View
236
Download
0
Category
Preview:
Citation preview
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
1/32
HiPath 3000/5000
Version 4.0
Getting Started
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
2/32
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
3/32
GetstartedTOC.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 0-1
For internal distribution only Contents
Contents 0
1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2 HiPath 3000 V4.0 Standalone IP System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
3 HiPath 3000 V4.0 Networked IP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
4 HiPath 5000 RSM V4.0 Multi-Node IP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z-1
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
4/32
Contents For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
0-2 HiPath 3000/5000 V4.0, Getting Started
GetstartedTOC.fm
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
5/32
intro.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 1-1
For internal distribution only Introduction
1 Introduction
HiPath 3000/5000 V4.0 is a highly scalable communications system designed for both small
and medium sized companies as well as for extensive Enterprise networks. HiPath 3000/5000V4.0 is available in various configurations and variants – from straightforward standalone sys-tems with a small number of stations through to centrally administrated networks with 64 nodesand up to 2000 workpoint clients. The system architecture avails of the advantages of distrib-uted systems to spread the load placed on individual components and to achieve optimal per-formance.
HiPath 3000/5000 V4.0 is available in the following four basic variants:
● HiPath 3000 V4.0 Standalone IP System:The standalone system is based on Euro-ISDN for connecting analog workpoint clients,
digital workpoint clients (such as optiPoint 500, optiPoint 600) and IP-based workpoint cli-ents (such as optiPoint 400 and optiClient 130).
● HiPath 3000 V4.0 Networked IP System:The networked system is a network of several HiPath 3000 V4.0 (nodes) networked over IP
● HiPath 5000 RSM V4.0 Multi-Node IP System:The Multi-Node system consists of several HiPath 3000 V4.0 (nodes) networked over IPwith a central HiPath 5000 RSM server. HiPath 5000 RSM (Real-time Service Manager) isbased on the Windows 2000 server and features open architecture which permits the im-plementation of different scenarios and individual capacity limits. The entire system is cen-trally administrated via the HiPath 5000 RSM server.
● HiPath 3000/5000 V4.0 Distributed Architecture:This is a HiPath 5000 RSM V4.0 Multi-Node IP System with a central HiPath 5000 RSMserver and an additional applications server.
>A general introduction to the HiPath 3000/5000 family of products can be found● in the System Description and● in the Service Manual of the HiPath 3000/5000 V4.0. These documents also contain detailed informationon system installation and startup.
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
6/32
Introduction For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
1-2 HiPath 3000/5000 V4.0, Getting Started
intro.fm
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
7/32
IP_standalone.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 2-1
For internal distribution only HiPath 3000 V4.0 Standalone IP System
2 HiPath 3000 V4.0 Standalone IP System
Overview
HiPath 3000 V4.0 IP enables mixed mode operation with analog workpoint clients, digital work-point clients (such as optiPoint 500 and optiPoint 600) and IP-based workpoint clients (suchas optiPoint 400 and optiClient 130).
LAN/IP
IP phones, e.g.optiPoint 400
optiClient 130,optiClient Atten-dant
HiPath 3000incl. HG1500
HiPath Cordless integrated
HiPath applicationserver, e.g.HiPath XpressionsHiPath ProCenterSimplyPhone,...
UP0/E phones, e.g.optiPoint 500/600
PSTN/ISDN
Analog phones/faxes
HiPath Wireless
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
8/32
HiPath 3000 V4.0 Standalone IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
2-2 HiPath 3000/5000 V4.0, Getting Started
IP_standalone.fm
Important Information
2.1 Important Information
This document contains brief installation and startup instructions for a HiPath 3000 with aHG1500 module. It is intended for trained service personnel who want a brief overview of the
chronological sequence of startup activities.
The following points must be performed or clarified before a HiPath 3000 system is installedand started up. Cross references to the associated documentation provide further details. If youhave these instructions as an electronic document (Help), click the blue links and you will beforwarded to the corresponding documentation.
Subject Description Detailedinformation
Safety notes Please read the relevant safety notes on installing, upgrad-ing and starting HiPath 3000.
HiPath 3000/5000Service Manual
Delivery docu-ments
Compare items delivered with the units listed in the deliverydocuments.Were all ordered items delivered?
-
Complete-ness/integrity
Test unit integrity.Are there signs of transport damage?
-
Licensing Is all the necessary information (for example the MAC ID ofthe first HiPath HG 1500 and the MAC ID of all other HiPathHG 1500 systems, customer number, contract number andpacking slip number) available for the post Licensing of the
features, IP workpoint clients, B channels and TAPI licencesordered? Is there Internet access for licensing?
Requirementsspecifications,Licensing docu-ment,
HiPath 3000/5000Service Manual
Licensing serverURL:http://cls.icn.sie-mens.de
Require-ments specifi-cations
Are the requirements specifications agreed with the custom-er available and do they contain all the necessary data?Is the data complete or is further information required?
-
Numbering
plan
Has a numbering plan been developed in line with customer
requirements?Refer if neces-
sary to the Re-quirements speci-fications
Installationsite conditions
Does the installation site meet all necessary requirements interms of surroundings and power supply?
HiPath 3000/5000Service Manual
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
9/32
IP_standalone.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 2-3
For internal distribution only HiPath 3000 V4.0 Standalone IP System
Important Information
Customer
LAN
Does the customer LAN meet the requirements for Voice
over IP? Has a network analysis been performed? Are theresults available?
Requirements
specifications,
HiPath 3000/5000Service Manual
Administration HiPath 3000 is configured by means of the HiPath 3000/ 5000 Manager E service tool. To configure the HG1500module, HiPath 3000 Manager I is required. The softwareshould be available on the technician’s service laptop orshould be installed on the stationary PC at the customer site(in agreement with the customer). V.24 or Ethernet interfac-es are used for connecting to the HiPath 3000 system.
-
Subject Description Detailedinformation
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
10/32
HiPath 3000 V4.0 Standalone IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
2-4 HiPath 3000/5000 V4.0, Getting Started
IP_standalone.fm
Step by Step Startup
2.2 Step by Step Startup
Perform the steps described below in chronological order to start up a HiPath 3000 IP systemwith a HG1500 module. Each subject has a cross reference to relevant documentation provid-
ing further details. If you have these instructions as an electronic document (Help), click theblue links and you will be forwarded to the corresponding documentation.
Status Activity/description Detailedinformation
1. Installing the hardware
Mounting/installing the HiPath 3000 HiPath 3000/5000Service Manual
Mounting and installing the client PCs, application server PC and- if necessary - switches and routers
Mounting, installing and cabling of workpoint clients on a system-specific basis
HiPath 3000/5000Service Manual
Connecting components to the customer LAN HG 1500 Adminis-tration Manual
Status:HiPath 3000 and the workpoint clients in use are located at theirinstallation sites and are physically connected to the customernetwork.
-
2. Installing additional HiPath 3000 modules
The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.
HiPath 3000/5000Service Manual
Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual
3. Starting up the HiPath 3000
Connect the system to the power source. HiPath 3000/5000Service Manual
Perform country initialization, if necessary. HiPath 3000/5000Service Manual
Enter the system call number. HiPath 3000/5000Service Manual
Perform a quick check. HiPath 3000/5000Service Manual
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
11/32
IP_standalone.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 2-5
For internal distribution only HiPath 3000 V4.0 Standalone IP System
Step by Step Startup
Status:HiPath 3000 has been started and is recognizing the workpointclients.
4. Assigning an IP address (for the HG1500 module and HiPath 3000)
Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.
-
System integration in a LAN:Perform initial configuration (assign the IP address of the LAN
network interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.
HG 1500 Adminis-tration Manual
For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .
Assign an IP address and a subnet mask (IP network mask) un-der Settings | Network Interface | Network Interface | LAN
Restore the CDB via the menuFile | Transfer customer database to LAN card.
Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerEFile | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic settings | IP Access
HiPath 3000/5000Manager E
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
12/32
HiPath 3000 V4.0 Standalone IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
2-6 HiPath 3000/5000 V4.0, Getting Started
IP_standalone.fm
Step by Step Startup
5. Configuring the IP clients
Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerE.File | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Configure the IP stations and lines via System Status | System-wide | Cards | Software Expansion | Module Configuration |HXGM Configuration.
HiPath 3000/5000Manager E
Note:“SystemClients” for optiPoint IP and optiClient
“So-Stations” for H.323 clients and VCAPI stations
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status:The HiPath 3000 IP stations can now be administrated.
-
6. Further configuration
The following important parameters must then beconfigured, for example via HiPath 3000/5000 Manager E:
Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient
HiPath 3000/5000Manager E
TrunksSettings | Lines/networking | Trunks
HiPath 3000/5000Manager E
RoutesSettings | Lines/Networking | Routes
HiPath 3000/5000Manager E
Class of Services
Settings | Least Cost Routing | Class of ServicesHiPath 3000/5000
Manager E
Call numbersSettings | Set up Station
HiPath 3000/5000Manager E
LCRSettings | Least Cost Routing
HiPath 3000/5000Manager E
Customer-specific system programming HiPath 3000/5000Service Manual
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
13/32
IP_Network.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 3-1
For internal distribution only HiPath 3000 V4.0 Networked IP System
3 HiPath 3000 V4.0 Networked IP System
Overview
HiPath 3000 V4.0 Networked IP enables mixed mode operation with analog workpoint clients,digital workpoint clients (such as optiPoint 500 and optiPoint 600) and IP-based workpoint cli-ents (such as optiPoint 400 and optiClient 130). It also makes it possible to network severalnodes over IP.
LAN/IP
IP phones, e.g.optiPoint 400
optiClient 130,optiClient Atten-
dant
HiPath 3000incl. HG1500
HiPath Cordless integrated
HiPath applicationserver, e.g.HiPath XpressionsHiPath ProCenterSimplyPhone,...
UP0/E phones, e.g.optiPoint 500/600
PSTN/ISDN
Analog phones/faxes
HiPath Wireless
PSTN/ISDN
UP0/E phones, e.g.optiPoint 500/600
HiPath 3000incl. HG1500
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
14/32
HiPath 3000 V4.0 Networked IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
3-2 HiPath 3000/5000 V4.0, Getting Started
IP_Network.fm
Important Information
3.1 Important Information
This document contains brief installation and startup instructions for a HiPath 3000 with aHG1500 module. It is intended for trained service personnel who want a brief overview of the
chronological sequence of startup activities.
The following points must be performed or clarified before a HiPath 3000 system is installedand started up. Cross references to the associated documentation provide further details. If youhave these instructions as an electronic document (Help), click the blue links and you will beforwarded to the corresponding documentation.
Subject Description Detailedinformation
Safety notes Please read the relevant safety notes on installing, upgradingand starting HiPath 3000 systems.
HiPath 3000/5000Service Manual
Deliverydocuments
Compare items delivered with the units listed in the deliverydocuments. Were all ordered items delivered?
-
Complete-ness/integri-ty
Test unit integrity. Are there signs of transport damage? -
Licensing Is all the necessary information (for example the MAC ID of thefirst HiPath HG 1500 in the HiPath 3000 with the lowest nodeID and the MAC ID of all other HiPath HG 1500 systems, cus-tomer number, contract number and packing slip number)
available for the post Licensing of the features, IP workpoint cli-ents, B channels and TAPI licences ordered? Is there Internetaccess for licensing?
Requirementsspecifications,Licensing docu-ment,
HiPath 3000/5000Service Manual
Licensing serverURL:http://cls.icn.sie-mens.de
Require-ments spec-ifications
Are the requirements specifications agreed with the customeravailable and do they contain all the necessary data? Is thedata complete or is further information required?
-
Numbering
plan
Has a numbering plan been developed in line with customer
requirements?Refer if necessary
to the Require-ments specifica-tions
Installationsite condi-tions
Does the installation site meet all necessary requirements interms of surroundings and power supply?
HiPath 3000/5000Service Manual
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
15/32
IP_Network.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 3-3
For internal distribution only HiPath 3000 V4.0 Networked IP System
Important Information
Customer
LAN
Does the customer LAN meet the requirements for Voice over
IP? Has a network analysis been performed? Are the resultsavailable?
Requirements
specifications,
HiPath 3000/5000Service Manual
Administra-tion
HiPath 3000 is configured by means of theHiPath 3000 5000 Manager E service tool. To configure theHG1500 module, HiPath 3000 Manager I is required. The soft-ware should be available on the technician’s service laptop orshould be installed on the stationary PC at the customer site(in agreement with the customer). V.24 or Ethernet interfacesare used for connecting to the HiPath 3000 system.
-
Subject Description Detailedinformation
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
16/32
HiPath 3000 V4.0 Networked IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
3-4 HiPath 3000/5000 V4.0, Getting Started
IP_Network.fm
Step by Step Startup
3.2 Step by Step Startup
Perform the steps described below in chronological order to start up a HiPath 3000 systemwith a HG1500 module. Each subject has a cross reference to relevant documentation provid-
ing further details. If you have these instructions as an electronic document (Help), click theblue links and you will be forwarded to the corresponding documentation.
Status Activity/description Detailedinformation
1. Installing the hardware
Mounting/installing the HiPath 3000 HiPath 3000/5000Service Manual
Mounting and installing the client PCs, application server PC and- if necessary - switches and routers
Mounting, installing and cabling of workpoint clients on a system-specific basis
HiPath 3000/5000Service Manual
Connecting components to the customer LAN HG 1500 Adminis-tration Manual
Status:HiPath 3000 and the workpoint clients in use are located at theirinstallation sites and are physically connected to the customernetwork.
-
2. Installing additional HiPath 3000 modules
The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.
HiPath 3000/5000Service Manual
Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual
3. Starting up the HiPath 3000
Connect the system to the power source. HiPath 3000/5000Service Manual
Perform country initialization, if necessary. HiPath 3000/5000Service Manual
Enter the system call number. HiPath 3000/5000Service Manual
Perform a quick check. HiPath 3000/5000Service Manual
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
17/32
IP_Network.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 3-5
For internal distribution only HiPath 3000 V4.0 Networked IP System
Step by Step Startup
Status:HiPath 3000 has been started and is recognizing the workpoint cli-ents.
4. Assigning an IP address (for the HG1500 module and HiPath 3000)
Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.
-
System integration in a LAN:Perform initial configuration (assign the IP address of the LAN
network interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.
HG 1500 Adminis-tration Manual
For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .
Assign an IP address and a subnet mask (IP network mask) underSettings | Network Interfaces | Network Interfaces | LAN
Restore the CDB via the menuFile | Transfer customer database to LAN card.
Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerEFile | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic settings | IP Access
HiPath 3000/5000Manager E
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
18/32
HiPath 3000 V4.0 Networked IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
3-6 HiPath 3000/5000 V4.0, Getting Started
IP_Network.fm
Step by Step Startup
5. Configuring the IP clients
Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerE.File | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Configure the IP stations and lines via System Status | System-wide | Cards | Software Expansion | Module Configuration |HXGM Configuration.
HiPath 3000/5000Manager E
Note:“SystemClients” for optiPoint IP and optiClient
“"So-Stations” for H.323 clients and VCAPI stations
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status:The HiPath 3000 IP stations and lines can now be administrated.
-
6. Further configuration
The following important parameters must then beconfigured, for example via HiPath 3000/5000 Manager E:
Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient
HiPath 3000/5000Manager E
TrunksSettings | Lines/Networking | Trunks
HiPath 3000/5000Manager E
RoutesSettings | Lines/Networking | Routes
HiPath 3000/5000Manager E
Class of Services
Settings | Least Cost Routing | Class of ServicesHiPath 3000/5000
Manager E
Call numbersSettings | Set up Station
HiPath 3000/5000Manager E
LCRSettings | Least Cost Routing
HiPath 3000/5000Manager E
Customer-specific system programming HiPath 3000/5000Service Manual
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
19/32
verbund.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 4-1
For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System
4 HiPath 5000 RSM V4.0 Multi-Node IP System
Overview
HiPath 5000 RSM V4.0 Multi-Node System is a network of several IP-networked nodes (HiPath3000). It is centrally administrated via the HiPath 5000 RSM server, which also supports othercentral applications.
LAN/IP
HiPath 5000 RSMincl. Feature Server, HiPathManager E/C/I and applica-tions (with HiPath Xpres-sions, HiPath ProCenter,
HiPath SimplyPhone, etc.)
IP phones, e.g.optiPoint 400
optiClient 130,optiClient Attendant
HiPath 3000incl. HG1500
HiPath Cordless integrated
HiPath applications server,for example with HiPathXpressions, HiPath Pro-Center, HiPath Simply-Phone, etc. (only for Hi-Path 3000/5000 distributed
architecture)
UP0/E phones, e.g.
optiPoint 500/600
PSTN/ISDN
Analog phones/faxes
HiPath Wireless
PSTN/ISDN
UP0/E phones, e.g.optiPoint 500/600
HiPath 3000incl. HG1500
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
20/32
HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
4-2 HiPath 3000/5000 V4.0, Getting Started
verbund.fm
Important Information
4.1 Important Information
This document contains brief installation and startup instructions for a HiPath 3000 networkwith a HiPath 5000 RSM server PC. It is intended for trained service personnel who want a
brief overview of the chronological sequence of startup and configuration activities.
The following points must be performed or clarified before a HiPath 3000/5000 network is in-stalled and started up. Cross references to the associated documentation provide further de-tails. If you have these instructions as an electronic document (Help), click the blue links andyou will be forwarded to the corresponding documentation.
Subject Description Detailedinformation
Safety notes Please read the relevant safety notes on installing, upgradingand startingHiPath 3000/5000 systems.
HiPath 3000/5000Service Manual
Deliverydocuments
Compare items delivered with the units listed in the deliverydocuments. Were all ordered items delivered?
-HiPath 3000/5000Service Manual
Complete-ness/integri-ty
Test unit integrity. Are there signs of transport damage? -
Licensing Is all the necessary information (such as the MAC ID of thefirst HiPath HG 1500 and the MAC ID of the HiPath 3000 CB(Control Board) with the lowest node ID as well as the MACID of all other HiPath HG 1500 systems, customer number,contract number and packing slip number) available for thepost licensing of the features, IP workpoint clients, B chan-nels, TAPI licences ordered and the feature server? Is thereInternet access for licensing?Note:The evaluation time for the Feature Server expires after a pe-riod of five days. The relevant license must be entered withinthis time.
Requirementsspecifications,Licensing docu-ment,
HiPath 3000/5000Service Manual
Licensing serverURL:http://cls.icn.sie-mens.de
Require-ments speci-fications
Are the requirements specifications agreed with the custom-er available and do they contain all the necessary data? Isthe data complete or is further information required?
-
Numberingplan
Has a numbering plan been developed in line with customerrequirements?
Refer if necessaryto the require-ments specifica-tions
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
21/32
verbund.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 4-3
For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System
Important Information
Installation
site condi-tions
Does the installation site meet all necessary requirements in
terms of surroundings and power supply?
HiPath 3000/5000
Service Manual
CustomerLAN
Does the customer LAN meet the requirements for Voiceover IP? Has a network analysis been performed? Are the re-sults available?
Requirementsspecifications,
HiPath 3000/5000Service Manual
Administra-tion
The HiPath 3000 5000 Manager E and HiPath5000 3000 Manager I service tools are required for setting upand configuring the entire system. The software should beavailable on the technician’s service laptop or should be in-stalled on the HiPath 5000 RSM Feature Server for centraladministration. You can install both of these programs fromCD 1 via the master setup. V.24 or Ethernet interfaces areused for connecting to the HiPath 3000/5000 system.
-
Subject Description Detailedinformation
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
22/32
HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
4-4 HiPath 3000/5000 V4.0, Getting Started
verbund.fm
Step by Step Startup
4.2 Step by Step Startup
Perform the steps described below in chronological order to start up a HiPath 3000 withAllServe V4.0. Each subject has a cross reference to relevant documentation providing further
details. If you have these instructions as an electronic document (Help), click the blue links andyou will be forwarded to the corresponding documentation.
Status Activity/description Detailedinformation
1. Installing the hardware
Mounting/installing the HiPath 3000 (nodes) HiPath 3000/5000Service Manual
Mounting and installing the HiPath 5000 Feature Server, clientPCs and - if necessary - switches and routers
HiPath 3000/5000Service Manual
Mounting, installing and cabling of workpoint clients on a system-specific basis
HiPath 3000/5000Service Manual
Connecting components to the customer LAN HG 1500 Adminis-tration Manual
Status:The HiPath 3000 nodes, server and workpoint clients are locatedat their installation sites and are physically connected to the cus-tomer network.
-
2. Installing additional HiPath 3000 modules
The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.
HiPath 3000/5000Service Manual
Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
23/32
verbund.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 4-5
For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System
Step by Step Startup
3. Starting up HiPath 3000
Connect the system to the power source. HiPath 3000/5000Service Manual
Perform country initialization, if necessary. HiPath 3000/5000Service Manual
Enter the system call number. HiPath 3000/5000Service Manual
Perform a quick check. HiPath 3000/5000Service Manual
Status:The HiPath 3000 have been started and are recognizing the work-point clients.
-
4. HiPath 5000 RSM Feature Server installation
Install all marketed components using master setup. HiPath 3000/5000Service Manual
Note:During installation, perform only basic configuration for the re-spective components when prompted. Once installation is com-
plete, the user, TAPI lines, clients and B channels should also beconfigured.
Install the HiPath3000/5000 Manager E and the HiPath 3000Manager I via the master setup.
HiPath 3000/5000Service Manual
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
24/32
HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
4-6 HiPath 3000/5000 V4.0, Getting Started
verbund.fm
Step by Step Startup
5. Assigning an IP address (for the HG1500 module and HiPath 3000 systems)
Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.
-
System integration in a LAN:Perform initial configuration (assign the IP address of the LANnetwork interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.
HG 1500 Adminis-tration Manual
For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .
Assign an IP address and a subnet mask (IP network mask) un-der Settings | Network Interface | Network Interface | LAN
Restore the CDB via the menuFile | Transfer customer database to LAN card.
Load every available HiPath 3000 node CDB one after the otherusing HiPath 3000/5000 Manager E.File | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic Settings | IP Access
HiPath 3000/5000Manager E
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
25/32
verbund.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 4-7
For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System
Step by Step Startup
6. Configuring Feature Server functionality (preparing HiPath 3000 nodes for the net-work)
Load every available HiPath 3000 node CDB one after the otherusing HiPath 3000/5000 Manager E.File | Transfer | Communication | System PC
HiPath 3000/5000Manager E
Activate the HiPath 5000 RSM functionality(enter the unique node ID and server IP address for HiPath 3000).Settings | Network | HiPath 5000 RSM Parameters
HiPath 3000/5000Manager E
Configure the IP stations and lines via
System Status | System-wide | Cards | Software Expansion |Module Configuration | HXGM Configuration:“SystemClients” for optiPoint IP and optiClient“So-Stations” for H.323 clients and VCAPI stations
HiPath 3000/5000
Manager E
Note:If you are setting up IP lines, use Settings | Network | HiPath5000 Parameters to allow access to the HG1500 by the HiPath5000 server.
HiPath 3000/5000Manager E
Save the CDB.File | Save
HiPath 3000/5000Manager E
Restore the data to the system.File | Transfer | Communication | PC System
HiPath 3000/5000Manager E
Status:All HiPath 3000 systems can now be administered via the networkand the IP stations and trunks can be set up.
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
26/32
HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
4-8 HiPath 3000/5000 V4.0, Getting Started
verbund.fm
Step by Step Startup
7. Merging of HiPath 3000 (nodes)
Load the default data from the HiPath 5000 RSM Server.
Then select the appropriate server under File | HiPath 5000 RSM| Transfer | HiPath 5000 RSM Server via the Search button.Then click Server - Manager.
Add new nodes (read out the CDB data of the respective nodes;repeat this process for each of the available nodes beginning withthe node that has the shortest node ID).
File | HiPath 5000 RSM | New | HiPath 3000
HiPath 3000/5000Manager E
Transfer the central database CDB by selectingFile | HiPath 5000 RSM | Transfer | HiPath 5000 RSM Server |Add Node
HiPath 3000/5000Manager E
If the HG1500 is not recognized by the Feature Server, reset allmodules selected as gateways via HiPath 3000 Manager I (or al-ternatively reset the system).
HG 1500 Adminis-tration Manual
Note:To add further nodes, perform the step described above.
-
Status:All nodes can now be centrally administered via the HiPath 3000/ 5000 Manager E (Load via Server button).
HiPath 3000/5000Manager E
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
27/32
verbund.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started 4-9
For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System
Step by Step Startup
8. Licensing
To license the Feature Server, transfer the LIC file generated onthe licensing server (http://cls.icn.siemens.de) to the CDB directo-ry.Check the path name to the LIC file in the vsrv.ini.
Licensing can be performed either immediately or within five daysof startup. The MAC ID of the CB (control board) of theHiPath 3000 system with the lowest node ID is required for li-censing.
HiPath 3000/5000Service Manual
The MAC ID of the first HG1500 in the HiPath 3000 with the low-est node ID is required for licensing TAPI lines (TAPI 170).Enter the license key as explained in the TAPI 170 online help.
The HG1500 MAD ID is required for licensing HG 1500 IP clients(such as optiPoints) and B channels. Release the B channels andIP clients with the HiPath 3000 Manager I under Service Li-censed B Channels and Licensed Clients and transfer the CDB.Now read out the CDB again, increase the number of B channelsin use and copy back the CDB.
IP clients (optiClients) are licensed during installation.
HiPath TAPI 120 is licensed during installation.
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
28/32
HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
4-10 HiPath 3000/5000 V4.0, Getting Started
verbund.fm
Step by Step Startup
9. Further configuration
The following important parameters must then beconfigured, for example via HiPath 3000 5000 Manager E:
Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient
HiPath 3000/5000Manager E
TrunksSettings | Lines/networking | Trunks
HiPath 3000/5000Manager E
RoutesSettings | Lines/Networking | Routes HiPath 3000/5000Manager E
Class of ServicesSettings | Least Cost Routing | Class of Services
HiPath 3000/5000Manager E
Call numbersSettings | Set up Station
HiPath 3000/5000Manager E
LCRSettings | Least Cost Routing
HiPath 3000/5000Manager E
customer-specific system programming HiPath 3000/5000Service Manual
Status Activity/description Detailedinformation
=checked
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
29/32
GetstartedSIX.fm
A31003-H3540-C100-3-76D1, 03-2004
HiPath 3000/5000 V4.0, Getting Started Z-1
For internal distribution only Index
Index Z
HHiPath 3000 Networked IP System
Assigning IP addresses 3-5Configuring IP clients 3-6Delivery documents 3-2Installing additional modules 3-4Installing the hardware 3-4Licensing 3-2Requirements specifications 3-2Safety notes 3-2
Startup 3-4HiPath 3000 Standalone IP System
Assigning IP addresses 2-5Configuring IP functionality 2-6Delivery documents 2-2Installation 2-4Installing the hardware 2-4Licensing 2-2Numbering plan 2-2Requirements specifications 2-2
Safety notes 2-2Startup 2-4HiPath 5000 RSM Multi-Node System
Installing additional HiPath 3000 modules4-4
Installing the hardware 4-4HiPath 5000 RSM Multinode System
Assigning IP addresses 4-6Configuring the Feature Server 4-7Delivery documents 4-2Installation 4-5
Licensing 4-2, 4-9Merging nodes 4-8Numbering plan 4-2Requirements specifications 4-2Safety notes 4-2Startup 4-5
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
30/32
Index For internal distribution only
A31003-H3540-C100-3-76D1, 03-2004
Z-2 HiPath 3000/5000 V4.0, Getting Started
GetstartedSIX.fm
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
31/32
8/20/2019 HiPath 3000 5000 V4.0 Getting Started
32/32
Siemens AG 2004 • Information and Communication
The information provided in this document contains merely gener-
al descriptions or characteristics of performance which in case of
actual use do not always apply as described or which may change
as a result of further development of the products.
An obligation to provide the respective characteristics shall only ex-
ist if expressly agreed in the terms of contract.
www.siemens.com/hipath
Recommended