©CBS20 STANWIX STREET, 10TH FLOORPITTSBURGH, PENNSYLVANIA 15222
March 18, 2011
To: DISTRIBUTION
Dorothy M. AlkeVice President, Environmental Projects
412.642.2562 Telephone412.642.3014 Fax
dottie.alke @ cbs.com
Re; Surface Water, Flow and Water Level MonitoringSecond Quarter 2010Neal’s Landfill, Bloomington, Monroe County, Indiana
1.0 BACKGROUND
This report summarizes the results of surface water, flow and water level monitoring workcompleted by CBS Corporation during the second quarter of 2010 at the Neal’s Landfill site.
Surface water monitoring was performed at a total of three locations (springs and streams) inaccordance with the April 2002 Long Term Groundwater Monitoring Plan (LTGMP) for this site.The LTGMP was modified by agreement with the CD parties in December 2009. The modificationdiscontinues storm sampling as well as semi-annual sampling at Taylor and Branam Springs untilthe next revision of the LTGMP. Continuous monitoring of flow and water levels was alsoperformed at two locations.
2.0 SURFACE WATER MONITORING
The monitoring work described in this report was performed on March 31, April 21 and May 25,2010. The March-May time period constituted the second reporting quarter for Neal’s Landfill for2010.
Scope of Work
The scope of water sampling for this monitoring period comprised monthly sampling at SouthSpring and North Spring, as stipulated in the modified LTGMP and summarized in Table 1. SinceDecember 2004, surface water samples also have been collected from a small pool in Conard’sBranch near Vernal Pike. The approximate locations of these stations are shown on Figure 1,Monitoring and Sampling Locations.
March 18, 2011Page 2
Sample Collection and Handling
Samples at the spring and stream locations were collected by carefully filling a new disposablebeaker. The water was transferred from the beaker into pre-cleaned amber glass l-liter bottlessupplied by the analytical laboratory. Routine sampling parameters including temperature andconductivity were measured and recorded.
Samples were analyzed by Heritage Lab of Indianapolis, Indiana. All the samples except theConard’s Branch Pool samples were analyzed to a detection limit of 0.1 parts per billion (ppb) forall PCB parameters (except Aroclor 1221, detection limit 0.2 ppb) by EPA SW-846 method 8082.The Conard’s Branch Pool samples were analyzed to a detection limit of 0.01 ppb for all PCBparameters (except Aroclor 1221, detection limit 0.02 ppb). Samples were also analyzed for totalsuspended solids (TSS) by EPA method 160.2.
Quality Assurance
For quality assurance purposes a duplicate sample and a field blank were collected during eachsampling event. All environmental and blank samples were labeled and logged onto a chain ofcustody form. The samples were stored and transported on ice in insulated coolers. Custody of thewater samples was maintained by CBS until shipment to the analytical laboratory.
Field blank samples for these sampling events were NL5756, NL5761 and NL5766. No PCBs weredetected in any of these samples.
Analytical Results for Surface Water Samples
Field parameter measurements, PCB analytical results, and QA/QC results for samples collectedfrom South Spring and North Spring during this reporting period are reported in Tables 2 and 3.Historical groundwater monitoring data collected since the completion of the remedy in November1999 for these two sampling stations are also reported in Tables 2 and 3. Results of water samplingat the Conard’s Branch Pool station since December 2004 are reported in Table 4. Copies of thechain of custody forms are provided in Appendix A. Copies of the certificates of analysis areprovided in Appendix B. A validation summary for these samples appears in Appendix C. Copiesof the field sampling data sheets are on file at PSARA Technologies, Inc.’s Bloomington BranchOffice.
3.0 CONTINUOUS FLOW AND WATER LEVEL MONITORING
The purpose of flow and water level monitoring is to evaluate site-specific data characterizing sitehydrologic response under storm and non-storm conditions, and to evaluate correlations betweenPCB concentrations, spring flow and groundwater elevations.
March 18, 2011Page 3
Scope of Work
The scope of groundwater level and flow monitoring during this reporting period involved the useof dedicated instrumentation to record water level and other parameters as summarized in Table 5.Water lever transducers and data logging equipment and piezometer crest gauges were operatedduring all or part of the period from March through May 2010. The approximate locations of thestations in which these instruments were used are shown on Figure 1, Monitoring and SamplingLocations.
Flow and Water Level Plots
The following plots of the monitored stations for this reporting period are attached:
Flow data and monthly cumulative rainfall at Conard’s Branch weirater elevation at MW EPA-5A
The plots are annotated with dates of instrument installation or removal and other field activities ofinterest.
Quality Assurance
As a quality assurance check in documenting rain events and changes in flow and groundwaterlevel, rainfall records were obtained from the Neal’s Landfill recording rain gage and, if necessary,from those at Monroe County Airport, Indiana University, the PSARA Bloomington office and theIllinois Central Spring Treatment Facility. Rain events of approximately 0.25 inches or more areindicated on the flow and water level plots.
As a further data quality check, manual water level measurements were made after significant stormevents. The purpose of the manual checks was to verify instrument readings. Manual field checkdata collected during this reporting quarter are shown on the data plots.
An instrument maintenance log for all of the Neal’s Landfill installations is provided inAppendix D. This log details the installation, re-indexing, and maintenance history of thetransducers and data loggers present at Neal’s Landfill during the reporting quarter.
Crest Gauges
The purpose of these gauges is to provide an indication of maximum water level in the piezometersthat do not contain level logging transducers. Crest gauge measurements appear in Table 6.Piezometer-01 has neither a transducer nor a crest gauge, but the water level at this station ismeasured manually. Those observations appear in Table 7.
March 18, 2011Page 4
Potentiometric Data
On May 28, 2010, water levels were measured by hand at eleven monitor wells at the site plus threeadditional monitoring points. The added water level monitoring points are two boreholes in thesoutheast area of the site, BH-A2 and BH-B2, and a standpipe installed in the buried SW SeepSinkhole. The specific measurement locations are listed in the table insert on Figure 1, which alsodepicts the resulting potentiometric surface across the site on this date.
Scope of Non-Routine Activities
Pumping operations at the Conard’s Branch Pump (CBP) station continued during the secondreporting quarter of 2010. The system operated in automatic mode throughout the quarter.Maintenance of the system during this quarter involved the removal of storm debris and thecleaning of accumulated sediment and algae from the intake screens as needed. Operation duringthe third reporting quarter for 2010 is expected to be in automatic mode.
If you have questions regarding the sampling and flow/water level monitoring activities or findingsfor this reporting quarter, please call Mike McCann at (812) 335-0424.
S inc~j~ly,
Dorothy M. Alke
BP: 11-0020
Attachments
DISTRIBUTIONTom Alcamo, USEPA Region 5Jessica Fliss, IDEMDennis Williamson, Monroe County Health Department
CC~
John Langley, CBUJeff Lifka, Tetra Tech EM, Inc.John Bassett, AECOMMike McCann, CBSRuss Cepko, CBSMike Hessling, PSARAPatrick Kneip, PSARABP Files
TABLES
Table 1. Groundwater and Surface Water Monitoring RequirementsDuring the Monitoring Period
CBS CorporationNeal’s Landfill, Bloomington, Monroe County, Indiana
Monitoring StationLTGWMP Other Requirements/
Parameter a Frequency Comment
South Spring PCB, SS, C Monthly Qualitative or quantitativeflow estimate, if possible
North Spring PCB, SS, C Monthly Qualitative or quantitativeflow estimate, if possible
Spring Treatment Facility PCB Semimonthly Influent, Effluent andMid Carbon LocationsSampled
aparameters to be monitored: PCB=polychlorinated biphenyl; SS=total suspended solids; W=water level;C=conductivity; F=flow.
Table 3. Post-Remediation PCB ResultsNorth Spring
Neal’s Landfill, Bloomington, Indiana
Sample ID
NL5765
NL5760
NL5755
NL5750
NL5745
NL5740
NL5735
NL5730
NL5725
NL5720
NL5715
NL5708
NL5703
NL5698
NL5693
NL5688
NL5683
NL5678
NL5671
NL5666
NL5658
NL5653
NL5646
NL5641
NL5636
NL5631
NL5626
NL5621
NL5616
NL5609
NL5605
NL5607c
NL5600
NL5595
NL5590
NL5584
continued
SamplingDate
5125110
4/21/10
3/31/10
2/11/10
1/19/10
12/17/09
11/10/09
10/22/09
9/30/09
8/10/09
7/9/09
6/21/09
5/19/09
4/27/09
4/9/09
2/17/09
1/23/09
12/15/08
11/19/08
10/15/08
9/11/08
8/12/08
7/17/08
6/18/08
5/28/08
4/9/08
3/12/08
2/28/08
1/15/08
12/19/07
11/20/07
11/20/07
10/12/07
9/20/07
8/22/07
7/10/07
PCBa,
ppb
0.13 J
0.34
0.12 J
0.22 K
0.37
0.19J
0.42 K
0.52
0.72
0.41
0.32
0.31
0.18J
0.27
0.14J
0.41
0.76
1.0
1.1
0.98
0.75
0.71
0.51
0.37
0.48
0.17J
0.30
0.35
0.66
0.80
1.7
1.6
1.2
1.3
1.1
0.55
DataValidated?
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
TSS,mg/L
1
2
1
1
1
2
1
<1
4
<1
1
1
<1
2
<1
<1
4
<1
4
1
<1
2
3
1
2
<1
1
1
1
1
3
<1
6
2
2
5
Conductivity,uS/cm
426
444
400
453
471
432
498
513
628
498
462
452
391
399
393
408
527
586
617
629
608
567
551
506
446
383
410
432
50O
5O7
654
654
645
637
612
519
Temperature,deg C
12.2
11.4
11.2
10.7
10.8
11.7
12.8
13.4
14.3
13.8
13.6
12.6
11.7
11.3
11.0
10.5
10.3
11.4
12.7
14.2
14.4
13.9
13.1
12.1
11.6
11.0
10.7
10.7
11.2
11.5
13.3
13.3
14.5
14.6
14.4
13.5
Flowb,
gal/min
50
40
120
20
40
60
20
18
10
30
25
30
50
30
60
50
15
40
20
15
20
20
30
150
40
50
50
100
40
40
10
10
10
12
12
15
Table 3. Post-Remediation PCB ResultsNorth Spring
Neal’s Landfill, Bloomington, Indiana
Sample ID
NL5579
NL5572
NL5567
NL5562
NL5557
NL5551
NL5527
NL5522
NL5433
NL5428
NL5423
NL5418
NL5406
NL5395
NL5390
NL5385
NL5380
NL5375
NL5370
NL5363
NL5357
NL5252
NL5233
NL5219
NL5214
NL5207
NL5196
NL5191
NL5179
NL5174
NL5154
NL4812
NL4808
NL4580
NL4572
NL4571
continued
SamplingDate
6/13/07
5/14/07
4/9/07
3/13/07
2/23/07
1/11/07
12/15/06
11/27/06
10/10/06
9/27/06
9/8/06
8/22/06
7/18/06
6/14/06
5/22/06
4/5/06
3/6/06
2/8/06
1/16/06
12/6/05
11/18/05
10/30/05
9/30/05
8/3/05
7/21/05
6/7/05
5/3/05
4/11/05
3/8/05
2/11/05
1 / 19/05
12/16/04
11/17/04
10/6/04
9/9/04
816104
PCBa,
ppb
0.66
0.40
0.17J
0.28
<0.10
0.20
0.15J
0.40
1.0
0.81
1.1
0.55
0.45
0.51
0.27
0.12J
0.40 K
0.27
0.17J
0.74
0.68
0.83
0.78
0.78
0.92
0.46 J
0.24
0.26
0.41
0.32
0.16J
0.45
0.82
1.4
0.88
0.56
DataValidated?
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
TSS,mg/L
11
<1
<1
3
<1
1
<1
4
5
3
2
5
7
2
2
<1
2
1
<1
3
<1
3
4
<1
<1
3
<1
<1
<1
<1
<1
4
2
4
<1
3
Conductivity,uS/cm
527
481
404
425
336
403
394
499
566
555
558
533
545
512
446
371
471
471
398
508
477
565
540
525
527
476
412
395
432
402
411
479
513
591
600
530
Temperature,deg C
12.6
11.8
11.0
10.8
10.7
11.4
11.7
12.2
14.0
14.1
14.5
14.5
13.5
12.4
11.7
11.3
10.9
10.1
11.4
12.1
12.9
13.8
14.4
14.4
13.9
12.4
11.6
11.4
10.8
10.9
11.2
11.8
12.8
14.1
14.2
13.8
Flowb,
gal/min
20
60
120
75
225
150
120
50
30
20
10
12
15
40
60
70
35
60
120
90
30
10
40
25
15
50
60
80
80
70
120
30
35
15
15
15
Table 3. Post-Remediation PCB ResultsNorth Spring
Neal’s Landfill, Bloomington, Indiana
Sample ID
NL4556
NL4518
NL4500
NL4356
NL4347
NL4335
NL4223
NL4219
NL4215
NL4211
NL4207
NL4203
NL 1995
NL1985
NL1914
NL1910
NL 1906
NL 1902
NL1898
NL1888
NL1874
NL1870
NL1866
NL1861
NL1847
NL 1774
NL 1766
NL1760
NL 1702
NL 1696
NL1688
NL1683
NL 1633
NL1623
NL1617
NL1609
continued
SamplingDate
7/16/04
5/5/04
4/19/04
3/9/04
2/13/04
1/14/04
12/8/o3
11/5/03
1 o/8/03
9/9/03
8/5/03
7/9/03
6/2/03
5/14/03
4/10/03
3/17/03
2/7/o3
1/10/03
12/3/o2
11/12/02
10/lO/O2
9/4/02
8/8/02
7/17/02
6/11/02
5/21/02
4/11/02
3/14/02
2/13/02
1/22/02
1/3/02
11/15/01
10/19/01
9/14/01
8/16/01
7/27/01
PCBa,
ppb
0.43
0.26
0.35
0.2
0.34
0.42
0.35
0.86
1.2
0.67
0.75
0.68
0.66
0.18J
0.36
0.24
0.63
0.58
1.3
0.82
1.6
1.1
1.2
0.71
0.54
0.3
0.2
0.22
0.42
0.39
0.56
0.78
0.57
1.1
0.79
0.89
DataValidated?
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
TSS,mg/L
6
<1
<1
<1
<1
3
<1
<1
<1
<1
<1
8
5
<1
2
2
<1
<1
<1
2
3
3
8
<1
2
2
<1
8
3
4
2
<1
6
<1
4
7
Conductivity,uS/cm
465
420
450
400
393
438
449
570
580
524
515
532
496
392
396
388
473
453
564
441
592
564
570
543
466
410
379
357
387
472
465
512
463
521
504
531
Temperature,deg C
13.2
11.3
11.2
10.8
10.7
11.2
11.9
13.0
13.7
14.0
13.3
13.1
11.9
11.4
11.0
10.7
10.3
11.2
12.1
13.1
14.7
14.8
14.5
13.8
12.4
11.7
11.3
11.1
11.0
10.9
11.1
12.7
13.1
14.3
14.8
13.7
Flow~,
gal/min
20
40
30
lOO
lOO
50
30
lO
lO
lO
20
15
15
70
50
40
15
20
lO
15
15
lO
15
50
40
60
40
80
40
15
20
15
25
15
lO
20
Table 3. Post-Remediation PCB ResultsNorth Spring
Neal’s Landfill, Bloomington, Indiana
Sample ID
NL1601
NL1536
NL1528
NL 1522
NL1514
NL1399
NL1393
NL1333
NL1259
NL1212
NL1112
NL 1098
NL1085
aSamples were anal’
SamplingDate
6/14/01
5/15/01
4/11/01
3/21/01
2/27/01
12/21/00
10/19/00
8/15/00
6/13/00
4/14/00
2/22/00
12/18/99
11/1/99
,zed
PCBa,
ppb
<0.1 R
1.1
0.63
0.31
0.23
0.33
0.36
1.5
1.6J
0.29
0.68
2.1
1.2
DataValidated?
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
TSS,mg/L
9
15
2
<1
2
NR
5
3
3
<1
4
10
2
Conductivity,uS/cm
432
517
398
435
377
419
473
623
521
409
491
599
4O0
Temperature,deg C
12.7
12.5
11.2
10.8
10.9
11.4
13.0
14.7
13.0
11.4
10.5
12.1
14.1
Flow~,
gal/min
12
12
60
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
to a detection limit of 0.1 ppb for all PCB parameters except Aroclor 1221 (detection limit 0.2 ppbor 0.5 ppb). Other detection limits may occasionally result from non-normal sample volumes, dilutions, etc.
bF1ow estimated visually.~Duplicate sample.NA = Not applicable.NR = Not reported. ’J = Estimated value. The QA/QC data indicated an analytical bias.K = Estimated value due to QA blank contaminationR=Unusable data. QA/QC data indicated significant deficiencies in the analytical data.
Table 4. Post-remediation PCB ResultsConard’s Branch Pool by Vernal PikeNeal’s Landfill, Bloomington, Indiana
Sample ID
NL5764
NL5759
NL5754
NL5749
NL5744
NL5739
NL5734
NL5729
NL5724
NL5719
NL5714
NL5707
NL5702
NL5697
NL5692
NL5687
NL5682
NL5677
NL5670
NL5665
NL5657
NL5652
NL5645
NL5640
NL5635
NL5630
NL5625
NL5620
NL5615
NL5608
NL5604
NL5599
NL5594
NL5589
NL5583
NL5578
NL5571
NL5566
NL5561
continued
Sampling PCBa, Data TSS, Conductivity,Date ppb Validated? mg/L uS/cm
5/25110 0.089 Y 13 445
4/21/10 0.076 Y 4 483
3/31/10 0.10 Y 7 423
2/11/10 0.090 K Y 7 527
1/19/10 0.048 Y 2 519
12/17/09 0.11 ¥ 4 448
11/10/09 0.086 K Y 6 493
10/22/09 0.056 Y 2 519
9/30/09 0.046 Y 5 583
8/10/09 0.10 Y 4 487
7/9/09 0.11 Y 3 471
6/21/09 0.11 Y 9 501
5/19/09 0.14 Y 6 401
4/27/09 0.073 Y 3 424
4/9/09 0.11 Y 8 413
2/17/09 0.14 Y 7 428
1/23/09 0.077 Y 4 500
12/15/08 0.05 Y 3 537
11/19/08 0.023 Y 2 612
10/15/08 0.09 Y 1 609
9/11/08 0.076 Y 3 548
8/12/08 0.084 Y 4 548
7/17/08 0.11 Y 5 501
6/18/08 0.13 Y 4 438
5/28/08 0.11 Y 3 451
4/9/08 0.12 Y 3 420
3/12/08 0.075 Y 2 501
2/28/08 0.16 J Y 4 546
1/15/08 0.096 Y 3 521
12/19/07 0.055 Y 2 672
11/20/07 0.04 Y 2 612
10/12/07 0.051 Y 3 614
9/20/07 0.068 Y 2 539
8/22/07 0.068 Y 7 564
7/10/07 0.10 Y 17 430
6/13/07 0.077 Y 6 519
5/14/07 0.093 Y < 1 447
4/9/07 0.076 Y 4 443
3/13/07 0.087 Y 3 417
Temperature,deg C
18.4
10.6
11.6
9.1
6.4
9.2
14.7
14.5
15.7
22.7
18.5
18.8
15,8
18.2
11.6
9.9
5.3
4.7
5.1
18.9
19.7
17.7
17.9
15.6
14.4
16.8
8.5
8.4
4.1
6.7
12.4
13.1
24
24.0
27.7
19.5
22.7
12.0
17.1
gal/min
250
125
500
220
90
450
100
70
25
90
150
200
500
200
600
400
80
100
30
12
25
60
150
200
180
480
500
45O
180
160
14
10
12
25
40
50
180
280
150
Table 4. Post-remediation PCB ResultsConard’s Branch Pool by Vernal PikeNeal’s Landfill, Bloomington, Indiana
Sample ID
NL5556
NL5550
NL5526
NL5521
NL5432
NL5427
NL5422
NL5417
NL5405
NL5394
NL5389
NL5384
NL5379
NL5374
NL5369
NL5362
NL5361
NL5356
NL5251b
NL523~
NL5224
NL5223
NL5218
NL521~
NL520~
NL5200
NLS19~
NL519~
NLS18~
NL517~
NL4816
Sampling PCBa, Data TSS, Conductivity,Date ppb Validated? mg/L uS/cm
2/23/07 0.11 Y 6 403
1/I 1/07 0.10 Y 1 445
12/15/06 0.13 Y 7 446
11/27/06 0.097 Y 6 510
10/10/06 0.094 K Y 3 563
9/27/06 0.11 Y 6 559
9/8/06 0.14 K Y 6 526
8/22/06 0.070 Y 9 503
7/18/06 0.081 Y 8 547
6/14/06 0.074 Y 2 516
5/22/06 0.079 Y 4 468
4/5/06 0.10 K Y 8 418
3/6/06 0.087 K Y 1 486
2/8/06 0.15 J Y 4 471
1/16/06 0.33 Y 15 459
12/6/05 0.071 J Y 11 532
12/1/05 0.071 Y 5 506
11/18/05 0.16 J Y 8 493
10/30/05 <0.10 Y 3 554
9/30/05 0.16 J Y 5 545
8/17/05 0.083 Y < 1 525
8/10/05 0.11 J Y 5 535
8/3/05 < 0.01 Y 3 525
7/21/05 0.17 J Y 3 493
6/7/05 < 0.10 Y 4 472
5/4/05 0.037 Y < 1 467
5/3/05 < 0.10 Y < 1 454
4/11/05 0.12 J Y 2 433
3/10/05 <0.10 Y 4 480
3/8/05 0.11 J Y 4 472
12/16/04 0.12 Y 13 513
Temperature,deg C
8.0
lO.8
10.3
12.8
14.2
14.0
16.7
23.0
21.5
16.8
13.7
14.8
7.9
10.1
11.8
3.4
7.7
10.7
11.7
17.7
24.5
21.6
25.1
22.7
20.1
12.6
12.8
17.9
7.2
8.7
8.3
Flowc,
gal/min
4O0
700
350
150
50
120
45
40
40
100
400
60O
150
415a
400
90
200
350
40
80
60
40
30
50
70
245d
150
120
180
180
150
aSamples were analyzed to a detection limit of 0.01 ppb for all PCB parameters except Aroclor 1221 (detection limitof 0.02 ppb).
bAnalyzed at a detection limit of 0.1 ppb.CFlow estimated visually.dFlow calculated from readings obtained with a manual flow velocity meter.J = Estimated value. The QA/QC data indicated an analytical bias.K = Estimated value due to QA blank contamination
Table 5.Continuous Flow and Water Level MonitoringNeal’s Landfill
Monroe County, Indiana
Monitoring Station Parameter Reported Monitoring Period Instrument
Conard’s Branch Weir Water level / flow All Quarter
NL Rain Gauge Rainfall All Quarter
MW EPA-5A Water level All Quarter
In-Situ LeveITroll
EZ-Logger/tippingbucket rain gauge
In-Situ Mini-Troll
PZ-02, -03, -04, -05 Water level All Quarter Crest gauge
Date2/11/2010
10/22/2009
8/25/2009
5/31/2009
2/18/2009
11/13/200810/22/2008
9/10/2008
8/1/2008
7/18/20086/25/2008
6/6/2008
5/20/2008
4/30/2008
4/9/2008
2/13/20088/27/2007
8/3/2007
7/5/2007
6/25/2007
6/11/20075/31/2007
5/8/2007
4/20/2007
3/23/2007
3/10/20072/19/2007
2/8/2007
1 / 18/2007
1/2/2007
11/8/2006
9/28/20069/13/2006
8/22/2006
8/3/2006
7/25/2006
7/11/2006
6/12/2006
5/18/20065/2/2006
continued
Table 6. Crest Gauge DataNeal’s Landfill
Monroe County, Indiana
PZ-02o
o
2.6
2.6
2.6o
0
0
o
0o
0
o
02
o
o
o
o
oo
0
o
0
o
0o
0
o
0
0o
o
0
o
o
0
0o5
Apparent Movement (in)PZ-03
0
0
0
0
0
00
0
0
00
0
0
00
00
0
0
00
0
0
00
00
0
0
0
0
00
0
0
0
0
0
00
PZ-04
0
0
o
0
0
o
0o
0
o
0o
0
o
0
o
0o
0
o
0o
0
o
0
o
0o
o
0
o
o
0o
o
0
0
o
0o
PZ-05
0
0
0
0
0
00
0
0
00
00
0
0
00
0
0
00
00
0
0
0
00
0
0
0
0
00
0
0
0
0
00
Date4/3/2006
3/10/2006
2/28/20062/15/2006
2/1/2006
1/16/2006
1/5/2006
12/20/2005
11/2/200510/11/2005
9/19/2005
8/31/2005
8/8/20057/19/2005
6/22/2005
5/12/20055/3/2005
4/13/2005
3/25/2005
2/18/2005
2/3/200512/7/2004
11/22/2004
10/26/2004
10/7/20049/23/2004
9/10/2004
8/31/2004
8/11/2004
8/3/2004
7/13/2004
6/25/2004
6/15/20045/25/2004
5/10/2004
4/22/2004
4/13/2004
3/25/2004
3/11/20042/26/2004
continued
Table 6. Crest Gauge DataNeal’ s Landfill
Monroe County, Indiana
PZ-02
00
o
0
o
0
0o
0
2.4
0o
00o
0
o
0
-Note0
0
00
00
0
0
00
0
0
0
0
0
00
0
0
0
0
Apparent Movement (in)PZ-03
0
0
00
0
0
0
00
00
0
00
0
0
00
0
0
00
0
0
0
0
00
0
0
0
0
00
0
0
0
0
0
0
PZ-04o
0o
o
0
o
0
oo
0
o
o
oo
0
o0
o
4.4
0o
0
o
0
o
00
0
0
o
0
0o
o
0
o
o
0
0o
PZ-05
00
o
0
o
0
0o
0
o
0o
00o
0
o
4.3
NR4
0
10
0
00
0
0
0
00
0
0
0
0
00
0
0
0
0
Date2/12/2oo4
1/29/2oo4
1/15/2oo4
12/31/2oo3
12/8/2oo3
11/2o12oo311/5/2oo3
1 o/2312oo3
lO/912oo3
9/29/2oo3
9/11/2oo38/29/2oo3
8/1512oo3
8/1/2oo3
7/1712oo3
7/3/2oo3
6/19/2oo36/6/2oo3
5/19/2oo3
518/2oo3
4/23/2oo341712oo3
3/19/2oo3
3/612oo3
2/2o/2oo3
2111/2oo3112812oo3
1113/2oo3
1213o/2oo2
12/13/2oo2
1212/2oo2
11114/2oo21 o131/2oo2
lO/17/2oo2
lO13/2oo2
9/19/2oo2
9/912oo2
8/2212oo28/9/2oo2
7/2612oo2
continued
Table 6. Crest Gauge DataNeal’ s Landfill
Monroe County, Indiana
PZ-020
0
0
0
00
0
0
00
0
0
0
0
0
00
0
00
0
0
0
0
0
00
0
0
0
00
0
0
0
0
0
00
0
Apparent Movement (in)PZ-03
o
o
0
o
o
0o
0
o
0
oo
o
0
o
oo
o
o
0
o0
o
0
o
0
0o
0
o
0
-Note
-Note
-Note
-Note
-Note
-Note-Note
0.60.4
PZ-04
00
0
0
00
00
0
0
0
00
0
00
00
0
0
00
0
0
00
0
00
0
00
0
00
0
0
00
0
PZ-05oo
0
0
0
0
o
0o
0
o
0o
0
o
o
o
0o
0
o
0o
0
0
o
0
o0
0
o
0
0
oo
0
0
o
0
0
Table6. Crest Gauge DataNeal’ s Landfill
Monroe County, Indiana
Date7/11/2002
6/27/2002
6/14/2002
5/31/2002
5/16/20025/3/2002
4/18/2002
4/4/2002
3/21/2002
3/8/2002
2/8/20021/25/2002
1/9/2002
10/25/2001
10/9/2001
9/21/20019/7/2001
8/28/2001
6/14/2001
PZ-020
0
0
0
00
0
0
0
00
0
0
0
0
00
0
0
Apparent Movement (in)PZ-03 PZ-04
oo
-Note 20
0
00
00
0
00
0
0
0
0
0
PZ-05
00
00
0
0
0
2
0.25
0.6
0.5
0.751.752.5
0
3.25
2
1.754.25
4.75
4.9
2.6
2.63.25
00.75
Reinstalled
0
0o
0
o
0
o
oo
0
0
Reinstalled0
Crest gauge removed from piezometer; miniTroll instrument installed.2 No measurement possible due to jammed lock on piezometer.
3 Gauge became damp, then dried prior to inspection in such a manner as to produce an inconclusive chalk
line. Dampness most likely caused by condensation of well humidity, not an actual piezometric rise.4 No record.
Table 7. Piezometer-01 Water ElevationsNeal’s Landfill
Monroe County, Indiana
Date9/29/200310/9/200311/5/200311/20/200312/8/20031/15/20041/29/20042/12/20042/26/20043/11/20043/25/20044/13/20044/22/20045110120045/25/20046/15/20046/25/20047/13/20048/3/20048/11/20048/31/20049/10/20049/23/200410/7/200410/26/200411/22/200412/7/20042/3/2005
2/18/20054/13/20055/3/20055/12/20057/19/20058/8/20058/31/2005
9/19/2005
10/11/200511/2/2005
12/20/2005
WaterElevation
(~)772.53772.55772.58772.64772.61772.55772.52772.5772.53772.55772.47772.55772.50772.38772.41772.39772.38772.42772.42772.39772.34772.30772.25772.22772.28772.27772.40772.21772.27772.35772.19771.58772.03772.03772.09
772.06
772.03772.04
772.05
Date1/5/2006
1/16/20062/15/20062/28/20063/10/20063/29/20065/2/2006
5/18/20066/12/20067/11/20067/25/20068/3/20068/22/20069/13/200611/8/20061/2/2007
1/18/20072/8/2007
2/19/20073/10/20073/23/20074/20/20075/8/20075/31/20076/12/20076/26/20078/4/20078/27/20072/13/20086/12/20076/26/20078/4/2007
8/27/20072/13/2008
4/9/20084/30/2008
5/20/20086/6/2008
7/18/2008
WaterElevation
(~)772.22772.17772.14772.12772.14772.08772.10772.14772.07771.99771.69771.97771.94771.92771.92771.90771.90771.84771.90772.00771.98771.99772.00771.96771.96771.94771.86771.84771.82771.96771.94771.86771.84771.82
771.75771.83
771.77
771.78772.01
Date8/1/2008
9/10/2008101221200811/13/20082/18/20095/31/20098/25/200910/22/20092/11/2010
WaterElevation
(if)771.96771.95771.93771.54771.54771.36771.28771.21771.25
FIGURES
/ \/ \/
CONTINUOUS MONITORING PLOTS
(u!) Ile=tu!e~ aA!~,elnmno
G:) 0 0 0 0 0 0
(uJd6) ~o1_-I
(u!) Ileju!e~l eAp, elnu~no
(~ud6) ~Ol.-I
(Lud6) MoI-I
~ 0
(u!) Ileju!e~l aAp, elntuno
(u!) Ilej.u!eEI aA!:l.elnmno
(u!) Ile.~u!e~l eAp, elnuJnD
(~,J) uo!~,eAel:l Je~,eM
APPENDIX A
Chain-of-Custody Records
E
= i
APPENDIX B
Certificates of Analysis
CERTIFICATE OF ANALYSISService Location
]ERITAGE ENVIRONMENTAL SERVICES, LLC;OMMERCIAL LABORATORY OPERATIONS’901 W. MORRIS ST.~IDIANAPOLIS, IN 46231317)243-8304
Received
02-APR-10
Completed
08-APR-10
Printed
12-APR-10
Project Lab ID
4602 A877447
PO Number
BL0177 ..............
Sampled
31-MAR-10 10:29
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5754MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER CODE: 2226MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION SW846i3510C
AnalySt~ B. WOOD Analysis Date: 06~APR:10 instrument: PREP Test: P230.1.0
Parameter Result Det. Limit UnitsINITIAL WEIGHT OR VOLUME 2000 mL
FINAL VOLUME 1.0 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846.8082
...... Analysis Date : 06-APR, t0 17:15 Instrument: GCtECDAnalyst: K. VEST ......PCB SEPARATORY FUNNEL LiQUID-LIQUID EXT~CTION SW846-35~0C P230.t;0Prep:
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
SUMMATION OF AROCLORS
ResultBDL
BDL
BDL
0.10
BDL
BDL
BDL
BDL
82.0
0.10
Test: O301:7.0
Units0.01 ug/L
0.02 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
% Rec
0.02 ug/L
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC Sample ID: A877447 NL5754
Arochlor exhibits degradation.
TOTAL SUSPENDED SOLIDS DRIED AT 103-105 DEGREES CSM 2540 D; 19THi
Ana!yst: R. YOUNG Analysis Date: 06’APR,10 1;2:00
Parameter ResultSUSPENDED SOLIDS 7
Det. Limit UnitsI I mglL
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 4.2 C.Sample chain of custody number 68474.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,
LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.
IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWiX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 08-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
02-APR-10
Completed
08-APR-10
Printed12-APR-10
Project
4602
Lab ID
A877448
PO Number
B L0177 ..............
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5755MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER CODE: 2226MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Sampled
31-MAR-10 10:55
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL MQUID-MQUID EXTRACTION SW846-3510C
Analyst: B. WOOD Analysis Date: 06,APR-10 Instrument:PREP Test: P230.1.0
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 1000 mL
FINAL VOLUME 5.0 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846,8082
Analyst: K. VEST Analysis Date: 06~APR40 17:15 instrument: GC/ECDPrepi PCB SEPARATORY FUNN EL LIQUID-LiQUI D EXT~CTION SW846-35t0C P23011.0
Parameter Result Det. LimitPCB AROCLOR 1016 BDL
PCB AROCLOR 1221 BDL
PCB AROCLOR 1232 BDL
PCB AROCLOR 1242 0.12
PCB AROCLOR 1248 BDL
PCB AROCLOR 1254 BDL
PCB AROCLOR 1260 BDL
PCB AROCLOR 1262 BDL
SURROGATE RECOVERY
DECACH LOROBI PH ENYL (DCB) 104.0
SUMMATION OF AROCLORS J 0.12
0.10
0.20
0.10
0.10
0.10
&10
0.10
0.10
0.20
NELAC:Y
Test; O301:.7:0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
ug/L
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC Sample ID: A877448 NL5755
Arochlor exhibits degradation.
Parameter Result Def. Limit UnitsSUSPENDED SOLIDS I I I mglL
Sample Comments
BDL Below Detection Limit
J Estimated, below calibration range.
Sample was received on ice at temperature 4.2 C.Sample chain of custody number 68474.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,
LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.
IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 08-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
02-APR-10
Completed
08-APR-10
Printed
12-APR-10
Project Lab ID
4602 A877449
PO Number
B L0177 ..............
Sampled
31-MAR-10 11:00
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5756MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER CODE: 2226MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID’LIQUID EXTRACTION SW846-3510C
Analyst: B. WOOD AnalYsis Date: 06~APR~10
Parameter Result
INITIAL WEIGHT OR VOLUME 1000
FINAL VOLUME 5.0
Instrument: PREP
Det. Limit
Test: P230.1.0
Units
mL
mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846.8082
Analyst: K. VEST Analysis Date: 06-APR-t0 1:7:15Prep PCB SEPARATORY FUNNEL LIQUID,LiQUID EXTRACTION SW846-3510C P230/I.0
ParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
SUMMATION OF AROCLORS
ResultBDL
BDL
BDL
BDL
BDL
BDL
BDL
BDL
72.0
BDL
Instrument: GC/ECD
Det. Limit
0.10
0.20
0.10
0.10
0.10
&10
0.10
0.10
0.20
NELAC:Y
Test: O301.7.0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
ug/L
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
TOTAL SUSPENDED SOLIDS DRIED AT 103’105 DEGREES C SM 2540: D, 19TH ED;
Analyst: R. YOUNG Analysis Date: 06,APR~10 1:2:00
Parameter ResultSUSPENDED SOLIDS BDL
Det. Limit
Sample ID: A877449 NL5756
NELAC:Y
Units1 mg/L |
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 4.2 C.Sample chain of custody number 68474.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample results
relate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)
accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 08-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
02-APR-10
Completed
08-APR-10
Printed
2-AP R- 10
Project Lab ID
4602 A877450
PO Number
B L0177 ..............
Sampled
31-MAR-10 11:26
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample DescriptionCLIENT ID: NL5757MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER CODE: 2226MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
PCBSEPA TO FUNNELLIQUID’LIQUI x’r CTIONS 46-5t0C
Analyst: B. WOOD Analysis Date: 06-APR-10 instrument: PREP Test.: P230.1.0:
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 1000 mL
FINAL VOLUME 5.0 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846,8082 NELAC:Y
Analyst: K. VEST Analysis Date: 06-APR-10 17:15 ~strument: GC/ECD Test: O301.7.0i i
Prep: PCB SEPARATORY FUNNEE LIQUID-LIQUID EXTRACTION SW846:3510C P230:.I.0
ParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
SUMMATION OF AROCLORS
ResultBDL
BDL
BDL
0.61
BDL
BDL
BDL
BDL
102.0
0.61;
Det. Limit
0.10
&20
0.10
0.10
0.10
0.1;0
0.10
0.10
0.20
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
ug/L
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
Arochlor exhibits degradation.
Sample ID: A877450 NL5757
Analyst: R. YOUNG ASaiysis Date: 06"APR,10 12:00
Parameter Result
SUSPENDED SOLIDS 7
Det. Limit Units
1 I mg/LSample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 4.2 C.Sample chain of custody number 68474.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample results
relate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.
IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 08-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
02-APR-10
Completed
08-APR-10
Printed
12-APR-10
Project Lab ID
4602 A877451
PO NumberB L0177 ..............
Sampled
31-MAR-10 11:26
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample DescriptionCLIENT ID: NL5758MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER CODE: 2226MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
PCB SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION SW846:3510C
Analyst! B. WOOD Analysis Date: 06-APR~10 Instrument: PREP Test: P230.1.0
Parameter Result Det. Limit UnitsINITIAL WEIGHT OR VOLUME 920 mL
FINAL VOLUME 5.0 mL
PCB AROCLORS BY GAS CHROMA’rOGRAPHY/ECD SW846-8082
Analyst: ..... Analysis Date: 06-APR~10 17:15 Instrument: GC/ECDK.VESTPrep: PCB SEPA~TORY FUNNEL LIQUID-LIQUID EXTRACTION SW846,3510C P23011~0
ParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL(DCB)
SUMMATION OFAROCLORS
ResultBDL
BDL
BDL
0.67
BDL
BDL
BDL
BDL
98.0
0.67
Det. Limit
0.10
0.20
0.10
0.10
0.10
0.10
0.10
0.10
0.20
NELAC:Y
Test: O301.7:0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
ug/L
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC Sample ID: A877451 NL5758
TOTAL SUSPENDED SOLIDS DRIED AT 103~105 DEGREES C SM 2540 D, 19TH ED~ NELAO:Y
Analyst:R, YOUNG AnalySis Date: 06-APR~10 12:00 Test: G403.8.0
Parameter Result Det. Limit Units
SUSPENDED SOLIDS 8 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 4.2 C.Sample chain of custody number 68474.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)
accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 08-APR-J0
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Report To
NEILL VAUGHNCBS CORP
Received
22-APR-10
Completed
04- MAY- 10
Printed
20-MAY- 10
Lab ID
A879115
PO Number
BL-0396
Sampled
21-APR-10 09:34
2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5759MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 59870MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION SW846-3510C
Analyst: T. WATSON Analysis Date: 26-APR,10
Parameter ResultINITIAL WEIGHT OR VOLUME 1950
FINAL VOLUME 1.0
Instrument: PREP Test: P230.1.0
Det. Limit UnitsmL
mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846.8082
Analysis Date: 2ZiAPRil0 19:15Aaa!Ysti K. VEST ....PrepiPCB SEPARATORY FUNNEL ~iQUID-LIQUIDEXTRAOTION SW846-35!0C P230;:1:0
ParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0,076
BDL
E~DL
BDL
BDL
92.0
instrument: GC/ECD Test:: O301i17.0
Det. Limit
0.01
&02
0.01
0:01
0.01
0:01
0.01
0:01
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
SUMMATION OF AROCLORS
Aroclor exhibits degradation.
.076
Sample ID: A879115 NL5759
0.02 ug/L
NELAC:YTOTAL SUSPENDED SOLIDS DRIED AT 103’105 DEGREES CSM 2540: D~ 19TH ED: .....
Analysis Date: 22-APR’10 09:30 Test: G403i8i0Analyst: R. YOUNG ...........
Parameter Result Det. Limit Units
SUSPENDED SOLIDS 4 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 2.1 C.Sample chain of custody number 109466.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 29-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
22-APR-10
Completed
04-MAY-10
Printed
20-MAY-10
Lab ID
A879116
PO NumberBL-0396
Sampled
21-APR-10 09:55
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5760MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 59870MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0396
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID,LIQUID EXTRACTION SW846~3510C
Analyst: TI WATSON Analysis Date: 26-APR.10 instrument: PREP Test: P230.1:0
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 960 mL
FINAL VOLUME 5 mL
PCB AROCLORS BYGAS CHROMATOGRAPHY/ECD SW846’8082
Analyst: K~ VEST Analysis Date: 27-APR-1019:15 instrument:GC/ECD
Prep: PCB SEPARATORY FUNNEL LIQUID-LIQU D EXTRACT ON SW846-35IOC P230.1:0 ....
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0.34
BDL
BDL
BDL
BDL
106.0
0.10
0.20
0.10
0.10
0.10
0:1;0;
0.10
0.10
NELAC:Y
Test: O301.7:0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
SUMMATION OF AROCLORS
Aroclor exhibits degradation.
I0.34
Sample ID: A879116 NL5760
0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103’105 DEGREES C SM 2540 D, 19TH ED;
AnalYst: R: YOUNG AnalYsis Date: 22-APR~10 09i30
Parameter
I ResultSUSPENDED SOLIDS 2
Test: G403 &0~
Det. Limit Units/
1 mg/L J
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 2.1 C.Sample chain of custody number 109466.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 29-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Report To
NEILL VAUGHNCBS CORP
Received
22-APR-10
Completed
04-MAY-10
Printed
20-MAY-10
Lab ID
A879117
PO Number
BL-0396
Sampled
21-APR-10 10:03
2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5761MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 59870MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0396
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID.LIQUID EXTRACTION SW846,3510C
Analyst: T. WATSON Analysis Date: 26-APR-10 Instrument: PREP Test: P230.1.0
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 970 mL
FINAL VOLUME 5 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846-8082 .... NELAC:Y
Analyst: K. VEST Analysis Date: 27-APR~10 19:15 Instrument: GC/ECD Test: O301.7.0
Prep: PCB SEPARATORY FUNNEL LIQUiD~LIQUID EXTRACTION SW846-3510C 9230:’1,0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
BDL
BDL
BDL
BDL
BDL
92.0
Units0.10 ug/L
0.20 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
% Rec
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC Sample ID: A879117 NL5761
SUMMATION OFAROCLORS BDL 0:20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103i105 DEGREES C SM 2540 O, 19TH NELACI¥
Analyst! R~ YOUNG Analysis Date: 22~APR~10 09:30 Test:
Parameter Result Det. Limit Units
SUSPENDED SOLIDS BDL 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 2.1 C.Sample chain of custody number 109466.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 29-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
22-APR- 10
Completed
04-MAY-10
Printed
20-MAY- 10
Lab ID
A879118
PO Number
BL-0396
Sampled
21-APR-10 10:10
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample DescriptionCLIENT ID: NL5762MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 59870MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0396
PCB SEPARATORY FUNNEL LIQUID~LIQUID EXTRACTION SW846-3510C
Analyst: T. WA’rSON Analysis Date: 26-APR~10 Instrument: PREP Test: P230.!I0
Parameter Result Det. Limit UnitsINITIAL WEIGHT OR VOLUME 960 mL
FINAL VOLUME 5 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846,8082
Analyst: K. VES,r Analysis Date: 27~APR-10 1:9:15Prep: PCB SEPARATORY FUNNEL LIQUID,LIQUID E~RACTION SW846-3510C P230.1.0
ParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0.75
BDL
BDL
BDL
BDL
NELAC:Y
instrument: GC/ECD Test:: O301.7~0
Det. Limit Units0.10 ug/L
0.20 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
86.0 % Rec
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
SUMMATION OF AROCLORS
Aroclor exhibits degradation.
0.75
Sample ID: A879118 NL5762
0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103.105 DEGREES C SM 2540 Di 19TH ED. NELAC:¥
Analyst: R. YOUNG Ahalysis Date: 26iAPR~10 13:30 ...... Test: G403.8.0
Parameter Result Det. Limit Units
SUSPENDED SOLIDS 7 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 2.1 C.Sample chain of custody number 109466.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 29-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISReceived
22-APR-10
Lab ID
A879119Service Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Completed PO Number
04-MAY-10 BL-0396
Sampled
21-APR-10 10:10
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5763MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 59870MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0396
Printed20-MAY-10
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPA~TORY FUNNEL LIQUID-LIQUID EXTRACTION SW846-3510C
Analyst: .T. WATSON Analysis Date: 26~APR~10 Instrument: PREP "Test: P230.1~0
Parameter Result Det. Limit UnitsINITIAL WEIGHT OR VOLUME 980 mL
FINAL VOLUME 5 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846.8082 NELAC:Y
Analyst: K. VEST .... Analysis Date: 27,APR-10 19:15 Insti’ument: GC!ECD Test: O30t.7.0
Prep: PCB SEPARATORY FUNNEL EiQuID-LIQUiD EXTRACTION SW846-35!0C P230.1.0
Det. Limit UnitsParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0.71
BDL
BDL
BDL
BDL
102.0
0.10
0.20
0.10
0.10
0.10
0.10
0.10
0.10
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
Page 1 of 2
HERITAGE ENVIRONMENTAL SERVICES, LLC
SUMMATION OF AROCLORS
Aroclor exhibits degradation.
0.71
Sample lD: A879119 NL5763
0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103;’!05 DEGREES C SM2540 O, 19TH EO. NELAC:¥
Parameter Result Det. Limit UnitsSUSPENDED SOLIDS 6 1 I mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 2.1 C.Sample chain of custody number 109466.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 29-APR-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Report To
NEILL VAUGHNCBS CORP
Received
27-MAY- 10
Completed
09-JUN-10
Printed
07-JUL-10
Lab ID
A883083
PO Number
BL-0396
Sampled
25-MAY-10 13:59
2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5764MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 60038MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0396
Bill To
BETH STEIGERWALDCBS CORPORATION20 8TANWlX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPA~TORY FUN NEL LIQUID-LIQUID EXT~CTION SW846-3510C
Analyst: T. PINCKERT Analysis Date: 01-JUN~I:0 Instrument: PREP Test: P230.1~0
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 2000 mL
FINAL VOLUME 1.0 mL
PCB AROCLORS BYGAS CHROMATOGRAPHY/ECD SW846-8082
Analyst: B. WOOD A~alysis Date: 0t-JUN210 15:48 Instrument: GC/ECDPrepi PCB SEPARATORY FUNNEL LIQUID, LIQUID EXTRACTION SW846-35t0C P230.1.0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0:089
BDL
BDL
BDL
BDL
104.0
Test:
Units0.01 ug/L
0.02 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
0.01 ug/L
% Rec
Page 1 of 2
SUMMATION OF AROCLORS
Sample ID: A883083 NL5764
0’02 I ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103~’105 DEGREES C SM 2540: D, 19TH ED, NELAC:Y
Analyst~ & BOXUM Analysis Date: 01;JUN-10 13:00 Test: G403.&0
Parameter Result Det. Limit UnitsSUSPENDED SOLIDS 13 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 3 C.Sample chain of custody number 64147.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWlX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 04-JUN-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
27-MAY- 10
Completed
09-JUN-10
Printed
07-JUL-10
Lab ID
A883084
PO Number
BL-0396
Sampled
25-MA¥-10 14:03
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH PA 15222
Sample DescriptionCLIENT ID: NL5765MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 60038MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
PCB SEPARATORY FUNNEL LIQUID’LIQUID EXTRACTION SW846-3510C
Analyst: T. PINOKERT Analysis Date: 01-JUN.10 Instrumenti PREP Test: P230.1~0
Parameter Result Det. Limit UnitsINITIAL WEIGHT OR VOLUME 1000 rnL
FINAL VOLUME 5 mL
PCB AROCLORS BY GAS CH ROMATOGRAPHY/EC D SW846;8082
Analyst: B. WOOD Anaiys[s Date: 01’JUN,10 15:48 Instrumenii GC/ECD
Prep: PCB SEPA~TORY FUNNEL LIQU!D’LIQUlD E×TRAGTION SWa4e;35~0C P230:].0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0.13
BDL
BDL
BDL
BDL
124.0
0.10
0.20
0.10
0.10
0.10
0.10
0.10
0.10
NELAC:Y
Test: O30"117.0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
Page 1 of 2
Sample ID: A883084 NL5765
SUMMATION OFAROCLORS J 0.13 0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103’105 DEGREES C SM 2540 Di 19TH ED~ NELAC:¥
Analyst: S. BOXUM Anaiysis Date! 0t-JUN-10 13:00 Test: G403i8:0
Parameter Result Det. Limit Units
SUSPENDED SOLIDS 1 1 mg/L
Sample Comments
BDL Below Detection LimitJ Estimated, below calibration range.
Sample was received on ice at temperature 3 C.Sample chain of custody number 64147.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWlX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 04-JUN-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
27-MAY-10
Completed
09-JUN-10
Printed07-JUL-10
Lab ID
A883085
PO NumberBL-0396
Sampled
25-MAY-10 14:07
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5766MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 60038MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
RACTION SW846’PCB SEPARATORY FUNNEL LIQUID-LIQUID EXT 3510C
Analyst: T~ PINCKERT Analysis Date: 01-JUN~10 Instrument: PREP Test: P230,ii0
Parameter Result Det. Limit I UnitsINITIAL WEIGHT OR VOLUME 1000
t mLFINAL VOLUME 5 mL
PCB AROCLORS BY GAS CHROMA’rOG~PHY/ECD SW846,8082
Analyst: B. WOOD AnalysisDate: 01-JUN,10 15:48 Instrument: GC/ECD
Prep: PCB SEPARATORY FUNNEL LtQUtD~LIQUID EXTRACTIQN SW846.351OC P230.1~0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
BDL
BDL
BDL
BDL
BDL
116.0
0.10
0.20:
0.10
0.10
0.10
0.10
0.10
0.10
NELAC:Y
Test: O30r1.7.0
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ugtL
% Rec
Page 1 of 2
SUMMATION OF AROCLORS BDL
Sample ID: A883085 NL5766
0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT
ParameterSUSPENDED SOLIDS
103-105 DEGREES C SM 2540 D, 19TH ED., NE~C:¥
Result Det. Limit UnitsBDL I 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 3 C.Sample chain of custody number 64147.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 04-JUN-10
Page 2 of 2
ENV~R( :~N Mi!! i’,J!)\i.. SE RVICt!!!S
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Received
27-MAY-10
Completed
09-JUN-10
Printed07-JUL-10
Lab ID
A883086
PO NumberBL-0396
Sampled
25-MAY-10 14:10
Report To
NEILL VAUGHNCBS CORP2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5767MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 60038MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION SW846-3510C
Analyst: T; PINCKERT
ParameterINITIAL WEIGHT OR VOLUME
FINAL VOLUME
Analysis Date: 01-JUN-I:0
Result1000
5
Instrument: :PREP
Det. Limit
Test: P230:1:0
mLmLUnits
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846-8082 NELAC:¥
Analyst: B; WOOD Analysis Date: 01-JUN-10 15:48 InstrUment: GC/ECDTest:: O301:710Prep: PCB SEPARATORY FUNNEL LIQUID~LIQUID EXTRACTION SW846-3510C P230.1.0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR1242
PCB AROCLOR1248
PCB AROCLOR 1254
PCB AROCLOR1260
PCB AROCLOR 1262
ResultBDL
BDL
BDL
0:56
BDL
BDL
BDL
BDL
130.0
0.10
0.20
0.10
0:1;0
0.10
0~10
0.10
O: 10
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
Unitsug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
% Rec
Page 1 of 2
~*" ~ r.:]NV RONM{ZN-fT\L S{i!RV!< }ES
SUMMATION OF AROCLORS 0.56
TOTAL SUSPENDED SOLIDS DRIED AT 103"105 DEGREES C SM 2540 D; 19TH ED.
Analyst! S~ BOXUM Analysis Date! 0%JUN,10
Parameter Result Det. LimitSUSPENDED SOLIDS 6
Sample ID: A883086 NL5767
0.20 ug/L
Units/
mg/L J
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 3 C.Sample chain of custody number 64147.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 04-JUN-10
Page 2 of 2
CERTIFICATE OF ANALYSISService Location
HERITAGE ENVIRONMENTAL SERVICES, LLCCOMMERCIAL LABORATORY OPERATIONS7901 W. MORRIS ST.INDIANAPOLIS, IN 46231(317)243-8304
Report To
NEILL VAUGHNCBS CORP
Received
27-MAY-10
Completed
09-JUN-10
Printed
07-JUL-10
Lab ID
A883087
PO NumberBL-0396
Sampled
25-MAY-10 14:10
2002 WEST VERNAL PIKEBLOOMINGTON, IN 47404
CLIENT ID: NL5768MATRIX TYPE: NON-SPECIFIC WATERSUBMITTER: 2226 - CBS CORPORATIONPROJECT NAME: CBS CORPDATA PACKAGE #: 60038MATRIX: WSLOCATION: NEAL’S LANDFILLBLANKET ORDER RELEASE: BL0177
Bill To
BETH STEIGERWALDCBS CORPORATION20 STANWIX STREET 10TH FLOORPITTSBURGH, PA 15222
Sample Description
PCB SEPARATORY FUNNEL LIQUIDiLIQUID EXTRACTION SW846~3510C
Analyst: T. PINCKERT Analysis DateI Ol-JUN-10 Instrument!PREP Test: P23&1:0
Parameter Result Det. Limit Units
INITIAL WEIGHT OR VOLUME 1000 mL
FINAL VOLUME 5 mL
PCB AROCLORS BY GAS CHROMATOGRAPHY/ECD SW846-8082
Analyst: B. WOOD Analysis Date: 0t-JUN-t0 i5:48 Instrument: GC/ECD Test:: 030117.0
PieP: PCB SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION SW846-35i0C P230.1.0
Det. LimitParameterPCB AROCLOR 1016
PCB AROCLOR 1221
PCB AROCLOR 1232
PCB AROCLOR 1242
PCB AROCLOR 1248
PCB AROCLOR 1254
PCB AROCLOR 1260
PCB AROCLOR 1262
SURROGATE RECOVERY
DECACHLOROBIPHENYL (DCB)
ResultBDL
BDL
BDL
0.55
BDL
BDL
BDL
BDL
120.0
Units0.10 ug/L
0.20 ug/L
0.10 ug/L
0:10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
0.10 ug/L
% Rec
Page 1 of 2
SUMMATION OF AROCLORS
Sample ID: A883087 NL5768
0.20 ug/L
TOTAL SUSPENDED SOLIDS DRIED AT 103:105 DEGREES C SM 2540 D, 19TH EDi NELAC!YAnalyst: S~ BOXUM Analysis Date: 01-JUN~10 13:00 Test: G403.8i01
Parameter Result Det. Limit Units
SUSPENDED SOLIDS 6 1 mg/L
Sample Comments
BDL Below Detection Limit
Sample was received on ice at temperature 3 C.Sample chain of custody number 64147.
This Certificate shall not be reproduced, except in full, without the written approval of the lab. The sample resultsrelate only to the analytes of interest tested or to the sample as received by the lab. Heritage Environmental Services,LLC certifies that the test results indicated as NELAC (National Environmental Laboratory Accreditation Conference)accredited (Yes for NELAC) meet all requirements of NELAC and Illinois EPA Part 186 unless otherwise explained orjustified as to the the exact nature of the deviations.IL ELAP / NELAP Accreditation # 100401 Indiana SDWA Lab Accred. No. C-49-01
Additional copies of this report sent to:
RUSS CEPKO, CBS CORP - NATIONAL CITY CENTER20 STANWIX STREET 10TH FLOOR, PITTSBURG, PA 15222-1384
Approved by: SCOTT BRYAN 04-JUN-10
Page 2 of 2
APPENDIX C
Data Validation
Validation ResultsMarch 2010
Neal’s Landfill GWM Samples
1. Validation of the following samples has been completed:
NL 5754-NL5758
2. Validation was performed per the requirements for level 4 data in the project QAPjP. This includes acheck for; Holding Time, Calibration, Blank Contamination, Precision, Accuracy, and Accuracy ofNominal Reporting Limits against method requirements.
3. Based on this review, no data qualifications are recommended.
4. The QAPjP requires an assessment of the overall data quality with respect to Precision, Accuracy,Representativeness, Completeness and Comparability (PARCC).
Precision and accuracy: Precision and accuracy were accessed by reviewing the labperformance on lab spiked samples, lab spike duplicates and field duplicates. Allrequirements were met.
Representativeness: The representativeness requirement involves an assessment of thefield sampling and lab analytical techniques. The fields sampling locations andtechniques as well as lab procedures were in accordance with the approved samplingplan and QAPjP. Therefore the representativeness requirements were met.
Completeness: The completeness goal for the project was for all project data to be 90%accepted. Completeness is calculated by dividing the total number of acceptableanalyses by the total performed. An acceptable analysis is defined as one that conformedto QC protocols and is not rejected. All these analyses were accepted. The projectcompleteness goal has been met to date.
Comparability: All the samples taken, analyzed and validated by CBS were taken byCBS or it’s contractors sampling crews using the same procedures as previous samples atthis location. These samples were analyzed by Heritage Labs. Care should be takenwhen attempting to trend Heritage sample results with other labs using slightly differentprocedures. Overall these results should be directly comparable to other Heritage labresults from these locations.
Overall, the main objective of the sampling event was to determine if PCBs are present at a concentrationof 0.1 ppb or more (0.01 ppb for CB Pool VP). This data is of sufficient quality to satisfy this goal asestimates.
O:LLEA\EnvironmentalkBloomington\SHAREDIR\BP validation reports\validation-gwm qtrly report-NL Mar 10.doc 12/6/2010
Validation ResultsApril 2010
Neal’s Landfill GWM Samples
1. Validation of the following samples has been completed:
NL 5759-NL5763
2. Validation was performed per the requirements for level 4 data in the project QAPjP. This includes acheck for; Holding Time, Calibration, Blank Contamination, Precision, Accuracy, and Accuracy ofNominal Reporting Limits against method requirements.
3. Based on this review, no data qualifications are recommended.
4. The QAPjP requires an assessment of the overall data quality with respect to Precision, Accuracy,Representativeness, Completeness and Comparability (PARCC).
Precision and accuracy: Precision and accuracy were accessed by reviewing the labperformance on lab spiked samples, lab spike duplicates and field duplicates. Allrequirements were met.
Representativeness: The representativeness requirement involves an assessment of thefield sampling and lab analytical techniques. The fields sampling locations andtechniques as well as lab procedures were in accordance with the approved samplingplan and QAPjP. Therefore the representativeness requirements were met.
Completeness: The completeness goal for the project was for all project data to be 90%accepted. Completeness is calculated by dividing the total number of acceptableanalyses by the total performed. An acceptable analysis is defined as one that conformedto QC protocols and is not rejected. All these analyses were accepted. The projectcompleteness goal has been met to date.
Comparability: All the samples taken, analyzed and validated by CBS were taken byCBS or it’s contractors sampling crews using the same procedures as previous samples atthis location. These samples were analyzed by Heritage Labs. Care should be takenwhen attempting to trend Heritage sample results with other labs using slightly differentprocedures. Overall these results should be directly comparable to other Heritage labresults from these locations.
Overall, the main objective of the sampling event was to determine if PCBs are present at a concentrationof 0.1 ppb or more (0.01 ppb for CB Pool VP). This data is of sufficient quality to satisfy this goal asestimates.
OALEA~Environmental\Bloomington\SHAREDIRkl3P validation reports\validation-gwm qtrly report-NL Apr 10.doc 12/6/2010
Validation ResultsMay 2010
Neal’s Landfill GWM Samples
1. Validation of the following samples has been completed:
NL 5764-NL5768
2. Validation was performed per the requirements for level 4 data in the project QAPjP. This includes acheck for; Holding Time, Calibration, Blank Contamination, Precision, Accuracy, and Accuracy ofNominal Reporting Limits against method requirements.
3. Based on this review, no data qualifications are recommended.
4. The QAPjP requires an assessment of the overall data quality with respect to Precision, Accuracy,Representativeness, ComPleteness and Comparability (PARCC).
Precision and accuracy: Precision and accuracy were accessed by reviewing the labperformance on lab spiked samples, lab spike duplicates and field duplicates. Allrequirements were met.
Representativeness: The representativeness requirement involves an assessment of thefield sampling and lab analytical techniques. The fields sampling locations andtechniques as well as lab procedures were in accordance with the approved samplingplan and QAPjP. Therefore the representativeness requirements were met.
Completeness: The completeness goal for the project was for all project data to be 90%accepted. Completeness is calculated by dividing the total number of acceptableanalyses by the total performed. An acceptable analysis is defined as one that conformedto QC protocols and is not rejected. All these analyses were accepted. The projectcompleteness goal has been met to date.
Comparability: All the samples taken, analyzed and validated by CBS were taken byCBS or it’s contractors sampling crews using the same procedures as previous samples atthis location. These samples were analyzed by Heritage Labs. Care should be takenwhen attempting to trend Heritage sample results with other labs using slightly differentprocedures. Overall these results should be directly comparable to other Heritage labresults from these locations.
Overall, the main objective of the sampling event was to determine if PCBs are present at a concentrationof 0.1 ppb or more (0.01 ppb for CB Pool YP). This data is of sufficient quality to satisfy this goal asestimates.
OALEA\Environmental~Bloomington\SHAREDIR’d3P validation reports\validation-gwm qtrly report-NL May 10.doc12/6/2010
APPENDIX D
Instrument Maintenance Log
Neal’s Landfill Q2 2010 Instrument Maintenance Log
Conard’s Branch Weir:Instrument
Level Troll #113729
CBR RaM Gauge:InstrumentEZLogger
MW-5a:Instrument
mini-Troll #7785
Date3/24/20105/10/20105/26/2010
DateAll quarter
Date3/16/20105/10/20105/26/2010
No re-index needed.No re-index needed.No re-index needed.
Action
ActionEZLogger operated properly during the Fourth Quarter.
Re-indexed by 0.105’Re-indexed by 0.03’Re-indexed by 0.01’
Action
Recommended