ElectromaxElectromax provides efficient electric wet central heating
and domestic hot water with the comfort and control of
gas-powered systems, making it a perfect solution for over
two million homes in Britain with no mains gas supply.
Electromax includes a programmable room thermostat to take full
advantage of off-peak electricity rates. It uses standard radiators
and thermostatic radiator valves to reduce the cost of installation.
To complement the range an underfloor heating version is also
available. With long-term costs in mind, there is no need for the
considerable expense and inconvenience of an annual gas safety
certificate.
Electromax comes with a 10 year cylinder guarantee and a two year
guarantee for the boiler and all other controls with on-site service
support.
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
54
Electromax installation
Discharge pipe
Auto air vent
Pressurereliefvalve
Temperatureand pressurerelief valve
Pump
Flow
CylinderElectric boiler
Cold watercombination
valve (supplied)
Coldmainsfeed
To hotoutlets
Return
Automaticbypass valve
Primaryexpansion
vessel
Potable waterexpansion vessel(supplied)
Connectionto radiators
or underfloorsystem
7
910
6
2
4
8
5
3
17
16
4
11
15 1
12
13
14
Electromax
Electromax has a host of features that benefit developers, builders, installers, landlords and end users to make it a desirable alternative where gas is not available or not the preferred option.
• Controllable,efficientwetcentralheating.
• Programmableroomthermostattoaccommodatea wide range of off-peak tariffs.
• Usesstandardradiatorsandthermostaticradiatorvalves.
• Designedforsealedsystems.
• Modelavailableforunderfloorheatingsystems.
• High-performancedomestichotwaterfromunvented direct hot water cylinder.
• CylindermanufacturedfromDuplexstainlesssteel.
• Noflueandnofueltanksallowflexibleinstallationlocation.
• Silentinoperation.
• Automaticpumpexercisefeature–forperiodswhen boiler is switched off.
• Frontcontrolpanelindicationtoshowboilerstatus.
• Provensolid-statetechnologyforlonglife.
• Softstartandzerovoltswitchingtoavoidpowersurges.
• Min/maxcontroladjuststhewatertemperatureoutput from the boiler.
• Minimalserviceandmaintenancecosts.
• Norequirementforannualgassafetycertificate.
• On-sitepartsandlabourguarantee. –Cylinder–10years. –Boilerandothercontrols–twoyears.
Key components 1 6or9kWAmptecboiler.
2 Controls(PCBs).
3 180litrecylinder(Duplexstainlesssteel).
4 Elements–alloy825sheathed,incorporating thermalcontrols–combinedthermostatandthermalcut-out.Thermostatadjustable between 10°C and 70°C.
5 Insulation–CFC/HCFCFree(ODPzero)expanded polyurethane.
6 Userinterfacecontrolsmountedinstylised facia panel.
7 Expansion vessel.
8 Pressurereliefvalve.
9 Circulating pump.
10 Autoairvent.
11 Automaticbypassvalve.
12 Programmableroomthermostat.
13 Combinedpressurereducing/strainer/check/expansionvalve.
14 Externally mounted potable water expansionvessel(18litre)supplied with wall mounting bracket.
15 Tundish.
16 Drainvalve.
17 Primarysystemisolatingvalves.
Central heating
Electromax is suitable for use with wet radiator or underfloor sealed heating systems. Typical system layout given below is for illustrative purposes only.
Domestic hot water
Domestichotwater isprovidedbya180 litreunventeddirecthotwater cylinderwhichismanufacturedfromDuplexstainlesssteelformaximumstrengthandlonglife. Duplex stainless steel offers a superior resistance to corrosion especially inaggressive water areas, compared with copper, glass-lined steel and some lower grades of stainless steel.
BecauseDuplexisalowcarbon,highchromiumcontentalloy,itresistsallformsofcorrosion including pitting, crevice corrosion, uniform corrosion and stress corrosion cracking, without the use of a sacrificial anode. In addition, the combination of tungsten inert gas and laser welding coupled with the special post-weld processes ensures the same level of corrosion resistance and mechanical strength as the parent metal. This ensures the longest possible working life for every cylinder.
Thewaterisheatedbylong-lifeSuperloy825alloysheathedelementsincorporatedinto an easily removable heater plate, making replacement simple, if necessary.
Electromax is supplied with a programmable room thermostat which controls the time periods that the boiler comes into operation and the room temperature. Offering up to three ‘On’ and three ‘Off’ periods per day and Weekday andWeekend programmes, the user is able to take advantage of the most appropriate off peak tariff best suited to their needs.
The control panel on the unit includes a system pressure gauge, boiler indicator LEDs,boileron/offswitch,domestichotwateron/offandboostswitches.
Running costs
There are a number of off-peak electricity tariffs now available which provide a range of lower cost options for electricity used for heating and hot water. The two most common tariffs are Economy 7 and Economy 10. Types of meter and tariffs will vary by property and region. The following information is for general guidance only.
Economy 7Two ratemeter installed in property. Units used at night (during off-peak time*)charged at lower rate than those used during the day.
Economy 10†
Only onemeter installed in each property. All electricity used at off-peak timeschargedat the lower rate (suchaswashingmachines,dishwashersetc).Off-peaktimesgenerallysetformidnight–5.00am;1.00pm–4.00pm;and8.00pm–10.00pm.
*”Night” means the 7 hours that the local distribution company in your area chooses between 10pm and 10am. “Day” means at all other times. †Not available in all areas, and details may vary by area.
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
76
DimensionsSpecificationCapacitiesBoiler–1.3litres. Cylinder–180litres.
RatingsBoilers– 6kW@240V(5.5kW@230V). – 9kW@240V(8.3kW@230V). Immersionheaters–2x3kW@240V(2x2.8kW@230V).
ElementsBoiler–Longlife,lowwattsdensity,copperelementsin a copper heat exchanger. Cylinder–LonglifeSuperloy825alloysheathedelements incorporated into an easily removable heater plate should replacement be necessary.
Outer casingWhite stove-enamelled corrosion-resistant steel. ControlPanelfascia–lightgreyABS.
Thermal insulationBoiler:Armaflex–closedcellinsulation.Dust,fibreandCFC/HCFCfree(ODPzero). Cylinder–CFC/HCFCFree(ODPzero)expandedpolyurethane.GWP2.72(GlobalWarmingPotential).
ThermostatElectromaxboiler–Electronicdualcontrol,useradjustablefrom65°Cto80°C. Electromaxunderfloorboiler–Electronicdualcontrol,useradjustablefrom30°Cto60°C. Electromaxcylinder–elementthermostatadjustablefrom 10°C to 70°C.
Water containerBoiler–Copper. Cylinder–Duplex2304(Grade1.4362EN10088)stainless steel with external expansion vessel.
Safety featuresBoiler–2ampfusedpumpsupply,dualcontrolcircuits,dual switching of the elements, self-check circuitry and fault indication. Resettable thermal cut-out. Cylinder–Manuallyresettablecut-outonheatingelementoperatesat85°C(featureisanintegralpart ofthethermostat).
Primary circuitPressurereliefvalvefactorysetto3bar.Cylinderfittedwith temperature and pressure relief valve, factory-set tooperateat10bar/90°C.
PumpGrundfosUPS15-50(withintegralautomaticairvent).
Expansion vesselsPrimarysystemexpansionvessel(12litre/3bar)factoryfitted.Potablewaterexpansionvessel (18litre/3.5bar)suppliedloose.
Bypass valveAutomaticbypassvalve(factory-fitted).
Central heating controlsSuppliedwithprogrammableroomthermostat–three‘On’/three‘Off’periodsperday.Weekdayandweekend can be programmed separately. Battery operated.Polarity-freeconnectiontoboiler.
ApprovalsNemkoapproved,CEmarked. ManufacturedintheUKinaBSENISO9001:2008, ISO14001:2004andBSOHSAS18001:2007registeredfactory.
InstallationMustbeinstalledbyacompetentinstallerinaccordance with Local Regulations. EnglandandWales–BuildingRegulationsG3.Scotland–TechnicalStandardsP3. N.Ireland–BuildingRegulationsP5.
FixingFloor-mounting.Atemplateisprovidedtoassist in positioning.
Plumbing connections22mmpipeworkonconnectionsonallmodels. Primaryfillingloopandprimarydrainpointvalve and hose connector supplied, bottom or side entry via panel knock outs.
Primary system operating pressure3barmaximum.
Operating temperaturePrimarysystem–Electromaxfrom65°Cto80°C.
Primarysystem–ElectromaxUnderfloorfrom30°C to 60°C. Cylinder from 10°C to 70°C.
Heating systemsSealedsystems.
Pressure testingTestedto15bar.
Cold water controlIntegrated cold water control set comprising pressure reducingvalveandstrainer(factorysetat3.5bar),expansionreliefvalve(factorysetat6bar)andcheckvalve.22mmcompressionfittings.
Domestic hot water f ow ratesUpto55litresperminute@6barpressure.
Min water requirementsRecommendedminimumsupplypressure– 1.5bar/20l/minflowrate.Ifthereareanydoubtsabout water supply pressure or flow rates, please contactourSpecificationAdviceTeamtodiscuss.
TundishFactory-fitted15mminletand22mmcompressionoutlet.
ElectricalDesignedforconnectiontooff-peakelectricitysupply.Arangeofoff-peaktariffsareavailablenationally–itisrecommended that you contact your electricity supplier to determine the tariff best suited to your needs.
Electric boiler must be permanently connected to electricity supply through a double pole linked isolating switch with a minimum breaking capacity of45amps.
Immersion heaters must be permanently connected to electricity supply through a double pole linked isolating switch with a minimum breaking capacity of13amps.
Central heating control is by means of a programmable roomthermostat(suppliedlooseforfittingonsite).
User controlsThe unit is supplied with a programmable room thermostat for the control of the central heating times and temperature.
Control panelBoileron/offswitch.Hotwateron/offswitch. Hotwateronehourboostswitch.Systempressuregauge.Boilertemperatureadjustment.BoilerLEDindicators.
GuaranteeTheElectromaxDuplexstainlesssteelvesselcarriesafull 10 year guarantee against faulty manufacture or materials provided that:
• Ithasbeencorrectlyinstalledaspertheinstructions contained in the instruction manual andallrelevantCodesofPracticeandRegulationsin force at the time of installation.
• IthasbeeninstalledintheUK.
• Ithasnotbeenmodifiedinanyway,otherthanbyHeatraeSadiaHeating.
• Ithasnotbeenfrostdamaged.
• Ithasonlybeenusedforthestorageofpotablewater.
• Ithasnotbeentamperedwithorbeensubjectedto misuse or neglect.
• Within60daysofinstallationtheusercompletesand returns the certificate supplied along with the proof of purchase to register the product.
The boiler, immersion heater and controls are guaranteed for a period of two years from the date of purchase provided that:
• Ithasbeencorrectlyinstalledaspertheinstructions contained in the instruction manual andallrelevantCodesofPracticeandRegulationsin force at the time of installation.
• IthasbeeninstalledintheUK.
• Ithasnotbeenmodifiedinanyway,otherthanbyHeatraeSadiaHeating.
• Ithasnotbeenfrostdamaged.
• Ithasnotbeentamperedwithorbeensubjectedto misuse or neglect.
• Within60daysofinstallationtheusercompletesand returns the certificate supplied along with the proof of purchase to register the product.
Evidence of purchase and date of supply must be submitted. These guarantees do not affect your statutory rights.
Fullspecifications Dimensionsandordering
Model
Electromax/ElectromaxUnderfloor
B C300 minimumclearance overtop panel
50 min. clearance
A
A (mm)
1480
B (mm)
550
C (mm)
605
Ordering guideModel
Electromax
Electromax
Electromax Underfloor
Electromax Underfloor
Rating @ 240V
Boiler Cylinder
6kW 2x3kW
9kW 2x3kW
6kW 2x3kW
9kW 2x3kW
Capacity (litre)
Boiler Cylinder
1.3 180
1.3 180
1.3 180
1.3 180
Weight (kg)
Empty Full
74 256
74 256
74 256
74 256
Product code
95:022:204
95:022:203
95:022:304
95:022:303
Cylinder performanceModel
Electromax
Electromax Underfloor
Capacity
(litre)
180
180
Off-peak heater 3kW
Time to heat (mins)
Thro’ 45ºC Thro’ 50ºC
180 200
180 200
Boost heater 3kW
Quantity heated thro’
45ºC in 60 mins
57litres
57litres
Heat loss
kWh/24h
1.95
1.95
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
98
Solarenergyisafree,naturalandinexhaustibleresource
that we can exploit as the technology to do so becomes
moreaffordable.ElectromaxSolarisaprimeexampleof
this new eco-friendly technology.
ElectromaxSolar,combinedelectricboileranddomestichotwaterstore,usesasustainable
energy sourcewhich is free andnatural. Providing an attractive lower carbonoption for
specifiers,developers, homeownersand tenantsalike theElectromaxSolar reduces the
amount of electricity required to generate domestic hot water. In addition to reducing
carbon emissions, real cost savings can be made over the medium and long term when
switching to sustainable energy sources.
Whetherinruralareas,newhousingprojects,multi-floordwellingsoroneofthetwomillion
homes inBritainwithnomainsgas supply,ElectromaxSolaroffers thebest solution for
comfort and convenience of wet central heating. The benefits of domestic solar thermal
hot water are powerful mains pressure showering and faster filling baths.
Withthesamecomfortandcontrollabilityasagasboiler,ElectromaxSolarprovidescentral
heatingonlywhenrequiredandiscontrolledbyaprogrammableroomthermostatwhich
can be set to take advantage of off-peak electricity tariffs and meet end user life styles.
It is available in both radiator and underfloor options.
The Electromax Solar is ideal for a range of domestic properties and especiallysuitedwherethere isnomainsgassupply.Aninstallationtemplate issuppliedtoenable pipework to be pre-installed prior to siting the boiler.
ElectromaxSolarisafullypackagedunitandcomescompletewitha9kWelectricboiler,Duplexstainlesssteelsolarthermalhotwatercylinder(availablein185,220or250litrecapacities)withaspeciallydesignedsolarcoilformaximumheatinputand efficiency, a pre-plumbed factory-fitted circulating pump, service isolation valve, central heating and solar domestic hot water controls.
Both the solar hydraulic pump and solar controller are fully integrated into the ElectromaxSolar resulting inaquickandneater installation ready for connectionto solar collectors. They are operated by a clear, multifunctional and easy to use controlpanelwithanintegratedLCDdisplay.
To complete the solar thermal installation, a choice of in-roof and on-roof flat plate solar collector kits are available. Every kit is supplied with primary solar system fluid, 24litresolarratedexpansionvesselandconnectingpipekit.
Supportedbyournationalserviceandtechnicalsupportnetwork,ElectromaxSolarfeatures a 10 year on-site parts and labour guarantee on its stainless steel cylinder and two years on the boiler and controls. A specification and design service isavailablethroughourSpecificationAdviceTeamonTel:01603420220.
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
Electromax solar
1110
2
5
10
12
14
15
17
20
22
21
19
18
16
13
11
98
4
6
7
3
1
Discharge pipes
Auto air vent
Pressurereliefvalve
Flowmeter
Temperatureand pressurerelief valve
Pump
Flow
Flow
Cylinder
Electric boiler
Cold watercombination
valve (supplied)
Coldmainsfeed
To hotoutlets
Return
Return
Automaticbypass valve
Solar manualair vent
Primaryexpansion
vessel
Connectionto radiators
or underfloorsystem
Connectionsto collector
Electromax Solar installation
WhencombinedwithasuitableElectromaxSolarcollectorpanelkittheElectromaxSolarcomprisesalltheprinciplecomponentstoprovide:
• Anefficientsolar,unvented,storage,waterheatingsystem.
• Back-upelectricwaterheating.
• Anelectricallyheatedwetcentralheatingsystem.
IntheUKawelldesignedsolarsystemhasthepotentialtodeliverupto60%ofadwelling’shotwaterrequirementfromsolarenergy,howeverthisenergyisnotreceiveduniformlythroughouttheyear(70%oftheUKannualradiationisreceivedovertheperiodApriltoSeptemberand 25%isreceivedinthemonthsofJuneandJuly).
Solar unvented storage water heating system The solar primary circuit includes a circulating pump, a flow meter, an expansion relief valve, a manual air vent and two high temperature checkvalves,allfactory-fitted.Solarcollectors,solarexpansionvesselsand heat transfer fluid are supplied as separate accessory kits.
Temperature control of the solar circuit is provided by a microprocessor-based differential temperature controller housed in the main Electromax Solarcontrolpanel.Over-temperatureprotectionisprovidedbyamanually-resettable double-pole cut-out.
The domestic hot water system includes a factory-fitted temperature andpressurereliefvalveandexpansionvessel.Acoldwater combination valve which comprises a pressure reducing valve, and expansion relief valve, a check valve, and a strainer, is supplied loose.
TheDuplexstainlesssteelcylindergivesmaximumstrengthandlonglife, offering superior resistance to corrosion especially in aggressive water areas compared to copper, glass-lined steel and some lower grades of stainless steel.
Electrically heated wet central heating system TheElectromaxSolarhasawet,sealed,centralheatingprimarycircuitsuitable for connection to radiators or underfloor manifolds depending on the model purchased.
The circuit includes a 9kW electric flow boiler, circulating pump, an expansion vessel, an expansion relief valve, an automatic air vent and an automatic bypass valve, all factory-fitted.
Keycomponents
1 Primarysystemexpansionvessel.2 Fasciapanel.3 Userinterfacepanel.4 Solartemperature/pressurereliefvalve.5 Boilerelectroniccontrol(undercover).6 Solarflowmeterincludingfillinganddrain.7 Domestichotwatercylinder(insulated).8 Solarmanualairvent.9 Temperature/pressurereliefvalve.10 Boost immersion heater.11 Primarysystempressurereliefvalve.12 Off-peakimmersionheater.13 Tundish.14 Electric boiler.15 Fillingloop.16 Solarflow.17 Hotwateroutletconnection.18 Solarreturn.19 Dischargepipe.20 Cold water inlet connection.21 Primaryflowisolatingvalve.22 Primaryreturnisolatingvalve.
TheElectromaxSolarhasahostoffeatureswhichbenefitdevelopers,builders,installers, landlords and end users to make it a desirable alternative where gas is not available or not the preferred option.
• TheElectromaxSolarunventedhotwatercylinder,manufacturedfromhighgradeDuplexstainlesssteel,isinsulatedwithpolyurethanefoam.
• Theprimarydomestichotwaterheatsourceissolarenergyviaasolarcoil heat exchanger.
• CylindersizesandsolarvolumeshavebeenspecificallydesignedtomeetSAP*requirementsfor1,2and3bedroomproperties.
• Two3kWimmersionheatersareincluded;onepositionedlowerinthetanktoheatthe non-solar dedicated volume of the cylinder for periods of low solar gain and an upper immersion heater to provide a one-hour boost.
• Controlofthesolarcircuitismadebyafactory-fittedpre-setdifferentialtemperaturecontroller which monitors and regulates the system to give maximum solar benefit without the need for user interface.
• Thesolarhydrauliccontrolsarefactory-fittedforeaseofinstallation.
• Avarietyofsolarcollectorkitsareavailabletosuitdifferentroofoptions.
• ModelsareavailabletosuitbothSouthfacingandEast/Westfacingproperties.
• Thecentralheatingprimarycircuitisawetsealedsystemsuitableforradiators. Underfloorheatingmodelsarealsoavailable.
• Thecentralheatingheatsourceisa9kWelectricflowtypeboiler,factory-fitted.
• Temperaturecontrolofthecentralheatingsystemisprovidedbyaprogrammableroom thermostat which can accommodate a wide range of off-peak electricity tariffs.
• Noflueandnofueltanksallowflexibleinstallation.
• Norequirementforanannualgassafetycertificate.
* Standard Assessment Procedure.
Front control panel:
• Hotwater–On/Off.
• Onehourboost–On/Off.
• Centralheating–On/Off.
• Electricboiler–Supply/Demand/Heat/Fault.
• Centralheating–Pressure(Bar).
• Solarpaneltemperature–Min/Max/Actual(ºC).
• Cylindertemperature–Min/Max/Actual(ºC).
• Solarpump–On/Off.
• Solarsystem–Fault.
• Solarsystem–Pressure(Bar).
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
1312
Legislation
Energy consumption of dwellings, in particular space and water heating have been identified as key areas to help meetEuropeanandUKgovernmentcarbonreductiontargets.
Newregulationshavebeenintroduced(CodeforSustainableHomes(CfSH),andexistingregulationstightened(BuildingRegulationPartL,StandardAssessmentProcedure(SAP))toensurethatboth NewBuildpropertiesandupgradesofexistingdwellingsmeetthelatestenergyefficiencyrequirements,therefore driving down emissions and reducing the country’scarbonfootprint.
Installation of a solar water heater, whether as part of a new build development or as an upgrade to an existing property,playsakeypartinincreasingaproperty’senergyefficiencyandtheElectromaxSolarhasbeendesignedwithCfSH,SAPandPartLinmind.
TheElectromaxSolartotalcylindercapacity(Vt)ismadeoftwoparts:Dedicatedsolarvolume(Vs)andauxiliaryvolume(Vb)whereVt=Vs+Vb.
Thededicatedsolarvolume(Vs)canonlybeheatedbysolar energy. The volume has been calculated to ensure therequirementsofBuildingRegulationPartLandSAParemet(Vs=80%VdwhereVd=TFAorVs=25Litrespermetresquaredofsolarcollector)ifinstalledcorrectly.
The auxiliary volume has been calculated to ensure that on a cold day with low solar gain there will be sufficient hotwaterforthedwellingasrequiredby BS6700.
SpecificationCapacitiesCylinder:185,220and250litres.
RatingsBoiler:9kW@240V(8.3kW@230V). ImmersionHeaters:2x3kW@240V (2x2.8kW@230V).
ElementsBoiler: Long life, low watts density, copper elements in a copper heat exchanger. Cylinder:LonglifeSuperloy825alloysheathedelements incorporated into an easily-removable heater plate should replacement be necessary.
Outer casingWhite stove enamelled corrosion resistant steel. ControlPanelfascia–ABSwhite. Cover–ABStintedgrey.
Thermal insulationBoiler:Armaflex–closedcellinsulation. Dust,fibreandCFC/HCFCfree(ODPZero). Cylinder:CFC/HCFCFree(ODPZero)expandedpolyurethane.GWP3.1(GlobalWarmingPotential). HTArmaflexonsolarpipes.
ThermostatStandardBoiler:Electronicdualcontrol, user-adjustablefrom65ºCto80ºC. Underfloorboiler:Electronicdualcontrol, user-adjustablefrom30ºCto60ºC. Cylinder:Elementthermostatadjustablefrom 10ºCto70ºC.
Water containerBoiler: Copper. Cylinder:Duplexstainlesssteelwithexternalexpansion vessel.
Safety featuresBoiler:2ampfusedpumpsupply,dualcontrolcircuits,dual switching of the elements, self-checking circuitry and fault indication. Resettable thermal cut-out. Cylinder:Manually-resettablecut-outonheatingelementoperatesat85ºC.
Primary circuitPressurereliefvalvefactorysetto3.5bar. Cylinder fitted with temperature and pressure relief valve,factory-settooperateat10bar/90ºC.
ApprovalsCE marked. ManufacturedintheUKinaBSENISO9001:2008, ISO14001:2004andBSOHSAS18001:2007registeredfactory.
Primary system pumpGrundfosUPS15-50(withintegralautomaticairvent).
Solar system pumpGrundfosSolarUPS15-65.
Expansion vesselsPrimarySystem:12litre3bar,factory-fitted. PotableWater:18litre3.5bar,factory-fitted. Solar:24litre,1.5bar,suppliedloose.
InstallationTheElectromaxSolarmustbeinstalledbyacompetent installer in accordance with Local Building Regulations.Pleasecontactyourlocalbuildingregulations officer for further advice.
LocationMustbefloor-mounted.Afixingtemplateisprovidedto assist. The location should consider access for service and maintenance and routes for discharge.
Water supplyCanbeconnectedtoamaximumflowrateof55litresper minute and a maximum supply pressure of 16 bar (reducedto3.5).Itisrecommendedthatflowratesarenolowerthan20litresperminuteandpressureisnolowerthan1.5bar.
Domestic hot water connectionsCold water inlet and hot water outlet connections are madeby22mmcompressionfittingatthebottomrighthandsideoftheElectromaxSolar.Pipeentry canbefromtherighthandside(viaknock-outpanels)or directly below.
Solar connectionsSolarflowandsolarreturnconnectionsaremadeby22mmcompressionfittingatthetopleftsideoftheElectromaxSolar.
Central heating connectionsCentral heating flow and return connections are made by22mmcompressionfittingatthebottomlefthandsideoftheElectromaxSolar.Pipeentrycanbefromthelefthandside(viaknockoutpanels)ordirectlybelow.
DischargeDischargepipeworkfromthefactory-fittedtemperature and pressure relief valve should be installed in accordance with local building regulations. Dischargepipeworkisalsorequiredfromthecoldwatercombinationvalve.Dischargepipeworkisalsorequiredfromthesolarpressurereducingvalve.
ElectricalDesignedforconnectiontoanoff-peakelectricitysupply.Pleasecontactyourelectricitysupplierfordetails of available tariffs. The electric flow boiler must be permanently connected to the electricity supply via a double-pole isolating switch with a minimum breakingcapacityof45amps.Thecontrolpanelandimmersion heaters must be permanently connected to the electricity supply via a double-pole isolating switch withaminimumbreakingcapacityof13amps.
External componentsSolarcollectors–arangeofsolarcollectorkitsareavailable to suit different property types please see page14forfurtherdetails.
Solarexpansionvessel–thesolarexpansionvesseliswall-mounted(bracketandfixingssupplied),itmustbeplumbed into the solar return pipework between the ElectromaxSolarandcollector(s)andshouldbesitedasclosetotheElectromaxSolaraspossible.
Solardivertervalve(East/Westarraysonly)–theSolardiverter valve is plumbed into the solar return pipework between the expansion vessel and collectors. Connectionismadeby22mmcompressionfittings.
Coldwatercombinationvalve–thecoldwatercombination valve is plumbed into the mains water supplybeforetheElectromaxSolar.Connectionismadeby22mmcompressionfittings.
Programmableroomthermostat–theprogrammableroom thermostat is wall mounted and should be wired totheElectromaxSolar.
GuaranteeTheElectromaxSolarDuplexstainlesssteelvesselcarries a full 10 year guarantee against faulty manufacture or materials provided that:
• Ithasbeencorrectlyinstalledaspertheinstructions contained in the instruction manual andallrelevantCodesofPracticeandRegulationsin force at the time of installation.
• Ithasnotbeenmodifiedinanyway,otherthanbyHeatraeSadiaHeating.
• Ithasnotbeenfrostdamaged.
• Ithasonlybeenusedforthestorageofpotablewater.
• Ithasnotbeentamperedwithorbeensubjectedto misuse or neglect.
• IthasbeeninstalledintheUK.
• Within60daysofinstallationtheusercompletesand returns the certificate supplied along with the proof of purchase to register the product.
Allothercomponentsareguaranteedforaperiodoftwo years from the date of purchase provided that:
• Ithasbeencorrectlyinstalledaspertheinstructions contained in the instruction manual andallrelevantCodesofPracticeandRegulationsin force at the time of installation.
• Ithasnotbeenmodifiedinanyway,otherthanbyHeatraeSadiaHeating.
• Ithasnotbeenfrostdamaged.
• Ithasnotbeentamperedwithorbeensubjectedto misuse or neglect.
• IthasbeeninstalledintheUK.
• Within60daysofinstallationtheusercompletesand returns the certificate supplied along with the proof of purchase to register the product.
Evidence of purchase and date of supply must be submitted. These guarantees do not affect your statutory rights.
Fullspecifications
Dimensions
Capacity Radiator / Underfoor (litre)
185
220
250
Dimensionsandordering
Cylinder performance
Capacity Radiator / Underfoor
(litre)
185
220
250
Auxiliary volume
(litre)
120
145
175
Heat-up auxiliary volume
(mins)
126
152
178
Boost
(mins)
60
60
60
Re-heat
(mins)
88
106
125
Standing heat loss
(kWhr/24hr)
1.76
1.73
1.70
Ordering guide
Model
ElectromaxSolar185Radiator
ElectromaxSolar220Radiator
ElectromaxSolar250Radiator
ElectromaxSolar185RadiatorEastWestArray
ElectromaxSolar220RadiatorEastWestArray
ElectromaxSolar250RadiatorEastWestArray
ElectromaxSolar185Underfloor
ElectromaxSolar220Underfloor
ElectromaxSolar250Underfloor
ElectromaxSolar185UnderfloorEastWestArray
ElectromaxSolar220UnderfloorEastWestArray
ElectromaxSolar250UnderfloorEastWestArray
Product code
95:022:212
95:022:214
95:022:215
95:022:216
95:022:217
95:022:218
95:022:312
95:022:314
95:022:315
95:022:316
95:022:317
95:022:318
A
(mm)
1580
1800
1990
B
(mm)
550
550
550
C
(mm)
600
600
600
B C
A
300 minimumclearance overtop panel
50 min. clearance
Heat-up(auxiliary)–Timetakentoheatauxiliaryvolumefrom15ºCto60ºCusinglower3kWimmersion heater.
Boost–Timetakentoheatboostvolume(57litres)from15ºCto60ºCusingupper3kWimmersion heater.
Re-heat–Timetakentoreheatauxiliaryvolumeto60ºCusinglower3kWimmersionheaterfollowing draw off of 70% auxiliary volume.
Heat-up(solar)–Solarheatuptimewillvarydependingonsolarradiation,sunshinehours,collectorpaneltype,sizeandorientation.
Standingheatloss–EnergyinkW/hrrequiredtokeepwaterat65ºCover24hourperiod(ambienttemperature20ºC).
Weight Empty Full (kg) (kg)
94 279
105.5 325.5
112 362
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
Property Type
1BedFlat
2BedFlat/House
3BedHouse
Occupants
1-2
2-3
3-4
Electromax
185
220
250
Panel
1
1
2
Specification
Model
Radiator
ElectromaxSolar185
ElectromaxSolar220
ElectromaxSolar250
Radiator – East West Array
ElectromaxSolar185
ElectromaxSolar220
ElectromaxSolar250
Underfoor
ElectromaxSolar185
ElectromaxSolar220
ElectromaxSolar250
Underfoor – East West Array
ElectromaxSolar185
ElectromaxSolar220
ElectromaxSolar250
Rating @ 240V (kW)
Boiler Cylinder
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
9 2x3
Capacity (litre)
Boiler Cylinder
1.3 185
1.3 220
1.3 250
1.3 185
1.3 220
1.3 250
1.3 185
1.3 220
1.3 250
1.3 185
1.3 220
1.3 250
Note:TocomplywithSAP,theElectromaxSolarmusteither be installed in a property with a total floor space equaltoorlowerthanthevalueshowninthetableabove,orwithagrosscollectorareaequaltoorlowerthan the value shown in the table opposite.
The table below shows recommended Electromax Solarandcollectorinstallations:*
*This table is for guidance only. OurSpecificationAdviceHotlineshouldbecalledtodiscussdesignandrequirementsforspecificsites–Tel:01603420220.
Electromax (Vt)
185
220
250
Total Floor Area Max
52
69
77
Collector Max
2.6
3.0
3.2
Vb
120
145
170
Vs
65
75
80
Vd
80
93
99
1514
Ordering guide
Acompleterangeofhighquality,SolarKeymarkaccredited
panelstomeetindividualneeds,tastesandrequirements,
tosuitarangeofdifferentinstallations.On-roof,in-roofor
flat roof solar collectors can efficiently harness natural
energy from the sun.
• In-roofpanelsaresuitedtonewbuildapplicationsgivingahigherstandardoffinish.On-roof
panels are suited to existing properties as they are easier to install retrospectively.
• AnumberofmountingmethodsareavailabletosuitavarietyofrooftypesincludingFlatTile,
ProfiledTile,SlateandFlatRoof.
• SouthFacingarraysaresuitedtopropertieswitharoofthatfacesbetween30ºWestand40º
EastofSouth.
• East/Westarraysareavailableforpropertieswithroofsthatfaceover30ºWestand40ºEast
ofSouth.
• OnlyHeatraeSadiaElectromaxSolarcollectorkitsshouldbeusedwiththeElectromaxSolar.
• The solar collector kits include all necessary components to install the solar collectors and
completetheElectromaxSolarinstallationsincluding:
– Collectors
– Mountingrailsandbrackets
– Flashingkit(In-roofpanelsonly)
– Solarfluid
– Flexibletube
– Expansionvessel
– Thermostaticblendingvalve
Solar collectors
Solarcollectors–On-roof/In-roof
On-roof collector
Ideal for those who wish to install solar thermal domestic hot water to
a current building, without having to disturb too much of the existing
roof structure.
• Flatplatealuminiumframecollectorprovidescompleteweather
protection.
• Ultrasonicwelded(notsoldered)socanwithstandhightemperatures.
Specification
GrossArea 2.02m2
NetArea 1.84m2
Weight 39kg
Absorbercapacity 1.4litres
MaximumPressure 1.0MPa(10bar)
Absorption 95%±2%
Emission 5%±2%
Stagnationtemperature184ºC(max)
Glass Low-ironsolarglass,tempered,3.2mmthick.
Lighttransmittance 90.8%±2%
Insulation 40mmRockwoolwithblackfleece.
Heatconductivity0.045W/m2K
Grossdensity50-80kg/m3
Slate and Tile System includes: • 1,2or3panels,mountingbrackets.
A Frame System includes: • 1,2or3panels,AFrame.
In-roof collector
The perfect choice for all new build developments.
• Flatplatewoodenframecollectors.
• Ultrasonicwelded(notsoldered)socanwithstandhightemperatures.
Specification
GrossArea 2.52m2
NetArea 2.32m2
Weight 54kg
Absorbercapacity 1.7litres
MaximumPressure 1.0MPa(10bar)
Absorption 95%±2%
Emission 5%±2%
Stagnationtemperature210ºC(max)
Glass Low-ironsolarglass,tempered,3.2mmthick.
Lighttransmittance 90.8%±2%
Insulation 50mmRockwoolwithblackfleece.
Heatconductivity0.045W/m2K
Grossdensity50-80kg/m3
Slate in-roof System includes: • 1or2panels,mountingbrackets,flashingkit.
Tile in-roof System includes: • 1or2panels,mountingbrackets,flashingkit.
Performance
On-roof collector
Aperturearea
Absorberarea In-roof collector
Aperturearea
Absorberarea
Technical dataHeight
(mm)
1730
2058
On-roofcollector
In-roof collector
Width
(mm)
1170
1227
Depth
(mm)
83
105
Weight
(kg)
35
49
Maximum pressure
(bar)
10
10
Shutdown temperature
(ºC)
234
234
Area
(m2)
1.922
1.840
2.32
2.29
Zero loss co-efficient
(W/m2K)
0.756
0.790
0.780
0.791
Heat loss co-efficient
(W/m2K)
4.067
4.248
3.796
3.846
Slate and Tile on-roof system
1 panel
2panels
2panels–East/WestArray
3panels–East/WestArray
A Frame system
1 panel
2panels
Slate in-roof system
1 panel
2panels
2panels–East/WestArray
3panels–East/WestArray
Tile in-roof system
1 panel
2panels
2panels–East/WestArray
3panels–East/WestArray
Fittings
MultifitSolar6x22mmhightemperaturepipecompression–male
MultifitSolar6x22mmhightemperaturepipecompression–female
MultifitSolar6x22mmhightemperaturepipecompression–tee
MultifitSolar30mflexiblestainlesssteelpipekit
Solar fuid
MultifitSolarfluidtypeLS20Ltr(Pink)
MultifitSolarfluidtypeL20Ltr(Blue)
MultifitSolarelectricfluidfillingpump
MultifitSolarelectrichandfillingpump
Miscellaneous
MultifitSolar13msolarsensorwire
MultifitSolarrefractometerantifreezetestkit
Roof tile
Solarsensorwirejunctionbox
Product code
95:970:517
95:970:518
95:970:519
95:970:520
95:970:521
95:970:522
95:970:523
95:970:524
95:970:527
95:970:528
95:970:525
95:970:526
95:970:529
95:970:530
51:227:62
51:227:63
51:227:64
51:222:38
51:302:25
51:195:49
51:302:34
51:227:61
51:222:37
51:195:59
95:970:540
95:970:539
Specification Advice Hotline: 01603 420220 Email: specifier@heatraesadia.com
Accessories ordering guide
ContactSpecification Advice Hotline T:01603420220F:01603420229 E:specifier@heatraesadia.com
After Sales Service T:08448711535F:08448711528 E:heatraesadiaservice@heateam.co.uk
Web www.heatraesadia.com
HeatraeSadiaHeatingHurricaneWayNorwichNorfolkNR66EA
HeatraeSadiaHeatingmayintroducemodificationstotheirproductsfromtimetotime.Consequently,thedetailsgiveninthisbrochurearesubjecttoalterationwithoutnotice.
95900825Issue8©HeatraeSadiaHeating2011
heateamisHeatraeSadia’sveryownservicedivision.With us on your side, you can be sure that your customers are in the very best hands. Totally committedtoqualityandsafety,heateamisopen 7daysaweek,for363daysayear,andoffers:
• Dedicated Trade Advice Line–ourhelpfulandqualifiedspecialistsarealwaysonhandtohelpyouwitheventhemostcomplextechnicalquery.
• Installer Priority Call-Outs–our280strongteamof specifically trained expert heating engineers coverstheUK,nooneisbetterqualifiedtolookafterHeatraeSadia’sproductsfortheduration of the guarantee.
• Fully Stocked Vans–anationwidefleetofvans,fullystockedwithspareparts–meaningwecanrepairourappliancesonthefirstvisitin95%ofcall-outs.
• Exclusive Service Plans–heateamalsoofferHeatraeSadia’scustomersarangeofexclusiveannual service plans.
OpeningTimes:Monday-Friday8am-6pm,weekendsandBankHolidays*8.30am-2pm. *excludingChristmasDayandNewYear’sDay.
Simplycall0844 8711535 or visit our website at www.heateam.co.uk
PN95900825B
JN308360
Brochures for all of our products are
availablefreeofcharge.Pleasecallour
literaturehotlineon01603420127.
MEGAFLO ECO
Megafloecocylinderrange
DOMESTIC HEATING AND HOT WATER
Aerheat Amptec ElectricSolar Electromax ElectromaxSolar ImmersionHeaters MegalifeHE MegalifeSolar MultipointInstantaneous Showers
COMMERCIAL HOT WATER
B3M/C3M Express FBM Handy HandyDri/HairDrier Hotflo Multipoint MultipointSS Streamline UTC99
DRINKING WATER
SuperChill Supreme
Recommended