View
236
Download
1
Category
Preview:
Citation preview
Compact centrifugal moduleswith AC, EC and DC motors
version 06/2010
The engineer’s choice
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 1
2
Compact centrifugal modules
Centrifugal fans with backward curved blades need additional components so they can be placed inside
the final unit without putting their proper function at risk. In the past, the majority of such components
used to be designed and built by the unit manufacturers themselves.
With the new compact centrifugal modules, this extra expenditure is no longer needed, as they come with
a square mounting plate with integrated inlet nozzle and motor suspension.
Mounting plate, inlet nozzle and motor suspension are made of robust and durable plastic, with the
additional benefit of not having to go for compromises in terms of aero-acoustic design.
The centrifugal modules are available with impellers in diameters ranging from 190 to 225 mm and with
either AC, EC or DC motors. They are extremely compact and simple to install – adjusting the impeller to
the nozzle at great expense is no longer needed. Optionally, a guard grille on the suction side may be
plugged on.
Take advantage of what a completely pre-installed functional unit has to offer:
- Compact design
- Optimised, certified and guaranteed functional unit
- Plug-and-Play characteristics
- AC, EC and DC versions with dimensions allowing for simple interchange
- Optional guard grille
- Simple logistics
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 2
3
EC compact centrifugal modules 12
size 190, 220, 225
AC compact centrifugal modules 6
size 190, 220, 225
Table of content
Accessories 24
DC compact centrifugal modules 18
size 190, 220, 225
Electrical connections 28
Technical parameters & scope 32
GreenTech: The Green Company 4
ebm-papst representatives & subsidiaries 36
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 3
Sustainability is at the Centre of OurThoughts and Actions. Out of Conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 4
5
GreenTech is acknowledged and certified.
Every step in our chain of production meets the stringent standards of
environmental specialists and the public. The 2008 Environmental Prize
of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
Award 2009 of the dena – to give just a few examples – testify to this.
The environmental advantage gained in the performance of the products
developed from our GreenTech philosophy can also be measured in the
fulfilment of the most stringent energy and environmental standards.
In many instances, our products are already well below the thresholds
energy legislation will impose a few years from now – several times over.
Our customers profit from this every day.
The heart of GreenTech is ebm-papst EC technology. The EC technology
at the core of our most efficient motors and fans allows efficiency of up
to 90%, saves energy at a very high level, significantly extends service
life and makes our products maintenance-free. These values pay off not
only for the environment, but every cent also pays off for the user! All
ebm-papst products – even those for which EC technology does not (yet)
make sense from an application viewpoint – feature the greatest possi-
ble connection of economy and ecology.
GreenTech is pro-active development.
Even in the design phase, the materials and processes we use are optimi-
sed for the greatest possible eco-friendliness, energy balance and –
wherever possible – recyclability.We continually improve the material
and performance of our products, as well as the flow and noise charac-
teristics. At the same time, we significantly reduce energy consumption.
Close cooperation with universities and scientific institutes and the pro-
fessorship we endow in the area of power engineering and regenerative
energies allows us to profit from the latest research findings in these
fields – and at the same time ensure highly qualified young academics.
GreenTech is ecofriendly production.
GreenTech also stands for maximum energy efficiency in our production
processes. There, the intelligent use of industrial waste heat and ground-
water cooling, photovoltaics and, of course, our own cooling and venti -
lation technology are of the utmost importance. Our most modern plant,
for instance, consumes 91% less energy than currently specified and
required. In this way, our products contribute to protecting the environ-
ment, from their origin to their recyclable packaging.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 5
6
AC centrifugal modulebackward curved, Ø 190
A
D
C
B
100 200 300 400 500 600
0 100 [CFM]50 150 350300200 250
[Pa]
40
80
120
160
200
240
280
320
360
400
440
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
8
[m3/h]
60 Hz50 Hz
1 111
2
3
3
22
3
44
4
4
2
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
Motor
M2E 068-BF
M2E 068-BF
subject to alterations
VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 28
A1)
A1)
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6, fibreglass-reinforcedRotor: Coated in black
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "B"– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
Nominal data
Type
Curve
Nominalvoltage
Frequency
Airflow
Speed/rpm
Powerinput
Currentdraw
Capacitor
Soundlevel
Perm.amb.temp.
Electr.connection
K2E 190(1)
K2E 190(2)
(1)external capacitor required;
(2)capacitor included
1~ 115 50 550 2400 50 0,45 6,0 /250 68 -25..+601~ 115 60 590 2600 62 0,55 6,0 /250 69 -25..+601~ 230 50 560 2500 57 0,26 2,0 /400 68 -25..+501~ 230 60 610 2700 74 0,33 2,0 /400 70 -25..+55
A
B
C
D
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
2400
2320
2270
2415
2600
2440
2360
2610
2500
2415
2375
2515
2700
2565
2505
2720
50
52
54
49
62
65
66
61
57
59
60
57
74
77
78
74
0,45
0,46
0,47
0,43
0,55
0,57
0,57
0,53
0,26
0,26
0,26
0,25
0,33
0,34
0,35
0,33
68
64
62
66
69
65
62
67
68
67
62
67
70
69
64
69
1
2
3
4
D
D
D
D
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 6
7
K2E 190-AO50 -02
kg
1,6
K2E 190-AO26 -01 1,6
0.2±Ø5
225+1.0
45˚
± 0.5Ø266
Ø266 0.5±
± 0.5
Ø244
204 0.5±
4321
6±0.3
1.0±79
X
View XMounting dimensions
– Motor protection: TOP wired internally– Connection leads: Plug system, Cable design on request– Protection class: I– Product conforming to standard: EN 60335-1, CE– Approvals: CCC, GOST
Centrifugal module
Coded plug systemAMP Universal-Mate-N-LokConnector shell: AMP 350 780-14 x Pin connector: AMP 926 886-1Mating connector(not part of delivery):Connector shell: AMP 350 779-44 x female terminal: AMP 926 884-1
115V:1 = Protective earth2 = N3 = L + capacitor4 = Capacitor
230V:1 = Protective earth2 = N3 = L4 = Not assigned (capacitor)
Massofcentrifugal
modulewith
support
basket
Connection leadsS. 26 f.
Electr. connectionS. 28
CapacitorS. 25
Guard grilleS. 24
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 7
8
AC centrifugal modulebackward curved, Ø 220
AC
D
B
200 400 600 800 1000
0 100 [CFM]200 600500300 400
[Pa]
100
200
300
400
500
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
82,
0
[m3/h]
60 Hz50 Hz
1 1
22
2
4
44
3
3
1
3
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
Motor
M2E 068-CF
M2E 068-CF
subject to alterations
VAC Hz m3/h rpm W A µF/VDB dB(A) °C p.28
A1)
A1)
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6, fibreglass-reinforcedRotor: Coated in black
– Number of blades: 11– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "F"– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
Nominal data
Type
Curve
Nominalvoltage
Frequency
Airflow
Speed/rpm
Powerinput
Currentdraw
Capacitor
Soundlevel
Perm.amb.temp.
Electr.connection
K2E 220(1)
K2E 220(2)
(1)external capacitor required;
(2)capacitor included
1~ 115 50 990 2650 90 0,80 10,0 /250 74 -25..+401~ 115 60 1120 3050 120 1,05 10,0 /250 76 -25..+551~ 230 50 990 2700 85 0,38 2,5 /400 74 -25..+551~ 230 60 1110 3050 115 0,51 2,5 /400 76 -25..+50
A
B
C
D
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
2650
2530
2460
2540
3050
2720
2555
2740
2700
2515
2440
2515
3050
2665
2490
2670
90
109
117
109
120
146
155
144
85
104
111
102
115
137
145
135
0,80
0,98
1,04
0,98
1,05
1,26
1,34
1,24
0,38
0,46
0,49
0,45
0,51
0,59
0,63
0,59
74
70
67
70
76
71
68
71
74
70
67
70
76
71
68
71
1
2
3
4
D
D
D
D
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 8
9
K2E 220-BB08 -02
kg
2,5
K2E 220-BB06 -01 2,5
0.2±
0.5±
Ø5
270
45˚
± 0.5Ø305
Ø305 0.5±
± 0.5
Ø294,5
247,5 0.5±
4321
7±0.3
1.0±92
X
View XMounting dimensions
– Motor protection: TOP wired internally– Connection leads: Plug system, Cable design on request– Protection class: I– Product conforming to standard: EN 60335-1, CE– Approvals: CCC, GOST
Centrifugal module
Coded plug systemAMP Universal-Mate-N-LokConnector shell: AMP 350 780-14 x Pin connector: AMP 926 886-1Mating connector(not part of delivery):Connector shell: AMP 350 779-44 x female terminal: AMP 926 884-1
115V:1 = Protective earth2 = N3 = L + capacitor4 = Capacitor
230V:1 = Protective earth2 = N3 = L4 = Not assigned (capacitor)
Massofcentrifugal
modulewith
support
basket
Connection leadsS. 26 f.
Electr. connectionS. 28
CapacitorS. 25
Guard grilleS. 24
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 9
10
AC centrifugal modulebackward curved, Ø 225
AC
D
B
200 400 600 800 1000 1200
0 100 [CFM]200 500300 400
[Pa]
100
200
300
400
500
600
700
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
82,
02,
22,
42,
6
[m3/h]
60 Hz50 Hz
1 11
22
2
4
4
4
33
3
700 800600
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
Motor
M2E 068-DF
M2E 068-DF
subject to alterations
VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 28
A1)
A1)
– Material: Back of housing: Die-cast aluminiumFront of housing (suction side): PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6, fibreglass-reinforcedRotor: Coated in black
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "F"– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
Nominal data
Type
Curve
Nominalvoltage
Frequency
Airflow
Speed/rpm
Powerinput
Currentdraw
Capacitor
Soundlevel
Perm.amb.temp.
Electr.connection
K2E 225 (1)
K2E 225 (2)
(1)external capacitor required;
(2)capacitor included
1~ 115 50 1260 2650 140 1,25 16,0 /250 75 -25..+451~ 115 60 1430 3000 195 1,72 16,0 /250 78 -25..+551~ 230 50 1260 2650 135 0,60 4,0 /450 75 -25..+551~ 230 60 1400 2950 200 0,90 4,0 /450 77 -25..+50
A
B
C
D
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
2650
2620
2565
2650
3000
2885
2755
2925
2650
2600
2545
2620
2950
2790
2660
2825
140
154
164
148
195
214
226
208
135
147
157
143
200
212
220
208
1,25
1,37
1,46
1,33
1,72
1,86
1,97
1,81
0,60
0,64
0,68
0,62
0,90
0,93
0,96
0,91
75
74
70
73
78
74
71
76
75
74
70
73
77
74
71
75
1
2
3
4
D
D
D
D
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 10
11
K2E 225-AD40 -02
kg
3,1
K2E 225-AD92 -01 3,1
0.2±
0.5±
Ø5
270
45˚
± 0.5Ø305
Ø305 0.5±
± 0.5
Ø294,5
247,5 0.5±
4321
7±0.3
1.0±118
X
View XMounting dimensions
– Motor protection: TOP wired internally– Connection leads: Plug system, Cable design on request– Protection class: I– Product conforming to standard: EN 60335-1, CE– Approvals: CCC, GOST
Centrifugal module
Coded plug systemAMP Universal-Mate-N-LokConnector shell: AMP 350 780-14 x Pin connector: AMP 926 886-1Mating connector(not part of delivery):Connector shell: AMP 350 779-44 x female terminal: AMP 926 884-1
115V:1 = Protective earth2 = N3 = L + capacitor4 = Capacitor
230V:1 = Protective earth2 = N3 = L4 = Not assigned (capacitor)
Massofcentrifugal
modulewith
support
basket
Connection leadsS. 26 f.
Electr. connectionS. 28
CapacitorS. 25
Guard grilleS. 24
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 11
12
EC centrifugal modulebackward curved, Ø 190
200
[CFM]
[Pa]
100
0,5
1,0
1,5
2,0
[inH 2O
]2,
5
[m3/h]400 600
200
300
400
500
600
0 200 300 400100
A
B
1 1
2
2
4
4
3
3
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K3G 190
Motor
K3G 190
M3G 055-CF
M3G 055-CF
VAC Hz rpm W A °C p. 29
H1)
H1)
Nominal data
Type
Curve
Nominalvoltage
Frequency
Speed/rpm
(1)
Max.pow
erinput(1)
Max.current
draw
(1)
Perm.amb.temp.
Electr.connection
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6, fibreglass-reinforcedRotor: GalvanisedElectronics enclosure: Die-cast aluminium
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "B"– Mounting position: Any– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
1~ 115 50/60 3150 85 1,20 -25..+60A
1~ 230 50/60 3395 104 0,75 -25..+60B
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
3265
3160
3150
3265
3515
3375
3395
3485
76
85
85
78
91
103
104
94
1,09
1,20
1,20
1,11
0,68
0,75
0,75
0,71
74
71
69
73
76
73
71
75
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 12
K3G 190-CB15 -02
kg
1,7
K3G 190-CB23 -01 1,7
13
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Locked-rotor protection• Output 10 VDC max. 1,1 mA
– EMC: Interference emission acc. to EN 61000-6-3Interference immunity acc. to EN 61000-6-2Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1– Cable exit: Variable– Protection class: I– Product conforming to standards: EN 60335-1, CE– Approvals: VDE, UL, CSA, CCC, GOST are applied for
45˚
±0.5Ø266
±0.5
Ø244
204 0.5±
68545
0+20
±0.36
±1.0101
0.5±
0.2±Ø5
Ø266
225+1.0
Guard grillep. 24
Electr. connectionp. 29
Centrifugal module
Massofcentrifugal
modulewith
support
basket
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 13
14
EC centrifugal modulebackward curved, Ø 220
A
B
200 400 600 800 1000
0 100 [CFM]200 600500300 400
[Pa]
100
200
300
400
500
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
82,
0
[m3/h]
1 1
2
2
4
4
3
3
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K3G 220
Motor
K3G 220
M3G 055-CF
M3G 055-CF
VAC Hz rpm W A °C p. 29
H1)
H1)
Nominal data
Type
Curve
Nominalvoltage
Frequency
Speed/rpm
(1)
Max.pow
erinput(1)
Max.current
draw
(1)
Perm.amb.temp.
Electr.connection
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6, fibreglass-reinforcedRotor: GalvanisedElectronics enclosure: Die-cast aluminium
– Number of blades: 11– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "B"– Mounting position: Any– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
1~ 115 50/60 2340 75 1,10 -25..+60A
1~ 230 50/60 2670 105 0,78 -25..+60B
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
2600
2435
2340
2420
2990
2780
2670
2720
56
70
75
68
76
97
105
101
0,82
1,03
1,10
0,99
0,56
0,71
0,78
0,75
72
68
65
69
76
72
70
73
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 14
K3G 220-CD21 -02
kg
1,8
K3G 220-CD17 -01 1,8
15
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Locked-rotor protection• Output 10 VDC max. 1,1 mA
– EMC: Interference emission acc. to EN 61000-6-3Interference immunity acc. to EN 61000-6-2Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1– Cable exit: Variable– Protection class: I– Product conforming to standards: EN 60335-1, CE– Approvals: VDE, UL, CSA, CCC, GOST are applied for
45˚
±0.5Ø305
±0.5
Ø294,5
247,5 0.5±
68545
0+20
±0.37
±1.0109
0.5±
0.2±
0.5±
Ø5
270
Ø305
Guard grillep. 24
Electr. connectionp. 29
Centrifugal module
Massofcentrifugal
modulewith
support
basket
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 15
16
EC centrifugal modulebackward curved, Ø 225
A
B
200 400 600 800 1000
0 100 [CFM]200 600500300 400
[Pa]
100
200
300
400
500
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
82,
0
[m3/h]
1 1
2 2
4
33
4
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K3G 225
Motor
K3G 225
M3G 055-CF
M3G 055-CF
VAC Hz rpm W A °C p. 29
H1)
H1)
Nominal data
Type
Curve
Nominalvoltage
Frequency
Speed/rpm
(1)
Max.pow
erinput(1)
Max.current
draw
(1)
Perm.amb.temp.
Electr.connection
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6.6, fibreglass-reinforcedRotor: GalvanisedElectronics enclosure: Die-cast aluminium
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 44– Insulation class: "B"– Mounting position: Any– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
1~ 115 50/60 2185 85 1,23 -25..+60A
1~ 230 50/60 2240 91 0,71 -25..+60B
2395
2235
2185
2265
2455
2310
2240
2320
70
82
85
79
75
86
91
85
1,01
1,19
1,23
1,15
0,57
0,66
0,71
0,67
71
65
62
68
72
67
64
68
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 16
kg
2,1
2,1
17
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Locked-rotor protection• Output 10 VDC max. 1,1 mA
– EMC: Interference emission acc. to EN 61000-6-3Interference immunity acc. to EN 61000-6-2Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1– Cable exit: Variable– Protection class: I– Product conforming to standards: EN 60335-1, CE– Approvals: VDE, UL, CSA, CCC, GOST are applied for
45˚
±0.5Ø305
±0.5
Ø294,5
247,5 0.5±
68545
0+20
±0.37
±1.0135
0.5±
0.2±
0.5±
Ø5
270
Ø305
K3G 225-CE21 -02
K3G 225-CE11 -01
Guard grillep. 24
Electr. connectionp. 29
Centrifugal module
Massofcentrifugal
modulewith
support
basket
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 17
18
DC centrifugal modulebackward curved, Ø 190
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
BA
C
D
100 200 300 400 500 600 700 800 900
0 100 [CFM]200 500 600300 400
[Pa]
100
200
300
400
500
600
700
800
900
0,4
0,8
1,2
[inH 2O
]1,
62,
02,
42,
83,
23,
6
[m3/h]
111
3
3
3
2
2
2
4
4
4
1000
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
1
2
3
4
D
D
D
D
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6.6, fibreglass-reinforcedRotor: Galvanised
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 20 or IP 66– Insulation class: "E"– Mounting position: Any– Condensate discharges: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
RG 190 54.14; 3ph.
RG 190 54.14; 3ph.
subject to alterations
VDC VDC m3/h rpm W A dB(A) °C
Curve
Nominalvoltage
Voltage
Range
Airflow
Soundlevel
Perm.amb.temp.
Hours
ServiceLifeL 10(40°C)
ebm-papstStandard
RG 190 54.20; 3ph.
RG 190 54.20; 3ph.
Speed/rpm
Powerinput
Currentdraw
p. 31
G2)
G2)
Electr.connection
G2)
G2)
ServiceLifeL 10(Tmax)
ebm-papstStandard
Lifeexpectancy
L 10∆
(40°C)
Hours
55000 / 35000
55000 / 35000
52500 / 30500
42500 / 22500
110000
110000
105000
80000
RG 190 54.14; 3ph. G2)55000 / 35000 110000
RG 190 54.14; 3ph. G2)55000 / 35000 110000
24 16-30 700 3000 60 2,50 74 -20..+60
48 36-57 700 3000 60 1,25 73 -20..+60
24 16-36 890 3900 115 4,80 79 -20..+65
48 36-72 1080 4600 192 4,00 81 -20..+65
A
B
C
D
48 36-57 700 3000 60 1,25 73 -20..+60B
24 16-30 700 3000 60 2,50 74 -20..+55A
3000
3040
2970
3015
3000
2995
2990
3045
3900
3955
3895
3960
4600
4610
4540
4645
60
78
84
81
60
69
78
75
115
138
155
146
192
219
240
227
2,50
3,31
3,59
3,44
1,25
1,47
1,66
1,59
4,80
5,79
6,51
6,10
4,00
4,61
5,05
4,77
74
70
68
70
73
70
67
70
79
77
74
77
81
81
77
80
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 18
19Guard grillep. 24
Electr. connectionsp. 31
45˚
± 0.5Ø266Ø266 0.5±
± 0.5
Ø244
204 0.5±
6 ± 0.30.2±Ø5
1.0±79225+1.0
Connection via single stranded wires AWG 20; TR64;Tach signal and control input AWG22;Cable length 350 mm as of housing
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection
– Cable exit: Variable– Protection class: III; I– Product conforming to standard: EN 60950-1, UL 507, C22.2 No.113– Approvals: VDE, UL, CSA are applied for
DCBA
RG190-45/14/2TDMLO
kg IP
1,21 20
RG190-45/18/2TDMLO 1,21 20
RG190-45/14/2TDMO 1,21 20
RG190-45/18/2TDO 1,21 20
Massofcentrifugal
modulewith
support
basket
Centrifugal module
Type
ofprotection
RG190-45/18/2TDMLOU 1,21 66
RG190-45/14/2TDMLOU 1,21 66
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 19
20
DC centrifugal modulebackward curved, Ø 220
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
A
200 400 600 800 1000 1200
0 100 [CFM]200 500300 400
[Pa]
100
200
300
400
500
600
700
0,2
0,4
0,6
[inH 2O
]0,
81,
01,
21,
41,
61,
82,
02,
22,
42,
6
[m3/h]
1 1
2
2
4
4
4
3
3
700600
B
C
2
3
1
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6.6, fibreglass-reinforcedRotor: Coated in black; Galvanised
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 20 or IP 42 or IP 44– Insulation class: "B"; "E"– Mounting position: Any– Condensate discharges: None; Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
CBA
C
C
BA
BA
Nominal data
Type Motor
subject to alterations
VDC VDC m3/h rpm W A dB(A) °C
Curve
Nominalvoltage
Voltage
Range
Airflow
Soundlevel
Perm.amb.temp.
Hours
ServiceLifeL 10(40°C)
ebm-papstStandard
Speed/rpm
Powerinput
Currentdraw
p. 30/31
G1)
G1)
Electr.connection
G2)
ServiceLifeL 10(Tmax)
ebm-papstStandard
Lifeexpectancy
L 10∆
(40°C)
Hours
K1G 220 M1G 074-BF
K1G 220 M1G 074-BF
RG 220 54.20; 3ph.
95000 / 58000
82000 / 43000
55000 / 40000
126000
111000
110000
G1)K1G 220 M1G 074-BF 82000 / 43000 111000
G1)K1G 220 M1G 074-BF 95000 / 58000 126000
24 16-28 925 2800 68 3,20 74 -25..+60
48 36-57 1025 3100 94 2,30 78 -25..+60
48 36-72 1250 3500 140 2,90 80 -20..+55
A
B
C
48 36-57 1025 3100 94 2,30 78 -25..+60B
24 16-28 925 2800 68 3,20 74 -25..+60A
2800
2505
2430
2465
3100
2770
2640
2695
3500
3295
3155
3215
68
74
78
76
94
96
98
97
140
160
171
167
3,20
3,46
3,63
3,55
2,30
2,35
2,44
2,39
2,90
3,40
3,64
3,55
74
71
68
70
78
74
71
71
80
77
77
78
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 20
21Guard grillep. 24
Electr. connectionsp. 30 f.
45˚
± 0.5Ø305Ø305 0.5±
± 0.5
Ø294,5
247,5 0.5±
7 ± 0.30.2±Ø5
0.5±270 1.0±92
RG: Connection via single stranded wires AWG 20; TR64;Tach signal and control input AWG22;Cable length 350 mm as of housing
K1G: Cable length 350 mm as of housing, insulation stripped for 85 mm;brass lead tips attached
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable– Protection class: I– Product conforming to standard: EN 60950-1– Approvals: VDE, UL, CSA, CCC are applied for
BA
BA
kg IP
2,35 42
2,35 42
1,87 20
Massofcentrifugal
modulewith
support
basket
Centrifugal module
RG220-44/18/2TDO
K1G 220-AA89 -02
K1G 220-AA67 -02
Type
ofprotection
2,35 44K1G 220-AA67 -04
2,35 44K1G 220-AA89 -04
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 21
22
DC centrifugal modulebackward curved, Ø 225
Curves n[rpm]
P1[W]
LwA[dB(A)]
I[A]
200 400 600 800 1000 1200 1400
0 400 [CFM]200
[Pa]
200
100
400
300
500
600
700
1,0
2,0
[inH 2O
]1,
50,
52,
5
[m3/h]
600 800
A
B
C
11 1
22
2
4
4
4
3
3
3
1
2
3
4
1
2
3
4
1
2
3
4
A
A
A
A
B
B
B
B
C
C
C
C
– Material: Housing: PA plastic 6, fibreglass-reinforcedImpeller: PA plastic 6.6, fibreglass-reinforcedRotor: Coated in black; Galvanised
– Number of blades: 7– Direction of rotation: Clockwise, seen on rotor– Type of protection: IP 20 or IP 42 or IP 44– Insulation class: "B"; "E"– Mounting position: Any– Condensate discharges: None; Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
CBA
CBA
CBA
Nominal data
Type Motor
subject to alterations * Preliminary Service Life
VDC VDC m3/h rpm W A dB(A) °C
Curve
Nominalvoltage
Voltage
Range
Airflow
Soundlevel
Perm.amb.temp.
Hours
ServiceLifeL 10(40°C)
ebm-papstStandard
Speed/rpm
Powerinput
Currentdraw
p. 30/31
G1)
G1)
Electr.connection
G2)
ServiceLifeL 10(Tmax)
ebm-papstStandard
Lifeexpectancy
L 10∆
(40°C)
Hours
K1G 225 M1G 074-BF
K1G 225 M1G 074-BF
RG 225 54.20; 3ph.
100000 / 60000
96000 / 56000
130000
130000
46000* / 34000* 92000*
G1)K1G 225 M1G 074-BF 96000 / 56000 130000
G1)K1G 225 M1G 074-BF 100000 / 60000 130000
24 16-28 1080 2370 72 3,40 72 -25..+60
48 36-57 1140 2500 83 2,00 74 -25..+60
48 36-72 1480 3100 163 3,40 78 -20..+55
A
B
C
48 36-57 1140 2500 83 2,00 74 -25..+60B
24 16-28 1080 2370 72 3,40 72 -25..+60A
2370
2240
2170
2300
2500
2385
2290
2450
3100
2960
2835
2975
72
74
75
71
83
87
88
85
163
171
181
170
3,40
3,44
3,55
3,32
2,00
2,10
2,16
2,05
3,40
3,67
3,91
3,66
72
68
67
69
74
70
68
72
78
75
73
77
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 32 ff.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 22
23Guard grillep. 24
Electr. connectionsp. 30 f.
45˚
± 0.5Ø305Ø305 0.5±
± 0.5
Ø294,5
247,5 0.5±
7 ± 0.30.2±Ø5
0.5±270 1.0±118
RG: Connection via single stranded wires AWG 20; TR64;Tach signal and control input AWG22;Cable length 350 mm as of housing
K1G: Cable length 350 mm as of housing, insulation stripped for 85 mm;brass lead tips attached
– Technical features: • Tach output• Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor pro-tection
– EMC: Interference emission acc. to EN 61000-6-3Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable– Protection class: I– Product conforming to standard: EN 60950-1– Approvals: VDE, UL, CSA, CCC are applied for
BA
BA
kg IP
2,45 42
2,45 42
2,03 20
Massofcentrifugal
modulewith
support
basket
Centrifugal module
RG225-63/18/2TDO
K1G 225-AC49 -02
K1G 225-AC39 -02
Type
ofprotection
2,45 44K1G 225-AC39 -04
2,45 44K1G 225-AC49 -04
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 23
24
Guard grille
a b – Material: PA plastic 6, fibreglass-reinforced
Guard grille for suction side for compact centrifugal modules
Part no. Size
19050-2-2929 190
a b
133,0 9,0
22050-2-2929 220 166,0 8,7
22550-2-2929 225 158,0 8,7
subject to alterations
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 24
25
Capacitors
2357 35
M8a
10 bc
a+3,
5Ø
+10-5
Ø
+5±1
max
.9m
m
– Material: Plastic cap, aluminium cup– Designation: FPU or P2 according to
IEC 252 (non-flammable, non-explosive,circuit-breaking)
– Approval: VDE according to DIN EN 60252(VDE 0560/8)
– Calculated life time:420 V; -25 to +85°C; 30,000 hrs; class A470 V; -25 to +85°C; 10,000 hrs; class B500 V; -25 to +85°C; 3,000 hrs; class C
– Pull-off protector: The housing expandsby max. 9 mm. The protector responds tooverload by the generated excess pressuresnapping off the internal lead in a predeter-mined breaking point.
– Mounting: c is the overall dimension of thecapacitor which has to be taken into accountwhen mounting the part. The capacitordesign, however, depends on the manufac-turer. The expansion (9 mm) is either addedto dimension b, or it is already integrated inthe capacitor.
MKP motor capacitors FPU or P2 (with fuse)Part no. a b (max.) c (max.)Capacity
subject to alterations
02162-4-7320 25-30 104,0 113,0
02163-4-7320 30,0 101,0 110,0
02166-4-7320 35,0 96,0 110,0
02168-4-7320 40,0 96,0 130,0
5,0 µF
6,0 µF
10,0 µF
16,0 µF
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 25
26
Connection leads115 V (UL)
6
a
85
– Plug assignment:1 = green/ yellow2 = blue3 = black4 = brown
Lead connections for AC centrifugal modules (115 V)
Part no.
11530-4-1029
a
450,0
11531-4-1029 1000,0
11532-4-1029 1300,0
11533-4-1029 1600,0
subject to alterations
Connector shell AMP 350 779-4
Jacketed cable, internal leadsUL 1569 / 2517 300V
Brass lead tips
11534-4-1029 2300,0
4 x female terminal AMP 926 884-1
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:54 Seite 26
27
Connection leads230 V
85
a
6
Lead connections for AC centrifugal modules (230 V)
Part no.
23030-4-1012
a
450,0
23031-4-1012 1000,0
23032-4-1012 1300,0
23033-4-1012 1600,0
subject to alterations
23034-4-1012 2300,0
– Plug assignment:1 = green/ yellow2 = blue3 = brown4 = not assigned
Connector shell AMP 350 779-4
Jacketed cable, internal leadsH03VV-F3G0,5 black
Brass lead tips
3 x female terminal AMP 926 884-1
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 27
28
Electrical connections
A1) Single-phase capacitor motor
with TOP wired internally
CNPEL
TOP
21 ZUU
U1 = blue
U2 = black
Z = brown
= green/yellow
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 28
29
+
-
+
-
H1)
Speed setting
PWM 1 - 10 kHz
Speed settingwith variableresistance
Full speed
100% PWM -> n=maxapprox. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 14 %
Speed setting
1 V - 10 V
10 V -> n=maxapprox. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
yellow
white
blue
Lin/PWM control input0-10 VDC / PWM
green/yellowPE
blueNbrownL
red
Voltage output+10 V max. 1.1 mA
Tach output1 pulse per revolution
GND
Isink max. 10 mA
680 Ω47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
Imax =10 mA
Umin = 15 V
1 µF
Mains50/60 Hz
L PEN
Line Connection Colour Assignment / function Line Connection Colour Assignment / function1 2L brown Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Control input (Impedance 100 kΩ)N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
brown green/yellowblue
+10
V
0-10
VPW
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
GND blue
Tach white Tach output: 1 pulse per revolution
GND
Tach
GND
whiteblue
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 29
Electrical connections
30
1 Tach white
0-10 V / PWM yellow Control input (Impedance 100 kΩ)
Tach output:
3 pulses / revolution
G1)
680 Ω
Temperaturecontrol module
50002-1-017450003-1-0174
Speed setting
PWM 1 - 10 kHz
Speed settingwithpotentiometer
Full speed
100% PWM -> n=maxapprox. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 14 %
Speed setting
1 V - 10 V
10 V -> n=maxapprox. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
33 K 4.7 K
10 KPWM
12 V 12 V
U
Speed display
Alarm
Controller
Counter
red
white
blue
Maximum ripple± 3.5%
Tach outputpulses per revolution
GND
Isink max. 10 mA
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
yellow
Lin/PWM control input0-10 VDC / PWM
+
0-10
VPW
M
Tach
GND
Line Connection Colour Assignment / function Line Connection Colour Assignment / function1 + red Maximum ripple ± 3.5 %
GND blue GND
Line 1
red yellowwhiteblue
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 30
31
G2)
U
violet
Temperaturecontrol module
50002-1-017450003-1-0174
Speed setting
PWM 1 - 10 kHz
Speed settingwithpotentiometer
Full speed
100% PWM -> n=maxapprox. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 14 %
Speed setting
1 V - 10 V
10 V -> n=maxapprox. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
33 K 4.7 K
10 KPWM
12 V 12 V Speed display
Alarm
Controller
Counter
red
white
blue
Maximum ripple± 3.5%
Tach outputpulses per revolution
GND
Isink max. 10 mA
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
Lin/PWM control input0-10 VDC / PWM
1 Tach white
0-10 V / PWM violet Control input (Impedance 100 kΩ)
Tach output:
3 pulses / revolution
+
0-10
VPW
M
Tach
GND
Line Connection Colour Assignment / function Line Connection Colour Assignment / function1 + red Maximum ripple ± 3.5 %
GND blue GND
Line 1
red violetwhiteblue
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 31
32
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
General performance parameters
Any deviations from the technical data and parameters described here
are listed on the product-specific data sheet.
Type of protection
The type of protection is specified in the product-specific data sheets.
Insulation class
The insulation class is specified in the product-specific data sheets.
Mounting position
The mounting position is specified in the product-specific data sheets.
Condensate discharge holes
Information on the condensate discharge holes is provided in the
product-specific data sheets.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Protection class
The protection class is specified in the product-specific data sheets..
Service life
The service life of ebm-papst products depends on two major factors:
– The service life of the insulation system
– The service life of the bearing system
The service life of the insulation system mainly depends on voltage level,
temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
on the bearing.
The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
used, which is indicated on the product-specific data sheet wherever
applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
operating hours at an ambient temperature of 40 °C, yet this estimate
can vary according to the actual ambient conditions.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
product-specific data sheets.
Depending on motor type and field of application, the following protective
features are realised:
– Thermal overload protection (TOP), either in-circuit or external
– PTC with electronic diagnostics
– Impedance protection
– Thermal overload protection (TOP) with electronic diagnostics
– Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 32
33
Legal and normative directives
The products described in this catalogue are designed, developed and
produced in keeping with the standards in place for the relevant product
and, if known, the conditions governing the relevant fields of application.
Standards
Information on standards is provided in the product-specific data sheets.
EMC
Information on EMC standards is provided in the product-specific data
sheets.
Complying with the EMC standards has to be established on the final
appliance, as different mounting situations can result in changed EMC
properties.
Leakage current
Information on the leakage current is provided in the product-specific
data sheets.
Measuring is according to IEC 60990.
Approvals
In case you require a specific approval for your ebm-papst product
(VDE, UL, GOST, CCC, CSA, etc.) please let us know.
Most of our products can be supplied with the relevant approval.
Information on existing approvals is provided in the product-specific
data sheets.
Air performance measurements
All air performance measurements are carried out on suction side and on
chamber test beds conforming to the specifications as per ISO 5801 and
DIN 24163. The fans under test are installed in the measuring chamber at
free air intake and exhaust (installation category A) and are operated at
nominal voltage, with AC also at nominal frequency, and without any
additional components such as guard grilles.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
Left: Endurance test roomMiddle: Shock test
Right: Chamber test rig
Mechanical strain / performance parameters
All ebm-papst products are subjected to comprehensive tests complying
with the normative specifications. In addition to this, the tests also reflect
the vast experience and expertise of ebm-papst.
Vibration test
Vibration tests are carried out in compliance with
– Vibration test in operation according to DIN IEC 68, parts 2-6
– Vibration test at standstill according to DIN IEC 68, parts 2-6
Shock load
Shock load tests are carried out in compliance with
– Shock load according to DIN IEC 68, parts 2-27
Balancing quality
Testing the balancing quality is carried out in compliance with
– Residual imbalance according to DIN ISO 1940
– Standard balancing quality level G 6.3
Should you require a higher balancing quality level for your specific
application, please let us know and specify this when ordering your
product.
Chemo-physical strain / performance parameters
Should you have questions about chemo-physical strain, please direct
them to your ebm-papst contact.
Fields of application, industries and applications
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room
technology, automotive and rail technology, medical and laboratory tech-
nology, electronics, computer and office technology, telecommunications,
household appliances, heating, machines and plants, drive engineering.
Our products are not designed for use in the aviation and aerospace
industry!
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 33
34
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
– Axial and diagonal fans in direction of rotation “V” in full nozzle and
without guard grille
– Backward curved centrifugal fans, free-running and with inlet nozzle
– Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All acoustic values are established according to ISO 13347, DIN 45635
and ISO 3744/3745 to accuracy class 2 and given in A-rated form.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (Lw), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
(see graphic). The sound level measured can be roughly calculated
from the sound pressure level by adding 7 dB.
Measuring configuration as per ISO 13347-3 respectively DIN 45635-38:
10 measuring points
d ≥ Dh = 1,5d ... 4,5d
Measurement area S = 6d2 + 7d (h + 1,5d)
3d
2d
h
D
1,5d
Room for precision noise measuring
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 34
35
Adding multiple noise sources with the same level
Adding 2 noise sources with the same volume results in a level increase of approx. 3 dB.
The noise characteristics of multiple identical fans can be determined in advance based on
the noise values specified in the data sheet. This is shown in the diagram opposite.
Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound
pressure level of a fan is approximately 75 dB(A). The level increase measured from the dia-
gram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A).
Adding two noise sources with different levels
The acoustic performance of two different fans can be predetermined based on the sound
levels given in the data sheet. This is shown in the diagram opposite.
Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper-
ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is
4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that
the overall sound level of the unit can be expected to be 76.5 dB(A).
Distance laws
Sound power level is independent of distance to the sound source. In contrast to this, sound
pressure level decreases the further away the noise source is. The adjacent diagram shows
the decrease in level under far sound field conditions. Far sound field conditions apply when-
ever the distance between microphone and fan is big when compared to fan diameter and
wavelength to be considered. For more information on far sound field, please consult the rele-
vant literature on this complex topic. Per doubling of distance, the level in the far sound field
decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in
levels can be considerably smaller. The following example only applies to far sound field
conditions and can vary strongly depending on the installation effects:
With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of
1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by
26 dB, i.e. a sound pressure level of 39 dB(A).
1510 15 20 255 82
105
90
1
[dB]
Number of sources of sound with identical level
Incr
ease
inso
und
pres
sure
/sou
ndpo
wer
leve
l
3
12 16 20 2484
21
1,5
0
0
[dB]
[dB]
Difference in level with two sources of sound
Incr
ease
inso
und
pres
sure
/sou
ndpo
wer
leve
l
0
10 20 50 10052
-10
-26
-20
-30
-40
1
[m]
[dB]
Distance
Decr
ease
inso
und
pres
sure
leve
l
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 35
36
fan agent
compact fan agent
motor specialist
motor agent
Germany
ebm-papstMulfingen GmbH & Co. KG
Bachmühle 2D-74673 MulfingenPhone +49 7938 81-0Fax +49 7938 81-110info1@de.ebmpapst.com
www.ebmpapst.com
ebm-papstSt. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1D-78112 St. GeorgenPhone +49 7724 81-0Fax +49 7724 81-1309info2@de.ebmpapst.com
www.ebmpapst.com
ebm-papstLandshut GmbH
Hofmark-Aich-Straße 25D-84030 LandshutPhone +49 871 707-0Fax +49 871 707-465info3@de.ebmpapst.com
www.ebmpapst.com
KasselDipl.-Ing. (FH) Ralph BrückHoherainstraße 3 bD-35075 GladenbachPhone +49 6462 4071-10Fax +49 6462 4071-11Ralph.Brueck@de.ebmpapst.com
KoblenzWinfried SchaeferHinter der Kirch 10D-56767 UersfeldPhone +49 2657 16-96Fax +49 2657 16-76Winfried.Schaefer@de.ebmpapst.com
MunichDipl.-Wirt.-Ing. (FH) Jens PeterUhlandstraße 6D-74427 FichtenbergPhone +49 7971 260-180Fax +49 7971 260-221Jens.Peter@de.ebmpapst.com
NurembergFriedrich KleinAdlerstraße 49/1D-73540 HeubachPhone +49 7173 4983Fax +49 7173 8053Friedrich.Klein@de.ebmpapst.com
OffenburgDipl.-Ing. (FH) Ralf BraunHubeneck 21D-77704 OberkirchPhone +49 7802 9822-52Fax +49 7802 9822-53Ralf.Braun@de.ebmpapst.com
StuttgartDipl.-Ing. (FH) Rudi WeinmannHindenburgstraße 100/1D-73207 PlochingenPhone +49 7153 9289-80Fax +49 7153 9289-81Rudi.Weinmann@de.ebmpapst.com
UlmDipl.-Wirt.-Ing. (FH) Axel ReschBachmühle 2D-74673 MulfingenPhone +49 7938 81-7092Fax +49 7938 81-110Axel.Resch@de.ebmpapst.com
Distributors
FrankfurtR.E.D. Handelsgesellschaft mbHGutenbergstraße 3D-63110 Rodgau - JügesheimPhone +49 6106 841-0Fax +49 6106 841-111info@red-elektromechanik.dewww.red-elektromechanik.de
HamburgBreuell + Hilgenfeldt GmbHGrützmühlenweg 40D-22339 HamburgPhone +49 40 538092-20Fax +49 40 538092-84info@breuell-hilgenfeldt.de
MunichA. Schweiger GmbHOhmstraße 1D-82054 SauerlachPhone +49 8104 897-0Fax +49 8104 897-90info@schweiger-gmbh.dewww.schweiger-gmbh.com
(1 to 5 pieces)
NorthBreuell + Hilgenfeldt GmbHGrützmühlenweg 40D-22339 HamburgPhone +49 40 538092-20Fax +49 40 538092-84ebmpapst@breuell-hilgenfeldt.de
SouthHDS Ventilatoren Vertriebs GmbHGlaswiesenstraße 1D-74677 DörzbachPhone +49 7937 8033520Fax +49 7937 8033525info@hds-gmbh.net
Agencies
BerlinDipl.-Ing. (TH) Jens DuchowHändelstraße 7D-16341 PanketalPhone +49 30 944149-62Fax +49 30 944149-63Jens.Duchow@de.ebmpapst.com
BielefeldDipl.-Ing. (FH) Wolf-Jürgen WeberNiehausweg 13D-33739 BielefeldPhone +49 5206 91732-31Fax +49 5206 91732-35Wolf-Juergen.Weber@de.ebmpapst.com
DortmundDipl.-Ing. (FH) Hans-Joachim PundtAuf den Steinern 3D-59519 Möhnesee-VöllinghausenPhone +49 2925 800-407Fax +49 2925 800-408Hans-Joachim.Pundt@de.ebmpapst.com
FrankfurtDipl.-Ing. Christian KleffmannDr.-Hermann-Krause-Straße 23D-63452 HanauPhone +49 6181 1898-12Fax +49 6181 1898-13Christian.Kleffmann@de.ebmpapst.com
HalleDipl.-Ing. (TU) Michael HanningLerchenweg 4D-06120 LieskauPhone +49 345 55124-56Fax +49 345 55124-57Michael.Hanning@de.ebmpapst.com
HamburgIngenieurbüro Breuell GmbHIng. Dirk KahlElektroingenieurGrützmühlenweg 40D-22339 HamburgPhone +49 40 538092-19Fax +49 40 538092-84Dirk.Kahl@de.ebmpapst.com
ebm-papst representatives & subsidiaries
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 36
37
Europe
Austriaebm-papst Motoren & Ventilatoren GmbHStraubingstraße 17A-4030 LinzPhone +43 732 321150-0Fax +43 732 321150-20info@at.ebmpapst.comwww.ebmpapst.at
Belarusebm-papst Bel AgmbHP.O. Box 117BY-220138 MinskPhone +375 17 3851556Fax +375 17 3851556info@by.ebmpapst.comwww.ebmpapst.by
Belgiumebm-papst Benelux B.V.Sales office Belgium-LuxemburgRomeinsestraat 6/0101Research Park HaasrodeB-3001 Heverlee-LeuvenPhone +32 16 396-200Fax +32 16 396-220info@be.ebmpapst.comwww.ebmpapst.be
Bulgariaebm-papst Romania S.R.L.Str. Tirnavei Nr. 20RO-500327 BrasovPhone +40 268 312-805Fax +40 268 312-805dudasludovic@xnet.ro
Croatiaebm-papst Industries Kft.Ezred u. 2.H-1044 BudapestPhone +36 1 8722-190Fax +36 1 8722-194office@hu.ebmpapst.com
Czech Republic / Slovakiaebm-papst CZ s.r.o.Kaštanová 34aCZ-620 00 BrnoPhone +420 547 232-617Fax +420 547 232-622info@ebmpapst.czwww.ebmpapst.cz
Denmarkebm-papst Denmark ApSVallensbækvej 21DK-2605 BrøndbyPhone +45 43 631111Fax +45 43 630505mail@dk.ebmpapst.comwww.ebmpapst.dk
Estoniaebm-papst Oy, Eesti FiliaalKesk tee 13Aaviku küla, Jüri TehnoparkEST-75301 Rae Vald, HarjumaaPhone +372 65569-78Fax +372 65569-79www.ebmpapst.ee
Finlandebm-papst OyPuistotie 1FIN-02760 EspooPhone +358 9 887022-0Fax +358 9 887022-13mailbox@ebmpapst.fiwww.ebmpapst.fi
Franceebm-papst SARLZI Nord - rue A. MohlerBP 62F-67212 Obernai-CedexPhone +33 820 326266Fax +33 3 88673883info@ebmpapst.frwww.ebmpapst.fr
GreeceHelcomaTh. Rotas & Co OEDavaki 65GR-17672 Kallithea-AttikiPhone +30 210 9513-705Fax +30 210 9513-490contact@helcoma.grwww.helcoma.gr
Hungaryebm-papst Industries Kft.Ezred u. 2.H-1044 BudapestPhone +36 1 8722-190Fax +36 1 8722-194office@hu.ebmpapst.com
IcelandRJ EngineersStangarhyl 1AIS-110 ReykjavikPhone +354 567 8030Fax +354 567 8015rj@rj.iswww.rj.is
Irelandebm-papst LimitedPortlaoise Business & Technology ParkMountrath RoadIRL-Portlaoise, Co. LaoisPhone +353 5786 643-43Fax +353 5786 643-46sales@ie.ebmpapst.comwww.ebmpapst.ie
Italyebm-papst SrlVia Cornaggia 108I-22076 Mozzate (Co)Phone +39 0331 836201Fax +39 0331 821510info@it.ebmpapst.comwww.ebmpapst.it
Macedoniaebm-papst Industries Kft.Ezred u. 2.H-1044 BudapestPhone +36 1 8722-190Fax +36 1 8722-194office@hu.ebmpapst.com
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 37
38
ebm-papst representatives & subsidiariesfan agent
compact fan agent
motor specialist
motor agent
Russiaebm-papst Ural GmbHPosadskaja-Strasse, 23(E), 3RU-620102 EkaterinburgPhone +7 343 2338000Fax +7 343 2337788Konstantin.Molokov@ru.ebmpapst.comwww.ebmpapst.ur.ru
ebm-papst Rus GmbHproezd 4529, vladenie 5, stroenie 1RU-141000 Mytistschi, Oblast MoskauPhone +7 495 9807524Fax +7 495 5140924info@ebmpapst.ruwww.ebmpapst.ru
Serbia & Montenegroebm-papst Industries Kft.Ezred u. 2.H-1044 BudapestPhone +36 1 8722-190Fax +36 1 8722-194office@hu.ebmpapst.com
Spainebm-papst Ibérica S.L.Avda. del Sistema Solar, 29E-28830 San Fernando de Henares (Madrid)Phone +34 91 6780894Fax +34 91 6781530ventas@ebmpapst.es
Swedenebm-papst ABÄggelundavägen 2S-17562 JärfällaPhone +46 8 7619400Fax +46 8 362306info@ebmpapst.sewww.ebmpapst.se
Switzerlandebm-papst AGRütisbergstrasse 1CH-8156 OberhasliPhone +41 44 73220-70Fax +41 44 73220-77verkauf@ebmpapst.chwww.ebmpapst.ch
TurkeyAkantel Elektronik San. Tic. LTD. Sti.Atatürk Organize SanayiBölgesi 10007 SK. No.:6TR-35620 Cigli-IzmirPhone +90 232 3282090Fax +90 232 3280270akantel@akantel.com.trwww.ebmpapst.com.tr
Ukraineebm-papst Ukraine LLCLepse Boulevard, 4, Building 47UA-03067 KievPhone +38 044 2063091Fax +38 044 2063091mail@ebmpapst.uawww.ebmpapst.ua
United Kingdomebm-papst UK Ltd.Chelmsford Business ParkGB-Chelmsford Essex CM2 5EZPhone +44 1245 468555Fax +44 1245 466336sales@uk.ebmpapst.comwww.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.The SmithyFidlers Lane, East IlsleyGB-Berkshire RG20 7LGPhone +44 1635 2811-11Fax +44 1635 2811-61A&Dsales@uk.ebmpapst.comwww.ebmpapst-ad.com
Netherlandsebm-papst Benelux B.V.Engelseweg 127NL-5705 AC HelmondPhone +31 492 502-900Fax +31 492 502-950verkoop@nl.ebmpapst.comwww.ebmpapst.nl
Norwayebm-papst ASP.B. 173 HolmliaN-1203 OsloPhone +47 22 763340Fax +47 22 619173mailbox@ebmpapst.nowww.ebmpapst.no
Polandebm-papst Polska Sp. z o.o.ul. Annopol 4APL-03236 WarszawaPhone +48 22 6757819Fax +48 22 6769587office@ebmpapst.plwww.ebmpapst.pl
Portugalebm-papst (Portugal), Lda.Av. Marechal Gomes da Costa, 35 eRua Conselheiro Emidio NavarroP-1800-255 LisboaPhone +351 218 394-880Fax +351 218 394-759info@pt.ebmpapst.comwww.ebmpapst.pt
Romaniaebm-papst Romania S.R.L.Str. Tirnavei Nr. 20RO-500327 BrasovPhone +40 268 312-805Fax +40 268 312-805dudasludovic@xnet.ro
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 38
39
America
Argentinaebm-papst de Argentina S.A.Hernandarias 148 Lomas del MiradorPcia. de Buenos Aires (1752)Phone +54 11 46576135Fax +54 11 46572092ventas@ar.ebmpapst.comwww.ebmpapst.com.ar
Brasilebm-papst Motores Ventiladores Ltda.Av. José Giorgi, 301 Galpões B6+B7Condominio Logical CenterBR-06707-100 Cotia - São PauloPhone +55 11 4613-8700Fax +55 11 3164-8924vendas@br.ebmpapst.comwww.ebmpapst.com.br
Canadaebm-papst Canada Inc.1800 Ironstone Manor, Unit 2CDN-Pickering, Ontario, L1W3J9Phone +1 905 420-3533Fax +1 905 420-3772sales@ca.ebmpapst.comwww.ebmpapst.ca
Mexicoebm Industrial S.de R.L. de C.V.Paseo de Tamarindos 400-A-5to PisoCol. Bosques de las LomasMEX-Mexico 05120, D.F.Phone +52 55 3300-5144Fax +52 55 3300-5243sales@mx.ebmpapst.comwww.ebmpapst.com.mx
USAebm-papst Inc.P.O. Box 4009100 Hyde RoadUSA-Farmington, CT 06034Phone +1 860 674-1515Fax +1 860 674-8536sales@us.ebmpapst.comwww.ebmpapst.us
ebm-papst Automotive & Drives, Inc.3200 Greenfield, Suite 255USA-Dearborn, MI 48120Phone +1 313 406-8080Fax +1 313 406-8081automotive@us.ebmpapst.comwww.ebmpapst-automotive.us
Africa
South Africaebm-papst South Africa (Pty) Ltd.P.O. Box 31241119 Yacht AvenueZA-2040 HoneydewPhone +27 11 794-3434Fax +27 11 794-5020info@za.ebmpapst.comwww.ebmpapst.co.za
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 39
40
ebm-papst representatives & subsidiariesfan agent
compact fan agent
motor specialist
motor agent
Asia
Chinaebm-papst Ventilator (Shanghai) Co., Ltd.No. 418, Huajing RoadWaiGaoQiao Free Trade ZoneNo. 2001, Yang Gao (N) RoadVRC-200131 Shanghai, P.R. of ChinaPhone +86 21 5046-0183Fax +86 21 5046-1119sales@cn.ebmpapst.comwww.ebmpapst.com.cn
Hong Kongebm-papst Hong Kong Ltd.Unit No. 13,9 / FTechnology Park, 18 On Lai StreetSiu Lek Yuen, Shatin N.T.Hong Kong - P.R. of ChinaPhone +852 2145-8678Fax +852 2145-7678info@hk.ebmpapst.com
Indiaebm-papst India Pvt. Ltd.26/3, G.N.T. Road, ErukkencherryIND-Chennai-600118Phone +91 44 25372556Fax +91 44 25371149sales@in.ebmpapst.comwww.ebmpapst.in
Indonesiaebm-papst IndonesiaRepresentative OfficeGerman Centre, 4th Floor, Suite 4470Jl. Kapt. Subijono Dj. Bumi Serpong DamaiRI-15321 TangerangPhone +62 21 5376250Fax +62 21 5388305salesdept@id.ebmpapst.com
IsraelPolak Bros. Import Agencies Ltd.9 Hamefalsim StreetIL-Kiryat Arie, Petach-Tikva 49514Phone +972 3 9100300Fax +972 3 5796679polak@polak.co.ilwww.polak.co.il
Japanebm-papst Industries Japan K.K.12 Floor, Benex S-3 Bldg.3-20-8 Shinyokohama, Kohoku-kuJ-222-0033 YokohamaPhone +81 45 47057-51Fax +81 45 47057-52info@jp.ebmpapst.comwww.ebmpapst.jp
Koreaebm-papst Korea Co. Ltd.6F, Trutec Bldg.B 6-2, Digital Media City (DMC)Sangam-Dong, Mapo-GuROK-Seoul 121-270Phone +82 2 366213-24Fax +82 2 366213-26info@kr.ebmpapst.comwww.ebmpapst.co.kr
Malaysiaebm-papst MalaysiaRepresentative OfficeUnit 12-2, Jalan USJ Sentral 3Persiaran Subang, Selangor Darul EhsanMAL-47600 Subang JayaPhone +60 3 8024-1680Fax +60 3 8024-8718salesdept@my.ebmpapst.com
Singaporeebm-papst SEA Pte. Ltd.No. 23 Ubi Road 4#06-00 Olympia Industrial BuildingSGP-Singapore 408620Phone +65 65513789Fax +65 68428439salesdept@sg.ebmpapst.com
TaiwanETECO Engineering & Trading Corp.10F-I, No. 92, Teh-Wei Str.RC-Tsow-Inn District, KaohsiungPhone +886 7 557-4268Fax +886 7 557-2788eteco@ms22.hinet.netwww.ebmpapst.com.tw
Thailandebm-papst Thailand Co., Ltd.99/349 Na-Nakorn Bldg., 4th FloorChaeng Wattana Road, Thungsonghong,THA-10210 Laksi, BKKPhone +66 2 57615-24Fax +66 2 57615-42salesdept@th.ebmpapst.com
United Arab Emiratesebm-papst Middle East FZEPO Box 17755Jebel Ali Free Zone / FZS1 / AP05UAE-DubaiPhone +971 4 88608-26Fax +971 4 88608-27info@ae.ebmpapst.comwww.ebmpapst.ae
Vietnamebm-papst VietnamRepresentative OfficeRoom #102, 25 Nguyen Van Thu StreetDistrict 1VN-Ho Chi Minh CityPhone +84 8 39104099Fax +84 8 39103970linh.nguyen@vn.ebmpapst.com
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 40
41
Australia
Australiaebm-papst A&NZ Pty Ltd.10 Oxford RoadAUS-Laverton North, Victoria, 3026Phone +61 3 9360-6400Fax +61 3 9360-6464sales@ebmpapst.com.auwww.ebmpapst.com.au
New Zealandebm-papst A&NZ Pty Ltd.102 Henderson Valley RoadNZ-Henderson, Auckland 1230Phone +64 9 837-1884Fax +64 9 837-1899sales@ebmpapst.com.auwww.ebmpapst.com.au
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 41
42
Notes
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 42
43
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 43
37816-7-8811 · RA-10/09-3’Printed in Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com
www.ebmpapst.com
Kompakt_Radialventilatoren_EN_06_2010_:Vorlage 06.07.2010 17:55 Seite 44