EYEDIFF PLUS +3.50D Diffractive Multifocal IOL “A New Alternative”. Prof. Dr. Daniel H. Scorsetti University of the Salvador - Catholic Pontificia University of Argentina Faculty of Medicine - Faculty of Medical Sciences Chair of Ophthalmology Buenos Aires, Argentina. - PowerPoint PPT Presentation
Citation preview
EYEDIFF PLUS +3.50DEYEDIFF PLUS +3.50DDiffractive Multifocal IOLDiffractive Multifocal IOL
““A New Alternative”A New Alternative”
Prof. Dr. Daniel H. ScorsettiUniversity of the Salvador - Catholic Pontificia University of Argentina
Faculty of Medicine - Faculty of Medical SciencesChair of OphthalmologyBuenos Aires, Argentina
Eyediff Plus +3.50D: Eyediff Plus +3.50D: Technical SpecificationsTechnical Specifications
Diffractive Technology
Perfect Light Distribution for Distance &Near( 60/40)
Addresses Cataract Patients with or without Presbyopia
Allowed Patients a High Level of Freedom From Glasses in
clinical trial
EYEEYEDIFF Plus Presbyopic IOLDIFF Plus Presbyopic IOL
Advantages Provides multifocal vision Reduced pupil dependency Balanced distribution of light Able to tolerate some decentration
Full Optic Regular Diffractive IOLFull Optic Regular Diffractive IOL
Advantages Provides multifocal vision Reduced pupil dependency Balanced distribution of light Able to tolerate some decentration
* Creates Halos and scattering Light
Disadvantages Potential for Scattering of light
and glare and halos at nightbut
Full Optic Diffractive IOLFull Optic Diffractive IOL
ZonesZones
EYEDIFF Plus - Predictable refractive outcome EYEDIFF Plus - Predictable refractive outcome
+3.00D Addition
EYEDIFF Plus - Predictable refractive outcome EYEDIFF Plus - Predictable refractive outcome
+3.50D Addition
EYEDIFF Plus - Predictable refractive outcome EYEDIFF Plus - Predictable refractive outcome
+4.00D Addition
Show OpticShow Optic
Far
Near
Intermediate
EYEDIFF PLUS – Predictable Customized LIOEYEDIFF PLUS – Predictable Customized LIO
EYEDIFF PLUS - Predictable refractive outcome EYEDIFF PLUS - Predictable refractive outcome Analysis of the mistake : Analysis of the mistake : Square root of the sum of the squaresSquare root of the sum of the squares
Warren E. Hill, MD, FACSWarren E. Hill, MD, FACS
EYEDIFF PLUS - Predictable refractive outcome EYEDIFF PLUS - Predictable refractive outcome Analysis of the mistake : Analysis of the mistake : Square root of the sum of the squaresSquare root of the sum of the squares
Warren E. Hill, MD, FACSWarren E. Hill, MD, FACS
Aspheric Optic (Aberration Neutral)Aspheric Optic (Aberration Neutral)
360° Square Edge360° Square Edge
Edge thickness correspond to
standard designed IOLs
Square edge design
Perfect centration in the capsular bag
Perfect optical performance
Extremely low incidence of PCO
Anti Z effect Haptic design
EYEDIFFEYEDIFF Plus 360⁰Square Edge Plus 360⁰Square Edge
Careful Keratometry1.0D corneal power error affects 1.3 to 1.6D IOL
power calculation Careful Axial Length
1.0mmAL error affects the post-operative refraction by 1.2 to 2.5D aprox.
IOL Master: SRK II--------- 118.6 SRK T-------- 118.4 Holladay 1 - sf--- 1.37 Haigis ----- a0=0.95, a1=0.4, a2=0.10 Hofer - pACD-- 5.17
Aim Emmetropia & Astigmatism <1.0D A-Const. & ACD ( Surgeon Factors)
IOL Power calculationIOL Power calculation
Objective: to compare the visual quality preop and postop., between 2 multifocal IOLs and 1 monofocal
Material and methods : 60 eyes of 30 pts. divided into 3 groups, informed and signed assent, cataract degrees II and III, older than 55 years (average 60 years), without ocular disease or astigmatism > 1.0D. Bilateral implants, the same IOL in every patient (not mix and match)
Equipment: Alcon InfinityTechnique : Facotorsional with Ozil IP, 2.2mm (intrepid)Incision in the steepest axis and the same protocol in all cases
• Group 1: 10 pts. Acrysoft IQ• Group 2: 10 pts. Acrysoft Restor• Group 3: 10 pts. EYEDIFF PLUS +3.5D
Clinical TrialClinical Trial
Preop Complete ocular exam:• UCVA & BCVA: far, intermediate (70 cm) and near (40 cm)• Pentacam HR• IOL Master• Contrast Sensibility : photopic and mesopic• NEI VFQ-25 Questionnaire with Apéndix NEI VFQ-39 (in Spanish)
6 questions to evaluate visual general health20 questions to evaluate difficulties in visual activities 13 questions to evaluate level of acceptance of visual loss
Clinical TrialClinical Trial
NEI VFQ: National Eye Institute, Visual Function Questionnaire
Postop complete examination : days 1 - 7- 30 - 90
• UCVA & BCVA: far, intermediate (70 cm) and near (40 cm)• Pentacam HR• Contrast Sensibility : photopic and mesopic• NEI VFQ-25 Questionnaire with Apéndix NEI VFQ-39 (in Spanish)
6 questions to evaluate visual general health20 questions to evaluate difficulties in visual activities13 questions to evaluate level of acceptance of visual loss
• Follow-up 3 months
Clinical TrialClinical Trial
Questionnaire • Group 2 and 3: better in postop. to read newspaper and close
vision activities. • Group 3: less difficulty in night driving, But without statistically
significant difference with 2. • Group1: statistical significant difference to favor to drive by night
Without intraop complications Without PCO Descentrations
• 2 minor in group 2• 1 minor in group 3
Halos/Glare• 3 tolerable in group 2• 2 tolerable in group 3
Results Results
UCVA BCVA
0.17
0.58
0.750.89
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
0.51
0.790.95 1
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
Results FAR – GROUP 1: Acrysoft IQResults FAR – GROUP 1: Acrysoft IQ
UCVA BCVA
0.18
0.65
0.810.91
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
0.55
0.71
0.93 1
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
Results FAR – GROUP 2: Acrysoft RestorResults FAR – GROUP 2: Acrysoft Restor
Results FAR – GROUP 3: EYEDIFF PLUSResults FAR – GROUP 3: EYEDIFF PLUS
UCVA BCVA
0.23
0.71
0.91 0.94
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
0.42
0.76
0.99 1
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
UCVA BCVA
0.28
0.79
0.93 0.95
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
0.51
0.92 1 1
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
Results NEAR – GROUP 2: Acrysoft RestorResults NEAR – GROUP 2: Acrysoft Restor
AV S/C AV C/C
0.32
0.73
0.830.96
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
0.62
0.89 0.95 1
00.10.20.30.40.50.60.70.80.9
11.1
Preop 1 WeekPO.
1 MonthPO.
3Months
PO.
Results NEAR – GROUP 3: EYEDIFF PLUSResults NEAR – GROUP 3: EYEDIFF PLUS
Intermediate Vision (70 cm)Intermediate Vision (70 cm)
GROUP 2Acrysof Restor DECIMAL DISTANCE
INTERMEDIATE WITHOUT CORRECTION 0.4 70 cm
INTERMEDIATE WITH CORRECTION 1.0 70 cm
GROUP 3 – EYEDIFF PLUS DECIMAL DISTANCE
INTERMEDIATE WITHOUT CORRECTION 0.5 70 cm
INTERMEDIATE WITH CORRECTION 1.0 70 cm
EYEDIFFEYEDIFF Plus Plus
EYEDIFFEYEDIFF Plus Plus
ConclusionsConclusions Less adverse effectsLess adverse effects
Good results post-surgeryGood results post-surgery
Individual map wIndividual map with MTF and topography of ith MTF and topography of
IOL powerIOL power
Variety of powers for nearVariety of powers for near
First Customized IOL First Customized IOL
Cost
Thank you very much!!!Thank you very much!!!
danielhs@arnet.com.ardanielhs@arnet.com.ar