7/30/2019 Design Examples Mega Columns
1/74
DESIGN EXAMPLE OF A COLUMN WITH 4 ENCASED STEEL PROFILES
Andr Plumier (Plumiecs & ULg) :a.plumier@ulg.ac.be(Main Contact)
Teodora Bogdan (ULg) :teodora.bogdan@ulg.ac.be
Herv Dege (ULg) :h.degee@ulg.ac.be
Jean-Claude (JC) Gerardy ArcelorMittal Commercial Sections (Luxembourg) :jc.gerardy@arcelormittal.com
Abstract
Composite mega columns of tall buildings are currently designed with continuous built-up sections, welded in
the fabrication shop and spliced on the job site without any prequalified welding procedure. This leads to highly
restrained welds and splices which, under severe dynamic loadings, will likely crack before exhibiting any
ductile behavior. These tall buildings have not been submitted to severe earthquakes, but it will happen. The
1994 earthquake in Northridge, California, taught us that welding procedures, beam-to-column connections and
column splices have to be as simple as possible to properly and reliably work as anticipated.Using multiple rolled sections encased into concrete is the solution for increasing the safety of tall buildings. It
leads to less welding, less fabrication works and reliable simple splices which have been used for decades in
high-rise projects.
AISC allows engineers to design composite sections built-up from two or more encased steel. But, it doesnt
explain how to perform and check the design. This paper offers a method to do it. The method is explained by
means of design examples covering combined axial compression, bending and shear.
Keywords
Composite columns, rolled sections, steel shapes, tall buildings, design method, mega-columns.
7/30/2019 Design Examples Mega Columns
2/74
1
NOTATIONS
Aa = area of 1 steel profile.
Ac = area of concrete.
Ag = gross cross-sectional area of composite section.
As = total area of the steel profiles.
As1 = equivalent steel plate placed along the x-axis.
As2 = equivalent steel plate placed along the y-axis.
Asr= area of the continuous reinforcing bars.
Asri = cross-sectional area of reinforcing bar I.
Asrs = area of continuous reinforcing bars.
Avz = web area of the steel profile.
b = width of the steel profile.
h = height of the steel profile.
bs1 = width ofAs1 plate, mm.
bs2 = width ofAs2 plate, mm.
cx = concrete cover, on x direction.
cy = concrete cover, on y direction.
db = diameter of the longitudinal reinforcement.
dx = the distance between the two steel profiles HD 400x1299 (W14x16x873), on y - direction.
dy = the distance between the two steel profiles HD 400x1299 (W14x16x873), on x - direction.
dsx = the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the section neutral
axis, on x - direction.
dsy = the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the section neutral
axis, on y direction.
ds2x = the distance from the local centroid ofAs1 plate to the section neutral axis, on x - direction.
ds1y= the distance from the local centroid ofAs2 plate to the section neutral axis, on y - direction.
fc = compressive cylinder strength of concrete.
Fy = specified minimum yield stress of steel shape.
Fysr= yield stress of reinforcing steel.
Fu = specified minimum tensile strength of steel shape.
h1 = height of the concrete section.
h2 = width of the concrete section.
hs1 = height ofAs1 plate, mm.
hs2 = height ofAs2 plate, mm.
hnx= distance from centroidal axis (Y-Y) to neutral axis .
hny= distance from centroidal axis (X-X) to neutral axis .
Ic = moment of inertia of concrete.
Ir= moment of inertia of reinforcing steel.
Is= moment of inertia of steel shape.
7/30/2019 Design Examples Mega Columns
3/74
2
Isr1x = moment of inertia about x axis ofAs1 plate, mm.
Isr2x = moment of inertia about x axis ofAs2 plate, mm.
Isr1y = moment of inertia about y axis ofAs1 plate, mm.
Isr2y = moment of inertia about y axis ofAs2 plate, mm.
Isrx = moment of inertia about x axis of equivalent plates, mm.
Isry = moment of inertia about y axis of equivalent plates, mm.
n = number of continuous reinforcing bars in composite section.
nx = number of continuous reinforcing bars on x direction.
ny = number of continuous reinforcing bars on y direction.
tf= steel profile flange thickness.
tw= steel profile web thickness.
Zr1x = full x-axis plastic modulus ofAs1 plate, mm.
Zr2x = full x-axis plastic modulus ofAs2 plate, mm.
Zr1y = full y-axis plastic modulus ofAs1 plate, mm.
Zr2y = full y-axis plastic modulus ofAs2 plate, mm.
Zsx = full x-axis plastic modulus of steel shape, mm.
Zsy = full y-axis plastic modulus of steel shape, mm.
Zcx = full x-axis plastic modulus of concrete shape, mm.
Zcy = full y-axis plastic modulus of concrete shape, mm.
cxnZ = x-axis plastic modulus of concrete section within the zone 2hn
r2xnZ = x-axis plastic modulus ofAs2 plates within the zone 2hn
cynZ = y-axis plastic modulus of concrete section within the zone 2hn
r1ynZ = y-axis plastic modulus ofAs1 plates within the zone 2hn.
= steel contribution ratio.
7/30/2019 Design Examples Mega Columns
4/74
3
Preface
Mega composite columns of tall buildings in Asia are typically designed with huge steel continuous caissons
built-up from heavy plates. They are welded together in the steel fabrication shop and spliced on the job site.
Internationally recognized welding codes such as AWS D1.1 (structural American welding code) and AWS
D1.8 (seismic welding code) or EN 1090-2:2008 (execution of steel structures) and EN 1011-2:2001
(recommendations for welding of metallic materials) impose the pre-qualification of the welding procedures of
such exotic joints, following strict welding sequences. Required preheating and interpass temperatures are
specified per the thickness of the steel (>32mm), its composition (CEV/grade), the type of electrode and the
level of restraint in the joint. Non-destructive tests (ultrasonic test, magnetic particle examination, radiographic
test) performed by certified inspectors are mandatory to guarantee sound welded connections and a safe
structure.
In practice, even when the welding codes are strictly followed, it is typical to have to repair up to 10% of the
welds in simple structures.
In the case of these huge caissons, the welding conditions are rather extreme. Heavy thick plates in typical grade
50 steel (ASTM A572Gr.50 or Q345) must be preheated at 110C in the steel fabrication shop as well as on the
job site prior and during the welding process. Any lack of preheating when welding these huge caissons induces
sensitive material conditions (hard and brittle zones) and high levels of restraint (post weld stresses) in all
directions starting in the steel fabrication shop and amplified on the job site after splicing two caissons together.
Applying adequate preheating during the whole welding process is difficult. How to preheat such joints at
110C? Correct welding takes days of work without interruption. Proper controlling and repair of all welds is so
expensive that this solution, when correctly executed, is not economical at all.
There is an economical and safer alternate to this configuration. AISC design codes allows designers to use
composite sections built-up from two or more encased steel shapes provided that the buckling of individual
shapes is prevented before the hardening of the concrete.
7/30/2019 Design Examples Mega Columns
5/74
4
The Chinese Institute of Earthquake Engineering is also recommending the use of multiple jumbo H-shapes
rather than large continuous caissons. The welding procedures and the connection detailing of single rolled-H-
sections are well described in the above mentioned codes. The use of correct beveling, the so-called "weld-
access-holes" associated to very precise welding sequences, including the removal of the backing bars and
appropriate grindings to clean-up the weld surface between passes minimize the amount of residual stresses after
splicing single rolled steel columns. W14x16 (HD400) rolled sections (jumbos) are today available up to 1299
kg/m (873 lbs/ft) with a flange thickness of 140 mm (5.5 in.) and W36 (HL920) are available up to 1377 kg/m
(925 lbs/ft). These sizes are not only available in classical grade 345 MPa (ASTM A992/Grade 345, Q345,
S355) which requires to be preheated for flange thicknesses above 32 mm (1.5 in.) but also in high tensile
modern steel produced by a quenching and self tempering process, namely ASTM A913 Grade 345 and 450, or
per ETA 10-156 (European Technical Approval) grades Histar 355 and Histar 460. Besides their higher yields,
the main advantages of these high performance steels are their weldability without preheating (above 0C and
with low hydrogen electrodes) as well as their outstanding toughness. (27J up to minus 50C). These high
performance steels are not only fully in compliance with American and European standards, they can also meet
the stringent requirements of the Chinese standards such as the 20% minimum elongation which is mandatory in
the Chinese seismic codes. These QST steels (ASTM A913) have already been successfully used in the
Shanghai World Financial Center.
In this paper, a method for the design of composite sections with multiple encased steel profiles is presented. It
make use of existing principles and calculations methods, but the fact is that the method as such does is not
presented up to now in books of structural design.
7/30/2019 Design Examples Mega Columns
6/74
5
Introduction.
The design examples presented hereafter have as main references:
- ANSI/AISC 360-10 Specification for Structural Steel Buildings, 2010- AISC DESIGN EXAMPLES Version 14.0,2011- Building Code Requirements for Structural Concrete ACI 318-08, 2008
Occasionally, reference is made to EN 1994-1-1:2004 Eurocode 4: Design of composite steel and concrete
structures, part 1-1, general rules and rules for buildings, European Committee for Standardization (CEN),
Brussels, Belgium.
Recall of AISC rules for design of composite members and introduction to
the design examples of composite columns with several steel profiles
encased.
Recall of AISC rule in I4. SHEAR.
For filled and encased composite members, either the shear strength of the steel section alone, the steel section
plus the reinforcing steel, or the reinforced concrete alone are permitted to be used in the calculation of available
shear strength.
The explanations and justifications of the design for shear resistance in the case of a composite column with 4
encased steel profiles are given within Examples I.X3 and I.X4.
Recall of AISC rule in I5. COMBINED FLEXURE AND AXIAL FORCE.
Design for combined axial force and flexure may be accomplished using the plastic-distribution method.
Several different procedures for employing the plastic-distribution method are outlined in the AISC
Commentary to I5.
Each of these procedures is applied for composite steel-concrete sections concrete with 4 encased steel profiles
in Example I.X1. and Example I.X2.
To help in following these design examples, the interaction curves which will be used are presented separately
in Fig. I-1e and I-1f. The equations correspond to different points selected on the interaction curves.
Calculations concerning the slenderness effect are not presented, because they would not be different of those
7/30/2019 Design Examples Mega Columns
7/74
6
shown in detail in AISC Design Examples V14.0-2011. For design cases which would be different of the
examples presented (for instance a section with 6 encased steel profiles, this presentation in Figures I-1e and I-
1f shows the way to develop the appropriate interaction equations.
In the plastic-distribution method, the N-M interaction curves are convex, because it is assumed that the
concrete has no tensile strength.
Fig.I-1. Axial force (P) bending moment (M) diagram for a composite cross section.
For a composite cross-section symmetrical about the axis of bending, Roik and Bergmann (1992) have proposed
a simple method to evaluate its M-N interaction diagram. This method is adopted in AISC Specifications. As
shown in Figure I-1, this method does not determine a continuous N-M interaction curve, but only a few key
points. The N-M curve is then constructed by joining these key points by straight lines.
When evaluating these key points, rigid-plastic material behavior is assumed. Thus, steel is assumed to have
reached yield in either tension or compression. Concrete is assumed to have reached its peak stress in
compression and its tensile strength is zero. For one equivalent rectangular stress block the peak stress in
compression is:
'
c0.85 0.85 50MPa 42.5 MPaf = =
The key points in Fig.I-1are:
- A - squash load point- B - pure flexural bending point- D - the maximum bending moment point- C - point with bending moment equal to the pure bending moment capacity
7/30/2019 Design Examples Mega Columns
8/74
7
PLASTIC CAPACITIES FOR RECTANGULAR,
COLUMN WITH 4 ENCASED PROFILES
BENT ABOUT THE X X AXIS
Section Stress distribution oint Defining Equations
1 1 1= = s x sri s sA n A b h
2 2 2 2= = s y sr s sA n A b h
( )= + sr x y sriA n n A nx no. of bars on x directionny no. of bars on y directionbs1= width ofAs1 platehs1= height ofAs1 platebs2= width ofAs2 platehs2= height ofAs2 plate
As1 = area of top (bottom) plateAs2 = area of lateral plate
Asri = area of one longitudinal barA
0.85A s y s1 ysr s2 ysr c cP A F A F A F A f' = + + + 0
AM =
4s aA A=
2C 1 s sr A h h A A= Aa = area of one steel profileAs = total area of the steel shape
C
0.85C c c
P A f' =
C BM M=
D 0.85
2
c c
D
A f'P
=
( ) ( )1
0.852
'
Dx sx y r1x r2x ysr cx cM Z F Z Z F Z f= + + + Zsxfull x- axis plastic modulus of steel shapeZr1x full x- axis plastic modulus ofAs1 platesZr2x full x- axis plastic modulus ofAs2 plates
2r1x s1 s1y
Z A d=
24
2
s2 s2r2x
b hZ =
4sx a syZ A d=
r2 xZ4
2
1 2
cx r1x sx
h hZ Z Z
=
Fig. I -1e. Composite member with several encased steel profiles, X-X -axis anchor points.
7/30/2019 Design Examples Mega Columns
9/74
8
B 0BP =
aA
b*h
=
where:b* - the width of the equivalent steel rectangle bar
Aa area of one steel profile
For hnx between the two profiles2
nx sy
hh d
:
( ) ( )1 0.85 2 0.85C
nx
c s2 yrs c
Ph
2 h f' b 2 F f' =
+
2
cxn 1 nx r2xnZ h h Z=
2 2r2xn s2 nxZ b h=
( )1 0.852Bx Dx r2xn yrs cxn cM M Z F Z f'=
For hnx between the two profiles
2 2sy nx sy
h hd h d
< +
:
( )
( ) ( ) ( )1 s2
4 0.852
0.85 4 0.85 2 0.85
C sy y c
nx
c y c yrs c
hP d b* 2 F f'
h2 h f' b* 2 F f' b 2 F f'
+ =
+ +
2 2r2xn s2 nxZ b h=
( ) ( )( )
2
2 2 24
sy
sxn sx nx sx nx
b* 2 d hZ 2 d +b* h 2 d -b* h
=
2
cxn 1 nx r2xn sxnZ h h Z Z=
( )1 0.852Bx Dx r2xn yrs sxn y cxn c
M M Z F Z F Z f'=
For hnx above the two profiles the height of vertical
equivalent layer2 2
s2
sy nxhhd
7/30/2019 Design Examples Mega Columns
10/74
9
PLASTIC CAPACITIES FOR RECTANGULAR,COLUMN WITH 4 ENCASED PROFILES
BENT ABOUT THE Y Y AXIS
Section Stress distribution oin Defining Equations
A
0.85A s y s1 ysr s2 ysr c cP A F A F A F A f' = + + + 0AM =
4s aA A=
2C 1 s sr A h h A A= Aa = area of one steel profileAs = total area of the steel shape
C
0.85C c cP A f' =
C BM M=
D 0.85
2
c cD
A f'P
=
( ) ( )1
0.852
'
Dy sy y r1y r2y ysr cy cM Z F Z Z F Z f= + + + Zsy
full y- axis plastic modulus of steel shapeZr1y full y- axis plastic modulus ofAs1 platesZr2y full y- axis plastic modulus ofAs2 plates
2
s1b24
s1
r1y
dZ
=
s2 x2r2y s2Z A d= 4sy a sxZ A d=
r2 yZ4
2
1 2
cy r1y sy
h hZ Z Z
=
Fig. I -1f. Composite member with several encased steel profiles, Y-Y -axis anchor points.
7/30/2019 Design Examples Mega Columns
11/74
10
B 0BP =
aA
h*b
=
where:h* - the height of the equivalent steel rectangle bar
Aa area of one steel profile
For hny between the two profiles2
ny sx
bh d
:
( ) ( )2 0.85 2 0.85C
ny
c s1 yrs c
Ph
2 h f' b 2 F f' =
+
2
2
cyn ny r1ynZ h h Z=
22
r1yn s1 nyZ b h=
( )1 0.852By Dy r1yn yrs cyn cM M Z F Z f'=
For hny between the two profiles 2 2sx ny sx
b b
d h d
< + :
( )
( ) ( ) ( )2 s1
4 0.852
0.85 4 0.85 2 0.85
C sx y c
ny
c y c yrs c
bP d h* 2 F f'
h2 h f' h* 2 F f' b 2 F f'
+
=
+ +
22
r1yn s1 nyZ b h=
( ) ( )( )
2
2 2 24
sx
syn sy ny sy ny
h* 2 d bZ 2 d +h* h 2 d -h* h
=
2
cyn 1 ny r1yn synZ h h Z Z=
( )1 0.852By Dy r1yn yrs syn y cyn c
M M Z F Z F Z f'=
For hny above the two profiles and the height of
vertical equivalent layer2 2
s1
sx ny
hbd h
+ <
:
( )
( ) ( )
2 0.85
0.85 2 2 0.85
C s y c
ny
2 c s1 yrs c
P A F f' h
2 h f' b F f'
=
+
22
r1yn s1 nyZ b h=
syn syZ Z= 2
cyn 1 ny r1yn synZ h h Z Z=
( )1 0.852By Dy r1yn yrs syn y cyn c
M M Z F Z F Z f'=
synZ - y-axis plastic modulus of equivalent steelrectangle bar within the zone 2 hny
cynZ - y-axis plastic modulus of concrete section
within the zone 2hny
r1ynZ - y-axis plastic modulus ofAs1 plates within
the zone 2hny
Fig. I -1f. Composite member with several encased steel profiles, Y-Y -axis anchor points (continued).
7/30/2019 Design Examples Mega Columns
12/74
11
EXAMPLE I.X1 - COMPOSITE COLUMN WITH FOUR ENCASED STEEL PROFILES IN
COMBINED AXIAL COMPRESSION AND FLEXURE ABOUT (X-X) AXIS.
Given:
Determine for the encased composite member illustrates in Fig. I.X1-1 the axial force (P) bending moment
(M) diagram.
Fig. I.X1-1. Encased composite member section.
From ArcelorMittal classification, the steel material properties are:
ASTM A913- 11 Grade 65
Fy = 450MPa;
Fu = 550MPa;
7/30/2019 Design Examples Mega Columns
13/74
12
From ArcelorMittal sections catalog, the geometric and material properties of one steel profile HD 400x1299
(W14x16x873) are:
Aa = 165000 mm2; Avz = 505.2 cm
2;
b = 476 mm; h = 600 mm; tw = 100 mm; tf= 140 mm;
Zsx = 33250 cm
3
; Zsy = 16670 cm
3
;
4 4
754600 10 mmHDxI=
4 4
254400 10 mmHDyI=
From Fig. I.X1-1, additional geometric properties of the composite section used for force allocation and load
transfer are calculated as follows:
h1 = 3072mm; h2 = 3072mm;
cx = 86mm -14mm = 72 mm; cy = 86mm -14mm = 72 mm;
dx = 2500 mm; dy = 2500mm;
dsx = 1012 mm; dsy = 950mm;
ds1y = 1400 mm; ds2x = 1450mm;
2(3072mm) (3072mm) 9437184mmg 1 2A h h= = = ;
db= 40mm for a T40 diameter bar;21256.637mm=sriA ;
n2
i 1
321699.09mm=
= =sr sriA A ;
42 2
i 1
4 165000mm 660000mms a
A A=
= = =;
2 2 2 6 29437184mm 321699.09mm 660000mm 8.455 10 mmc g sr s
A A A A= = =
( ) 3kg
0.043 38007MPa for 2500m
= = =1.5 '
c c c cE w f w
;Es = 200000 MPa (AISC I1.3);
2 2
2
321699.09mm 660000mm0.104
94371.84mm
sr s
g
A A
A
+ += =
( )5 2 5 2 6 20.85
6.6 10 mm 450MPa 3.216 10 mm 500MPa 8.455 10 mm 0.85 50MPa
817207.653kN
n s y sr ysr c cP A F A F A f'
= + +
= + +
=
2y 660000mm 450MPa
0.363817207.653kN
s
n
A F
P
= = =
where
h1 height of the concrete section, mm.
h2 width of the concrete section, mm.
cx concrete cover, on x direction, mm.
cy concrete cover, on y direction, mm.
dx the distance between the two steel profiles HD 400x1299 (W14x16x873), on y - direction, mm.
dy the distance between the two steel profiles HD 400x1299 (W14x16x873), on x - direction, mm.
dsx the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the
section neutral axis, on x - direction, mm.
7/30/2019 Design Examples Mega Columns
14/74
13
dsy the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the
section neutral axis, on y direction, mm.
ds2x the distance from the local centroid of As1 plate to the section neutral axis, on x - direction, mm.
ds1y the distance from the local centroid of As2 plate to the section neutral axis, on y - direction, mm.
Solution:
A simplification of the composite section is made by replacing the reinforcement by equivalent steel plates, as
shown in Fig. I.X1-1. Horizontal plates include only reinforcement that belongs to the two main lines. One
horizontal plate,As1, replace 52 reinforcement rebars.
52=xn 2 2
52T40 52 1256.64mm 65364mm= = =s1
A;
For100
3072mm (86mm mm) 2800mm
2
= + =s1h
bs1 = 23.338 mm;
2800mm1400mm
2 2
s1
s1y
hd = = =
Side plates includes besides the two lateral lines, the few additional rebars. The number of reinforcement which
corresponds to one lateral plate is 76.
30 30 3 2 5 2 76y
n = + + + =
2 276T40 76 1256.64mm 95532mms2A = = = ;
For 3072mm 2 86mm 2900mms2
h = = bs2 = 32.933 mm;
2900mm
1450mm2 2
s2
s2x
h
d= = =
The moment of inertia of the reinforcing bars about the elastic neutral axis of the composite section, Isr, is
determined for the two equivalent plates As1 and As2, and is calculated as follows:
( )3
6 42800mm 23.338mm
2.966 10 mm12 12
3
s1 s1
sr1x
h bI
= = =
;
( )3
10 432.933mm 2900mm
6.693 10 mm12 12
3
s2 s2
sr2x
b hI
= = =
;
( )26 4 10 4 4 2
11 4
2 2 2
2 2.966 10 mm 2 6.693 10 mm 2 6.534 10 mm 1400mm
3.9 10 mm
2
srx sr1x sr2x s1 s1yI I I A d
=
= + + =
+ +
=
;
where
Isr1x moment of inertia about x axis ofAs1 plate, mm4.
Isr2x moment of inertia about x axis ofAs2 plate, mm4.
Isrx moment of inertia about x axis of equivalent plates, mm4.
hs1 height ofAs1 plate, mm.
bs1 width ofAs1 plate, mm.
7/30/2019 Design Examples Mega Columns
15/74
14
hs2 height ofAs2 plate, mm.
bs2 width ofAs2 plate, mm.
The moment of inertia values of the entire steel section about X-X is determined as:
( )22 4 4 11 4
HDx4 4 I 4 165000mm 950mm 4 754600 10 mm 6.258 10 mm2
sx a syI A d= + = + =
where
Isx moment of inertia about x axis of the steel profiles, mm4.
The moment of inertia values for the concrete about both axes axis is determined as:
( )3
12 423072mm 3072mm
7.421 10 mm12 12
3
1g
h hI
= = =
12 4 11 4 11 4 12 47.421 10 mm 3.9 10 mm 6.058 10 mm 6.426 10 mmcx g srx sxI I I I= = =
where
Icx moment of inertia about x axis of the concrete part, mm4.
Material and Detailing Limitations
Material limits are provided in AISC Specification Sections I1.1 (2) and I1.3 as follows:
(1) Concrete strength: 21MPa 70MPacf'
50MPacf' = o. k.
(2) Specified yield stress of structural steel: 525MPayF
450MPayF = o. k.
(3) Specified yield stress of structural steel: 525MPaysrF
500MPaysrF = o. k.
Transverse reinforcement limitations are provided in AISC Specification Section I1.1 (3), I2.1a. (1), I2.1a. (2)
and ACI 318 as follows:
(1) Tie size and spacing limitations:
The AISC Specifications requires that either lateral ties or spirals be used for transverse reinforcement.
Where lateral ties are used, a minimum of either 10 mm (No. 3) bar placed at a maximum of 406 mm
(12 in.) on center, or a 13 mm (No. 4) bar or larger spaced at a maximum of 406 mm (16 in.) on center
shall be used.
14 mm lateral ties at 75 mmare provided. o. k.
Note that AISC Specification Section I1.1 (1) specifically excludes the composite column provision of
ACI 318 Section 10.13, so it is unnecessary to meet the tie reinforcement provisions of ACI 318
Section 10.13.8. when designing composite columns using AISC Specifications Chapter I.
If spirals are used, the requirements of ACI 318 Sections 7.10 and 10.9.3 should be met according to
the User Note at the end of AISC Specification I2.1a.
7/30/2019 Design Examples Mega Columns
16/74
15
(2) Additional tie size limitation:
ACI 318 Section 7.10.5.1 requires that all nonprestressed bars shall be enclosed by lateral ties, at least
10 mm (No. 3) in size for longitudinal bars 32 mm (No. 10) or smaller, and at least 13 mm (No. 4) in
size for 36 mm (No. 11), 43 mm (No. 14), 57 mm (No. 18), and bundled longitudinal bars.
14 mm lateral ties are provided for 40 mm longitudinal bars. o. k.(3) Maximum tie spacing should not exceed 0.5 times the least column dimension:
3072mm0.5 min 1536mm
3072mm
1
max
2
hs
h
= = =
=
75mm 1536mmmaxs s= = o. k.
(4) Concrete cover:
ACI 318 Section 7.7 contains concrete cover requirements. For concrete not exposed to weather or in
contact with ground, the required cover for column ties is 38 mm (1.5 in).
cover 86mm-1T14 86mm-14mm 72mm 38mm= = = > o. k.
(5) Provide ties as required for lateral support of longitudinal bars:
AISC Design Examples 2011 Part1, page I-96 indicates the following:AISC Specification Commentary
Section I2.1a references Chapter 7 of ACI 318 for additional transverse tie requirements. In accordance
with ACI 318 Section 7.10.5.3 and Fig. R7.10.5, ties are required to support longitudinal bars located
farther than 6 in. clear on each side from a laterally supported bar. For corner bars, support is typically
provided by the main perimeter ties. For intermediate bars, Fig. I.9-1illustrates one method for
providing support through the use of a diamond-shaped tie.
Longitudinal and structural steel reinforcements limits are provided in AISC Specification Section I1.1 (4), I2.1
and ACI 318 as follows:
(1) Structural steel minimum reinforcement ratio: / 0.01s gA A
5 2
6 2
6.6 10 mm0.070mm
9.437 10 mm
=
o. k.
(2) Minimum longitudinal reinforcement ratio: / 0.004sr gA A
5 2
6 2
3.216 10 mm0.034mm
9.437 10 mm
=
o. k.
(3) Maximum longitudinal reinforcement ratio: / 0.08sr gA A
5 2
6 2
3.216 10 mm0.034mm
9.437 10 mm
=
o. k.
(4) Minimum number of longitudinal bars:ACI 318 Section 10.9.2 requires a minimum of four longitudinal bars within rectangular or circular
members with ties and six bars for columns utilizing spiral ties. The intent for rectangular sections is to
provide a minimum of one bar in each corner, so irregular geometries with multiple corners require
additional longitudinal bars.
256 bars provided o. k.
(5) Clear spacing between longitudinal bars:
7/30/2019 Design Examples Mega Columns
17/74
16
ACI 318 Section 7.6.3 requires a clear distance between bars of 1.5db or 38 mm (1.5in.).
1.5 60mmmax 60mm
38mm
b
min
ds
= = =
100mm 40mm 60 mins s= = o. k.
(6) Clear spacing between longitudinal bars and the steel core:
AISC Specification Section I2.1e requires a minimum clear spacing between the steel core and
longitudinal reinforcement of 1.5 reinforcing bar diameters, but not less than 38 mm (1.5 in.).
1.5 60mmmax 60mm
38mm
b
min
ds
= = =
The distance from the steel core and the longitudinal bars is determined from Fig. IX1-1, on x direction
as follows:
524mm 60mm 2 40mm 146mm2
min
bs s= = o. k.
The distance from the steel core and the longitudinal bars is determined from Fig. IX1-1, on y direction
as follows:
586mm 60mm 2 40mm 100mm2
min
hs s= = o. k.
where
h height of HD 400x1299 (W14x16x873) steel profile, mm.
b width of HD 400x1299 (W14x16x873) steel profile, mm.
(7) Concrete cover for longitudinal reinforcement:
ACI 318 Section 7.7 provides concrete cover requirements for reinforcement. The cover requirements
for column ties and primary reinforcement are the same, and the tie cover was previously determined to
be acceptable, thus the longitudinal reinforcement cover is acceptable by inspection.
Interaction of Axial Force and Flexure
AISC Design Examples 2011 Part1, page I-96 indicates the following:
The interaction between axial forces and flexure in composite members is governed by AISC
Specification Section I5 which, for compact members permits the use of a strain compatibility method
or plastic stress distribution method, with the option to use the interaction equations of Section H1.1.
The strain compatibility method is a generalized approach that allows for the construction of an
interaction diagram based upon the same concepts used for reinforced concrete design. Application of
the strain compatibility method is required for irregular/nonsymmetrical sections.
Plastic stress distribution methods are discussed in AISC Specification Commentary Section I5 which
provides three acceptable procedures for filled members. Plastic stress distribution methods are
discussed in AISC Specification Commentary Section I5. The procedure involves the construction of a
piecewise-linear interaction curve using the plastic strength equations provided in Fig. I-1-1 located
7/30/2019 Design Examples Mega Columns
18/74
17
within the front matter of the Chapter I Design Examples. The method is a reduction of the piecewise-
linear interaction curve that allows for the use of less conservative interaction equations than those
presented in Chapter H.
Thereafter are provided approaches following two methods: a plastic stress distribution method and a finite
element analysis.
Method1 - Interaction Curves from the Plastic Stress Distribution Model
Step 1: Construct nominal strength interaction surface A, B, C, and D without length effects, using the equations
provided in Fig. I-1e for bending about the X-Xaxis:
Point A (pure axial compression): the available compressive strength is calculated as illustrated in Design
Example I.9.
( )5 2 5 2 6 20.85
6.6 10 mm 450MPa 3.216 10 mm 500MPa 8.455 10 mm 0.85 50MPa
817207.653kN
A s y sr ysr c cP A F A F A f'
= + +
= + +
=
0kNmAM =
Point D (maximum nominal moment strength):
( )6 2
0.85
2
8.455 10 mm 0.85 50MPa
2
179679.054kN
c c
D
A f'P
=
= =
=
The applied moment, illustrated in Fig. I -1e, is resisted by the flexural strength of the composite section about
its X-X axis. The strength of the section in pure flexure is calculated using the equations of Fig. I-1e found in
the front matter of the Chapter I Design Examples for Point B. Note that the calculation of the flexural strength
at Point B first requires calculation of the flexural strength at Point D as follows:
4 4 8 32 2 6.534 10 mm 1400mm 1.83 10 mmsr1x s1 s1yZ A d= = = ;
( )2
8 332.933mm 2900mm
2 2 1.385 10 mm4 4
2
s2 s2
sr2x
b hZ
= = =
;
8 3 8 3 8 31.83 10 mm 1.385 10 mm 3.21 10 mmsrx sr1x sr1xZ Z Z= + = + =
5 4 8 3
4 4 1.65 10 mm 950mm 6.27 10 mmsx a syZ A d= = =
;
( )
2
2
2
8 3 8 3 8 3
9 3
43072mm 3072mm
1.83 10 mm 1.385 10 mm 6.27 10 mm4
6.299 10 mm
1
cx sr1x sr2x sx
h hZ Z Z Z
=
=
=
;
where
Zsr1x full x-axis plastic modulus ofAs1 plate, mm3.
7/30/2019 Design Examples Mega Columns
19/74
18
Zsr2x full x-axis plastic modulus ofAs2 plate, mm3.
Zsrx full x-axis plastic modulus ofAs1 andAs2 plate, mm3.
Zsx full x-axis plastic modulus of steel shape, mm3.
Zcx full x-axis plastic modulus of concrete shape, mm3.
The bending moment of a composite cross-section is taken about the axis of symmetry. Therefore, the maximum
bending moment is obtained by placing the plastic neutral axis at the axis of symmetry of the composite cross-
section. This conclusion can be obtained by examining the change in the bending moment of the composite
cross-section by making a small change in the position of the plastic neutral axis. The coefficient of in front
of the concrete part is a result on the assumption that concrete has no tensile strength and only the compressive
strength contributes to the bending moment capacity [Nethercot D.A., 2004].
( ) ( )
( ) ( )8 3 8 3 8 3 9 3
5
10.85
21
6.27 10 mm 450MPa 1.83 10 mm 1.385 10 mm 500MPa 6.299 10 mm 0.85 50MPa2
5.767 10 kNm
'
Dx sx y sr1x sr2x ysr cx cM Z F Z Z F Z f
=
= + + +
= + + +
Point B (pure flexure):
0kNB
P =
The stress distribution point C from Fig. I1e provides the same moment resistance as B, since the moment from
the stress resultants cancel each other. However, the resulting resistance to axial force is of the same magnitude
from the pure concrete part 'c0.85 f . This can be seen from adding up the stress distribution in B and C, with
regard to the equilibrium of forces, by example the resulting axial force. This follows because the resistance to
axial force in B is zero. Subtracting the stress distributions of B from that of C it results the value of hnx.
In order to determine the position of the neutral axis on X-X direction, the HD 400x1299 steel profile has been
considered as a rectangle bar (h x b*) with an equivalent area, as shown in Fig. I.X1-2a.
165000mm275mm
600mm
aA
b*=h
= =;
where
h the height of the HD 400x1299 steel profile
7/30/2019 Design Examples Mega Columns
20/74
19
Fig. I.X1-2a. Subtracting the components of the stress distribution combination at point B and C considering
normal force only, when the a.n.is between the profiles.
Assumption 1: the neutral axis is placed between the steel profiles2
nx sy
hh d
:
( ) ( )10.85 359358.109kN
2 0.85 2 2 0.85C B C c c
nx c nx s2 yrs c
P P P A f'
= h h f' h b F f'
= = =
+
( ) ( )
( ) ( )
1 0.85 2 2 0.85
359358.109kN
3072mm 0.85 50MPa 2 32.933mm 2 500MPa 0.85 50MPa
1.108m
C
nx
c s2 yrs c
Ph
2 h f' b F f'
=2
=
+
+
=
Check assumption2
nx sy
hh d
:
1108mm 650mm2
nx sy
hh d= =
assumption not. k.
Assumption 2: the neutral axis is placed within the steel profiles2 2
sy nx sy
h hd
7/30/2019 Design Examples Mega Columns
21/74
20
Fig. I.X1-2b. Subtracting the components of the stress distribution combination at point B and C considering
normal force only, when the a.n.is within the profiles.
( ) ( ) ( )1 nx
0.85 359358.109kN
0.85 4 2 0.85 2 2 0.852
C B C c c
nx c nx sy y c s2 yrs c
P P P A f'
h= 2 h h f' h d b* F f' h b F f'
= = =
+ +
( )
( ) ( ) ( )
( )
( )
1 s2
4 0.852
0.85 4 0.85 2 0.85
600mm359358.109kN 4 950mm 275mm 2 450MPa 0.85
2
3072mm 0.85 50MPa 4 275mm 2 450MPa 0.85
C sy y c
nx
c y c yrs c
c
hP d b* 2 F f'
h2 h f' b* 2 F f' b 2 F f'
f'
=2 f
+
=
+ +
+
+ ( ) ( )2 32.933mm 2 500MPa 0.85
767mm
c c' f'
+
=
Check assumption2 2
sy nx sy
h hd
7/30/2019 Design Examples Mega Columns
22/74
21
( )
( )7 3 7 3 9 3
1 0.852
1576734.208kNm 3.878 10 mm 500MPa 9.141 10 mm 450MPa 1.687 10 mm 0.85 50MPa
2
480546kNm
Bx Dx r2xn yrs sxn y cxn cM M Z F Z F Z f'
=
=
=
where
cxnZ - x-axis plastic modulus of concrete section within the zone 2hn, mm
3.
sxnZ - x-axis plastic modulus of equivalent rectangle bar within the zone 2hn, mm3.
sr2xnZ - x-axis plastic modulus ofAs2 plates within the zone 2hn, mm
3.
Point C (intermediate point):
6 2
0.85
0.85 8.455 10 mm 50MPa
359358.109kN
C c cP A f'
=
= =
=
480546kNmCx BxM M= =
The available compressive and flexural strengths are determined as follows:
LFRD ASD
Design compressive strength:
0.75C
=
where
X" C XP P
X = A,B,C or D
=
0.75 817207.65kN 612905.739kN
A" C AP P
=
= =
0.75 0kN 0kN
B" C BP P
=
= =
0.75 359358.109kN 269518.582kN
C" c C P P
=
= =
0.75 179679.054kN 134759.291kN
D" c DP P
=
= =
Allowable compressive strength:
C 2.00=
where
X
X"
C
PP
X = A,B,C or D
=
817207.65kN408603.826kN
2
AA"
c
PP
=
= =
0kN0kN
2
BB
c
PP
=
= =
C
359358.109kN179679.055kN
2
C"c
PP
=
= =
D
179679.054kN89839.53kN
2
D"
c
PP
=
= =
7/30/2019 Design Examples Mega Columns
23/74
22
Design flexural strength:
0.90B =
where
X" B XM M
X = A,B,C or D
=
0.9 0kNm 0kNm
Ax" B AxM M
=
= =
0.9 480546kNm 432491kNm
Bx" B BxM M
=
= =
0.9 480546kNm 432491kNm
Cx" B CxM M
=
= =
0.90 576734.208kNm 519060.787kNm
Dx" B DxM M
=
= =
Allowable compressive strength:
b 1.67=
b
where
XX"
MM
X = A,B,C or D
=
b
0kNm0kNm
1.67
Ax
Ax"
MM
=
= =
b
480546kNm287752kNm
1.67
Bx
Bx"
MM
=
= =
b
480546kNm287752kNm
1.67
Cx
Cx"
MM
=
= =
b
576734.208kNm345349.825kNm
1.67
Dx
Dx"
MM
=
= =
The design and allowable strength values are plotted in Fig. I.X1-3.
Fig. I.X1 -3. Available and nominal interaction surfaces.
7/30/2019 Design Examples Mega Columns
24/74
23
Method2 FEM Results
A numerical model using finite elements is considered with the purpose of comparison and validation of the
simplified method. The software package is FineLg, developed in collaboration between University of Lige
and Engineering office Greisch [FineLg Users Manual, V 9.2. 2011]. This numerical tool is continuously being
developed since the 70's and has been validated in a number of PhD theses and research reports. Specific
concrete beam elements have been developed by Ph. Boeraeve [Boeraeve P., 1991].
The chosen finite element is a 2D Bernoulli fiber element with 3 nodes and 7 degrees of freedom (DOF). The
total number of DOF corresponds to one rotational and two translational DOF for the nodes located at beam
element ends (nodes 1 and 3 in Fig. I.X1-4) and one relative longitudinal translational DOF for the node situated
at mid-length of the beam element (node 2 in Fig. I-X1-4). The relative translational DOF of the node at beam
mid-length has been proven necessary to take into account the strong variation of the centroid position along the
beam when the behaviour of the section is not symmetrical. Such a situation happens for instance in concrete
sections as soon as cracking occurs. The beam elements are able to simulate structures undergoing large
displacements but small deformations. They are developed following a co-rotational total description.
Fig. I.X1 -4. Strain Plane beam finite element with three nodes.
The model is built using an assembly of concrete (with appropriate reservations at the location of the steel
profiles) and steel fibre elements (see Fig. I.X1-6.b). In such fibre elements, only longitudinal strain and stresses
are explicitly modelled. The shear behaviour is supposed to remain elastic. Compatibility of longitudinal strains
is assumed at the interface between concrete and steel elements. This translates mathematically a perfectly rigid
longitudinal connection.
For both concrete and steel elements, internal forces in the elements are computed using a longitudinal and
transverse integration scheme. The integration along the beam length is performed using a classical Gauss
scheme with 4 integration points (see Fig. I.X1 -5.a). Nodal values are then extrapolated from this 4-point
scheme. At each longitudinal integration point (LIP i), a transverse integration is performed using a multilayer
scheme. The section is divided into a number of layers, in which the actual stress state is derived from the strain
state and assuming a uniaxial stress-strain relationship. In this case the cross-section is divided into 29 layers.
7/30/2019 Design Examples Mega Columns
25/74
24
Fig. I.X1 -5. Integration scheme: a) longitudinal integration with 4-point Gauss scheme; b) transversal
integration with multilayer scheme
A parabola-rectangle constitutive law with tension stiffening is assumed for the concrete (EN 1992-1-1-
Eurocode 2, 2004), as shown in Fig.I.X1-6, and is analytically defined as follows:
cc 2ccu ccu
c
c c
f
=
2'
c
c
f
E
=
2
3ct cc
0.3 4.072MPaf f= =.
where:
fcc = 50 MPa compressive strength of unconfined concrete (AISC I1.2b)
fct axial tensile strength of concrete;
ccu = 0.003 ultimate compressive strain of unconfined concrete (AISC I1.2b);
c strain at reaching maximum strength;
E= 38007MPa;
Fig. I.X1-6.Parabola-rectangle diagram for concrete in compression
An elastic perfectly plastic law is used to model the steel material (EN 1994-1-1-Eurocode 4 , 2004), as shown
in Fig. I.X1-7.
Fig. I.X1-7. Bi-linear steel material law.
where:
fy = 450MPA;
E= 200000MPa; (AISC I1.3);
7/30/2019 Design Examples Mega Columns
26/74
25
For both steel and concrete materials, the mechanical properties considered in the numerical simulations are the
nominal values. They should thus compare to the simplified AISC approach also considering nominal values of
the material properties. This comparison is done in Fig. I-XI-11.
The numerical M-N interaction curve is derived from the behaviour of a cantilever column with arbitrary length
l, as shown in Fig. I.X1-8. The column is chosen long enough to ensure that shear effects can be neglected but
not too long to avoid stability problems and second-order (i.e. buckling) effects.
Fig. I.X1-8. FineLg - numerical model.
Accounting for the symmetry of the cross-section, only half of the section is represented, as shown in Fig. I.X1-
9. Results of the FEM analysis are then simply doubled for final post-processing and comparison. The total
height of the composite column is equal to l = 45m. The zone close to the support is the main zone of interest
and needs an accurate meshing. In total there are 17 nodes, 7 elements with a length of 6m, and 1 elementplaced close to the support having 3 m. This shorter element allows a better localization of the plastic hinge.
7/30/2019 Design Examples Mega Columns
27/74
26
Fig. I.X1-9. Meshing.
The column is initially loaded by a compressive axial force N. The compression force is kept constant while a
horizontal load is then increasingly applied until the bending resistance of the column is overcome (see Fig.
I.X1-10). The corresponding resisting moment in the plastic hinge is calculated bymax
H l = . The full curve
is then built by considering different values of the compression force N and by calculating the maximum
bending resistance M corresponding to each value of N.
Fig. I.X1-10. Example of pushover curves obtained with the numerical model for point C of the interaction
curve.
7/30/2019 Design Examples Mega Columns
28/74
27
The following table summarizes the results obtained with the Simple method and the Finite Element model.
Nominal LFRD ASD Nominal LFRD ASD FineLg
P [kN] 0.75 P [kN] P /2 [kN] Mx [kNm] 0.9 Mx [kNm]Mx/1.67 [kNm] Mx
Point B 0 0 0 480546 432491 287752 516060Point D 179679 134759 89839 576734 519060 345349 604391
Point C 359358 269518 179679 480546 432491 287752 510177
Point A 817207 612905 408603 0 0 0 0
Fig. I.X1-11. Comparison between the AISC - Plastic Distribution Method and the FEM method.
Conclusion
Design values of M-N interaction diagram have been obtained on the basis of a simple general methodology
proposed by AISC Specification and from which explicit expressions have been developed for the case of
composite sections with several encased steel profiles; these expressions have been presented in Figures I-1e
and I-1f.
The results of a study carried out with a more accurate FEM model confirm the validity of the results obtained
with the simple method in the case of composite sections with several encased steel profiles. Results obtained
with the simple AISC method using nominal values of the material properties and FEM results are compared on
Fig. I.XI-11. They are in excellent agreement for high compression level and the simple method is reasonably
accurate and safe-sided when bending becomes dominant. The simple method is thus felt sufficient to evaluate
design values of M-N interaction in the present context.
7/30/2019 Design Examples Mega Columns
29/74
28
EXAMPLE I.X2 - COMPOSITE COLUMN WITH 4 STEEL PROFILES ENCASED IN COMBINED
AXIAL COMPRESSION AND FLEXURE OVER (Y-Y) AXIS.
Given:
Determine for the encased composite member illustrated in Fig. IX1-1 the axial force (P) bending moment
(M) diagram.
Fig. I.X2-1. Encased composite member section.
From ArcelorMittal classification, the steel material properties are:
ASTM A913- 11 Grade 65
Fy = 450MPa;
Fu = 550MPa;
7/30/2019 Design Examples Mega Columns
30/74
29
From ArcelorMittal sections catalog, the geometric and material properties of one steel profile HD 400x1299
(W14x16x873) are:
Aa = 165000 mm2; Avz = 505.2 cm
2;
b = 476 mm; h = 600 mm; tw = 100 mm; tf= 140 mm;
Zsx = 33250 cm
3
; Zsy = 16670 cm
3
;
4 4
754600 10 mmHDxI=
4 4
254400 10 mmHDyI=
From Fig. I.X1-1, additional geometric properties of the composite section used for force allocation and load
transfer are calculated as follows:
h1 = 3072mm; h2 = 3072mm;
cx = 86mm -14mm = 72 mm; cy = 86mm -16mm = 70 mm;
dx = 2500 mm; dy = 2500mm;
dsx = 1012 mm; dsy = 950mm;
ds1y = 1400 mm; ds2x = 1450mm;
2(3072mm) (3072mm) 9437184mmg 1 2
A h h= = = ;
db= 40mm for a T40 diameter bar;
21256.637mm=sriA ;
n2
i 1
321699.09mm=
= =sr sriA A ;
42 2
i 1
4 165000mm 660000mms a
A A=
= = =;
2 2 2 6 29437184mm 321699.09mm 660000mm 8.455 10 mm
c g sr sA A A A= = =
( )3
kg
0.043 38007MPa for 2500 m= = =
1.5 '
c c c cE w f w ; Es = 200000 MPa (AISC I1.3);
2 2
2
321699.09mm 660000mm0.104
94371.84mm
sr s
g
A A
A
+ += =
( )5 2 5 2 6 20.85
6.6 10 mm 450MPa 3.216 10 mm 500MPa 8.455 10 mm 0.85 50MPa
817207.653kN
n s y sr ysr c cP A F A F A f'
= + +
= + +
=
2y 660000mm 450MPa
0.363817207.653kN
s
n
A F
P
= = =
where
h1 height of the concrete section, mm.
h2 width of the concrete section, mm.
cx concrete cover, on x direction, mm.
cy concrete cover, on y direction, mm.
dx the distance between the two steel profiles HD 400x1299 (W14x16x873), on y - direction, mm.
dy the distance between the two steel profiles HD 400x1299 (W14x16x873), on x - direction, mm.
7/30/2019 Design Examples Mega Columns
31/74
30
dsx the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the
section neutral axis, on x - direction, mm.
dsy the distance from the local centroid of the steel profile HD 400x1299 (W14x16x873) to the
section neutral axis, on y direction, mm.
ds2x the distance from the local centroid of As1 plate to the section neutral axis, on x - direction, mm.
ds1y the distance from the local centroid of As2 plate to the section neutral axis, on y - direction, mm.
Solution:
A simplification of the composite section is made by replacing the reinforcement by equivalent steel plates, as
shown in Fig. I.X2-1. Horizontal plates include only reinforcement that belongs to the two main lines. One
horizontal plate, As1, replace 52 reinforcement rebars.
52=x
n
2 252T40 52 1256.64mm 65364mm= = =s1A ;
For 1003072mm (86mm mm) 2800mm2
= + =s1hbs1 = 23.338 mm;
Side plates includes besides the two lateral lines, the few additional rebars. The number of reinforcement which
corresponds to one lateral plate is 76.
30 30 3 2 5 2 76y
n = + + + =
2 276T40 76 1256.64mm 95532mms2A = = = ;
For 3072mm 2 86mm 2900mms2h = = bs2 = 32.933 mm;
The moment of inertia of the reinforcing bars about the elastic neutral axis of the composite section, Isr, is
determined for the two equivalent plates As1 and As2, and is calculated as follows:
( )3
10 423.338mm 2800mm
4.269 10 mm12 12
3
s1 s1
sr1y
b hI
= = =
;
( )3
6 42900mm 32.933mm
8.632 10 mm12 12
3
s2 s2
sr2y
h bI
= = =
( )210 4 6 4 4 2
11 4
2 2 2
2 4.269 10 mm 2 8.632 10 mm 2 9.55 10 mm 1450mm
4.87 10 mm
2
sry sr1y sr2y s2 s2xI I I A d
= + + +
= + +
=
where
Isr1y moment of inertia about y axis ofAs1 plate, mm4.
Isr2y moment of inertia about y axis ofAs2 plate, mm4.
Isry moment of inertia about y axis of equivalent plates, mm4.
hs1 height ofAs1 plate, mm.
bs1 width ofAs1 plate, mm.
hs2 height ofAs2 plate, mm.
bs2 width ofAs2 plate, mm.
7/30/2019 Design Examples Mega Columns
32/74
31
The moment of inertia values of the entire steel section about Y-Y axis is determined as:
( )22 4 2 11 4
HDy4 4 I 4 165000mm 1012mm 4 254400 10 mm 6.861 10 mm2
sy a sxI A d= + = + =
where
Isy moment of inertia about y axis of the steel profiles, mm.
The moment of inertia values for the concrete about both axes axis is determined as:
( )3
12 413072mm 3072mm
7.421 10 mm12 12
3
2
g
h hI
= = =
12 4 11 4 11 4 12 4- - 7.421 10 mm 4.87 10 mm 6.861 10 mm 6.428 10 mm
cy g sry syI I I I= = =
where
Icy moment of inertia about y axis of the concrete part , mm4.
Material and Detailing Limitations
Material limits are provided in AISC Specification Sections I1.1 (2) and I1.3 as follows:
(1) Concrete strength: 21MPa 70MPacf'
50MPacf' = o. k.
(2) Specified yield stress of structural steel: 525MPay
F
450MPay
F = o. k.
(3) Specified yield stress of structural steel: 525MPaysr
F
500MPaysrF = o. k.
Transverse reinforcement limitations are provided in AISC Specification Section I1.1 (3), I2.1a. (1), I2.1a. (2)
and ACI 318 as follows:
(1) Tie size and spacing limitations:
The AISC Specifications requires that either lateral ties or spirals be used for transverse reinforcement.
Where lateral ties are used, a minimum of either 10 mm (No. 3) bar placed at a maximum of 406 mm
(12 in.) on center, or a 13 mm (No. 4) bar or larger spaced at a maximum of 406 mm (16 in.) on center
shall be used.
14 mm lateral ties at 75 mmare provided. o. k.
Note that AISC Specification Section I1.1 (1) specifically excludes the composite column provision of
ACI 318 Section 10.13, so it is unnecessary to meet the tie reinforcement provisions of ACI 318
Section 10.13.8. when designing composite columns using AISC Specifications Chapter I.
If spirals are used, the requirements of ACI 318 Sections 7.10 and 10.9.3 should be met according to
the User Note at the end of AISC Specification I2.1a.
(2) Additional tie size limitation:
ACI 318 Section 7.10.5.1 requires that all nonprestressed bars shall be enclosed by lateral ties, at least
10 mm (No. 3) in size for longitudinal bars 32 mm (No. 10) or smaller, and at least 13 mm (No. 4) in
size for 36 mm (No. 11), 43 mm (No. 14), 57 mm (No. 18), and bundled longitudinal bars.
7/30/2019 Design Examples Mega Columns
33/74
32
14 mm lateral ties are provided for 40 mm longitudinal bars. o. k.(3) Maximum tie spacing should not exceed 0.5 times the least column dimension:
3072mm0.5 min 1536mm
3072mm
1
max
2
hs
h
= = =
=
75mm 1536mmmaxs s= = o. k.
(4) Concrete cover:
ACI 318 Section 7.7 contains concrete cover requirements. For concrete not exposed to weather or in
contact with ground, the required cover for column ties is 38 mm (1.5 in).
86mm 1T14 86mm 14mm 72mm 38mmcover= = = > o. k.
(5) Provide ties as required for lateral support of longitudinal bars:
AISC Design Examples 2011 Part1, page I-96 indicates the following:
AISC Specification Commentary Section I2.1a references Chapter 7 of ACI 318 for additional
transverse tie requirements. In accordance with ACI 318 Section 7.10.5.3 and Fig. R7.10.5,
ties are required to support longitudinal bars located farther than 6 in. clear on each side from a
laterally supported bar. For corner bars, support is typically provided by the main perimeter
ties. For intermediate bars, Fig. I.9-1illustrates one method for providing support through the
use of a diamond-shaped tie.
Longitudinal and structural steel reinforcements limits are provided in AISC Specification Section I1.1 (4), I2.1
and ACI 318 as follows:
(1) Structural steel minimum reinforcement ratio: / 0.01s g
A A
5 2
6 2
6.6 10 mm0.070mm
9.437 10 mm
=
o. k.
(2) Minimum longitudinal reinforcement ratio: / 0.004sr g
A A
5 2
6 2
3.216 10 mm0.034mm
9.437 10 mm
=
o. k.
(3) Maximum longitudinal reinforcement ratio: / 0.08sr g
A A
5 2
6 2
3.216 10 mm0.034mm
9.437 10 mm
=
o. k.
(4) Minimum number of longitudinal bars:
ACI 318 Section 10.9.2 requires a minimum of four longitudinal bars within rectangular or circular
members with ties and six bars for columns utilizing spiral ties. The intent for rectangular sections is to
provide a minimum of one bar in each corner, so irregular geometries with multiple corners require
additional longitudinal bars.
256 bars provided o. k.
(5) Clear spacing between longitudinal bars:
ACI 318 Section 7.6.3 requires a clear distance between bars of 1.5db or 38 mm (1.5in.).
7/30/2019 Design Examples Mega Columns
34/74
33
1.5 60mmmax 60mm
38mm
b
min
ds
= = =
100mm 40mm 60min
s s= = o. k.
(6) Clear spacing between longitudinal bars and the steel core:
AISC Specification Section I2.1e requires a minimum clear spacing between the steel core and
longitudinal reinforcement of 1.5 reinforcing bar diameters, but not less than 38 mm (1.5 in.).
1.5 60mmmax 60mm
38mm
b
min
ds
= = =
The distance from the steel core and the longitudinal bars is determined from Fig. I.X1-1, on x
direction as follows:
524mm 60mm 2 40mm 146mm2
min
bs s= = o. k.
The distance from the steel core and the longitudinal bars is determined from Fig. I.X2-1, on y
direction as follows:
586mm 60mm 2 40mm 100mm2
min
hs s= = o. k.
where
h height of HD 400x1299 (W14x16x873) steel profile, mm.
b width of HD 400x1299 (W14x16x873) steel profile, mm.
(7) Concrete cover for longitudinal reinforcement:
ACI 318 Section 7.7 provides concrete cover requirements for reinforcement. The cover requirements
for column ties and primary reinforcement are the same, and the tie cover was previously determined to
be acceptable, thus the longitudinal reinforcement cover is acceptable by inspection.
Interaction of Axial Force and Flexure
AISC Design Examples 2011 Part1, page I-104 indicates the following:
The interaction between axial forces and flexure in composite members is governed by AISC
Specification Section I5 which, for compact members permits the use of a strain compatibility method
or plastic stress distribution method, with the option to use the interaction equations of Section H1.1.
The strain compatibility method is a generalized approach that allows for the construction of an
interaction diagram based upon the same concepts used for reinforced concrete design. Application of
the strain compatibility method is required for irregular/nonsymmetrical sections.
Plastic stress distribution methods are discussed in AISC Specification Commentary Section I5 which
provides three acceptable procedures for filled members. Plastic stress distribution methods are
discussed in AISC Specification Commentary Section I5. The procedure involves the construction of a
piecewise-linear interaction curve using the plastic strength equations provided in Fig. I-1-1 located
within the front matter of the Chapter I Design Examples. The method is a reduction of the piecewise-
7/30/2019 Design Examples Mega Columns
35/74
34
linear interaction curve that allows for the use of less conservative interaction equations than those
presented in Chapter H.
Thereafter are provided approaches following two methods: a plastic stress distribution method and a finite
element analysis.
Method1 - Interaction Curves from the Plastic Stress Distribution Model
Step 1: Construct nominal strength interaction surface A, B, C, and D without length effects, using the equations
provided in Fig. I-1f for bending about the Y-Yaxis:
Point A (pure axial compression): the available compressive strength is calculated as illustrated in Design
Example I.9.
( )5 2 5 2 6 20.85
6.6 10 mm 450MPa 3.216 10 mm 500MPa 8.455 10 mm 0.85 50MPa
817207.653kN
A s y sr ysr c cP A F A F A f'
= + +
= + +
=
0kNmAM =
Point D (maximum nominal moment strength):
( )6 2
0.85
2
8.455 10 mm 0.85 50MPa
2
179679.054kN
c c
D
A f'P
=
= =
=
The applied moment, illustrated in Fig. I-1f, is resisted by the flexural strength of the composite section about its
Y-Y axis. The strength of the section in pure flexure is calculated using the equations of Fig. I-1f found in the
front matter of the Chapter I Design Examples for Point B. Note that the calculation of the flexural strength at
Point B first requires calculation of the flexural strength at Point D as follows:
( )2
7 323.338mm 2800mm
9.148 10 mm4 4
2
s1 s1
sr1y
b hZ
= = =
4 4 8 32 2 9.55 10 mm 1450mm 2.769 10 mmsr2y s2 s2x
Z A d= = = ;
7 3 8 3 8 39.148 10 mm 2.769 10 mm 3.684 10 mm
sry sr1y sr1yZ Z Z= + = + =
5 4 8 3
4 2 1.65 10 mm 1012mm 6.679 10 mmsy a syZ A d= = = ;
( )2
7 3 8 3 8 3
9 3
43072mm 3072mm
9.148 10 mm 2.769 10 mm 6.679 10 mm4
6.211 10 mm
2
1 2
cy r1y r2y sy
h hZ Z Z Z
=
=
=
where
Zsr1y full y-axis plastic modulus ofAs1 plate, mm3.
7/30/2019 Design Examples Mega Columns
36/74
35
Zsr2y full y-axis plastic modulus ofAs2 plate, mm3.
Zsy full y-axis plastic modulus of steel shape, mm3.
Zcy full y-axis plastic modulus of concrete shape, mm3.
The bending moment of a composite cross-section is taken about the axis of symmetry. Therefore, the maximum
bending moment is obtained by placing the plastic neutral axis at the axis of symmetry of the composite cross-
section. This conclusion can be obtained by examining the change in the bending moment of the composite
cross-section by making a small change in the position of the plastic neutral axis. The coefficient of in front
of the concrete part is a result on the assumption that concrete has no tensile strength and only the compressive
strength contributes to the bending moment capacity.
( ) ( )
( ) ( )8 3 7 3 8 3 9 3
5
10.85
21
6.679 10 mm 450MPa 9.148 10 mm 2.769 10 mm 500MPa 6.211 10 mm 0.85 50MPa2
6.168 10 kNm
'
Dy sy y sr1y sr2y ysr cy cM Z F Z Z F Z f
=
= + + +
= + + +
Point B (pure flexure):
0kNB
P =
The stress distribution type C from Fig. I1f provides the same moment resistance as B, since the moment from
the stress resultants cancel each other. However, the resulting resistance to axial force is of the same magnitude
from the pure concrete part 'c0.85 f . This can be seen from adding up the stress distribution in B and C, with
regard to the equilibrium of forces, by example the resulting axial force. This follows because the resistance to
axial force in B is zero. Subtracting the stress distributions of B from that of C it results the value of hny.
In order to determine the position of the neutral axis, on Y-Y direction, the HD 400x1299 steel profile has been
considered as a rectangle bar (h* x b) with an equivalent area, as shown in Fig. I.X2-2a.
165000mm346.639mm
476mm
aA
h*=b
= =;
where
b the width of the HD 400x1299 steel profile;
7/30/2019 Design Examples Mega Columns
37/74
36
Fig. I.X2-2a. Subtracting the components of the stress distribution combination at point B and C considering
normal force only, when the a.n. is between the profiles.
( ) ( )0.85 359358.109kN
0.85 2 2 0.85C B C c c
ny 2 c ny s1 yrs c
P P P A f'
= 2 h h f' h b F f'
= = =
+
( ) ( )
( ) ( )
20.85 2 2 0.85
359358.109kN
3072mm 0.85 50MPa 8 23.338mm 2 500MPa 0.85 50MPa
1.175m
C
ny
c s1 yrs c
Ph
2 h f' b F f'
=2
=
+
+
=
Check assumption 2ny sx
b
h d
:
1175mm 774mm2
ny sx
bh d= =
assumption not. k.
Assumption 2: the neutral axis is placed within the steel profiles2 2
sy nx sy
h hd
7/30/2019 Design Examples Mega Columns
38/74
37
Fig. I.X2-2b. Subtracting the components of the stress distribution combination at point B and C considering
normal force only, when the a.n. is within the profiles.
( ) ( ) ( )0.85 359358.109kN
0.85 2 0.85 2 2 0.85C B C c c
ny 1 c s y c ny s1 yrs c
P P P A f'
= 2 h h f' A F f' h b F f'
= = =
+ +
( )
( ) ( ) ( )
( )
( )
2 s1
4 0.852
0.85 4 0.85 2 0.85
476mm359358.109kN 4 1012mm 346.639mm 2 450MPa 0.85 50MPa
2
3072mm 0.85 50MPa 4 346.639mm 2 45
C sx y c
ny
c y c yrs c
bP d h* 2 F f'
h2 h f' h* 2 F f' b 2 F f'
=2
+
=
+ +
+
+ ( ) ( )0MPa 0.85 50MPa 2 23.338mm 2 500MPa 0.85 50MPa
856mm
+
=
Check assumption2 2
sy nx sy
h hd
7/30/2019 Design Examples Mega Columns
39/74
38
( )
( )7 3 7 3 9 3
1 0.852
1616779.059kNm 3.421 10 mm 500MPa 9.273 10 mm 450MPa 2.124 10 mm 0.85 50MPa
2
512804.327kNm
By Dy r1yn yrs syn y cyn cM M Z F Z F Z f'
=
=
=
wherecynZ - y-axis plastic modulus of concrete section within the zone 2hn,mm3.
synZ - y-axis plastic modulus of equivalent rectangle bar within the zone 2hn,mm
3.
sr1ynZ - y-axis plastic modulus ofAs1 plates within the zone 2hn,mm3.
Point C (intermediate point):
6 2
0.85
0.85 8.455 10 mm 50MPa
359358.109kN
C c cP A f'
=
= =
=
512804.327kNmCy By
M M= =
The available compressive and flexural strengths are determined as follows:
LFRD ASD
Design compressive strength:
0.75C =
where
X" C XP P
X = A,B,C or D
=
0.75 817207.65kN 612905.739kN
A" C AP P
=
= =
0.75 0kN 0kN
B" C BP P
=
= =
0.75 359358.109kN 269518.582kN
C" c C P P
=
= =
0.75 179679.054kN 134759.291kN
D" c DP P
=
= =
Allowable compressive strength:
C 2.00=
where
X
X"
C
PP
X = A,B,C or D
=
817207.65kN408603.826kN
2
AA"
c
PP
=
= =
0kN0kN
2
B
Bc
PP
=
= =
C
359358.109kN 179679.055kN2
C"c
PP
=
= =
D
179679.054kN89839.53kN
2
D"c
PP
=
= =
7/30/2019 Design Examples Mega Columns
40/74
39
Design flexural strength:
0.90B
=
where
X" B XM M
X = A,B,C or D
=
0.9 0kNm 0kNm
Ay" B AyM M
=
= =
0.9 512804kNm 461524kNm
By" B ByM M
=
= =
0.9 512804kNm 461524kNm
Cy" B CyM M
=
= =
0.9 616779.059kNm 555101.153kNm
Dy" B DyM M
=
= =
Allowable compressive strength:
b 1.67=
b
where
X
X"
MM
X = A,B,C or D
=
b
0kNm0kNm
1.67
Ay
Ay"
MM
=
= =
b
512804kNm307068kNm
1.67
By
By"
MM
=
= =
b
512804kNm307068kNm
1.67
Cy
Cy"
MM
=
= =
b
616779.059kNm369328.778kNm
1.67
Dy
Dy"
MM
=
= =
The design and allowable strength values are plotted in Fig. IX2-3.
Fig. I.X2-3. ASD and LFRD interaction surfaces.
7/30/2019 Design Examples Mega Columns
41/74
40
Method2 FEM Results
Table of results obtained with Simple method and Finite Element model.
Nominal LFRD ASD Nominal LFRD ASD FineLg
P [kN] 0.75 P [kN] P /2 [kN] My [kNm] 0.9 My [kNm] My/1.67 [kNm] My
Point B 0 0 0 512804 461524 307068 528385
Point D 179679 134759 89839 616780 555102 369329 622210
Point C 359358 269518 179679 512804 461524 307068 524608
Point A 817207 612905 408603 0 0 0 0
Fig. I.X2-4. Comparison between the Plastic Distribution Method and the FEM method.
Conclusion
Design values of M-N interaction diagram have been obtained on the basis of a simple method presented in
AISC Specification and for which explicit expressions have been developed for the case of composite sections
with several encased steel profiles; these expressions are presented in Figures I-1e and I-1f.
The results of the finite element study made with more refined models confirm the validity of the results
obtained by that the simple method in the case of composite sections with several encased steel profiles
(compare nominal and FinelG in Table above).
The simple method can be kept to evaluate design values of M-N interaction for that case.
7/30/2019 Design Examples Mega Columns
42/74
41
EXAMPLE I.X3 COMPOSITE COLUMN WITH 4 ENCASED STEEL PROFILES IN SHEAR
DIRECTION Y.
Given:
Determine if the composite member with 4 encased steel profiles illustrated in Figure I.X4-1 is adequate for the
axial forces, shears and moments given hereunder, that have been determined in accordance with the direct
analysis method of AISC 2010 Specification Chapter C for the control of ASCE(2010)ASCE/SEI 7-10 load
combinations:
Factored bending moment: Mu,X = 450000kNm
Factored axial (compression) force: Nu = 180000kN
Factored transverse shear Vu,Y in direction Y: Vu,Y= 20000 kN
The characteristics of the steel profile are:
h = 600 mm b= 476 mm tf = 140 mm tw = 100 mm
A =165000 mm2
Iy = 754600. 104
mm4
Iz = 254400.104
mm4
Solution:
Fig. I.X3-1. Definition of notations.
Available Shear Strength
According to AISC Specification Section I4.1, there are three acceptable options for determining the available
shear strength of an encased composite member:
7/30/2019 Design Examples Mega Columns
43/74
42
Option 1- Available shear strength of the steel section alone in accordance with AISC Specification Chapter G.
Option 2- Available shear strength of the reinforced concrete portion alone per ACI 318.
Option 3- Available shear strength of the steel section in addition to the reinforcing steel ignoring the
contribution of the concrete.
Option 1 clearly is a gross underestimation for the section with 4 encased steel profiles, because it would consist
in disregarding the contribution to shear resistance of a net areaAc of concrete equal toAc = 8,45 m2. Option 1 is
not developed.
Option 2 is envisaged hereunder.Its application however requires one adaptation for composite sections with
several encased steel profiles, in comparison to, for instance, the procedure presented in Design Example I.11.
The principle of the adaptation is explained hereunder. It requires separate calculation of shear strength of sub-
sections composing the complete section. This is presented in detail.
Option 3 will not be used because it would be unsafe for composite sections with several encased steel profiles.
This is explained below.
Principle of the adaptation of Option 2 to sections with several encased steel profiles.
The problem to solve in sections with several encased profiles is that concrete and steel components
contributing to shear resistance are not working in parallel, like in the case of one central steel profile encased in
concrete: they are, for some part, working in series or chain. This is easier to understand if one subdivides the
column section into 5 smaller sections, each providing resistance to shear. They are respectively the sections of
width bc3 (2 sections), bs (2 sections) and bc4 (1 section), all with height hz.They are named section bc3, section bc4 and section bs in the following.
The applied shear force Vu,Y will distribute itselfinto Vu,bc3 , Vu,bc4 and Vu,bs between sections bc3, bc4 and bs,
proportionally to the stiffness of those sections.
Then each section should provide strength greater than the applied shear force in that section.
Sections bc3 and bc4 are regular reinforced concrete sections and can be treated as such.
But section bs is a composite steel-concrete section having 2 reinforced concrete flanges, 2 inner steel profiles
(the HD sections) and 1 reinforced concrete web. Section bs is a chain of components in concrete and steel; its
strength should be calculated on the basis of the weakest link, which is concrete. This is why the check for
transverse shear is made on one section bs homogenized in concrete. All components of that section are taken
into account. This is valid because the steel profile has more strength than its equivalent concrete section, as
shown by the following comparison of pure shear resistance:
- for the steel profile: Vn = 0.6FyAwCv (Spec. Eq G2-1)For webs of rolled I-shaped members with
7/30/2019 Design Examples Mega Columns
44/74
43
h/tw 2,24y
E
F=> v = 1.00 and Cv= 1.0 (Spec. Eq G2-2)
The HD section height and web thickness are: h = 600 mm tw=100 mm
h/tw= 6 2,24y
E
F
= 47,2
Aw = 100 x (600- 2 x 140) =32000 mm2
Vn HD = 0.6FyAwCv = 0,60x 450 x 32000 x 1 = 8640 kN
vVn = 8640 > Vu,t,S2= 2134 kN
where Vu,t,S2 is the transverse shear in the steel profile as calculated in the section Resistance to
transverse shear of the HD profile.
- For a concrete section with same height and width of concrete equivalent to the steel profile, the shearstrength in case of pure shear applied to a section without transverse reinforcement is:
Vc = 2fc bw d ACI318-08(11-3)
=1,0 for normal weight concreteIn international units (N, mm),ACI318-08(11-3) expression becomes:
Vc =0,1693 fc bw d =1,1971 bw d for fc=50MPa
A similar expression is defined, which takes into account longitudinal reinforcement with an upper
bound value:
Vc = 3,5fc bw d ACI318-08(11-5)
In international units (N, mm), it becomes:
Vc = 0,2963 fc bw d = 2,095 bw d for fc=50MPa
bw= 100 x 200000/38004 =526 mm
d = h1 = 600 mm
Vc = 2,095 bw d= 661 kN
Vc =0,75 x 661,1 = 496 kN
It results: vVn,HD = 0.6FyAwCv = 8640 kN > Vc= 496 kN
And it can be concluded that it is justified to make concrete only checks for shear resistance: the concrete part
of the section bs is weaker and would fail first. The extra strength of the steel profiles above concrete strength
has no use, as it would only intervene after crushing the concrete web.
[Note: the expression found in the provisory version of Eurocode 2 or ENV1992 indicated a value for the shear
resistance VRd very similar to Vc = 2,095 bw d:
( )1 1,2 40Rd Rd w lV b dk = + =0,48 x(1,2 +40 x 0,104) bwd= 2,57 bwd with l = 0,104 for the section defined
in this example].
Why Option 3 cannot be applied to sections with several encased steel profiles.
In option 3, the available shear strength would be found as the addition of the available shear strength of the
steel sections in addition to the available shear strength of the reinforcing steel, ignoring the contribution of the
concrete. In fact, this way to present things does not express clearly what is meant. The idea is that, due to
7/30/2019 Design Examples Mega Columns
45/74
44
cracking, the contribution to shear resistance of concrete without transverse reinforcement Vc is equal to 0. In
such case, the shear resistance of reinforced concrete in shear can exist, due to transverse reinforcement and
equilibrium between inclined compression struts of concrete and tension in steel ties, the stirrups. In such
case, the available shear strength indicated in ACI318-08 is Vs , meaning that the total shear strength is only Vs
instead of being (Vc+ Vs).
But Vsis limited to an upper bound value corresponding to crushing of concrete compression struts in the strut
and ties equilibrium recalled above. That l imit is:
Vs = 8fc bw d ACI318-08(11.4.7.9)
That expression expressed in international units, with the data of the section under consideration, becomes:
Vs = 0,676fc bw d= 4,78 bw d forfc = 50MPa
[Note: it is remarkable that in option 3, the available shear strength is said to be the addition of the available
shear strength of the steel section to the available shear strength of the reinforcing steel, but the available shear
strength of the reinforcing steel is in fact a concrete strength].
However, in a section with several steel profiles, the applied shear force Vu,Y will distribute itselfinto Vu,bc3 ,
Vu,bc4 and Vu,bs between sections bc3, bc4 and bs, proportionally to the stiffness of those sections. Section bs
being made of components working in series or chain, the strength of the chain should be calculated on the
basis of its weakest link, which is concrete. So Option 3 has to be applied in the same way as Option 2 and
adding the shear strength of the steel profiles to a shear strength of the reinforcement would lead to an unsafe
design.
Distribution of transverse shear in the composite section.
The symbols are defined at Figure I.X3-2.
The width bc3, bs and bc4 are:
bc3 = 286mmbs = 476 mm
bc4 = 3072 2 x (286+476) = 1548 mm
7/30/2019 Design Examples Mega Columns
46/74
45
Fig. I.X3-2. Definition of sections bc3, bc4, and bs.
Fig. I.X3-3. Position of the reinforcement and the HD profiles.
The applied shear force Vu,Y is distributed between sections bc3, bc4 and bs proportionally to their stiffness:
Vu,bc3
= Vu,Y
x (EIeff
)bc3
/EIeff
Vu,bc4 = Vu,Y x (EIeff)bc4/EIeff
Vu,bs = Vu,Y x (EIeff)bs/EIeff
The effective bending stiffnessEIeffof the column is:
EIeff= Es Is + 0.5EsrIsr+ C1Ec Ic (Spec. Eq.I2-6)
C1= 0.1+ 2 [(As/(Ac+As)] 0,3 (Spec. Eq.I2-7)
In the envisaged section, there are 4 steel profiles, each with a sectionA.
7/30/2019 Design Examples Mega Columns
47/74
46
For a HD400x1299:A = 165000 mm2
Total section of 4 profiles: As = 4 A = 660000
mm2
There are 256 diameter 40mm reinforcing bars.
Asr = 256 x 1257 = 321792 mm2
Ac =Ag As Asr
Ac=3072 x 3072 660000 321792 = 8455392
mm2
C1 = 0,1 + 2[(660000/(8455392 + 660000)] =
0,245 0,3
Fig. I.X3-4. Definition of plates equivalent to bars.
The total effective bending stiffnessEIeffaround the X axis is the sum of individualEIeffestablished for sections
bc3, bs and bc4 respectively.
Section bc3: EIeff= 0.5EsrIsr+ C1EcIc (Spec. Eq.I2-6)
To calculateIsr, reinforcing bars are replaced in the calculations by 2 equivalent steel side plates. Figure I.X4-4.
Each plate has the same total areaAs,r,side as the 2 layers of side bars in lines plus 2x2 bars in the top and bottom
lines plus 2x4 inside bars.The height hp of the plates is the distance between the extreme bars:
hp = 3072 2 x 86 = 2900mm
On each side:
- the number of bars is: 30 +30 + 2 x (2+4) = 72- the area of those bars and of each equivalent plate is:As,r,side = 72 x 1257= 90504 mm2- the thickness of the equivalent plate is: tp=As,r,side /hp = 90504 / 2900 = 31,20 mm
7/30/2019 Design Examples Mega Columns
48/74
7/30/2019 Design Examples Mega Columns
49/74
48
Icg = bs x hy3/12 = 476 x 3072
3/12=1,15.10
12
Ic = Icg- Isr-Ics = 1,15.1012
- 3,1292.1011
- 3,94.1010
= 7.98.1011
EcIc = 38007 x 7.98.1011
= 3,03.1016
N x mm
(EIeff)bs=6,258.1016
+0,5 x 7,88.1015
+ 0,245 x 3,03.1016
= 7,39.1016
N x mm
EIeff=2 (EIeff)bc3 + (EIeff)bc4 +2 (EIeff)bs =2 x1,22.1016 + 4,91.1016 +2 x7,39.1016EIeff=2,21.10
17N x mm
The factored shear Vu,Y= 20000 kN for the complete section is distributed in the 5 sections (2 bc3, 2 bs, 1 bc4)
contributing to the shear strength of the complete section:
Vu,bc3= Vu,Y x (EIeff)bc3/EIeff= 20000 x 1,22.1016/2,21.10
17= 1104 kN
Vu,bs = Vu,Y x (EIeff)bs/EIeff = 20000 x 7,39.1016/2,21.10
17= 6688 kN
Vu,bc4= Vu,Y x (EIeff)bc4/EIeff= 20000 x 4,91.1016/2,21.10
17= 4430 kN
Section bs is a composite steel-concrete section having 2 reinforced concrete flanges, 2 steel flanges (the HD
sections) and 1 reinforced concrete web. To establish longitudinal shear in section bs, it is convenient to
transform the composite section into a single material section or homogenized section. The single material can
be either steel or concrete.
Choosing concrete, the moment of inertia of the homogenized concrete section Ic* is such that the stiffnessEc
Ic* of the homogenized section is equal to the stiffness (EIeff)bs :
Ic*= (EIeff)bs/Ec = 7,39.1016/38007 = 1,94.10
12mm
4
Fig. I.X3 - 5. Homogenized equivalent concrete section bs.
7/30/2019 Design Examples Mega Columns
50/74
49
In a homogenized section in concrete (Figure I.X4.5.), the width of concrete equivalent to the width of steel
flanges is bs*:
bs*=bs xEs/Ec =476 x 200000/38007= 2505 mm
The width of concrete equivalent to the width of steel web is tw*:
tw*=twxEs/Ec =100 x 200000/38007= 52,6 mm
The homogenized concrete section is presented at Figure I.X3-5.
Calculation of shear in section bs.
The resultant longitudinal shear force on sections like CC1 and CC2 at Figure I.X3-5 is:
Vu,l = (Vu,bs x S) /Is*
Sis the section modulus corresponding to the area limited by a sections CC1 and CC2.
Longitudinal shear is calculated at the interface between sections C1 and C2 and at the interface between
sections C2 and C, because these steel concrete interfaces are the surfaces where resistance to longitudinal shear
should be checked.
Calculation of longitudinal shear force applied at section CC1.
S1 is the section modulus for the section C1 ranging from edge to outer HD flange:
For the steel equivalent to concrete, width is bs*.
Height h1 is:
h1= 1536 950 600/2 =286 mm
The area is:Area1= bs x h1= 476 x 286 = 136136 mm
2
Distance to neutral axis: 950+300+286/2 = 1393 mm
Sc1 =136136 x 1393 = 189,6.106
mm3
The reinforcing bars have been replaced in the calculations by 1 equivalent steel plate (see above) of areaAs,r,bs :
As,r,bs = 8x1257= 10056 mm2
The equivalent area in concrete is: 10056 x 200000/38004 =52920 mm2
The distance between the center of that plate and the axis of symmetry is:
py = Y/2 = 1400 mm
Ssr = 52920 x 1400 = 74,1.106
S1= Sc1 + Ssr= 189,6.106
+ 74,1.106
= 263,7.106
mm3
The resultant longitudinal shear force on section CC1 is:
Vu,l,CC1 = (Vu,bs x S1) /Ic* = (6688.103x 263,7.10
6)/ 2,05.10
12= 860 N/mm
On 1 m length of column: Vu,l,CC1 = 860 kN/m
Calculation of longitudinal shear force applied at section CC2.
7/30/2019 Design Examples Mega Columns
51/74
50
S2 is the section modulus for the sections C1 plus C2 (the HD profile).
A= 165000 mm2
The equivalent area in concrete for the HD profile is: 165000 x 200000/38004 =868329 mm2
Distance of HD center to neutral axis: 950 mm
SHD= 868329 x 950 = 824,9.106mm
3
The concrete between the flanges is not taken into account as its contribution would require specific stirrups and
connectors welded on or going through the web of the steel profile, as stated in Eurocode 4 cl.6.3.3(2).
S2= Sc1 + Ssr+ SHD = 189,6.106
+ 74,1.106
+ 824,9.106
= 1088,6.106
mm3
Vu,l,CC2 = (Vu,bs x S2) /Ic* = (6688.103x 1088,6.10
6)/ 2,05.10
12= 3551 N/mm
On 1 m length of column: Vu,l,CC2 = 3551 kN/m
Resistance to longitudinal shear by headed studs.
The available shear strength of an individual steel headed stud anchor is determined in accordance with the
composite component provisions of AISC Specification Section I8.3 as directed by Section I6.3b.
Qnv =FuAsa (Spec. Eq. I8-3)
Asa = (19)2/4 = 283 mm
2per steel headed stud anchor diameter 19mm
Fu = 450 MPa
v = 0,65
v Qnv = 0,65 x 450 x 283 = 82777 kN = 82,8 kN
In Section CC1, the required number of anchors on the outer flange of the HD profile is:
nanchors= 860/82,8 = 10,3/m
Anchors are placed in pairs on the flange at 120mm longitudinal (vertical) spacing, meaning:8,33 x 2 = 16,6 anchors/m.
The 120mm longitudinal (vertical) spacing is justified
Recommended