002402-5-EN IL50 GLO August 2017© 2017 Honeywell International Inc. All rights reserved.
MICRO SWITCH™ Hazardous Area SwitchesHazardous Location Approvals
* Select catalog listings
While Honeywell provides application assistance personally, through its literature and the Honeywell Web site, it is up to the customer to determine the suitability of the product in the application.
Agency Approval BX
HazardousDesignations BX2 VPX EAC (GOST-R)
Sealing WBX cULus cULus UL
Operating Temp. GSX CX cULus ATEX (CE) ATEX (CE) CSA
cULus UL ATEX (CE) EAC (GOST-R) IEC Ex ATEX (CE)
EX ATEX CSA IEC Ex IEC Ex KOSHA IEC Ex
IS-WPS UL IEC Ex ATEX (CE)* FCC, IC, ETSI INMETRO NEPSI INMETRO
cULus CSA KOSHA IEC Ex* Div I & 2, Class IGroups B, C, & D KOSHA II G Ex ia IIC T4 Ga
(prox version) KOSHA
GXA/GXE LSX ATEX ATEX (CE) INMETRO INMETRO* Div I & 2, Class IIGroups E, F, & G NEPSI II D Ex ia IIIC T135°C Da
(prox version) NEPSI
CLSX ATEX (CE) UL IEC Ex IEC Ex Div I & 2, Class IGroups B, C, & D
Div I & 2, Class IGroups B, C, & D II 1 G Ex ia IIC T4 Ga Div I & 2, Class I
Groups B, C, & D II 2 G Ex db IIC T6 Gb Div I & 2, Class IGroups B, C, & D
14CE100 UL IEC Ex CSA Class I, Div I, Groups A, B, C, D T4 INMETRO Div I & 2, Class II
Groups E, F, & GDiv I & 2, Class IIGroups E, F, & G II 1 D Ex ia IIIC T135C Da Div I & 2, Class II
Groups E, F, & G II 2 D Ex tb IIIC T85°C Db Div I & 2, Class IIGroups E, F, & G
ATEX (CE) CSA KOSHA Div I & 2, Class IGroups B, C, & D
Class I, Zone 1 AEx ia IIC T4 GaClass I, Zone 1 Ex ia IIC T4 Ga
Div I & 2, Class IGroups B, C, & D II 2 G Ex d IIC T6 Gb II 2 G Ex d IIC T6 Class I, Zone 0, AEx ia IIC T4 Ga;
Class I, Zone 1, AEx ia IIC T4 GaII 2 G Ex d IIC T6 Gb
1 Ex d IIC T6 Gb IP66/67 II 2 G Ex d IIC T6 Gb1 Ex d IIC T6 Gb
II 2 G Ex d IIC T6 Div I & 2, Class IGroups B, C, & D II 2 G Ex d IIC T6 Div I & 2, Class II
Groups E, F, & GClass I, Zone 0 AEx ia IIC T4 GaClass I, Zone 0 Ex ia IIC T4 Ga
Tambient -40° C to +70 C°Div I & 2, Class IIGroups E, F, & G II 2 D Ex t IIIC IP6X T85C Db II 2 D Ex tD A21 IP66 T85C
Class II, Zone 20, AEx ia IIIC T135°C; Class II, Zone 21, AEx
ia IIIC T135°CII 2 D Ex tb IIIC T85C Db
NEMA 1, 3, 4, 4X, 6, 13
II 2 D Ex tb IIIC T85C Db
II 2 D Ex tD A21 T85C Div I & 2, Class IIGroups E, F, & G II 2 D Ex tD A21 T85C IP67 Zone 1 Ex ia IIC T4 Ga;
Zone 0 Ex ia IIC T4 GaEX: II 2 G Ex d IIB + H2 T6 Gb
EXHT: II 2 G Ex d IIB + H2 T2 Gb IP67 IP66/67 IP67 IP67 -40 °C to 50 °C(4 EM switch version) IP67
IP65/66/67 NEMA 1, 3, 4, 13 IP66 NEMA 1, 3, 4, 6, 13 IP65, IP67 (self certified) NEMA 1 NEMA 1, 4, 6, 12, 13 NEMA 1, 3, 4, 4X, 6, 6P, 13 NEMA 1, 3, 4, 6, 13 NEMA 1, 3, 4, 4X, 6, 13 -40 °C to 60 °C(2 EM switch version) NEMA 1, 3, 4, 6, 13
0 °C to 70 °C -25 °C to 40 °C 3 A: -20 °C to 75 °C4 A: -20 °C to 60 °C -40 °C to 121 °C -40 °C to 70 °C EX: -40 °C to 70 °C
EXHT: -40 °C to 204 °C -40 °C to 70 °C -40 °C to 70 °C -40 °C to 70 °C -40 °C to 70 °C -40 °C to 80 °C(prox switch version) -40 °C to 70 °C
Honeywell Sensing and Internet of Things9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com
Introduction
There are many considerations when selecting a switch to be used in
hazardous areas. In addition to switch performance, it’s important to
understand the country of use, as well as the approvals each switch
carries. This selection guide will help to define Hazardous Area Approvals
and Markings for both North American and Global applications, as well as
define the approvals MICRO SWITCH Hazardous Area Switches carry.
For assistance with selecting a hazardous area switch, please contact
Honeywell’s product team at +1-815-235-6847, info.sc@honeywell.com,
or your Honeywell distributor.
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit SwitchesA Selection Guide
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 2
North American Typical Marking
North American Traditional MarkingHazard Class Area Classification1 Gas/Dust Group
Class I Division 1 Groups A, B, C, D
Class I(NEMA Type 7)
Flammable Gas, Vapors, & Mist Division 1The hazardous gas/dust is continuously present or intermittently present during normal operation
Group A Acetylene
Group B Hydrogen
Group C Ethylene
Group D Propane and Methane
Class II(NEMA Type 9)
Combustible Dust Division 2 The hazardous gas/dust is only present under abnormal conditions
Group E Combustible metal dusts
Group F Combustible carbonaceous dusts
Group G Other combustibles (flour, grain, wood, plastic, chemicals)
1 If a product is covered for Division 2, it will be marked. If the Division is not included in the marking, then it is presumed to be Division 1. Division 1 certified products can be used in Division 1 or 2 areas.
North American Zone Style Marking
Hazard Class Area Classification American National Standard Explosion Protected Protection
Concept Gas/Dust Group Temperature Class Equipment Protection Level
Class I Zone 0 A Ex d IIC T6 Ga
Class I Flammable Gas, Vapors & Mist
Zone 0 Hazardous gas is continuously present
A
Approved to US Standard ISA 60079-*. Differentiates between this Certification and the ATEX and IEC Ex Certifiacations with use the EN and IEC 60079-* Standards
ExDevice is explosion protected for use in hazardous environments
Protection method the product uses to be used in the hazardous environment
IIC 2 Acetylene and Hydrogen T6 3 Maximum surface temperature of 85 °C
Ga Gas, suitable for Zones 0, 1, 2
Zone 1Hazardous gas intermittently present during normal operations
dFlame proof. Can contain the explosion and extinguish the flame
IIB + H2 Ethylene and Hydrogen T5 Maximum surface temperature of 100 °C
Gb Gas, suitable for Zones 1, 2
Zone 2 Hazardous gas present under only abnormal conditions
IIB Ethylene T4 Maximum surface temperature of 135 °C
Gc Gas, suitable for Zone 2
Class II Combustible Dust
Zone 20 Hazardous dust is continuously present
IIA Propane and Methane T3 Maximum surface temperature of 200 °C
Da Dust, suitable for Zones 20, 21, 22
ia,ib,ic
Intrinsically Safe. Limits energy of sparks and surface temperature
Zone 21Hazardous dust intermittently present during normal operations
IIIC Combustible metal dusts T2 Maximum surface temperature of 300 °C
Db Dust, suitable for Zones 21, 22
Zone 22 Hazardous dust present under only abnormal conditions
IIIB
Combustible carbonaceous dusts and other combustibles (flour, grain, wood, plastic, chemicals)
T1 Maximum surface temperature of 400 °C
Dc Dust, suitable for Zone 22
2 Typically, IIC is the preferred coverage and will allow the product to be used in IIB and IIA environments as well.3 Typically, T6 is the preferred coverage and will allow the product to be used in T5-T1 requests (dependent upon the ambient temperature of the application). Most Honeywell limit switches are T6 rated.
Comparison on the two Area Classification StylesHazard Level Division Scheme Zone Scheme
Continuous HazardDivision 1
Zone 0/Zone 20
Intermittent Hazard Zone 1/Zone 21
Hazard Under Abnormal Conditions Division 2 Zone 2/Zone 22
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 3
North American Typical Marking
North American Zone Style Marking
Hazard Class Area Classification American National Standard Explosion Protected Protection
Concept Gas/Dust Group Temperature Class Equipment Protection Level
Class I Zone 0 A Ex d IIC T6 Ga
Class I Flammable Gas, Vapors & Mist
Zone 0 Hazardous gas is continuously present
A
Approved to US Standard ISA 60079-*. Differentiates between this Certification and the ATEX and IEC Ex Certifiacations with use the EN and IEC 60079-* Standards
ExDevice is explosion protected for use in hazardous environments
Protection method the product uses to be used in the hazardous environment
IIC 2 Acetylene and Hydrogen T6 3 Maximum surface temperature of 85 °C
Ga Gas, suitable for Zones 0, 1, 2
Zone 1Hazardous gas intermittently present during normal operations
dFlame proof. Can contain the explosion and extinguish the flame
IIB + H2 Ethylene and Hydrogen T5 Maximum surface temperature of 100 °C
Gb Gas, suitable for Zones 1, 2
Zone 2 Hazardous gas present under only abnormal conditions
IIB Ethylene T4 Maximum surface temperature of 135 °C
Gc Gas, suitable for Zone 2
Class II Combustible Dust
Zone 20 Hazardous dust is continuously present
IIA Propane and Methane T3 Maximum surface temperature of 200 °C
Da Dust, suitable for Zones 20, 21, 22
ia,ib,ic
Intrinsically Safe. Limits energy of sparks and surface temperature
Zone 21Hazardous dust intermittently present during normal operations
IIIC Combustible metal dusts T2 Maximum surface temperature of 300 °C
Db Dust, suitable for Zones 21, 22
Zone 22 Hazardous dust present under only abnormal conditions
IIIB
Combustible carbonaceous dusts and other combustibles (flour, grain, wood, plastic, chemicals)
T1 Maximum surface temperature of 400 °C
Dc Dust, suitable for Zone 22
2 Typically, IIC is the preferred coverage and will allow the product to be used in IIB and IIA environments as well.3 Typically, T6 is the preferred coverage and will allow the product to be used in T5-T1 requests (dependent upon the ambient temperature of the application). Most Honeywell limit switches are T6 rated.
Comparison on the two Gas/Dust Group StylesSubstance Hazard Class Division Groups Zone Groups
Acetylene
Class I
Group A IIC
Hydrogen Group B IIC
Ethylene Group C IIB
Propane Group D IIA
Methane Group D IIA
Combustible metal dusts
Class II
Group E IIIC
Combustible carbonaceous dusts Group F IIIB
Other combustibles (flour, grain, wood, plastic, chemicals)
Group G IIIB
North American Product Label Example
North American Approvals Agency
North American Zone Style Marking
NEMA Environmental Seal Rating
North American Traditional Marking
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 4
ATEX and IEC Ex Typical Marking
ATEX and IEC Ex Typical Marking • Part 1
Complies with European Directive
Notified Body Number
Specific marking for ATEX Directive Equipment Group Equipment
Category Environment
0518 II 2 GD
All products that comply with any European Directive are marked with CE. This can be the Ex-plosive Atmospheres Directive (ATEX) or any number of other Directives
Each notified body (agen-cy) has a number. Honey-well places the number of the notified body that certifies the factory on the label. 0518 will be on all ATEX products from Galena, Illinois. 1180 will be on all ATEX products from Newhouse. Scotland
All products that comply with the ATEX Directive for Explosive Atmo-spheres will be labeled with this symbol
I Mines 1
Products can be used in Zones 0, 1, 2 and 20, 21, 22
G Gas environments
II All other areas 4 2
Products can be used in Zones 1, 2 and 21, 22
D Dust environments
3Products can be used in Zones 2 and 22
4 Honeywell products will all be Equipment Group II. None of our products are certified to be used in mining applications.
ATEX and IEC Ex Typical Marking • Part 2
Explosion Protect-ed Protection Concept Gas/Dust Group Temperature Class Equipment Protection
Level (EPL)
Ex d IIC or IIIC T6 or T85°C Ga
The device is explosion protected for use in haz-ardous environments
The protection method the product uses to be able to be used in the hazardous environment
IIC 2 Acetylene and Hydrogen
T6 3Maximum surface temperature of 85 °C
Ga Gas, suitable for Zones 0, 1, 2
IIB + H2 Ethylene and Hydrogen
T5Maximum surface temperature of 100 °C
Gb Gas, suitable for Zones 1, 2
d
Flame proof. Con-tains the explosion and extinguish the flame
IIB Ethylene T4Maximum surface temperature of 135 °C
Gc Gas, suitable for Zone 2
IIA Propane and Methane
T3Maximum surface temperature of 200 °C
Da Dust, suitable for Zones 20, 21, 22
ia, ib,ic
Intrinsically safe. Limits energy of sparks and surface temperature
IIIC Combustible metal dusts
T2Maximum surface temperature of 300 °C
Db Dust, suitable for Zones 21, 22
IIIB
Combustible carbonaceous dusts and other combustibles (flour, grain, wood, plastic, chemicals)
T1Maximum surface temperature of 400 °C
Dc Dust, suitable for Zone 22
2 Typically, IIC is the preferred coverage and will allow the product to be used in IIB and IIA environments as well.3 Typically, T6 is the preferred coverage and will allow the product to be used in T5-T1 requests (dependent upon the ambient temperature of the application). Most Honeywell limit switches are T6 rated.
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 5
ATEX and IEC Ex Typical Marking
ATEX and IEC Ex Product Label Example
Complies with European Directory
Notified Body Number
Specific marking for ATEX Directive
ATEX Typical Protection Marking
Area Classification StylesHazard Level Zone Scheme
Continuous Hazard Zone 0/Zone 20
Intermittent Hazard Zone 1/Zone 21
Hazard Under Abnormal Conditions Zone 2/Zone 22
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 6
MICRO SWITCH Hazardous Area Switch Approvals
EX CX LSX BX BX2 GSX CLSX GXS 14CE100 IS-WPS WBX VPX
l l l l l
� l l l l l
l l l l l
l l* l l l l l l l l
l l* l l l l l l l
l l* l l l l l l l
l l
l l l l* l
l l l
l* l l l
* Select catalog listings
SELECTION GUIDE | Guide to Hazardous Location Approvals | sensing.honeywell.com 7
Global Approval Descriptions
Mark Country Approval Description
North AmericaUL Mark means UL has tested representative samples of the product and determined the product meets the requirements of UL. These requirements are based primarily on published and nationally recognized Standards for Safety.
� North America
The CSA mark demonstrates that a sample of the product has been certified to applicable standards including standards written or administered by the American National Standards Institute (ANSI), Underwriters Laboratories (UL), CSA Group (CSA), NSF International (NSF), and other North American and global organizations.
United States and Canada
The cULus mark certifies the equipment was evaluated to Canadian and US standards by Un-derwriters’ Laboratories. The combination mark indicates compliance with both Canadian and U.S. Requirements. “Listed” means that the product can be operated as sold, in accordance with its inscriptions and operating instructions, without retesting by UL. Products are for use in hazardous locations where explosive atmospheres may be present. Certification covers division and zone area classification systems for the United States and/or Canada.
EuropeThe Ex mark is a statement from an independent Notified Body verifying compliance with the requirements of the European standards that are harmonised with the 94/9/EC Directive (ATEX Directive, named after the French “ATmosphere EXplosible”).
Global
The IEC Ex mark means the equipment complies with the requirements of the International Electrotechnical Commission Explosive. The objective of the IECEx system is to facilitate inter-national trade in equipment and services for use in explosive atmospheres, while maintaining the required level of safety.
EuropeNotified Body. For equipment used in the European Union in accordance with the R&TTE Directive, the CE Mark and the notified body (NB) identification number is used when the NB is involved in the conformity assessment procedure.
EurAsian Conformity
Products certified are labelled with Customs Union Mark of Conformity, called EurAsian Conformity Mark – EAC, before they are placed on the market of the Customs Union member states (Russia, Belarus and Kazakhstan).
Korea
Korea’s “Electrical Communication Basic Law,” requires EMC testing and certification for many electronic products. Korean EMC certifications are issued by National Radio Research Agency (RRA), which is organized under the Korea Communications Commission (KCC). EMC testing includes electromagnetic interference (EMI) and susceptibility (EMS). Certified equipment is labeled with the KC mark and certification number.
China
NEPSI is an international testing laboratory accredited by IECEx Scheme, Shanghai Inspection and Testing Center of Electrical Equipment for use in Explosive Atmospheres for National Work Safety authorized by China State Administration of Work Safety (with qualification of Class A). NEPSI runs strictly in accordance with ISO/IEC 17025 and ISO/IEC 17020.
BrazilBrazil’s IN METRO (Institute of Metrology, Standardisation and Industrial Quality) is the gov-ernment body responsible for the implementation of measurement, safety and quality stan-dards for electrical and electronic products.
Warranty/RemedyHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is customer’s sole responsibility to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.
SALES AND SERVICEHoneywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or:
E-mail: info.sc@honeywell.comInternet: sensing.honeywell.com
Phone and Fax:Asia Pacific +65 6355-2828 +65 6445-3033 FaxEurope +44 (0) 1698 481481 +44 (0) 1698 481676 FaxLatin America +1-305-805-8188 +1-305-883-8257 FaxUSA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax
For more informationTo learn more about Honeywell’s
sensing and switching products,
call 1.800.537.6945 , visit sensing.honeywell.com,
or e-mail inquiries to info.sc@honeywell.com
Honeywell Sensing and Internet of Things 9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywell.com002399-4-EN | 4 | 8/17© 2017 Honeywell International Inc.
Recommended