View
230
Download
3
Category
Preview:
Citation preview
Valent is a business of Unison® Comfort Technologies.
®
Direct and Indirect Fired Make Up Air Units by Valent
Valent is pleased to introduce heat only direct fired and indirect fired make up air units. These units are designed for commercial or industrial facilities where high outdoor air volumes are needed but cooling and humidity control are not required.
FEATURES• Available with direct or indirect fired
heating options
• Available with vertical or horizontal discharge configuration
• Standard casing design includes 1" double wall construction and painted exterior for 1000 hour salt spray
• Removable doors for easy access and maintenance
• Factory run testing on all units
• Discharge or space temp control
• 4:1 turn town for indirect furnaces or 25:1 for direct fired
• Many available options and accessories
BENEFITS• Higher efficiencies available with direct
fired units and tight discharge control with modulating heaters
• Factory test ensure smooth installation
• Cabinet construction provides a longer service life of the equipment
• Flexible arrangements and optional features provide a highly configurable selection
VLT-DS-04 1/13
Contact your Valent representative today for more information.
www.valentair.com
60 28TH AVENUE NORTH, SUITE 100
MINNEAPOLIS, MINNESOTA 55411
T – 612.877.4850
THE VALENT ADVANTAGEValent Air Management Systems is a manufacturer of feature-rich pre-engineered ventilation equipment designed to address the needs of building owners, specifying engineers, and installing contractors. Valent units are built on a foundation of four key attributes: premium quality construction, comprehensive packaging, a thorough run-testing program, and powerful and flexible controls packages.
®
INDIRECT GAS UNITIGR Models are available in horizontal or vertical discharge and can be configured for 100% outside air or with recirculation. Mixing box dampers can be modulating or two position.
DIRECT GAS UNITDGR Models are available in horizontal or vertical discharge and can include a filtered weather hood, louvered weather hood with filters or a weather hood with bird screen.
MIN CFM MAX CFM MIN MBH MAX MBH
DGR-100 800 3000 120 400
DGR-200 2600 6500 395 800
DGR-300 6500 15000 990 1600
MIN CFM MAX CFM MIN MBH MAX MBH
IGR-100 800 2400 75 175
IGR-200 1500 3000 200 300
IGR-300 2000 7000 325 400
A B CD
WIDTHFiltered Louvered Birdscreen
DGR-100 33.75 78.25 27.75 31.75 27.5 26.25 28
DGR-200 33.75 86.25 30.25 34.75 30.25 32.25 37
DGR-300 42.5 101.75 33 65.25 33.25 28.25 48
AB C
WIDTH100% OA Recirc Filtered Louvered
IGR-100 36 73.25 90 26 11.5 43.5
IGR-200 36 76.25 93 26 11.5 52.5
IGR-300 36 85.25 102 26 11.5 52.5
Recommended