HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

Preview:

Citation preview

HELUWIND® WK POWERLINE ALU 105°C, 0,6/1kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

UV resistantoil-resistantSpecial insulation black

Sheath special compound easy to assembleOperating temperature at conductormax. +105°C

recyclableblack jacket

Nominal voltage 0,6/1kV (50Hz)

NotePlease ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Test voltage2,5kV (50Hz)Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsacc. to DIN VDE 0250-813UL/CSA in preparation

ApplicationThe WK Powerline ALU is a highly flexible aluminum cable with a fine wire strand structure, which is suitable for use in the area of energymanagement - especially in the power wiring of a wind turbine. Thanks to its high flexibility and low weight, this cable can be installed inthe tower in one continuous length. Time-intensive wiring of the individual tower segments is eliminated.

The decisive advantage, however, lies in the process safety of the connection technology: The number of breaks from the top tower segmentto the inverter is reduced from as many as 90 connection points to only 18 connections, depending on the number of power cables andtower segments. The installation effort in the field is thereby reduced from several days to a few hours.

For torsional use we recommend the WK 103-T, WK 135-T or WK 137-T.

The WK Powerline ALU may only be prepared with the certified connection technology of HELUKABLE®. Either with the C8Crimp or screw connector (tested in accordance with IEC 61238-1 Cl. A). See Accessories section in the catalog.The cable is also optionally available in a halogen-free design with UL/CSA approval and a rated voltage of 1.8/3 kV.

= The product conforms to the EC Low Voltage Directive 2006/95/EC

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

379,0206,017,4-1 x 70707062 950,0544,024,5-1 x 185706088480,0280,018,8-1 x 95707063 1150,0706,027,5-1 x 240706089576,0355,020,6-1 x 120707064 1400,0882,031,9-1 x 300706084665,0441,022,4-1 x 150706408 1680,01176,036,7-1 x 400706085

Dimensions and specifications may be changed without prior notice.

HELUWIND® WK POWERLINE ALU robust 105°C,0,6/1kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

extremely abraison resistantUV resistantSpecial insulation black

Sheath special compound oil-resistantOperating temperature at conductormax. +105°C

easy to assembleblack jacketrecyclable

Nominal voltage 0,6/1kV (50Hz) NoteTest voltage2,5kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsacc. to DIN VDE 0250-813UL/CSA in preparation

Application

= The product conforms to the EC low-voltage directive 2006/95/EG.

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

460,0206,017,4-1 x 70707097 950,0544,024,5-1 x 185707101536,0280,018,8-1 x 95707098 1150,0706,027,5-1 x 240707102576,0355,020,6-1 x 120707099 1398,0882,031,9-1 x 300707103665,0441,022,4-1 x 150707100 1588,01176,036,7-1 x 400707104

Dimensions and specifications may be changed without prior notice.

HELUWIND® WK POWERLINE ALU 105°C, 1,8/3kVflexible ALU-Conductor, direct burial

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

UV resistantoil-resistantSpecial insulation black

Jacket special compound easy to assembleOperating temperature at conductormax. +105°C

recyclableblack jacketdirect burial

Nominal voltage 1,8/3 kV (50Hz) NoteTest voltage9 kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185707647 1520,0882,033,2-1 x 3007074321250,0706,028,4-1 x 240706578 1855,01176,038,1-1 x 400707648

Dimensions and specifications may be changed without prior notice.

HELUWIND® WK POWERLINE ALU robust 105°C,1,8/3kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

extremely abraison resistantUV resistantSpecial insulation black

Sheath special compound oil-resistantOperating temperature at conductormax. +105°C

easy to assembleblack jacketrecyclable

Nominal voltage 1,8/3kV (50Hz) NoteTest voltage9kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185707692 1520,0882,033,2-1 x 3007076941250,0706,028,4-1 x 240707693 1855,01176,038,1-1 x 400707695

Dimensions and specifications may be changed without prior notice.

HELUWIND ® WK POWERLINE ALU halogen free105°C 1,8/3kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

halogen freeabraison resistantSpecial insulation black

Sheath special compound UV resistantOperating temperature at conductormax. +105°C

oil-resistantblack jacketeasy to assemble

Nominal voltage 1,8/3kV (50Hz)

recyclable

Test voltage9kV (50Hz)

NotePlease ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterApprovalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185709143 1400,0882,033,2-1 x 3007091451150,0706,028,4-1 x 240709144 1680,01176,038,1-1 x 400709146

Dimensions and specifications may be changed without prior notice.