Gaspace Advance
Features & Benefits
Fast accurate MAP headspace analysis forgas flushed food and pharmaceutical products
Easy to use touch screen
5 different test methods
Easy to set up and use
Intuitive menu
Auto calibrate
Auto diagnosis
Set tests for pass or fail
Printer option
Computer software option
Waterproof option
Applications
Fresh Meat Cooked Meat Vegetables SaladsBakery Snack Foods Ready Meals Fish
Pharmaceutical Vials Pharmaceutical Packaging
Using AutoSense allows many packs to betested with just one button press. Savingyou time and making your QA departmentmore efficient.
Simple configuration for all test types andmethods – no special training required touse all the highly advanced features.
One analyser can test all pack sizes andvery low volumes. Rigid cans and jars canbe analysed with the simple to use CanPiercing station.
Ensures the instrument is alwaysperforming to it’s highest degree ofaccuracy - essential for HACCPcompliance.
Using the large buttons and big cleardisplay; testing is simple, errors areeliminated and no special operator trainingis required.
Test Easily
Test Quickly
Test all pack sizes
Can Piercing Station
Simple configuration
Auto-Cal & Auto diagnosis
With Timed tests, AutoSense, Peak / Valley,Syringe Direct Injection or Continuoustesting. Fast configuration and fastselection, provides the test method that isbest for you.
Test how you want to
The next generation Gaspace Advancefrom Systech Instruments. Fast, accurateand simple to use yet full of the most
advanced features available inheadspace analysis.
All Gaspace Advance headspaceanalysers offer automatic calibration,diagnostics and control.
The Gaspace Advance offers consistentlyreliable results and simplicity in operationallowing you to maximise your productionefficiency.
GS1, GS2 & GS3
BenchMountWeight: 4.5 kg140H x 390W x 270DmmStainless steel and stoveenameled aluminium
GS1&GS1W Oxygen GS2&GS2W Carbon Dioxide
GS1W, GS2W & GS3W
Waterproof Carrying CaseWeight: 6.5 kg170H x 410W x 330DmmImpact resistant ABS
The Gaspace Advanceis also available with anelectrochemical oxygensensor (GS1L, GS3L) formeasurements requiringonly % levels of oxygen.All models are availablein a waterproof carryingcase.
GS3&GS3W Oxygen & Carbon Dioxide
Speeds up the analysis process andremoves any uncertainty with interpretingmeasurements.
Makes the documentation process a wholelot simpler. No cables and more space onthe bench top.
The GS Data Manager Software allows youto download results stored on your analyserand upload new settings. You can alsosearch through your stored data by time,date, user, production line or any of theproduct information.
Software
Easy to see Pass / Fail messages
Built-in printer option
Data Download View
Analyser Configuration View
Sensor Type
GS1 and GS1W
GS2 and GS2W
GS3 and GS3W
Response timeMinimum volume of sample gas
Accuracy: Oxygen
Carbon Dioxide
Range selection
Display type
Operating conditionsSample connections
Alarms
Internal datalogCommunications interfacesAuto diagnostic routineAuto-calAuto pass/failAuto test sequencing
OptionsInternal PrinterFlexible package kitCan Piercing StationCarry CaseData Transfer Software
Power RequirementsMains power
Systech Instruments have over 25 years experience of providing analysis solutions for a widerange of industries. From our manufacturing plant in the UK we produce gas analysers forindustrial process industries, headspace analysers for monitoring gas flushing of food products,and our range of permeation analysers.
Systech reserve the right to change specifications without notice. 06/09
17 Thame Park Business Centre, Wenman Road,Thame, Oxfordshire OX9 3XATel: +44 (0)1844 216838 Fax: +44 (0)1844 217220E-mail: advice@systech.co.uk www.systechinstruments.com
Technical Specifications
Illinois Instruments, inc2401 Hiller Ridge RoadJohnsburg, Illinois 60050U.S.ATel: +1 815 344 6212Fax: +1 815 344 6332E-mail: sales@illinoisinstruments.comwww.illinoisinstruments.com
Oxygen 0 to 100%, Zirconia, solid state, ultra low volume
Carbon Dioxide 0 to100%, dual wavelength, Infra-red
Oxygen 0 to 100%, Zirconia, solid state, ultra low volumeCarbon Dioxide 0 to 100%, dual wavelength, Infra-redBalance Gas 0 to 100%, Arithmetic
3 secondsExtremely small, dependent on equilibrium levels. Consult factory.
10 to 100% 0.2% absolute (max 2% of reading) and ±1 on the last digit.1 to 9.99% 0.02% absolute (max 2% of reading) and ±1 on the last digit.0 to 0.999% 0.005 % absolute and ±1 on the last digit.
± 0.5% absolute and ±1.5% of reading
Automatic to 3 decimal placesOxygen: 0.001% to 99.9%CO2: 0.1% to 99.9%Wide angle 95mm x 55mm 4.5" High Resolution Touchscreen LCD
Sample and ambient temperature: 10 to 40°CNeedle probe, can piercing station or direct syringe injection
Programmable high/low limits for each measured gas, individual settingfor up to 99 product, user and production line codes.Screen and printed display of high/low alarm conditions
Stores over 1000 measurement results and alarm conditionsSerial computer interface for reports and data loggingInitiated upon power upAuto calibration routine standardUser programmable. Screen and printed display of alarm conditionsInitiated by sample probe insertion into pack
Prints the results and alarms for each testEverything required for analysis from standard packets and pouchesFor analysis from rigid cans and jarsAluminium framed flight caseFor configuration and downloading of reports and internal datalog
90-260 Vac, 50/60Hz – Automatically sensed
Thank you for reading this data sheet.
For pricing or for further information, please contact us at our UK Office, using the details below.
UK OfficeKeison Products,
P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.Tel: +44 (0)330 088 0560Fax: +44 (0)1245 808399
Email: sales@keison.co.uk
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
Recommended