View
7
Download
2
Category
Preview:
DESCRIPTION
Yokogawa Feild Mate
Citation preview
Yokogawa Electric Corporation
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
BASIC Fieldmate R1.02for the Salesperson
FOR INTERNAL USE ONLY
Proprietary info goes here…Page.2
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
What is Fieldmate ?
• A single tool for the management of field devices• It supports both the FDT and DD technology• It helps in
- initial setup- configuration- daily maintenance and
- troubleshooting of field devices.
Using NI-FBUS card Using HART modem
Proprietary info goes here…Page.3
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
FDT Technology
• FDT = Field Device Tool, but it is not a tool
• FDT is an open INTERFACE SPECIFICATIONS.
It defines the system environment in which the DTM runs.
DTM (Device Type Manager) is a device driver encapsulating all the device functions.It is similar to printer driver.
More details atwww.fdtgroup.org
Proprietary info goes here…Page.4
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
What is included in Fieldmate CD ?
Please note that it contains ALL DD that is registered with theHART COMMUNICATION FOUNDATION and the Fieldbus FOUNDATION
Proprietary info goes here…Page.5
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Example of HART Device Setup
Proprietary info goes here…Page.6
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Example of FF-H1 Device Setup
Proprietary info goes here…Page.7
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Why Buy Fieldmate ?
Easy to use (Plug and Play)
Easy to access field device parameter
Trending helps to troubleshoot intermittent device fault
Keeps history of what has been done
Supports multiple protocols
Proprietary info goes here…Page.8
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
• Easy to Use Fieldmate• Easy to Access field devices
Intuitive Operation from Segment Viewer
Proprietary info goes here…Page.9
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
HART Device using DTM for Initial Setup
Menutree
Easy Setup
Proprietary info goes here…Page.10
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Parameter ManagerScreen
- Magenta is writable
- Yellow is read-only
FF Device using DD (Device Description) for setting parameter
Proprietary info goes here…Page.11
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Device Viewer for troubleshooting
Proprietary info goes here…Page.12
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Trending to help in troubleshooting
AI01-OUT
-1.26
-1.255
-1.25
-1.245
-1.24
-1.235
-1.23
-1.225
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
AI01-OUT
Exporting trends to Excel Spreadsheet
Proprietary info goes here…Page.13
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
DD Menu for FF Device Calibration
Zeroing of transmitter
Proprietary info goes here…Page.14
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Loop Test to verify Device Operational Health
Proprietary info goes here…Page.15
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
History will display all operation logs
Proprietary info goes here…Page.16
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Tag/Address Assignment for FF Devices
For HART : 0 to 15For FF-H1 : 16 to 247
Proprietary info goes here…Page.17
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Printing from Device DTM
Simple “Powerful” Feature which HHT cannot do
Proprietary info goes here…Page.18
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Differentiating FUNCTION use for HART & FF
• Segment Viewer• Device Viewer• DTM• Parameter Manager• DD Menu
Whichis BEST for use ?
Proprietary info goes here…Page.19
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Contributing to Project Commissioning Phase
Verify Tag
Confirm Configuration- Upper Range Values- Lower Range Values- Engineering Units- Damping
Confirm Device Materials- Diaphragm- Flanges- O rings- Fill Fluids
Check zero
Checking secondary value
Loop Test
FASTER CHECKOUT OF DEVICE
Checking configuration against Documentations
Proprietary info goes here…Page.20
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Contributing to Lower Life Cycle Costs
Manage maintenance remotely Reduce unnecessary maintenance activities
MaintenanceChange configurationPerform calibrationChecks Device Status and AlertsReduce troubleshooting time
Opening multiple device viewerto help reduce troubleshootingtime
Proprietary info goes here…Page.21
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Summary
All HART device DD and Generic DTM
All FF-H1 device DD
Yokogawa device Custom DTM (5 devices)
No “Apple to Apple” comparision against other FDT application & HHT.
Use as “Trojon Horse” for competitive site, more careful about ABB
Proprietary info goes here…Page.22
<Document Number>Copyright © Yokogawa Electric Corporation<date/time>
FORINTERNALUSE
Action Plan
Mailing of Fieldmate flyer- mass distribution- include in proposal ( project, MRO )
Fieldmate site demo for 1 to 1 promotion to customer
Convert all HHT enquiry into Fieldmate
Sell to EPC ( maybe bundle )
Recommended