Includes:System DesignUnit SelectionSystem Layout
Unit Specifications
TM
Small Duct Heating, Cooling andIndoor Air Quality Systems
Hi-Velocity SystemsDesign Assistance Manual
Module DES - Hi-Velocity System Design 012010
www.hi-velocity.com
Manufactured By
© 1995-2009 Energy Saving Products Ltd.
It is in rooms such as this that a hybrid system of both radiant heating and the Hi-Velocity System would be the optimum system to provide comfort conditioning. This will provide the home owner with good indoor air quality, and warm floor comfort (not as effective if carpet is laid down).
A common approach to a hybrid system is to heat the basement with radiant tubing. The main floor and 2nd floor if applicable would be heated with the Hi-Velocity System. A few outlets can also be placed in the basement to provide air circulation, and supplementary heating if required.
When running Hi-Velocity Systems from a low water temperature system (e.g. A hot water tank), care must be taken when designing and installing the system. Due to the lower water temperature there will be less BTUH’s and therefore a lower supply air temperature, it is imperative that the water temperature is known at the design stage. If possible the highest temperature setting should be used, and a water tempering valve installed for the domestic use. The higher water temperature will increase system efficiencies, and the water tempering valve will reduce the risk of scalding. Since some areas have specific regulations regarding combo systems, please check your local building code for details on water tank temperatures, tempering valves, and pump timers.
Due to the lower air temperatures, when running the ductwork in an unconditioned space, the main plenum must be insulated and vapour barriered. Extra insulation should also be used in order to maintain a reasonable leaving air temperature at the vents.
To size a Hi-Velocity System for a residence, it is necessary to have an accurate heat loss/gain done for the structure. This will ensure the proper equipment is used for cooling and heating.
A heat loss/gain is done for each room, which will give a total BTUH load for the structure.
Table 01 - Example Data for Fig. 02Room Name BTUH Loss BTUH GainNookKitchenBathBed #1Bed #2Dining Rm.FoyerFamily Rm.Master BedM.Bath/WIC
8,3262,5391,1142,6673,8455,1094,1865,8599,3262,786
5,2331,688
6931,5922,1653,8022,1664,0016,0461,193
Totals 45,757 28,579
The design factors used to achieve this heat loss/gain are shown on Fig. 02.
Hi-Velocity System DesignOne of the benefits of using a hydronic system is the
versatility that you have when designing the heating system. Radiant floor heating is an excellent system, but it does have limitations. You cannot have cooling, air filtration, and humidification with a straight radiant heating system. Similarly, sometimes a forced air system is not the only option available for a house, especially if it has a lot of ceramic tile or concrete floor areas.
In the sample house included, radiant floor heating may be unable to meet the requirements to heat the nook. With the Hi-Velocity System, we can heat this room, but would have an excessive number of outlets in a small area.
Fig. 01 - NookExample
Room: NookHeat loss: 8,326 BTUHNumber of Vents: 4
Combination Hi-Velocity and Radiant
Low Water Temperature Systems
Heat Loss/Gain
The following section is basic information needed for the designer. If not done already, this section should be read thoroughly before beginning installation.
Module DESHi-Velocity System Design (2/8)
Module DES Hi-Velocity System Design (2/8)-2-
© 1995-2009 Energy Saving Products Ltd.
With the total load known for the structure, it is now possible to select the proper Hi-Velocity unit (Specifications - Pg. 7).
Table 02 – Selected fan coilSelected fan coil:Entering Water TempHouse Heat Loss:House Heat Gain:Minimum Outlets:Maximum OutletsSelected Condenser
HE-70 H180°F45,757 BTUH28,579 BTUH2” = 20 HE = 102” = 29 HE = 152.5 ton
Once the unit has been selected, the average numbers of outlets can be determined (Specifications - Pg. 7). To determine the average number of vents, the minimum is added to the maximum and divided by two.Example: (Using only 2” outlets)
(Min Outlets (20) + Max Outlets (29) / 2 = 25) * *Example shown using only 2” outlets
With the average number of vents known it is now possible to determine the average BTUH output per vent. Dividing the average number of outlets into the fan coil output (Specifications - Pg. 7) will give an average BTUH output per vent.
Example:BTUH per Outlet for HEATING
73,800 BTUH / 25 = 2,952 BTUH/OUTLET(2,952 BTUH delivery per outlet for Heating)
BTUH per Outlet for COOLING30,000 BTUH / 25 = 1,200 BTUH/OUTLET(1,200 BTUH delivery per outlet for Cooling)
The BTUH per outlet is then used to figure out how many outlets are required for each room. As an example, here is a room by room load calculation for the house plan included (Fig. 02).
Table 03 – Number outlets per room
Room Name
BTUH LOSS
BTUH GAIN
If using 2” (51mm)Vents
If using HE Vents
NookKitchenBathBed #1Bed #2Dining Rm.FoyerFamily Rm.Master BedM.Bath/WIC
8,3262,5391,1142,6673,8455,1094,1865,8599,3262,786
5,2331,688693
1,5922,1653,8022,1664,0016,0461,193
4212232351
2111121231
Totals 45,757 28,579 25 15
A room (Nook) that has a heat loss of 8,326 BTUH and a heat gain of 5,233 BTUH will need 4 vents.
Example:
4 x 2,952 BTUH = 11,808 BTUH(11,808 > 8,326 Heating requirements satisfied)
4 x 1,200 BTUH = 4,800 BTUH(4,800 < 5,233 Cooling requirements not satisfied)
The heating checks out but the cooling doesn’t in this example. We allow a 0.1 variance on vent checks, which gives a little leeway with vent placement. Also with the kitchen being an adjoining room with an extra 712 BTUH it will help the nook maintain the desired temperature
Table 04 - System CheckHeating Cooling
Fan CoilOutput Heating
HouseBTUH Loss
Fan CoilOutputCooling
HouseBTUH Gain
Nook 11,808 8,326 4,800 5,233Kitchen 5,904 2,539 2,400 1,688Bath 2,952 1,114 1,200 693Bed #1 5,904 2,667 2,400 1,592Bed #2 5,904 3,845 2,400 2,165Dining Rm. 8,856 5,109 3,600 3,802Foyer 5,904 4,186 2,400 2,166Family Rm. 8,856 5,859 3,600 4,001Master Bed 14,760 9,326 6,000 6,046M.Bath/wic 2,952 2,786 1,200 1,193Totals 73,800 45,757 30,000 28,579
Not all rooms will check out for cooling as illustrated in Table 04, we allow a 0.1 variance on vent checks per room. The Main concern is the total unit output being higher than house BTUH loss. With the venturi action of the Hi-Velocity System the individual rooms will affect each other and help maintain the desired room temperature.
Unit Selection
Average BTUH Per Outlet
Difference in no. of Vents Req’d for Htg & ClgThere may be cases when the number of outlets
needed for heating is significantly different than the amount needed for cooling. This is usually caused by a large appliance load or an excessive amount of windows. If this happens you will have to use the greater number of outlets to provide both heating and cooling for the room. The vents have dampers and can be adjusted for individual room comfort. In cooling mode the outlets must be in the fully open position or there will be a loss in performance and the efficiency of the system.
Module DESHi-Velocity System Design (3/8)
Module DES Hi-Velocity System Design (3/8)-3-
© 1995-2009 Energy Saving Products Ltd.
Fig. 02 - House Drawing
• This drawing is not to scale.• This is an example only and may
not reflect an actual heat loss/gain.
Glass door6’ x 7’
Dining Room21’ x 11’
Foyer21’ x 10’
Family Room21’ x 16’
Master Bedroom17’ x 22’MB/W.I.C.
10’ x 18’Bedroom #2
14’ x 13’
Bedroom #111’ x 13’
Kitchen13’ x 11’
Nook15’ x 14’
Garage
Wood Door3’ x 7’
2’ x 3’
2’ x 3’
2’ x 3’
2’ x 3’
3’ x 4’
3’ x 4’
4’ x 4’ 4’ x 4’ 4’ x 4’
2’ x 6’
2’ x 6’
4’ x 6’
2’ x 6’
2’ x 6’
2’ x 6’
2’ x 6’
1’ x 6’
1’ x 6’
Wood Door3’ x 7’
Glass door3’ x 7’
4’ x 6’
Bath11’ x 6’
Design Factors for ESP’s heat calc programAir change/Hour 0.3Altitude above sea level (ft) 1500Outdoor Heating temp (ºF) -15Outdoor Cooling DB temp (ºF) 95Humidity 40%
Glass Double/Coated 0.46Cold floor area R-20 Insulation (6”)Exposed ceiling R-40 insulation (12”)Standard doors 1” solid coreGlass doors High Eff. Patio doorExposed wall R-20 Insulation (6”)Construction New
All ceiling heights are 9’
Fan coil and main plenum will belocated in the crawl space
Module DESHi-Velocity System Design (4/8)
Module DES Hi-Velocity System Design (4/8)
4’ x 6’
4’ x 6’
-4-
© 1995-2009 Energy Saving Products Ltd.
With the total vents known, the layout of the Hi-Velocity System can now be done. Start with individual vent placements (if you have not already read the section on Vents in System Design, please do so before starting). Then place the main plenum so the flex runs will be the shortest length possible. With the plenum placed, the flex runs can be drawn connecting the vent outlet to the main plenum.
Fig. 03 - Placing Vents: Nook
4 Vents distributedevenly throughout
the space.
With this room 3 two inch vents would have satisfied the heating requirements, but would not satisfy the cooling requirements. For the nook we need 4 two inch vents for cooling, so 4 two inch vents must be placed in the nook. The vents do have an adjustable damper and can be adjusted for individual room comfort if too much heating is being supplied. In cooling mode the outlets must be in the fully open position.
With a 56/44 split we will be able to reach all vents using standard 10’ and 15’ flex runs. If you have to extend the flex runs longer than 10’, reference Table 05 for adjustment factors. Space Savers series minimum length is 5’, and adjustments must be made from table 05 if extending flex runs longer than 5’.
For this layout we have chosen to use a Main Plenum with a 56/44 bullhead tee split. On one side 14 vents will used, while 11 will be used on the other. This is allowable as we can use a Bull Head Tee up to a 60/40 split. If the split is greater than 60/40, a Branch Tee should be used instead of the Bullhead Tee. See Module DUC - Installing Plenum and Branch Duct for Installation Instructions.
Table 07 - Allowable Branch Duct LengthsModel Min. Length Max. Length
HE Series 10’ (3.05m) 25’ (7.62m)
The main plenum we choose to use is 8”, it is not required to use 8” for the whole run. If space or cost is a concern, the main plenum can be reduced down to a smaller size. If reducing the plenum, reference Table 06 for allowable length and maximum number of vents for the size chosen. Never reduce at a bullhead tee, always reduce after the bullhead tee or you can lose approximately 20% of your airflow.
Once the vents and plenum have been drawn in, the two may now be connected with the flexible branch duct. The minimum flex run is 10’ (3.05m) and the maximum is 25’ (7.62m)
System Layout
Drawing Vent Placement
Drawing the Plenum
Drawing the Flex Runs
To demonstrate a vent layout, we’ll place 4 two inch vents to properly condition the Nook (Fig. 03). From table 16 we calculated that the Nook has a Heat loss/gain of 8,326/5,233, which will require 4 two inch vents to satisfy heating and cooling requirements.
Module DESHi-Velocity System Design (5/8)
Module DES Hi-Velocity System Design (5/8)
The outlets should be located where it is considered to be a “low traffic area”. Typical areas are in the corner of a room, or to the side of a window or door. When the vents are properly located, the home owner can expect to have a nearly draft free home.
Once all the vents have been placed in each room, the main plenum can now be drawn. Figs. 04 and 05 shows where all vents have been located in the individual rooms.
Table 06 – Duct ReductionDuct Size
# of 2”(51mm) Vents
# of Vents (HE)
Max Length
4” (102mm) 4 N/A 30’(9.14m)
5” (127mm) 6 3 40’(12.19m)
6” (152mm) 12 6 50’(15.24m)
7” (178mm) 19 9 60’(18.29m)
8” (203mm) 29 14 70’ (21.33m)
10” (254mm) 48 24 100’ (30.48m)
Table 05: De-rating ValuesHE Series
Tubing LengthAdjustment Factor
10’0%
15’10%
20’20%
25’35%
-5-
© 1995-2009 Energy Saving Products Ltd.
Module DESHi-Velocity System Design (6/8)
Module DES Hi-Velocity System Design (6/8)
Fig.
04
- Hou
se L
ayou
t usi
ng 2
” (5
1mm
) Ven
ts
8” (2
03m
m) M
ain
Ple
num
Fan
coil
inC
raw
l spa
ce
44%
spl
it12
2” (
51m
m)
Tota
l Ven
ts
56%
spl
it14
2” (
51m
m)
Tot
al V
ents
Vent
in
stal
led
inth
e K
ick
Spa
ce
GA
RA
GE
DIN
ING
NO
OK
KIT
CH
.FO
YER
FAM
ILY
BDR
M 1
MA
STER
BD
RM
MB/
WIC
Bra
nch
Duc
ts
to b
e in
stal
led
18” (
457m
m)
from
elb
ows,
te
es, e
nd c
aps
2” (5
1mm
) Ven
tM
ain
Ple
num
2” (5
1mm
) Fle
xibl
e B
ranc
h du
ctS
idew
all V
ent
Lege
nd
Fig.
05
- Hou
se L
ayou
t usi
ng 2
” (51
mm
) & H
E Ve
nts
8” (2
03m
m) M
ain
Ple
num
Fan
coil
inC
raw
l spa
ce
Bra
nch
Duc
ts
to b
e in
stal
led
18” (
457m
m)
from
elb
ows,
te
es, e
nd c
aps
44%
spl
it12
2” (
51m
m)
Tota
l Ven
ts
56%
spl
it14
2” (
51m
m)
Tot
al V
ents
Vent
in
stal
led
inth
e K
ick
Spa
ce
GA
RA
GE
DIN
ING
NO
OK
KIT
CH
.FO
YER
FAM
ILY
BDR
M 1
MA
STER
BD
RM
MB/
WIC
X
X X X X X
X XX
Roo
ms
refle
ct e
xtra
ve
nt e
quiv
alen
ts, t
o de
mon
stra
te m
ixin
g 2”
& H
E Ve
nts
X
2” (5
1mm
) Ven
tH
E V
ent
Mai
n P
lenu
mFl
exib
le B
ranc
h du
ctS
idew
all V
ent
Lege
nd
X
-6-
© 1995-2009 Energy Saving Products Ltd.
Module DESHi-Velocity System Design (7/8)
Module DES Hi-Velocity System Design (7/8)
(1) Maximum length is from the unit to the supply end run cap. More than one run per unit is allowable.(2) Minimum of eight 2” outlets per ton of cooling needed. (HE Duct = Minimum four outlets per ton)
Model HE-50/51 HE - 70/71 HE - 100/101 Hot Water Heating 2 Ton Airflow (7.0 kW) 3 Ton Airflow (10.6 kW) 5 Ton Airflow (17.5 kW)
Coil Type 6 Row/10 FPI 6 Row/10 FPI 6 Row/10 FPIMax. BTUH @ 190°F E.W.T. (kW @ 88°C)Max. BTUH @ 180°F E.W.T. (kW @ 82°C)Max. BTUH @ 170°F E.W.T. (kW @ 77°C)Max. BTUH @ 160°F E.W.T. (kW @ 71°C)Max. BTUH @ 150°F E.W.T. (kW @ 66°C)Max. BTUH @ 140°F E.W.T. (kW @ 60°C)Max. BTUH @ 130°F E.W.T. (kW @ 54°C)Max. BTUH @ 120°F E.W.T. (kW @ 49°C)Max. BTUH @ 110°F E.W.T. (kW @ 43°C)
GPM Flow ratings (L/s)Pressure Drop in FT. (m) H2O CFM @ 68°F E.A.T. (L/s @ 20°C E.A.T.)
59,400 (17.4 kW)54,500 (16.0 kW)49,600 (14.5 kW)44,600 (13.1 kW)39,700 (11.6 kW)34,700 (10.2 kW)29,700 (8.7 kW)24,800 (7.3 kW)20,100 (5.9 kW)
5 (0.32 L/s)3 (9.15 KPa)470 (221 L/s)
89,200 (26.1 kW)81,800 (24.0 kW)74,400 (21.8 kW)67,100 (19.7 kW)59,700 (17.5 kW)51,800 (15.2 kW)44,700 (13.1 kW)37,400 (11.0 kW)30,300 (8.9 kW)
7 (0.44 L/s)6.5 (19.8 KPa)700 (300 L/s)
134,000 (39.3 kW)122,900 (36.0 kW)111,800 (32.8 kW)100,700 (29.5 kW)89,700 (26.3 kW)78,400 (23.0 kW)67,100 (19.7 kW)56,200 (16.5 kW)45,500 (13.3 kW)
10 (0.63 L/s)6.8 (20.7 KPa)1120 (528 L/s)
Chilled Water Cooling 2 Ton Airflow (7.0 kW) 3 Ton Airflow (10.6kW) 5 Ton Airflow (17.5 kW)Coil Type 6 Row/10 FPI 6 Row/10 FPI 6 Row/10 FPI(WCM Modules in Cooling Mode) Total Sensible Total Sensible Total Sensible
Max. BTUH @ 48°F E.W.T. (kW @ 8.9°C)
Max. BTUH @ 46°F E.W.T. (kW @ 7.8°C)
Max. BTUH @ 44°F E.W.T. (kW @ 6.7°C)
Max. BTUH @ 42°F E.W.T. (kW @ 5.6°C)
Max. BTUH @ 40°F E.W.T. (kW @ 4.4°C)
19,300 (5.7 kW)
20,900 (6.1 kW)
22,600 (6.6 kW)
24,200 (7.1 kW)
25,800 (7.6 kW)
13,700 (4.0 kW)14,200 (4.2 kW)14,900 (4.4 kW)15,700 (4.6 kW)16,300 (4.8 kW)
27,000 (7.9 kW)29,400 (8.6 kW)31,800 (9.3 kW)34,000 (10.0 kW)36,400 (10.7 kW)
19,200 (5.6 kW)20,000 (5.9 kW)21,000 (6.2 kW)21,800 (6.4 kW)23,000 (6.7 kW)
42,100 (12.3 kW)45,800 (13.4 kW)49,500 (14.5 kW)53,200 (15.6 kW)56,800 (16.6 kW)
30,300 (8.9 kW)32,100 (9.4 kW)33,700 (9.9 kW)35,100 (10.3 kW)36,400 (10.7 kW)
(WCM Modules in Heating Mode) Total Total TotalMax. BTUH @ 150°F E.W.T. (kW @ 66°C)Max. BTUH @ 140°F E.W.T. (kW @ 60°C)Max. BTUH @ 130°F E.W.T. (kW @ 54°C)Max. BTUH @ 120°F E.W.T. (kW @ 49°C)Max. BTUH @ 110°F E.W.T. (kW @ 43°C)
GPM Flow ratings (L/s)Pressure Drop in Ft. (m) H2O
39,700 (11.6 kW)34,700 (10.2 kW)29,700 (8.7 kW)24,800 (7.3 kW)20,100 (5.9 kW)
5 (0.32 L/s) 3 (9.15 KPa)
59,700 (17.5 kW)51,800 (15.2 kW)44,700 (13.1 kW)37,400 (11.0 kW)30,300 (8.9 kW)
7 (0.44 L/s)6.5 (19.8 KPa)
89,700 (26.3 kW)78,400 (23.0 kW)67,100 (19.7 kW)56,200 (16.5 kW)45,500 (13.3 kW)
10 (0.63 L/s)6.8 (20.7 KPa)
Refrigerant CoolingRPM Modules
BTUH Refrigerant TX Cooling 1.5 - 2.0 Tons (3.5-6.4 kWh) 2.5 - 3.0 Tons (8.8-10.5 kWh) 3.5 - 5.0 Tons (12.3-17.5 kWh)
Electrical HeatingKilowatt Range (240v) 5 - 15 kW 5 - 18 kW 5 - 23 kW
Fan CoilVoltage 115/230/1/50/60 F.L.A. 8 amp
Max Rated C.F.M. (L/s)Horse Power/WattsR.P.M.Integral Surge and Fuse SystemSupply Air SizeSupply Maximum Length(1)
Return Size Needed
520 (245 L/s)3/4 - 310Variable
Yes8” round (203mm)
70’ (21.3m)12” (120 in2) (305mm/774cm2)
770 (363 L/s)3/4 - 530Variable
Yes8” round (203mm)
80’ (24.4m)12” (120 in2) (305mm/774cm2)
1260 (595 L/s)3/4 - 720Variable
Yes10” round (254mm)
100’ (30.5m)14” (168 in2) (356mm/1084cm2)
Minimum Outlets(2)
Maximum Outlets12 (2’) 6 (HE)24 (2”) 12 (HE)
20 (2”) 10 (HE)32 (2”) 16 (HE)
28 (2”) 14 (HE)52 (2”) 26 (HE)
Shipping Weight 80 lbs (36.3 Kg) 95 lbs (43.1 Kg) 115 lbs (52.2 Kg)
Fan Coil SizeLengthWidth
Height
32” (813mm)14” (356mm)18” (457mm)
32” (813mm)19” (483mm)18” (457mm)
32” (813mm)25” (635mm)18” (457mm)
HE Series Specifications (Standard & Metric)
Matching CoilsRefrigerant Coils
RPM-E-50, 70, 100Chilled Water Coils
WCM-50, 70, WM-100Hot Water CoilsHV-50, 70. 100 - 6 RowElectrical CoilsESH-650 (5-15 kW)ESH-750 (5-18 kW)ESH-1100 (5-23 kW)
-7-
Energy Saving Products Ltd., established in 1983, manufactures the Hi-Velocity SystemsTM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support.
For all of your Heating, Cooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you!
Phone: 780-453-2093 Fax: 780-453-1932
Toll Free: 1-888-652-2219HARDI
www.hi–velocity.com
Hi-Velocity HE Fan Coils, Green TechnologyBuild Smart, Breathe Easy
Small Duct Heating, Cooling and IAQ Systems
Recommended