Mechanical Test Specimens Plan

Preview:

DESCRIPTION

Partial Repair PQR

Citation preview

PLAN DE DECOUPAGE POUR ESSAIS MECHANIQUEPLAN FOR MECHANICAL TEST SPECIMENS

Doc.Ref : PDC_CONT-2/2014-2Doc Ref. :

Date :10/11/2014

DONNÉES GÉNÉRALES / GENERAL DATACLIENT/ CLIENT: ECM+INSPECTEUR/ INSPECTOR: Ali TrabelsiDATE D’INSPECTION/ DATE: 10/11/2014LIEU D’INSPECTION/LOCATION : BERI Yard - GABES

REFERENCES/STANDARDS : API 1104 OMV SPEC. N°: STOD-GEN-AED-0000-YL-SPE-0011

DMOS N°/ WPS N° : 04/14 – Partial RepairQMOS N°/PQR N° : 04/14 – Partial Repair

PLAN DE DECOUPAGE / CUTOUT PLAN

TensileStrength Nick Break Root Bend Face Bend Side bend Macro /

HardnessCharpyImpact Total

01 01 00 01 00 01 03 7

15 Rue ChedliGtari ElMenzah 9, 2092 Tunis,TUNISIETél: +216 71 88 66 44Fax:+216 70 01 42 83sis@sistn.comwww.sistn.com

ESSAI DE TRACTION/ TENSILE STRENGTH TEST

ESSAI DE PLIAGE / BEND TEST

MACRO-DURETE VICKERS HV10/ MACRO-HARDNESS VICKERS HV10

ESSAI DE RESILIENCEEN ‘’V’’ / CHARPY IMPACT V-notch

MALEK2
Highlight
Locations and number of indentations shall comply with API 1104, Figure 22—Hardness Locations for Partial Thickness Repair Procedure Qualification at Weld Centerline. and not Figure 21—Hardness Locations for Full Thickness Repair Procedure Qualification.

V-notch in center of weld. V-notch in the fusion line. V-notch at +2 mm from the fusion line in the parent material.

NB: The test temperature at (-20°C).

ESSAI DE TEXTURE/ NICK BREAK

INSPECTEUR SiS / SiS INSPECTOR APPROUVÉ PAR / APPROVED BY AUTRE / OTHERNom/ Name: Ali TrabelsiDate : 19/11/2014Signature :

Nom/ Name: Ezzeddine Ben KraiemDate :19/11/2014Signature :

Nom/ Name:Date :Signature :

10 mm

55 mm

= t

2 mm

10 mm

55 mm

= t

10 mm

55 mm

= t

FQ-T

EC-6

04-I

R: 0

1-Ed

ition :

11/2

014

Recommended