Suparule Cable Height Meter:
A guide
Jan 2012
7/28/2019 CHM Power Point Presentation
2/25
Key Features:Safest - no contact with conductors/wireSimple - One button- one man operationEasy to use - stand underneath, press the button, andread the measurement
Fast - measurements in secondsAccurate - less than 0.5% error in reading
Suparule Cable Height MetersCable Height Meteran ultrasonic device to check wire clearance to ground and
spacing of overhead conductors.
7/28/2019 CHM Power Point Presentation
3/25
Why was the CHM developed?
Low wires are a public safety problem
Many reported accidents with both electrical and telecomwires
Existing measuring methods were not considered safeenough for operators
7/28/2019 CHM Power Point Presentation
4/25
Competitive Instruments
Laser type surveying equipment. (Very expensive, and notapplication specific)
Fibre-glass hot sticks (frequently breaks, conveyselectricity if dirty/wet)
Optical device (inaccurate, cannot differentiate betweenconductors)
No real competitive instrument to the CHM
7/28/2019 CHM Power Point Presentation
5/25
Ultrasound Measurement From the cone of instrument, the transducer sends out a burst of sound
The sound bounces off the cable, and need to be received in cone, as
transducer is at the same time transmitter & receiver.
The CHM clocks the amount of time taken
Calculates distance, based on speed of sound. Adjusts for air temperature.
The microcontroller calculates the distance in either imperial or metric
Instrument Time Echoes from wires
7/28/2019 CHM Power Point Presentation
6/25
How to use of Cable Height Meter
CHM Operation
1.Select: M (metric) orI (imperial) at the back2.Set the CAL mode switch to the WIRE
position.
3.Press the ON key to power4.Stand directly underneath the conductors(s)
to be measured.
5. Press the MEASURE Key to takemeasurement. Press the READ key todisplay each of the stored wire height
differences (Stored Measurements).
7/28/2019 CHM Power Point Presentation
7/25
Cable height meter: CAL (Calibration) Mode The CAL mode switch allows the user to periodically check the unit,
to ensure that it is still operating within specification.
For cable height measurement, this switch should be in the WIREposition.
When the switch is put to the WALL (CAL) position horizontalmeasurements to large objects, e.g. walls, can be taken.
When the unit is first used, a horizontal reading to an object, e.g. wall,from a fixed position should be taken. The reading should berecorded, together with the date. Whenever the unit is to be checkedfor accuracy, a reading should be taken from the same point, noting
the result and date. If the reading is outside of specification, the unitshould be returned to Suparule. Date
Readings
7/28/2019 CHM Power Point Presentation
8/25
Range Specification of the CHM 190-300-600
measures up to 15m (50ft)
7/28/2019 CHM Power Point Presentation
9/25
Range Specification of the CHM 300E-600E
measures up to 23m (75Ft)
7/28/2019 CHM Power Point Presentation
10/25
Cable height meters: Model choiceCHM models 300 300E 600 600E
Range (25mm cable
min) 3 15m(10-50ft) 3 23m(10-75ft) 3 15m(10-50ft) 3 23m(10-75ft)Range (12mm cablemin) 3 15m(10-50ft) 3 15m(10-50ft) 3 15m(10-50ft) 3 15m(10-50ft)Range (5.5mm cable
min) 3 12m(10-40ft) 3 12m(10-40ft)Range (2.5mm cable
min) 3 10m(10-33ft) 3 10m(10-33ft)No. of wires
measured 3 3 6 6
7/28/2019 CHM Power Point Presentation
11/25
Just simply stand under the O/H line, center yourself under the
conductors and press the button.
7/28/2019 CHM Power Point Presentation
12/25
Reading #1 gives the height to the lowest conductor
7/28/2019 CHM Power Point Presentation
13/25
Reading #2 gives the distance between 1st and 2nd wire
7/28/2019 CHM Power Point Presentation
14/25
Reading #3 gives the distance between 2nd and 3rd wire
7/28/2019 CHM Power Point Presentation
15/25
Reading #4 gives the distance between 3rd and 4th wire
7/28/2019 CHM Power Point Presentation
16/25
The memory stores the measurements so that you can scroll
through them in order to record them on paper etc.
7/28/2019 CHM Power Point Presentation
17/25
By pressing button once, readings of up to 6 conductors aretaken provided the wires are all within the ultrasonic beam
7/28/2019 CHM Power Point Presentation
18/25
CHM & Ultrasonic beam Push Measure button once, provided wires are within
the ultrasonic beam.
If not, take a number of readings underneath each ofthe wire.
Make sure the cone is perpendicular
to overhead wire, as otherwise
reflection will not be received
in cone.
7/28/2019 CHM Power Point Presentation
19/25
CHM Accuracy : Error typically less than 0.5% +/-2digits
If the actual distance being measured is 5m, tolerance of +/-0.5%, the CHM will give a reading between 4.975m and 5.025m
The Number of digits specification is an extra tolerance on thedisplay reading. 2 digits = 10mm. The +2d specificationtherefore means that a further +/-10mm can be added to thedisplay reading, i.e. 4.965m and 5.035m.
Accuracy is met when CHM is regularly calibrated. Bestpractice require a 12 month calibration.
7/28/2019 CHM Power Point Presentation
20/25
CHM Battery
Battery Life 50,000 measurements
Battery used: 9V, PP3, non-rechargeable, Alkaline, Long-life (>600mAH)
The cable height meters automatically switch off after3mn if no buttons are pressed to save battery.
When battery is low, a low battery warning symbol popup on screen: Need to change the battery.
7/28/2019 CHM Power Point Presentation
21/25
Do & Dont with CHMDos:
Position the unit on the ground, directlyunderneath the conductor(s) to bemeasured.
Align the unit in the direction of the
conductor, with the cone pointing towardsthe conductor(s).
The ultrasonic waves need to be sent andreceived in the cone, so alignment isimportant.
Keep the unit dry; if it does get wet, leave itupside down in a warm area
The unit will work in a humid environment;however, if water gets into the electronics,long-term damage can occur.
Donts:
Avoid clutter.
Too many branches/leaves couldconfuse the unit, as the ultrasonic waveswill bounce back from any obstacles.
Avoid water.
It can damage the electronics
Avoid sudden changes of temperature.
The Cable Height Meter takes intoaccount temperature to measure thespeed of sound travelling in air. If there
are sudden temperature changes, i.e.from a warm car in winter to cold icyground, leave the unit to adjust for a fewminutes.
7/28/2019 CHM Power Point Presentation
22/25
Suparule Cable Height Meters :Get the most out of CHMs
1. Let temperature settle, otherwise incorrect reading is displayed.
2. Press measure button until reading is stable. Unit needs to get aclear/clean echo back, to calculate correct distance.
3. Make sure echo gets back into cone, as otherwise, unit will notdisplay reading. May need to tilt unit to get a reading if overheadwires are sloped.
4. CHM is not waterproof, so keep unit dry as much as possible. Ifwet, leave it in a warm place upside down, until dry.
5. Regular calibration a must to get best accuracy
7/28/2019 CHM Power Point Presentation
23/25
Who uses the CHM?
Planners
Safety Officers
Line Managers
Linesmen / Installers
Contractors
Haulage companies
Regulatory Inspectors
7/28/2019 CHM Power Point Presentation
24/25
Warranty & Repair
The CHM is covered by a 24 month warranty on all partsand labour
Any defective instrument will be replaced free of charge
during this period Damaged or broken instruments will be repaired and
charged at cost
Each instrument is pre-set, and calibrated at Suparule
Service contract available, please contact your
distributor/suparule.
7/28/2019 CHM Power Point Presentation
25/25
Suparule Cable Height Meters
No better instrument for wire distance measurement
Your key partner to safety
Order NOW