LINUS - Braile · LINUS Stent-Graft LINUS Braile Biomédica Indústria, Comércio e...

Preview:

Citation preview

LINUS

www.braile .com.br

Stent-Graft LINUS

Braile Biomédica Indústria, Comércio e Representações Ltda.Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim Tarraf IZipe Code 15091-450 • São José do Rio Preto • SP • BrazilPhone #55 17 2136 7000 • Fax #55 17 2136 7040Federal Tax ID: 52.828.936/0001-09Technician in charge: Vladimir D. A. Ramirez • CRF/SP 9010ANVISA Reg. nº 10159030096www.braile.com.br

Cata

logu

e Co

de 6

0450

7Re

v .

Length A

Length Length B

1 23

3

4

Total Length

Total Length

600mm

Length Length

56

1 | Extensão Aórtica

Diameter24 until 36 mm

Length40 mm

Profile18 - 20Fr

2 | Main Body

Proximal Diameter24 until 36 mm

Distal Diameter14 mm

Profile18 and 20Fr

3 | Iliac Extension

Proximal Diameter14 mm

Distal Diameter12 - 14 - 16 - 18 20 - 22 mm

Length40 - 60 - 80 - 100120 - 140 mm

Profile16Fr

Length A80 and 155 mm

Length B75 mm

Free Flow20mm

Free Flow20mm

6 | Oclusor

Diameter14 until 22 mm

Diameter20 mm

Profile16Fr

*Refer to availability of other dimensions.

5 | Aortic-iliac4 | Cuff Distal

Proximal Diameter24 until 36 mm

Distal Diameter14 mm

Profile18 and 20Fr

Length90 and 150 mm

Free Flow20mm

Proximal Diameter12 until 22 mm

Distal Diameter12 until 22 mm

Length40 mm

Profile16Fr

Stent-Graft DominusANVISA Reg. nº 10159030093

Non-coated stent forexpansion of attaching area

Free Flow

Sutures made of polyester forattaching the metallicframework

Sutura

Radial ForceProximal and distal areas with

increased radial force forimproving attachment and

sealing

Proximal and distal areasfor easing the location and

position of stent-graft

Radiopaque Marks

CoatingLow porosity tubularpolyester

NitinolSuperelastic metal alloywith thermal memoryHighly resistant tocorrosion and fatigue

Balloon CatheterCompliant for accommodating

stent-graft 12 Fr/45 mmSupplied separately

Modular ExtensionsContralateral

ExoskeletonYpsilateral

Regi

stro

AN

VISA

nº 1

0159

0300

66

Flexible TipAtraumatic radiopaque

HydrophilicHydrophilic coating forreducing friction

Anti-KinkFor a betternavigability

AccuracyForce multiplier system

LOW PROFILE

18 -20FrFlexibility

Higher accuracy and safety

Less friction

Self-expanding metallic stent graft, coated withpolyester and Nitinol structure.

Attached by Radial Force

Recommended oversize of 15 to 20%concerning the attaching neck diameterSafety lock

Safety lock

Recommended