network switch offering 12 triple-speed

    MILTECH9012Compact,PortableMilitaryManagedGigabitEthernetSwitch

    FEATURESDESCRIPTION

    (10/100/1000Mbps)ports.Itcanberemotelymanagedtooptimizecommunicationsandprioritizecriticalinformationtraffic.Advancednetworkfeatures,neverbeforefoundinapackageofthissize,includeswitchingprotocols,virtualLANS(VLANS),trafficprioritization(QoS),andbandwidthaggregationarestandard.

    TheMILTECH9012sgigabitspeedsand24VDCpowermakeitinstantlycompatiblewithanynetworkdeviceand power systems.

    TheMILTECH9012 iswidely used in battlefieldcommunicationsC4ISR,video,sensordataacquisitionandtransmission.Itsmechanicalpackagingenhancements,includingsealedSCE2circularconnectors,isdesignedforMIL-STD-810Fairborneandgroundenvironmentalcomplianceandhighreliability.Leveragingbest-in-classswitchingtechnologyfromTechaya,theMILTECH912servesasarobustcommercialoff-the-shelf(COTS)solutionforruggedLANconnectivity.

    SPECIFICATIONS

    Router/switchLayer3managed12X10/100/1000TXPorts.ETHERNETPORTS:

    Wire-speedhardware-based12portsgigabitEthernetswitchL2,L3,L4Capabilities

    L3-Routingcapabilities:static,RIPV1,V2,OSPFV2/V3MulticastRouting,BGP4*,VRRP,ECMPRouting

    Multicasting(IGMPSnooping),GARP,GMRP,MLDandGVRPupto8KgroupsforbothIPv4andIPv6

    BroadcastingandfloodingControlupto8KGroups 802.1qTaggedbasedVLANupto4KVLANgroups BridgeSupportforVLANQ-in-Q,manualtunneling LinkAggregation802.3ad,upto16membersingroup LinkAggregationmechanismbasedonL2/L3/

    L4parameters JumboFramesupportupto10K WEB,CLI,Telnet,SNMPV2/V3management

    NETWORKING:

    1TechayaP.O.Box1500,Pardes-Hanna,37100IsraelPhone:+972(4)6377741Fax:+972(4)6377761Email: info@techaya.com Web: www.techaya.com PRODUCTDATASHEETrev.2

  • SPECIFICATIONS

    QoSMulti-LayerClassifier:802.1p,EtherType, VLAN-ID,IPv4/6DSCP/ToS,andUDP/TCPports&rangestrafficclassification.

    PerportWFQandStrictQueuingscheduling DSCPremarkingforbothIPv4andIPv6frames Ingresspolicerandingressshaperperportwith500Kbpsgranularity Egressshaperperportwith500Kbpsgranularity Full-duplexflowcontrol(IEEE802.3X)andhalf-duplexbackpressure,symmetric and asymmetric

    NETWORKING:QualityofService:

    SecurityviaRadiusAuthentication802.1x,Port/MACaccesscontrol PortSecurity Per port ingress and egress port mirroring MirroringperVLANandpercontentawarenessmatch PrivateVLANsupportperVLAN(IsolatedandPromiscuousports) ContentAwarePolicers:

    128ContentAwarePolicers 16ContentAwareratepolicerswithratesfrom1fpsto32millionfps 8UDP/TCPportrangepolicers AdvancedACLthroughhardwarebasedmatchpatterns ContentAwarePolicersforgenericMAC,ARP,IPv4,IPv6protocols NorestrictiononanymixofentriestoContentAwarePolicers ContentAwarePolicersactionsarepermit/deny,police,count,snoopandmirror SpecialsupportforIPfragments,UDP/TCPportranges ExtensiveCPUDoSprevention SurveillancefunctionsbyContentAwarePolicerscounters MultipleACLsperportforoptimalusageofContentAwarePolicers

    Stormcontrollersforfloodedbroadcast,multicastandunicast

    SpanningTree(802.1d),RSTP(802.1w)andmultipleSpanningTree(802.1S)forfastrecoveryrings RPRforupto30unitsperringwithrecoverytime

  • SPECIFICATIONS

    96.8Mppswirespeedforwardingrate 56Gbpsmaximumforwardingbandwidth 8KMACAddress

    PERFORMANCE:

    ExceedMIL-STD-1275BandMIL-STD-704ASurgeandSpikeprotection VoltageInput:24VdcNominal(18-70V) PowerConsumption:20WTypical Chassisgrounding

    POWER:

    MIL-STD-461EElectromagneticcompatibility CE-102,CS-114,CS-115,CS-116,RE-102,RS-103

    ELECTROMAGNETIC:

    MIL-STD-810F;501.4I|501.4II|502.4I|502.4II|507.4|500.4II|514|516I|516VI|514.5|512.4SHOCK/VIBRATION/HUMIDITY:

    Dimensions:166.4mm(L)x144mm(W)x56mm(H)includingconnectors Weight:970g

    PHYSICAL:

    Setoffour4.5mmmountingholesonbottomformountingtoanyflatsurface.INSTALLATION:

    NoMovingParts.PassiveCooling.COOLING:

    -40Cto+85C(-40Fto+185F)ColdStart-UpOPERATINGTEMP:

    -40Cto+85C(-40Fto+185F)STORAGETEMP:

    *Currentlynotsupportedsoftwareupgradeoption.

    ORDERINGINFORMATION

    DESCRIPTIONPARTNUMBER

    ManagedMilitaryGradeGigabitSwitch,12x10/100/1000TXMILTECH9012

    StarterCablesetforMILTECH9012,SCE2toRJ-45Connectors,5feetlengthCBL-MIL9012-01

    TechayaP.O.Box1500,Pardes-Hanna,37100IsraelPhone:+972(4)6377741Fax:+972(4)6377761Email: info@techaya.com Web: www.techaya.com 3

    MILTECH9012Compact,PortableMilitaryManagedGigabitEthernetSwitch

    PRODUCTDATASHEETrev.2

    1

    1

    2

    2

    3

    3

    4

    4

    5

    5

    6

    6

    7

    7

    8

    8

    A A

    B B

    C C

    D D

    E E

    F F

    DRAWN

    DATE

    OF /PATH:

    MATERIAL:

    CHECKEDAPPROVED

    DESIGNED

    DWG TITLE

    DWG No.

    SCALESIZE

    SHEET

    THIS DOCUMENT SHALL NOT BE REPRODUCED, NOR SHALL THE INFORMATION CONTAINED HEREIN BE USED BY OR DISCLOSED TO OTHERS EXCEPT AS EXPRESSLY AUTHORIZED IN WRITINGBY TECHAYA LTD.

    UNSPECIFIED TOLERANCES:- LINEAR DIMENSIONS PER ISO 2768-1(DIN 7168), GRADE-HOLES & OPENINGS DIMENSIONS: H-SHAFTS & EXTERNAL DIMENSIONS: h-ANGULAR DIMENSIONS: 0.5 UNSPECIFIED GEOMETRICALTOLERANCES PER ISO 2768-2(DIN 7168), GRADE:

    FINISH:SURFACE

    ROUGHNESS:

    NAMENOMINAL DIMENSIONS AND GEOMETRY ARE ACCORDING TO STEP FILE:

    Tel: +972-4-6377741P.O.B. 1500 Pardes Hanna, 37100, Israel

    REMOVE BURRS & SHARP EDGES 0.3X45

    PROJECT NAME:

    Fax:+972-4-6377761

    ALL DIMENSIONS ARE IN MM.DON'T SCALE DRAWING.CHANGES MUST BE MADE ON MODEL FILE.

    WEIGHT: REV.

    MT9012 ICD

    90120000ICD

    1 1 D:\Works\TECHAYA MT 9012\MT 9012 ICD.idw

    04/07/2012

    L.V.

    A2

    MT9012

    2

    Techaya Ltd

    REVISION HISTORYZONE REV DESCRIPTION DATE APPROVED

    1 1 RELEASE 7/30/2012 max 2 COG ADDED 21.01.2013 GD

    166.4

    144.09

    6.026

    .0

    60.0

    103.2

    24.7 39.0117.0

    24.5

    20.0

    20.0

    24.5

    #8-32NCCROUNDING SCREW

    INDICATORS PANEL

    SEALING TESTHOLE. SEALED WITH M5SEAL SCREW.

    NAME PLATE#8-32NC GROUNDINGSCREW.

    SCE2-x-76A07-10ASX-002AMPHENOL CONNECTOR

    SCE2-76A07-14S

    5.2

    156.0

    4.3(X4)

    41.2 5

    5.9

    33.3

    85.0

    54

    35

    25.8

    NOTES: 1. MATERIALS: BODY AL. ALLOY 6061-T651 PER AMS QQ-250/11 OR AMS QQ-A-250/B. ALL FASTENERS -STAINLESS STEEL AISI 300 SERIES. 2. FINISH: CHEMICAL CONVERSION FILM PER MIL-DTL-5541F, TYPE I, CL.1A. (goldy) PAINTING: - ONE LAYER OF PRIMERY COAT STRONCIUM CHROMATE PER MIL-P-23377, THICKNESS 15-20 mkm. - TOP COAT POLYURETHANE CARC PER HENTZEN SPEC 15801GPA-2/03059CMU. COLOR NATO GREEN, TWO COATS 40-50 MICRONS THICK. 3. WEIGHT: 1.5 Kg.

    81.0

    70.0

    81.0

    20.0

    COG

    COG2

    2

    11

    22

    33

    44

    55

    66

    77

    88

    AA

    BB

    CC

    DD

    EE

    FF

    DRAWN

    DATE

    OF/PATH:

    MATERIAL:

    CHECKEDAPPROVED

    DESIGNED

    DWG TITLE

    DWG No.

    SCALESIZE

    SHEET

    THIS DOCUMENT SHALL NOT BE REPRODUCED, NOR SHALL THE INFORMATION CONTAINED HEREIN BE USED BY OR DISCLOSED TO OTHERS EXCEPT AS EXPRESSLY AUTHORIZED IN W

    RITINGBY TECHAYA LTD.

    UNSPECIFIED TOLERANCES:- LINEAR DIMENSIONS PER ISO 2768-1(DIN 7168), GRADE-HOLES & OPENINGS DIMENSIONS: H-SHAFTS & EXTERNAL DIMENSIONS: h-ANGULAR DIMENSIONS: 0.5 UNSPECIFIED GEOMETRICALTOLERANCES PER ISO 2768-2(DIN 7168), GRADE:

    FINISH:SURFACE

    ROUGHNESS:

    NAMENOMINAL DIMENSIONS AND GEOMETRY ARE ACCORDING TO STEP FILE:

    Tel: +972-4-6377741P.O.B. 1500 Pardes Hanna, 37100, Israel

    REMOVE BURRS & SHARP EDGES 0.3X45

    PROJECT NAME:

    Fax:+972-4-6377761

    ALL DIMENSIONS ARE IN MM.DON'T SCALE DRAW

    ING.CHANGES MUST BE MADE ON MODEL FILE.

    WEIGHT:

    REV.

    MT9012 ICD

    90120000ICD

    1 1

    D:\Works\TECHAYA MT 9012\MT 9012 ICD.idw

    04/07/2012

    L.V.

    A2

    MT9012

    2

    Techaya Ltd

    REVISION HISTORYZONE

    REVDESCRIPTION

    DATEAPPROVED

    11

    RELEASE7/30/2012

    max

    2COG ADDED

    21.01.2013GD

    166.4

    144.096.026.0

    60.0103.2

    24.739.0

    117.0

    24.5 20.0 20.0

    24.5

    #8-32NCCROUNDING SCREW

    INDICATORS PANEL

    SEALING TESTHOLE. SEALED W

    ITH M5SEAL SCREW

    .

    NAME PLATE#8-32NC GROUNDINGSCREW

    .

    SCE2-x-76A07-10ASX-002AMPHENOL CONNECTOR

    SCE2-76A07-14S

    5.2

    156.0

    4.3(X4)

    41.2

    55.9

    33.3

    85.0 54

    35

    25.8

    NOTES: 1. MATERIALS: BODY AL. ALLOY 6061-T651 PER AMS QQ-250/11 OR AMS QQ-A-250/B. ALL FASTENERS -STAINLESS STEEL AISI 300 SERIES. 2. FINISH: CHEMICAL CONVERSION FILM PER MIL-DTL-5541F, TYPE I, CL.1A. (goldy) PAINTING: - ONE LAYER OF PRIMERY COAT STRONCIUM CHROMATE PER MIL-P-23377, THICKNESS 15-20 mkm. - TOP COAT POLYURETHANE CARC PER HENTZEN SPEC 15801GPA-2/03059CMU. COLOR NATO GREEN, TW

    O COATS 40-50 MICRONS THICK. 3. W

    EIGHT: 1.5 Kg.

    81.0

    70.0

    81.0

    20.0

    COG

    COG2

    2

    A B