LIGHT SWITCH, FOUR WAY DEVICE, 20 AMP, 120/277 VOLT, FLUSH
AutoCAD SHX Text
MOTOR RATED SWITCH, FLUSH MOUNT 50" AFF, TO TOP OF BOX
AutoCAD SHX Text
LIGHT SWITCH, THREE WAY DEVICE, 20 AMP, 120/277 VOLT, FLUSH
AutoCAD SHX Text
EMERGENCY LIGHTING UNIT. CIRCUIT ON LINE SIDE OF SWITCH FOR
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
M
AutoCAD SHX Text
4
AutoCAD SHX Text
48" AFF TO TOP OF BOX.
AutoCAD SHX Text
3
AutoCAD SHX Text
WALL OUTLET WITH LIGHTING FIXTURE, TYPE AS INDICATED
AutoCAD SHX Text
CEILING OUTLET WITH FLUORESCENT FIXTURE, TYPE AS INDICATED
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
G
AutoCAD SHX Text
T3
AutoCAD SHX Text
EXIT/FLOODLIGHT COMBO UNIT
AutoCAD SHX Text
PANEL BOARD, EXISTING
AutoCAD SHX Text
PANEL BOARD, NEW
AutoCAD SHX Text
J
AutoCAD SHX Text
NL SUBSCRIPT DENOTES NIGHT LIGHT - CIRCUIT SO THAT THE OUTER
AutoCAD SHX Text
FOR LIGHTS IN SAME AREA, OR WITH LIKE FIXTURES ON SEPARATE CIRCUIT.
AutoCAD SHX Text
TWO LAMPS OR FIXTURE OPERATES 24 HOURS A DAY. CIRCUIT ON LINE SIDE OF SWITCH
AutoCAD SHX Text
TYPE AS INDICATED.
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
A AMP AMP AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR AP ALARM PANEL ALARM PANEL AHU AIR HANDLING UNIT AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAGE AMERICAN WIRE GAGE BC BATTERY CHARGER BATTERY CHARGER C CONDUIT CONDUIT CB CIRCUIT BREAKER CIRCUIT BREAKER CKT CIRCUIT CIRCUIT CP CONTROL PANEL CONTROL PANEL CR CONTROL RELAY CONTROL RELAY CTB CABLE TAP BOX CABLE TAP BOX CU COPPER COPPER DETD DUAL ELEMENT TIME DELAY DUAL ELEMENT TIME DELAY DPS DOOR POSITION SWITCH DOOR POSITION SWITCH EX EXISTING TO REMAIN EXISTING TO REMAIN ECB ENCLOSED CIRCUIT BREAKER ENCLOSED CIRCUIT BREAKER EF EXHAUST FAN EXHAUST FAN EVA ELECTRIC VALVE ACTUATOR ELECTRIC VALVE ACTUATOR EM EMERGENCY EMERGENCY ER EXISTING TO BE RELOCATED EXISTING TO BE RELOCATED ETR EXISTING TO REMAIN EXISTING TO REMAIN EWC ELECTRIC WATER COOLER ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER ELECTRIC WATER HEATER GFI GROUND FAULT INTERRUPTER GROUND FAULT INTERRUPTER GND/G GROUND GROUND HP HEAT PUMP HEAT PUMP HMI HUMAN MACHINE INTERFACE HUMAN MACHINE INTERFACE LA LIGHTING ARRESTOR LIGHTING ARRESTOR IG ISOLATED GROUND ISOLATED GROUND JB JUNCTION BOX JUNCTION BOX KW KILOWATT KILOWATT KVA KILOVOLT AMPERE KILOVOLT AMPERE MDP MAIN DISTRIBUTION PANEL MAIN DISTRIBUTION PANEL MLO MAIN LUG ONLY MAIN LUG ONLY NEC NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUF. ASSOC NATIONAL ELECTRICAL MANUF. ASSOC NL NIGHT LIGHT NIGHT LIGHT OL OVERLOAD OVERLOAD PB PUSHBUTTON MOMENTARY CONTACT SWITCH PUSHBUTTON MOMENTARY CONTACT SWITCH PS POWER SUPPLY POWER SUPPLY RAIL REMOTE ALARM INDICATOR LIGHT REMOTE ALARM INDICATOR LIGHT RGS RIGID GALVANIZED STEEL CONDUIT RIGID GALVANIZED STEEL CONDUIT RCH REHEAT COIL REHEAT COIL RTU ROOFTOP UNIT ROOFTOP UNIT SP SURGE PROTECTOR SURGE PROTECTOR TB TERMINAL BLOCK TERMINAL BLOCK TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR TRANSIENT VOLTAGE SURGE SUPPRESSOR UH UNIT HEATER UNIT HEATER UNO UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UNINTERRUPTIBLE POWER SUPPLY V VOLT VOLT WG WIRE GUARD WIRE GUARD WP WEATHERPROOF WEATHERPROOF XFMR TRANSFORMERTRANSFORMER
AutoCAD SHX Text
DEVICE WIRING POINT/TERMINAL NORMALLY OPEN SINGLE CIRCUIT MOMENTARY PUSHBUTTON SWITCH NORMALLY CLOSED SINGLE CIRCUIT MOMENTARY PUSHBUTTON SWITCH SINGLE POLE NORMALLY OPEN TOGGLE SWITCH SINGLE POLE NORMALLY CLOSED TOGGLE SWITCH RELAY OPERATING COIL NORMALLY OPEN RELAY CONTACT NORMALLY CLOSED RELAY CONTACT NORMALLY OPEN/NORMALLY CLOSED RELAY CONTACT TRANSFORMER FUSE, NON RESETTABLE THERMAL OVERLOAD CIRCUIT INTERRUPTER, 1-POLE MANUAL RESET CIRCUIT BREAKER GROUND CONNECTIONS. LEFT=NOT CONNECTED. RIGHT=CONNECTED MOTOR/PUMP SCHEDULE TAG ELECTRICAL METER
AutoCAD SHX Text
M
AutoCAD SHX Text
X
AutoCAD SHX Text
P
AutoCAD SHX Text
DATA WALL OUTLET
AutoCAD SHX Text
TELEPHONE WALL OUTLET
AutoCAD SHX Text
A
AutoCAD SHX Text
POWER POLE, CEILING TO SYSTEM FURNITURE
AutoCAD SHX Text
P
AutoCAD SHX Text
DUPLEX RECEPTACLE WITH MOUNTING HEIGHT.
AutoCAD SHX Text
48
AutoCAD SHX Text
COMBINATION TELEPHONE/DATA OUTLET
AutoCAD SHX Text
MOUNT G INDICATES GFCI PROTECTED, WP INDICATES WEATHER
RECESSEED COMPACT FLUORESCENT DOWNLIGHT, TYPE AS INDICATED
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
NL
AutoCAD SHX Text
NL
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
E, NE
AutoCAD SHX Text
E, NE
AutoCAD SHX Text
OCCUPANCY SENSOR, CEILING MOUNTED. SWITCH ALL
AutoCAD SHX Text
OS
AutoCAD SHX Text
PILOT LIGHT.
AutoCAD SHX Text
AND NIGHT LIGHT, E AND NL, ON SAME FIXTURE.
AutoCAD SHX Text
LIGHTS IN ASSOCIATED AREA. PROVIDE POWER PACK.
AutoCAD SHX Text
FOR LIGHTS IN SAME AREA.
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
S
AutoCAD SHX Text
DOOR ACCESS SYSTEM CARD READER
AutoCAD SHX Text
CR
AutoCAD SHX Text
V
AutoCAD SHX Text
T
AutoCAD SHX Text
FURNITURE OR CEILING MTD TELEVISION. HEIGHT AS INDICATED.
AutoCAD SHX Text
DOOR OPERATOR PUSH BUTTON
AutoCAD SHX Text
DO
AutoCAD SHX Text
DOOR ACCESS CONTROL SYSTEM PANEL
AutoCAD SHX Text
DACP
AutoCAD SHX Text
AUDIO WALL OUTLET
AutoCAD SHX Text
A
AutoCAD SHX Text
VIA CABLING TO OWNERS EXISTING SYSTEM.
07/20/20
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
GENERAL ELECTRICAL NOTES
AutoCAD SHX Text
1. ALL NOTES, SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT. ALL NOTES, SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT. 2. COMPLY WITH 2014 NEC AND THE MOST RECENT VERSION OF THE VIRGINIA COMPLY WITH 2014 NEC AND THE MOST RECENT VERSION OF THE VIRGINIA COURTHOUSE FACILITY GUIDELINES. 3. CONTRACTORS SHOULD SCHEDULE A SITE VISIT TO FAMILIARIZE THEMSELVES WITH CONTRACTORS SHOULD SCHEDULE A SITE VISIT TO FAMILIARIZE THEMSELVES WITH CONDITIONS TO BE MET IN THE EXECUTION OF THE WORK UNDER THIS CONTRACT. 4. COORDINATE SERVICE REQUIREMENTS WITH LOCAL POWER COMPANY, TELEPHONE, DATA COORDINATE SERVICE REQUIREMENTS WITH LOCAL POWER COMPANY, TELEPHONE, DATA AND/OR CABLE PROVIDER. PROVIDE C.T. CABINET AND TRANSFORMER PAD AS REQUIRED PER POWER COMPANY SPECIFICATIONS. ANY FEES OR CHARGES BY THE POWER ANY FEES OR CHARGES BY THE POWER COMPANY SHALL BE PAID FOR BY THE OWNER. HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL CONCRETE PADS, CONDUIT, WIRING, ETC. REQUIRED BY THE UTILITY COMPANY FOR THE INSTALLATION OF THE NEW SERVICE DISCONNECT. 5. COORDINATE EXACT PANEL, SWITCHBOARD AND MCC LOCATIONS WITH PLUMBING AND COORDINATE EXACT PANEL, SWITCHBOARD AND MCC LOCATIONS WITH PLUMBING AND MECHANICAL DRAWINGS TO INSURE REQUIRED CLEARANCE ABOVE AND AROUND PANELS. 6. PROVIDE INCREASED CONDUCTOR SIZES FOR 120/208 BRANCH CIRCUITS AS FOLLOWS PROVIDE INCREASED CONDUCTOR SIZES FOR 120/208 BRANCH CIRCUITS AS FOLLOWS UNO: CIRCUIT BREAKER 0-100 FT. 100-200 FT. 200-300 FT. OVER 300 FT. 0-100 FT. 100-200 FT. 200-300 FT. OVER 300 FT. 100-200 FT. 200-300 FT. OVER 300 FT. 200-300 FT. OVER 300 FT. OVER 300 FT. SIZE LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH LENGTH 20 AMP 12 AWG 10 AWG 6 AWG 4 AWG 12 AWG 10 AWG 6 AWG 4 AWG 10 AWG 6 AWG 4 AWG 30 AMP 10 AWG 8 AWG 4 AWG 3 AWG 10 AWG 8 AWG 4 AWG 3 AWG 8 AWG 4 AWG 3 AWG 7. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULLWIRE. 8. ALL CONDUCTORS SHALL BE COPPER, TWHN OR THHN. ALL CONDUCTORS SHALL BE COPPER, TWHN OR THHN. 9. ALL BRANCH CIRCUIT WIRES TO BE SIZED AT LEAST #12 AWG THWN WITH #12 AWG ALL BRANCH CIRCUIT WIRES TO BE SIZED AT LEAST #12 AWG THWN WITH #12 AWG GROUND, IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED ON THE PLANS OR SCHEDULES. 10. ALL WIRING FOR THE INTERIOR AND EXTERIOR OF THE BUILDING IS TO BE CONCEALED ALL WIRING FOR THE INTERIOR AND EXTERIOR OF THE BUILDING IS TO BE CONCEALED WITHIN THE WALLS, CEILING, OR FLOOR SYSTEMS. THIS INCLUDES ELECTRICAL, CABLE TV, INTERNET, AND TELEPHONE. EXPOSED ELECTRICAL SERVICE TO THE BUILDING IS TO BE IN CONDUIT AND RUN VERTICALLY TO THE METER WITH HORIZONTAL RUNS. 11. ALL CONDUIT TO BE RUN CONCEALED IN FINISHED SPACES. PVC CONDUIT IS NOT ALL CONDUIT TO BE RUN CONCEALED IN FINISHED SPACES. PVC CONDUIT IS NOT PERMITTED IN AIR PLENUM OR EXPOSED INSIDE THE BUILDING. WHERE UNDERGROUND PVC CONDUITS ENTER THE BUILDING, CONCRETE ENCASEMENT OR METAL SHROUND SHALL BE USED TO PROTECT THE PVC FROM POSSIBLE DAMAGE. PROVIDE PROVIDE WEATHERPROOF SEALS ON ALL CONDUIT AND SLEEVE PENETRATIONS. 12. PROVIDE PUTTY PACKS TO MEET THE REQUIREMENTS OF 2009 INTERNATIONAL BUILDING PROVIDE PUTTY PACKS TO MEET THE REQUIREMENTS OF 2009 INTERNATIONAL BUILDING CODE SECTION 712 FOR MEMBRANE PENETRATIONS. 13. SHARED NEUTRALS ON RECEPTACLE BRANCH CIRCUITS ARE NOT ACCEPTABLE. SHARED NEUTRALS ON RECEPTACLE BRANCH CIRCUITS ARE NOT ACCEPTABLE. 14. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL TESTING THE ELECTRICAL ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL TESTING THE ELECTRICAL SYSTEM FOR: A. VOLTAGE AND TOTAL LOAD IN AMPS AND FOR INSULATION RESISTANCE IN OHMS ON VOLTAGE AND TOTAL LOAD IN AMPS AND FOR INSULATION RESISTANCE IN OHMS ON EACH PHASE FOR SERVICE ENTRANCE. B. VOLTAGE AND TOTAL LOAD IN AMPS FOR EACH METER CENTER AND LOAD CENTER VOLTAGE AND TOTAL LOAD IN AMPS FOR EACH METER CENTER AND LOAD CENTER INSTALLED. C. VOLTAGE AND TOTAL LOAD IN AMPS FOR EACH FEEDER CIRCUIT WITH #4 VOLTAGE AND TOTAL LOAD IN AMPS FOR EACH FEEDER CIRCUIT WITH #4 CONDUCTORS OR LARGER. 13. RECESSED DEVICES MAY BE ADJUSTED TO MATCH MASONRY COURSES IF APPLICABLE. RECESSED DEVICES MAY BE ADJUSTED TO MATCH MASONRY COURSES IF APPLICABLE. MOUNT ALL BOXES TRUE AND PLUMB. 14. COORDINATE WITH MECHANICAL CONTRACTOR ON EXACT LOCATION AND ELECTRICAL COORDINATE WITH MECHANICAL CONTRACTOR ON EXACT LOCATION AND ELECTRICAL CONNECTION REQUIREMENTS FOR HVAC EQUIPMENT. 15. ELECTRICAL REQUIREMENTS FOR HVAC EQUIPMENT ARE FOR HVAC EQUIPMENT ELECTRICAL REQUIREMENTS FOR HVAC EQUIPMENT ARE FOR HVAC EQUIPMENT SPECIFIED. IF SUBSTITUTE HVAC EQUIPMENT IS SUPPLIED, CONTRACTOR IS RESPONSIBLE FOR MODIFICATIONS IN AND/OR ADDITIONS TO ELECTRICAL REQUIREMENTS OF HVAC EQUIPMENT SUPPLIED. 16. ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF POWER ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF POWER WIRING TO ALL PLUMBING AND HVAC EQUIPMENT. ELECTRICAL SUBCONTRACTOR SHALL REVIEW ALL PLUMBING AND HVAC DRAWINGS TO DETERMINE LOCATIONS OF EQUIPMENT. 120 VOLT CONTROL WIRING AND CONDUIT SHALL BE BY THE ELECTRICAL SUBCONTRACTOR. ALL WIRING AND CONDUIT ASSOCIATED WITH LOW VOLTAGE MECHANICAL CONTROLS (LESS THAN 100 VOLTS) SHALL BE BY THE MECHANICAL SUBCONTRACTOR UNLESS WORKED OUT OTHERWISE BY THE INDIVIDUAL TRADES. MECHANICAL CONTROLS WIRING SHALL BE IN CONDUIT AND SHALL BE INSTALLED PER NATIONAL ELECTRIC CODE, UNIFORM STATEWIDE BUILDING CODE, AND MANDATES OF THE LOCAL BUILDING OFFICIALS. 17. LIGHT FIXTURES SHALL BE FURNISHED AND INSTALLED WITH LAMPS. LIGHT FIXTURES SHALL BE FURNISHED AND INSTALLED WITH LAMPS. A. BALLASTS SHALL BE ELECTRONIC TYPE OPERATING AT SUPERSONIC FREQUENCIES, BALLASTS SHALL BE ELECTRONIC TYPE OPERATING AT SUPERSONIC FREQUENCIES, WITH NO MORE THAN 20% HARMONIC DISTORTION AND WITH NO VISIBLE LAMP FLICKER. SLAVE/MASTER BALLASTS SHARED BY PAIRS OF FIXTURES MAY BE USED. B. ALL LIGHTING FIXTURES WITHIN THE UNITS SHALL BE ENERGY STAR RATED. ALL LIGHTING FIXTURES WITHIN THE UNITS SHALL BE ENERGY STAR RATED. C. EMERGENCY FIXTURES SHALL BE WIRED UNSWITCHED TO THE CIRCUIT INDICATED OR EMERGENCY FIXTURES SHALL BE WIRED UNSWITCHED TO THE CIRCUIT INDICATED OR TO THE LOCAL LIGHTING CIRCUIT PER NATIONAL ELECTRIC CODE. 18. THE MANUFACTURER AND MODEL NUMBER SHOWN ON THE LIGHT FIXTURE SCHEDULE THE MANUFACTURER AND MODEL NUMBER SHOWN ON THE LIGHT FIXTURE SCHEDULE INDICATES THE STYLE, QUALITY AND STANDARD OF PERFORMANCE REQUIRED. OTHER MANUFACTURERS WITH EQUAL PRODUCTS ARE ACCEPTABLE ON APPROVAL. 19. COORDINATE LIGHTING LAYOUT WITH ARCHITECTURAL CEILING GRID. COORDINATE LIGHTING LAYOUT WITH ARCHITECTURAL CEILING GRID. 20. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE TYPE OF CEILING SYSTEM WITH THE THE ELECTRICAL CONTRACTOR SHALL VERIFY THE TYPE OF CEILING SYSTEM WITH THE GENERAL CONTRACTOR. TO INSURE THAT ALL RECESSED LIGHTING FIXTURES ARE COMPATIBLE WITH THE CEILING SYSTEM BEING INSTALLED, LIGHTING FIXTURES SHOULD NOT BE ORDERED UNTIL THE TYPE OF CEILING HAS BEEN VERIFIED. 21. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT ALL DOOR SWINGS ARE CORRECT THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT ALL DOOR SWINGS ARE CORRECT BEFORE ROUGHING IN LIGHT SWITCH OUTLETS. LIGHT SWITCHES SHALL NOT BE LESS THAN 3 NOR MORE THAN 12 INCHES FROM DOOR TRIM. 22. LIGHTING SHOWN WITH TWO SWITCHES SHALL HAVE TWO BALLASTS PER FIXTURE, LIGHTING SHOWN WITH TWO SWITCHES SHALL HAVE TWO BALLASTS PER FIXTURE, CIRCUIT SUCH THAT THE INBOARD AND OUTBOARD LAMPS ARE SEPARATELY SWITCHED. 23. SUSPENDED LIGHTING FIXTURES SHALL NOT BE SOLELY SUPPORTED FROM MAIN SUSPENDED LIGHTING FIXTURES SHALL NOT BE SOLELY SUPPORTED FROM MAIN CHANNELS OR TEES OF CEILING SUSPENSION SYSTEM. SUPPORT FIXTURES INDEPENDENTLY OF CEILING MATERIALS. 24. LAY-IN FIXTURES MUST BE INDEPENDENTLY SUPPORTED BY BUILDING STRUCTURE IF LAY-IN FIXTURES MUST BE INDEPENDENTLY SUPPORTED BY BUILDING STRUCTURE IF CEILING GRID IS NOT RATED AND/OR DESIGNED TO SUPPORT FIXTURES. 25. MOUNT ALL WALL MOUNTED TELEPHONE/DATA OUTLETS AT 20" AFF TO TOP, UNLESS MOUNT ALL WALL MOUNTED TELEPHONE/DATA OUTLETS AT 20" AFF TO TOP, UNLESS OTHERWISE NOTED. ADJUST TO MATCH MASONRY COURSES IF APPLICABLE. FOR WALL MOUNT, PROVIDE A TWO GANG BOX, EXTRA DEEP WITH 2X4 REDUCER PLATE. PROVIDE A 1" CONDUIT AND STUB ABOVE CEILING. TERMINATE CONDUIT ABOVE CEILING WITH INSULATED BUSHING. INSTALL PULL WIRE. 26. CONTRACTOR SHALL ROUTE ALL TELEPHONE/DATA CABLES FROM OUTLETS SHOWN TO CONTRACTOR SHALL ROUTE ALL TELEPHONE/DATA CABLES FROM OUTLETS SHOWN TO DEMARCATION POINT. CONTRACTOR SHALL PROVED CONDUIT FROM UTILITY CONNECTION TO DEMARCATION POINT. TELEPHONE/DATA SERVICE SHALL BE UNDERGROUND. 27. LOCATIONS FOR ELECTRICAL COMPONENTS INDICATED ON THE DRAWINGS ARE LOCATIONS FOR ELECTRICAL COMPONENTS INDICATED ON THE DRAWINGS ARE SCHEMATIC, UNLESS WRITTEN DIMENSIONS ARE GIVEN. THESE LOCATIONS SHALL BE FOLLOWED AS CLOSELY AS THE ACTUAL CONSTRUCTION AND THE WORK OF OTHER TRADES WILL ALLOW. EXACT LOCATIONS OF ALL COMPONENTS SHALL BE VERIFIED IN THE FIELD, PRIOR TO INSTALLATION. ADJUST LOCATIONS OF COMPONENTS AS REQUIRED TO AVOID INTERFERENCES WITH MECHANICAL EQUIPMENT AND OTHER BUILDING ELEMENTS. 28. PRIOR TO LIGHT FIXTURE AND OVERHEAD RACEWAY INSTALLATION, VERIFY THAT THESE PRIOR TO LIGHT FIXTURE AND OVERHEAD RACEWAY INSTALLATION, VERIFY THAT THESE COMPONENTS CAN BE INSTALLED AT THE SPECIFIED HEIGHT ABOVE FINISHED FLOOR, INCLUDING ALLOWANCES FOR DUCTWORK AND PIPING. ADJUST LOCATIONS OF COMPONENTS AS REQUIRED TO OBTAIN THE INDICATED LIGHT FIXTURE MOUNTING HEIGHTS,SUBJECT TO THE APPROVAL OF THE A/E. 29. SMOKE DETECTORS SHALL BE CEILING MOUNTED, MINIMUM 6 INCHES FROM WALL. SMOKE DETECTORS SHALL BE CEILING MOUNTED, MINIMUM 6 INCHES FROM WALL. SMOKE DETECTORS SHALL BE CONNECTABLE, SIMULTANEOUS NOTIFICATION TYPE. 30. INTERCONNECTION CABLE BETWEEN INDOOR AND OUTDOOR MINISPLIT UNITS, SHALL BE INTERCONNECTION CABLE BETWEEN INDOOR AND OUTDOOR MINISPLIT UNITS, SHALL BE LISTED AS SUITABLE FOR THE APPLICATION. TYPE TC CABLE SHALL NOT BE PERMITTED. SOUTHWIRE EZ-IN MINISPLIT CABLE OR EQUAL. 31. MAJOR ITEMS ARE SHOWN ON THE PROJECT PLANS. SUBCONTRACTOR SHALL BE MAJOR ITEMS ARE SHOWN ON THE PROJECT PLANS. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL INCIDENTAL ITEMS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM. 32. ELECTRICAL WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AS TO ELECTRICAL WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AS TO SCHEDULING, DIMENSIONING AND LOCATION OF EQUIPMENT. 33. EACH BUILDING ELECTRIC SERVICE SHALL BE GROUNDED PER NATIONAL ELECTRIC CODE, EACH BUILDING ELECTRIC SERVICE SHALL BE GROUNDED PER NATIONAL ELECTRIC CODE, INCLUDING BUT NOT LIMITED TO CONNECTION TO METALLIC UNDERGROUND WATER PIPE AND AT LEAST TWO 10'X5/8" DRIVEN COPPER GROUND ROD. BOND TO THE BUILDING STRUCTURAL STEEL AT THE NEAREST POINT, WHERE APPLICABLE. GROUNDING SYSTEM CONNECTIONS BELOW GRADE AND IN WET/DAMP LOCATIONS SHALL BE CADWELD EXOTHERMIC METHOD. GROUNDING CONNECTIONS INDOORS AND IN DRY LOCATIONS MAY BE MECHANICAL COMPRESSION TYPE. TOTAL RESISTANCE OF THE GROUNDING SYSTEM SHALL BE LESS THAN 25 OHMS PER NEC. PROVIDE ADDITIONAL GROUND RODS AS NECESSARY TO ACHIEVE THIS RESULT. 34. ALL CONDUIT SYSTEMS, EQUIPMENT CASES, MOTOR FRAMES AND SYSTEM NEUTRAL ALL CONDUIT SYSTEMS, EQUIPMENT CASES, MOTOR FRAMES AND SYSTEM NEUTRAL CONDUCTORS SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, ARTICLE 250. 35. CONDUIT SHALL BE USED AS FOLLOWS; PVC SCHEDULE 80 WHERE EXPOSED CONDUIT SHALL BE USED AS FOLLOWS; PVC SCHEDULE 80 WHERE EXPOSED OUTDOORS; PVC SCHEDULE 40 WHERE BELOW GRADE; FLEXIBLE FOR EQUIPMENT CONNECTIONS AND EMT OTHERWISE OR WHERE INDICATED. MC CABLE MAY BE USED FOR WHIPS AND IN WALLS. A SEPARATE GREEN INSULATED GROUND WIRE SHALL BE INSTALLED IN ALL CONDUITS. ALL CONDUIT SHALL BE NEATLY RUN AND SUPPORTED PER NATIONAL ELECTRIC CODE. 36. WHERE MORE THAN THREE CURRENT CARRYING CONDUCTORS ARE CONTAINED IN A WHERE MORE THAN THREE CURRENT CARRYING CONDUCTORS ARE CONTAINED IN A SINGLE CONDUIT, ADJUST CONDUCTOR SIZES AS NECESSARY TO ACCOUNT FOR DE-RATING THEIR AMPACITY IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. GENERALLY, THERE SHOULD BE NO MORE THAN EIGHT CURRENT CARRYING CONDUCTORS (INCLUDING NEUTRALS) IN A CONDUIT. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. 37. PANELBOARDS AND LOAD CENTERS SHALL BE SQUARE-D OR EQUAL, PROVIDED WITH PANELBOARDS AND LOAD CENTERS SHALL BE SQUARE-D OR EQUAL, PROVIDED WITH NEMA 1 ENCLOSURE WITH DOOR FOR INDOOR LOCATIONS AND NEMA 3R ENCLOSURE WITH DOOR FOR EXTERIOR AND FOR WET/DAMP LOCATIONS. PROVIDE SOLID COPPER OR ALUMINUM BUS, FULL SIZE NEUTRAL BAR AND GROUNDING BAR WITH LUGS FOR CABLE CONNECTION. PROVIDE TYPEWRITTEN DIRECTORY WITH TRANSPARENT COVER INDICATING CIRCUITS, SPACES AND SPARES FOR ALL PANELS. 38. ALL SAFETY SWITCHES SHALL BE SIMILAR OR EQUAL TO SQUARE-D, WITH PADLOCK ALL SAFETY SWITCHES SHALL BE SIMILAR OR EQUAL TO SQUARE-D, WITH PADLOCK CAPABILITY. PROVIDE NEMA-1 SWITCHES INDOORS AND NEMA-3R SWITCHES OUTDOORS AND IN WET OR DAMP LOCATIONS. 39. LIGHT SWITCHES LIGHT SWITCHES A. 15A OR 20A, 120/277 VOLT, SIDEWIRED, TOGGLE SWITCH, THERMOPLASTIC PLATE IN 15A OR 20A, 120/277 VOLT, SIDEWIRED, TOGGLE SWITCH, THERMOPLASTIC PLATE IN FINISH SELECTED BY ARCHITECT. PROVIDE 1-POLE, 2-POLE, OR 3-WAY AS REQUIRED FOR SWITCHING CONTROL. 40. DUPLEX 120V RECEPTACLES SHALL BE 15 OR 20 AMP, DUPLEX RECEPTACLES, WITH DUPLEX 120V RECEPTACLES SHALL BE 15 OR 20 AMP, DUPLEX RECEPTACLES, WITH THERMOPLASTIC PLATE IN FINISH SELECTED BY ARCHITECT. WHERE QUADPLEX RECEPTACLES ARE NOTED, PROVIDE TWO DUPLEX RECEPTACLES ON A COMMON PLATE. FLUSH RECEPTACLES ON CMU WALL MAY USE OVERSIZED PLATES. PROVIDE TAMPER-RESISTANT RECEPTACLES WHERE REQUIRED BY CODE. 41. DUPLEX GROUND FAULT RECEPTACLES INDOORS SHALL BE 20 AMP DUPLEX GFI TYPE DUPLEX GROUND FAULT RECEPTACLES INDOORS SHALL BE 20 AMP DUPLEX GFI TYPE WITH FEED THROUGH AND STANDARD COVER. 42. NEW WEATHERPROOF GROUND FAULT DUPLEX RECEPTACLES SHALL BE 20 AMP DUPLEX NEW WEATHERPROOF GROUND FAULT DUPLEX RECEPTACLES SHALL BE 20 AMP DUPLEX GFI TYPE WITH LEXAN WEATHERPROOF WHILE-IN-USE COVER. 43. ACCESS SHALL BE MAINTAINED TO ALL WIRING JUNCTION BOXES IN ACCORDANCE WITH ACCESS SHALL BE MAINTAINED TO ALL WIRING JUNCTION BOXES IN ACCORDANCE WITH THE NEC. IF ANY EXISTING WIRING JUNCTION BOXES ARE AFFECTED BY THESE RENOVATIONS, TAKE MEASURES TO RELOCATE, ROTATE, OR OTHERWISE MAKE THE AFFECTED BOXES ACCESSIBLE. 44. ELECTRICAL IDENTIFICATION SHALL BE PROVIDED IN ACCORDANCE WITH THE FOLLOWING ELECTRICAL IDENTIFICATION SHALL BE PROVIDED IN ACCORDANCE WITH THE FOLLOWING PROVISIONS: A. ENGRAVING STOCK MELAMINE PLASTIC LAMINATE LABELS, BLACK WITH WHITE CORE, ENGRAVING STOCK MELAMINE PLASTIC LAMINATE LABELS, BLACK WITH WHITE CORE, FASTENED WITH PANHEAD SCREWS AND EXPANSION SHIELDS ON BLOCK WALLS OR CONTACT TYPE PERMANENT ADHESIVE FOR DIRECT FASTENING TO EQUIPMENT FOR ALL MAJOR PIECES OR ELECTRICAL EQUIPMENT INCLUDING AS A MINIMUM BUT NOT LIMITED TO ALL SAFETY DISCONNECT SWITCHES AND ALL PANELBOARDS. B. PROVIDE MANUFACTURERS STANDARD VINYL CLOTH SELF ADHESIVE CABLE/ PROVIDE MANUFACTURERS STANDARD VINYL CLOTH SELF ADHESIVE CABLE/ CONDUCTOR MARKERS OR WRAP-AROUND TYPE NUMBERED TO SHOW CIRCUIT IDENTIFICATION IN EACH BOX/ENCLOSURE/CABINET WHERE WIRES OF MORE THAN ONE CIRCUIT OR SYSTEM ARE PRESENT. MATCH IDENTIFICATION WITH OTHER MARKING SYSTEMS USED.
AutoCAD SHX Text
F/A SYSTEM GENERAL NOTES
AutoCAD SHX Text
1. CLASS 'B' WIRING SYSTEM REQUIRED CLASS 'B' WIRING SYSTEM REQUIRED 2. ALL WIRING TO BE RED JACKET TYPE FPL 125 DEG C 300 VOLT RATED. ALL WIRING ALL WIRING TO BE RED JACKET TYPE FPL 125 DEG C 300 VOLT RATED. ALL WIRING CONCEALED IN WALLS, FLOORS, AND NON ACCESSIBLE CEILINGS SHALL BE IN CONDUIT. 3. OPEN FIRE ALARM CABLES SHALL BE PERMITTED ONLY IN SPACES WHERE THE CEILING OPEN FIRE ALARM CABLES SHALL BE PERMITTED ONLY IN SPACES WHERE THE CEILING IS TOTALLY ACCESSIBLE. FIRE ALARM CABLES SHALL BE SUPPORTED AT NO GREATER THAN 12' INTERVALS AND SECURELY FASTENED TO THE BUILDING STRUCTURE. 4. PROVIDE ADEQUATE ALAMR CIRCUIT QUANTITES FOR ALL DEVICES. PROVIDE ADEQUATE ALAMR CIRCUIT QUANTITES FOR ALL DEVICES. 5. PROVIDE 120 VAC TO SMOKE DAMPERS CONTROLLED BY A SMOKE DETECTOR. PROVIDE 120 VAC TO SMOKE DAMPERS CONTROLLED BY A SMOKE DETECTOR. 6. INSTALL IN MIN " CONDUIT UNLESS OTHERWISE NOTED. INSTALL IN MIN " CONDUIT UNLESS OTHERWISE NOTED. 34" CONDUIT UNLESS OTHERWISE NOTED. 7. STROBES SHALL BE RATED 30CD MINIMUM IN ROOMS LARGER THAN 50'X50'. 15 CD STROBES SHALL BE RATED 30CD MINIMUM IN ROOMS LARGER THAN 50'X50'. 15 CD ELSWHERE UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
A. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF DEMOLITION AND ADDITIONAL REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF DEMOLITION AND ADDITIONAL DEMOLITION REQUIREMENTS. COORDINATE WITH BUILDING MANAGEMENT SYSTEM FOR ITEMS REQUIRED TO REMAIN. B. REMOVE ALL OF THE EXISTING RECEPTACLES, JUNCTION BOXES, ELECTRICAL PANELS, REMOVE ALL OF THE EXISTING RECEPTACLES, JUNCTION BOXES, ELECTRICAL PANELS, CONDUIT, WIRE, AND APPURTENANCES IN THE AFFECTED AREA UNLESS OTHERWISE NOTED. C. ELECTRICALLY DISCONNECT EXISTING MECHANICAL AND PLUMBING EQUIPMENT TO ALLOW FOR ELECTRICALLY DISCONNECT EXISTING MECHANICAL AND PLUMBING EQUIPMENT TO ALLOW FOR REMOVAL. REMOVE ASSOCIATED CIRCUIT BACK TO SOURCE. COORDINATE WITH MECHANICAL AND PLUMBING CONTRACTORS. D. REMOVE ALL EXISTING LIGHT (INTERIOR AND EXTERIOR) FIXTURES, EXIT LIGHTS, EMERGENCY REMOVE ALL EXISTING LIGHT (INTERIOR AND EXTERIOR) FIXTURES, EXIT LIGHTS, EMERGENCY LIGHTING FIXTURES AND ASSOCIATED LIGHT SWITCHES, JUNCTION BOXES, CONDUIT, WIRE AND APPURTENANCES BACK TO SOURCE UNLESS OTHERWISE NOTED. E. COORDINATE CONDUIT REMOVAL WITH ARCHITECTURAL DEMOLITION.COORDINATE CONDUIT REMOVAL WITH ARCHITECTURAL DEMOLITION.
AutoCAD SHX Text
DEMOLITION NOTES
AutoCAD SHX Text
E-2
“”
07/20/20
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
SPECIFICATIONS
AutoCAD SHX Text
SECTION 16000 - ELECTRICAL SPECIFICATIONS PART 1 - GENERAL 1.1 BASIC ELECTRICAL METHODS A. DRAWINGS ARE SCHEMATIC AND DIAGRAMMATIC. ELECTRICAL WORK SHALL BE PERFORMED IN A DRAWINGS ARE SCHEMATIC AND DIAGRAMMATIC. ELECTRICAL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER IN ORDER TO FUNCTION PROPERLY AND FIT WITHIN BUILDING CONSTRUCTION AND FINISHES. ELECTRICAL CONDUCTORS, CONDUIT, COMPONENTS, NOT SHOWN OR SPECIFIED, WHICH ARE REQUIRED FOR ANY DEVICE OR SYSTEM TO PRODUCE A COMPLETE AND OPERATIVE SYSTEM ARE REQUIRED TO BE FURNISHED AND INSTALLED. B. ROUTE CONDUITS AND WIRING ASSOCIATED WITH NEW EQUIPMENT AND SYSTEMS ABOVE CEILINGS ROUTE CONDUITS AND WIRING ASSOCIATED WITH NEW EQUIPMENT AND SYSTEMS ABOVE CEILINGS AND CONCEALED WITHIN BUILDING STRUCTURE AS MUCH AS POSSIBLE. C. CIRCUIT GROUPING-PROVIDE PROPER NUMBER OF CONDUCTORS AND CONDUITS OR CABLES TO CIRCUIT GROUPING-PROVIDE PROPER NUMBER OF CONDUCTORS AND CONDUITS OR CABLES TO PROVIDE OPERATIVE SYSTEM AS INDICATED ON CONTRACT DOCUMENTS. DO NOT REGROUP ANY FEEDER CIRCUITS, BRANCH CIRCUITS, AND HOME RUNS AT ANY POINT, FROM THAT SHOWN ON CONTRACT DOCUMENTS. D. NEW EQUIPMENT, SWITCHES, DEVICES, SHOWN MOUNTED ON AND/OR ADJACENT TO EQUIPMENT, NEW EQUIPMENT, SWITCHES, DEVICES, SHOWN MOUNTED ON AND/OR ADJACENT TO EQUIPMENT, WHICH IF INSTALLED, WOULD IMPAIR PROPER OPERATION OF NEW EQUIPMENT, SHALL BE RELOCATED AS REQUIRED SO EQUIPMENT WILL FUNCTION PROPERLY. E. SEAL AND MAKE PERMANENTLY WATERTIGHT PENETRATIONS BY ELECTRICAL RACEWAYS OR SEAL AND MAKE PERMANENTLY WATERTIGHT PENETRATIONS BY ELECTRICAL RACEWAYS OR EQUIPMENT THROUGH ROOFS, CEILINGS, WALLS OR FLOORS. 1. SEAL PENETRATIONS IN NON-FIRE RATED CEILINGS, WALLS OR FLOORS. SEAL PENETRATIONS IN NON-FIRE RATED CEILINGS, WALLS OR FLOORS. 2. SEAL PENETRATIONS IN FIRE RATED WALLS WITH FIRE RATED MATERIAL. SEAL PENETRATIONS IN FIRE RATED WALLS WITH FIRE RATED MATERIAL. F. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS, INCLUDING SCREWS AND BOLTS, IN TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR EQUIPMENT CONNECTORS. G. INSTALL EQUIPMENT AND MATERIALS TO PROVIDE REQUIRED MAINTENANCE AND CODE WORKING INSTALL EQUIPMENT AND MATERIALS TO PROVIDE REQUIRED MAINTENANCE AND CODE WORKING CLEARANCE FOR SERVICING AND MAINTENANCE. COORDINATE FINAL LOCATION OF CONCEALED EQUIPMENT AND DEVICES REQUIRING ACCESS WITH FINAL LOCATION OF REQUIRED ACCESS PANELS AND DOORS. ALLOW REQUIRED SPACE FOR REMOVAL OF PARTS THAT REQUIRE REPLACEMENT OR SERVICING. 1.2 QUALITY ASSURANCE A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. B. COMPLY WITH 2014 NFPA 70 - NATIONAL ELECTRICAL CODE. COMPLY WITH 2014 NFPA 70 - NATIONAL ELECTRICAL CODE. PART 2 - PRODUCTS 2.1 GENERAL A. ALL DEVICES AND COMPONENTS SHALL BE SPECIFICATION GRADE PRODUCTS. SIZES, WATTAGES, ALL DEVICES AND COMPONENTS SHALL BE SPECIFICATION GRADE PRODUCTS. SIZES, WATTAGES, AMPACITIES, AND OTHER SPECIFICS ARE INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN. ALL ELECTRICAL COMPONENTS SHALL BE READILY AVAILABLE ITEMS WHICH ARE CURRENTLY IN PRODUCTION BY THE MANUFACTURER. 2.2 HANGERS AND SUPPORTS A. PRODUCT REQUIREMENTS: FURNISH AND INSTALL APPROVED MATERIALS, SIZES, AND TYPES OF PRODUCT REQUIREMENTS: FURNISH AND INSTALL APPROVED MATERIALS, SIZES, AND TYPES OF ANCHORS, FASTENERS, AND SUPPORTS TO CARRY LOADS OF EQUIPMENT AND CONDUIT. B. MATERIALS AND FINISHES: CORROSION RESISTIVE. MATERIALS AND FINISHES: CORROSION RESISTIVE. C. ANCHORS AND FASTENERS: ANCHORS AND FASTENERS: 1. CONCRETE SURFACES: SELF-DRILLING ANCHORS AND EXPANSION ANCHORS. CONCRETE SURFACES: SELF-DRILLING ANCHORS AND EXPANSION ANCHORS. 2. HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: TOGGLE BOLTS AND HOLLOW WALL HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: TOGGLE BOLTS AND HOLLOW WALL FASTENERS. 3. SOLID MASONRY WALLS: EXPANSION ANCHORS. SOLID MASONRY WALLS: EXPANSION ANCHORS. 4. SHEET METAL: SHEET METAL SCREWS. SHEET METAL: SHEET METAL SCREWS. 5. WOOD: WOOD SCREWS. WOOD: WOOD SCREWS. 2.3 RECEPTACLES A. DUPLEX RECEPTACLES: SPECIFICATION GRADE DUPLEX RECEPTACLES, 3-WIRE GROUNDING TYPE, DUPLEX RECEPTACLES: SPECIFICATION GRADE DUPLEX RECEPTACLES, 3-WIRE GROUNDING TYPE, WIRED WITH SCREW TERMINALS, 125 VOLT, 15 AMP, NEMA 5-15R CONFIGURATION. EXPOSED FACES TO BE WHITE. COVER PLATES TO BE WHITE. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES WHERE INDICATED ON THE DRAWINGS, WITH TEST AND RESET BUTTONS ON THE EXPOSED FACE, CLEARLY MARKED. THROUGH-FEED GFCI RECEPTACLES MAY BE USED, IF ALL PROTECTED RECEPTACLES ARE SO MARKED. DEVICES SHOWN AS EXISTING DUPLEX OR GFCI RECEPTACLES SHALL BE REPLACED WITH NEW DEVICES AND COVERS. 2.4 CONDUIT AND CABLE A. ALL INDOOR CONDUCTORS SHALL BE RUN IN ELECTRICAL METALLIC TUBING (EMT), 3/4" MINIMUM ALL INDOOR CONDUCTORS SHALL BE RUN IN ELECTRICAL METALLIC TUBING (EMT), 3/4" MINIMUM SIZE. FLEXIBLE METAL CONDUITS OR MC CABLE SHALL TERMINATE AT A JUNCTION BOX LOCATED ABOVE THE ACOUSTICAL CEILING, DIRECTLY ABOVE THE DEVICE SERVED BY THE CONDUIT. MINIMUM CONDUIT SIZE SHALL BE 3/4", EXCEPT AS SPECIFICALLY NOTED OTHERWISE. FITTINGS FOR EMT SHALL BE STEEL SET SCREW, OR GLAND COMPRESSION TYPE. PROVIDE PULL BOXES AT NECESSARY POINT TO PREVENT INJURY TO INSULATION OR DAMAGE FROM PULLING RESISTANCE ON LONG CIRCUIT ROUTES. B. EXTERIOR CIRCUITS SHALL BE RUN IN PVC TYPE CONDUIT. SCHEDULE 80 CONDUIT SHALL BE EXTERIOR CIRCUITS SHALL BE RUN IN PVC TYPE CONDUIT. SCHEDULE 80 CONDUIT SHALL BE USED FOR EXPOSED LOCATIONS, SCHEDULE 40 FOR CONCEALED LOCATIONS NOT SUBJECT TO DAMAGE. C. AT ALL CONNECTIONS TO MOTORIZED EQUIPMENT, EQUIPMENT SUBJECT TO VIBRATION, AND AT ALL CONNECTIONS TO MOTORIZED EQUIPMENT, EQUIPMENT SUBJECT TO VIBRATION, AND EXPOSED EQUIPMENT, PROVIDE AN 18 INCH MINIMUM AND 48 INCH MAXIMUM SECTION OF LIQUID-TIGHT FLEXIBLE METAL CONDUIT. D. ALL CIRCUITS SHALL BE GROUNDED PER NEC AND INCLUDE AN EQUIPMENT GROUNDING ALL CIRCUITS SHALL BE GROUNDED PER NEC AND INCLUDE AN EQUIPMENT GROUNDING CONDUCTOR 2.5 GENERAL REQUIREMENTS FOR DATA/TELEPHONE/TV WIRING A. ALL VOICE/DATA WIRING SHALL BE RUN IN EMT, WITH PLASTIC BUSHINGS, 1" MINIMUM SIZE, WITH ALL VOICE/DATA WIRING SHALL BE RUN IN EMT, WITH PLASTIC BUSHINGS, 1" MINIMUM SIZE, WITH NYLON PULL STRING INSTALLED WITH 18 INCH EXCESS COILED AT EACH END, IN LOCATIONS INDICATED ON THE DRAWINGS. ROUTE DATA/TELEPHONE CONDUITS FROM OUTLETS INTO CEILING SPACE. WIRING SHALL NOT BE REQUIRED TO BE IN CONDUIT IN CEILING SPACES IF THE AUTHORITY HAVING JURISDICTION DOES NOT REQUIRE AS SUCH. CONDUIT SHALL TURN OUT TOWARD THE SPACE 6 INCHES FROM WALL AT HEIGHT APPROXIMATELY 18 INCHES ABOVE SUSPENDED ACOUSTICAL CEILINGS, IN AN ACCESSIBLE LOCATION. CONTRACTOR SHALL BE RESPONSIBLE TO CONNECT DATA/TELEPHONE/TV CIRCUIT TO EXISTING DEMARCATION POINT. B. ALL DATA/TELEPHONE CIRCUITS SHALL UTILIZE CAT 5 CABLE. ALL DATA/TELEPHONE CIRCUITS SHALL UTILIZE CAT 5 CABLE. C. RJ 45 RECEPTACLES SHALL UTILIZE TWO CIRCUITS. RJ 45 RECEPTACLES SHALL UTILIZE TWO CIRCUITS. D. THE PROPERTY MANAGER WILL SET UP THE SERVICE PROVIDER FOR EACH UNIT. THE PROPERTY MANAGER WILL SET UP THE SERVICE PROVIDER FOR EACH UNIT. E. THE TELCO BOX IS ON SITE. RUN COAX AND CAT 5 CABLE TO CENTRAL PANEL FOR EACH UNIT. THE TELCO BOX IS ON SITE. RUN COAX AND CAT 5 CABLE TO CENTRAL PANEL FOR EACH UNIT. F. PROVIDE A CENTRAL BUILDING HOUSE PANEL FOR THE BUILDING SUCH THAT THE SERVICE PROVIDE A CENTRAL BUILDING HOUSE PANEL FOR THE BUILDING SUCH THAT THE SERVICE PROVIDER CAN ACTIVATE EACH SERVICE BY UNIT. PANEL SHALL BE LOCATED IN A CONDITIONED SPACE. G. NETWORK DISTRIBUTION POINT IN A CLOSET, SHELF, POWER OUTLETS PER UNIT. NETWORK DISTRIBUTION POINT IN A CLOSET, SHELF, POWER OUTLETS PER UNIT. H. COIL WIRES AT HOUSE PANEL. COIL WIRES AT HOUSE PANEL. I. WIRES FROM ROOMS END IN A MALE CONNECTION IN THE UNIT CLOSET. WIRES FROM ROOMS END IN A MALE CONNECTION IN THE UNIT CLOSET. J. WIRES FROM HOUSE PANEL SHALL END IN A FEMALE CONNECTION (PATCH PANEL) IN THE UNIT WIRES FROM HOUSE PANEL SHALL END IN A FEMALE CONNECTION (PATCH PANEL) IN THE UNIT CLOSET. K. THE FEMALE CONNECTION IN THE UNIT CLOSET SHALL BE A LABELED RECEPTACLE. GANG FACE THE FEMALE CONNECTION IN THE UNIT CLOSET SHALL BE A LABELED RECEPTACLE. GANG FACE PLATES. 2.6 CONDUCTORS A. ALL BRANCH CIRCUIT WIRE SHALL BE COPPER CONDUCTOR, 600 VOLT, THWN, WITH ALL BRANCH CIRCUIT WIRE SHALL BE COPPER CONDUCTOR, 600 VOLT, THWN, WITH MOISTURE-RESISTANT INSULATION. SIZE ALL CONDUCTORS PER NEC, PROVIDING VOLTAGE DROP OF 3 PER CENT OR LESS. FOR ALL USES, MINIMUM WIRE SIZE SHALL BE AWG #12. WIRE SIZES LARGER THAN #10 SHALL BE STRANDED, ALL OTHERS SHALL BE SOLID. PROVIDE AMPACITY BASED ON 75 DEGREES C RATING FOR CONDUCTOR SIZES #1, AND LARGER, AND BASED ON 60 DEGREE RATING FOR CONDUCTOR SIZES SMALLER THAN #1 AWG. PROVIDE FULL RATED NEUTRAL CONDUCTORS. TYPE AC ARMORED CABLE SHALL NOT BE USED. SERVICE ENTRANCE CABLE AND FEEDER CABLES MAY BE ALUMINUM THWN PROVIDED THE ARRANGEMENT OF CONDUCTORS AND CONDUIT HAS THE SAME AMPACITY AS THE COPPER CONDUCTORS LISTED IN THE FEEDER SCHEDULE. 2.7 ELECTRICAL IDENTIFICATION A. PROVIDE PLASTIC NAMEPLATES AT ALL EXISTING PANELBOARDS WHERE CIRCUITS ARE MODIFIED, PROVIDE PLASTIC NAMEPLATES AT ALL EXISTING PANELBOARDS WHERE CIRCUITS ARE MODIFIED, AND AT ALL DISCONNECTS. NAMEPLATES SHALL BE THREE-LAYER LAMINATED PLASTIC, WHITE LETTERS ENGRAVED INTO A BLACK BACKGROUND, WITH 1/4" HIGH LETTERS. FOR DISCONNECTS, IDENTIFY EQUIPMENT SERVED, INCLUDING VOLTAGE RATINGS. FOR PANELBOARDS, IDENTIFY PANELBOARD, VOLTAGE, NUMBER OF PHASES, AND THE DISTRIBUTION PANELBOARD WHICH PROVIDES THE POWER FEED. B. PROVIDE NEATLY TYPED CIRCUIT BREAKER DIRECTORY IN ALL PANELBOARDS, INCLUDING EXISTING PROVIDE NEATLY TYPED CIRCUIT BREAKER DIRECTORY IN ALL PANELBOARDS, INCLUDING EXISTING PANELBOARDS WITH CIRCUITS MODIFIED AS PART OF THIS WORK. DIRECTORY SHALL SHOW THE CIRCUIT NUMBER AND COMPLETE DESCRIPTION OF ALL COMPONENTS ON ALL CIRCUITS, INCLUDING ROOM NUMBERS OR ROOM NAMES WHERE COMPONENTS ARE LOCATED, AS APPROVED BY THE OWNER. C. PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARDS, PULL BOXES, OUTLET BOXES, PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARDS, PULL BOXES, OUTLET BOXES, JUNCTION BOXES, AND AT LOAD CONNECTION. IDENTIFY WIRE WITH BRANCH CIRCUIT OR FEEDER NUMBER FOR POWER AND LIGHTING CIRCUITS, AND WITH CONTROL WIRE NUMBER FOR EQUIPMENT, AS IDENTIFIED ON EQUIPMENT MANUFACTURER'S SHOP DRAWINGS FOR CONTROL WIRING. D. LABEL ALL RECEPTACLES THAT HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION. LABEL ALL RECEPTACLES THAT HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION. 2.8 DISCONNECTS A. QUICK MAKE, QUICK BREAK HEAVY DUTY DISCONNECT. VOLTAGE, PHASE, AND POLES AS QUICK MAKE, QUICK BREAK HEAVY DUTY DISCONNECT. VOLTAGE, PHASE, AND POLES AS SCHEDULED, SAFETY SWITCHES, FUSED OR NON FUSED AS SCHEDULED. NEMA 1 OR NEMA 3R ENCLOSURE AS NOTED. 2.9 OTHER MATERIALS A. PROVIDE OTHER MATERIALS AND MISCELLANEOUS COMPONENTS, NOT SPECIFICALLY DESCRIBED BUT PROVIDE OTHER MATERIALS AND MISCELLANEOUS COMPONENTS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR SUBJECT TO THE APPROVAL OF THE A/E. 2.10 PANELBOARDS A. LIGHTING AND APPLIANCE PANELBOARDS: (120 /240 VOLT, 1 PHASE, 3 WIRE) EQUAL TO CUTLER LIGHTING AND APPLIANCE PANELBOARDS: (120 /240 VOLT, 1 PHASE, 3 WIRE) EQUAL TO CUTLER HAMMER, SIEMENS, SQUARE-D, GENERAL ELECTRIC, AND APPROVED PRODUCTS. B. GENERAL: INSTALL AND FURNISH CIRCUIT BREAKER PANELBOARDS AS SHOWN ON THE PLANS AND GENERAL: INSTALL AND FURNISH CIRCUIT BREAKER PANELBOARDS AS SHOWN ON THE PLANS AND INDICATED ON THE PANELBOARD SCHEDULE. THE PANELBOARDS SHALL BE DEAD FRONT EQUIPPED WITH MOLDED CASE CIRCUIT BREAKERS, ENCLOSURES, BUSES, GROUND AND NEUTRAL BARS, FRONT COVERS WITH DOORS INCLUDING DIRECTORY FRAME. CIRCUIT BREAKERS SHALL BE REMOVABLE WITHOUT DISTURBING ADJACENT UNITS. SUB PANEL NEUTRALS SHALL BE ISOLATED FROM THEIR ENCLOSURES AND GROUNDS. PANELS USED AS SERVICE ENTRANCE DUTY SHALL BE U.L. LISTED AND LABELED AS SUITABLE FOR SERVICE ENTRANCE EQUIPMENT. USE OF LOAD CENTERS IS NOT ACCEPTABLE. C. CIRCUIT BREAKERS: SHALL BE THERMAL-MAGNETIC TYPES WITH INVERSE TIME ELEMENT CIRCUIT BREAKERS: SHALL BE THERMAL-MAGNETIC TYPES WITH INVERSE TIME ELEMENT CHARACTERISTICS, UNLESS OTHERWISE SHOWN. MULTI-POLE BREAKERS SHALL AUTOMATICALLY OPEN ALL POLES WHEN AN OVERLOAD OCCURS IN ANY POLE. EXTERNAL TIE-HANDLE CONSTRUCTION WHERE ADJACENT POLES ARE ON THE SAME PHASE OR LEG WILL NOT BE ACCEPTED. ONE HALF 1/2 WIDTH (MINI) BREAKERS ARE NOT ACCEPTABLE. TANDEM BREAKERS ARE NOT ACCEPTABLE. BRANCH CIRCUIT BREAKERS USED FOR SWITCHING DUTY SHALL BE U.L. LISTED AS SWD TYPE. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED BY NEC SHALL BE PROVIDED BY GROUND FAULT CIRCUIT INTERRUPTING BREAKERS UNLESS OTHERWISE NOTED. MINIMUM MAIN BREAKER INTERRUPTING RATINGS SHALL BE 22,000 AIC SYMMETRICAL AT 250 VOLTS AS UNLESS SCHEDULED. BRANCH CIRCUIT BREAKERS SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 AIC SYMMETRICAL AT 250 VOLTS AC. UNUSED CIRCUIT BREAKER SPACE SHALL BE COVERED BY BLANK FILLERS. D. CONSTRUCTION: CONSTRUCTION: 1. PANELBOARD CABINETS AND FRONTS SHALL BE STEEL. THE SIZE OF THE WIRING GUTTERS AND PANELBOARD CABINETS AND FRONTS SHALL BE STEEL. THE SIZE OF THE WIRING GUTTERS AND GAUGE OF STEEL SHALL BE IN ACCORDANCE WITH NEMA STANDARDS AND NEC REQUIREMENTS. 2. DIRECTORY: PROVIDE A TYPE WRITTEN DIRECTORY CARD TO INDICATE THE CIRCUIT NUMBER, ITEM DIRECTORY: PROVIDE A TYPE WRITTEN DIRECTORY CARD TO INDICATE THE CIRCUIT NUMBER, ITEM CONNECTED, AND LOCATION OF EACH CIRCUIT. THE DIRECTORY CARD SHALL BE MOUNTED IN A METAL FRAME WITH A TRANSPARENT COVER. 3. PROVIDE AN ENGRAVED NAMEPLATE WITH THE PANELBOARD NAME AS SCHEDULED ON THE DRAWINGS. PROVIDE AN ENGRAVED NAMEPLATE WITH THE PANELBOARD NAME AS SCHEDULED ON THE DRAWINGS. 4. FINISH: FACTORY PRIMED WITH A RUST INHIBITING PRIMER AND PAINTED WITH A LIGHT GRAY ENAMEL FINISH: FACTORY PRIMED WITH A RUST INHIBITING PRIMER AND PAINTED WITH A LIGHT GRAY ENAMEL PAINT SIMILAR IN COLOR TO ANSI NO. 49. PROVIDE A SPRAY CAN OF MATCHING TOUCH-UP PAINT. 2.11 LIGHTING FIXTURES- PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. FURNISH FIXTURE TYPE, MODEL STYLE, COLOR AND FINISH AS INDICATED IN LIGHT FIXTURE SCHEDULE, AND NOTED IN THE SPECIFICATIONS FOR PARTICULAR LIGHT FIXTURES. A. FLUORESCENT FIXTURES: FURNISH FLUORESCENT FIXTURES COMPLETE WITH LAMPS AS SCHEDULED FLUORESCENT FIXTURES: FURNISH FLUORESCENT FIXTURES COMPLETE WITH LAMPS AS SCHEDULED AND HIGH EFFICIENCY ELECTRONIC BALLASTS, LESS THAN 10% THD AND U.L. APPROVED. FURNISH FLUORESCENT FIXTURES WITH LAMP SOCKETS COMPATIBLE WITH LAMP CONNECTION PINS. B. FLUORESCENT LAMPS: PROVIDE ENERGY SAVING LAMPS WITH WATTAGE AS SHOWN IN THE FLUORESCENT LAMPS: PROVIDE ENERGY SAVING LAMPS WITH WATTAGE AS SHOWN IN THE SCHEDULE. LAMPS SHALL GENERALLY BE T-8 TYPE, 32 WATT WITH BI-PIN SOCKETS. LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC OR PHILLIPS. PROVIDE LOW MERCURY CONTENT, TCLP EPA COMPLIANT LAMPS. LAMPS TO DELIVER 95% LUMEN MAINTENANCE AND REDUCED LAMP END BLACKENING. PROVIDE A CRI OF 75 OR GREATER FOR T-8 LAMPS USING 32 WATTS. THE COLOR TEMPERATURE SHALL BE 3500K. LAMPS SHALL HAVE GREEN COLORED END CAPS. COMPACT FLUORESCENTS SHALL HAVE 4 PIN TYPE SOCKETS. C. BALLASTS: 120 VOLT, 60 HERTZ, ELECTRONIC TYPE A, FLUORESCENT LAMP ELECTRONIC BALLAST BALLASTS: 120 VOLT, 60 HERTZ, ELECTRONIC TYPE A, FLUORESCENT LAMP ELECTRONIC BALLAST LESS THAN 10% THD, 32 WATT, SOUND RATING A. BALLAST SHALL BE OF THE PARALLEL LAMP CONNECTION DESIGN SUCH THAT LAMPS REMAIN FULLY ILLUMINATED IF ANY ADJACENT LAMP FAILS D. LENS AND ENCLOSURES: ACRYLIC FIXTURE LENS. WHERE SHOWN, PROVIDE ACRYLIC PRISMATIC LENS AND ENCLOSURES: ACRYLIC FIXTURE LENS. WHERE SHOWN, PROVIDE ACRYLIC PRISMATIC LENS, INJECTION MOLDED, ULTRAVIOLET STABILIZED. PARABOLIC LENS SHALL HAVE ALZAK ALUMINUM REFLECTORS, LOW IRIDESCENT TYPE, WITH CELL SIZE AND CONFIGURATION AS SHOWN IN THE FIXTURE SCHEDULE. MINIMUM LENS THICKNESS SHALL BE .125 INCHES. 2.12 ELECTRICAL EQUIPMENT AND CONNECTIONS TO MECHANICAL EQUIPMENT A. FURNISH AND INSTALL THE FOLLOWING: FURNISH AND INSTALL THE FOLLOWING: 1. CONDUIT, WIRING AND ELECTRICAL CONNECTIONS TO MOTORS, SAFETY SWITCHES, STARTERS, RELAYS, CONDUIT, WIRING AND ELECTRICAL CONNECTIONS TO MOTORS, SAFETY SWITCHES, STARTERS, RELAYS, ELECTRICAL INTERLOCK CIRCUITS, UNIT HEATERS, FAN COIL UNITS, AIR HANDLING UNITS, AND OTHER SIMILAR EQUIPMENT, REQUIRED FOR COMPLETE AND READY FOR OPERATION. 2. STARTERS AS INDICATED ON DRAWINGS EXCEPT CUSTOM DESIGNED STARTERS SUCH AS THOSE STARTERS AS INDICATED ON DRAWINGS EXCEPT CUSTOM DESIGNED STARTERS SUCH AS THOSE PHYSICALLY MOUNTED ON THE UNIT OR ANY PIECE OF EQUIPMENT WHERE STARTER IS FURNISHED AS AN INTEGRAL PART OF THE EQUIPMENT. 3. THERMOSTAT AND SPECIAL WIRE OTHER THAN BUILDING WIRE. THERMOSTAT AND SPECIAL WIRE OTHER THAN BUILDING WIRE. PART 3 - EXECUTION 3.1 INSTALLATION - GROUNDING AND BONDING A. PROVIDE BONDING AND GROUNDING IN CONFORMANCE WITH NFPA 70. PROVIDE BONDING AND GROUNDING IN CONFORMANCE WITH NFPA 70. B. EQUIPMENT GROUNDING CONDUCTOR: PROVIDE SEPARATE, INSULATED CONDUCTOR WITHIN EACH EQUIPMENT GROUNDING CONDUCTOR: PROVIDE SEPARATE, INSULATED CONDUCTOR WITHIN EACH FEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG, BUS, OR BUSHING. 3.2 INSTALLATION - HANGERS AND SUPPORTS A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS. B. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT, AND CONDUIT. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT, AND CONDUIT. C. DO NOT USE SPRING STEEL CLIPS AND CLAMPS. DO NOT USE SPRING STEEL CLIPS AND CLAMPS. D. DO NOT USE POWDER-ACTUATED ANCHORS. DO NOT USE POWDER-ACTUATED ANCHORS. E. OBTAIN PERMISSION FROM BUILDING STRUCTURAL ENGINEER BEFORE DRILLING OR CUTTING OBTAIN PERMISSION FROM BUILDING STRUCTURAL ENGINEER BEFORE DRILLING OR CUTTING STRUCTURAL MEMBERS. F. FABRICATE SUPPORTS FROM STRUCTURAL STEEL ANGLE OR STRUCTURAL STEEL CHANNEL. FABRICATE SUPPORTS FROM STRUCTURAL STEEL ANGLE OR STRUCTURAL STEEL CHANNEL. RIGIDLY WELD MEMBERS OR USE HEXAGON HEAD BOLTS TO PRESENT NEAT APPEARANCE WITH ADEQUATE STRENGTH AND RIGIDITY. USE SPRING LOCK WASHERS UNDER ALL NUTS. G. INSTALL SURFACE-MOUNTED CABINETS AND PANELS WITH MINIMUM OF FOUR ANCHORS. INSTALL SURFACE-MOUNTED CABINETS AND PANELS WITH MINIMUM OF FOUR ANCHORS. H. IN WET AND DAMP LOCATIONS USE STRUCTURAL STEEL CHANNEL SUPPORTS TO STAND CABINETS IN WET AND DAMP LOCATIONS USE STRUCTURAL STEEL CHANNEL SUPPORTS TO STAND CABINETS AND PANELBOARDS ONE INCH OFF WALL. 3.3 INSTALLATION - CONDUCTORS AND CABLES A. WIRING METHODS: WIRING METHODS: 1. CONCEALED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION IN CONCEALED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION IN EMT, FMC, OR RGS METALLIC RACEWAY. 2. EXPOSED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION IN EXPOSED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION IN EMT, FMC, OR LFMC. PROVIDE RGS WHERE EXPOSED TO MECHANICAL DAMAGE. 3. WET OR DAMP INTERIOR AND EXTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THWN WET OR DAMP INTERIOR AND EXTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THWN INSULATION IN RGS, LFMC, OR PVC. 4. MINIMUM RACEWAY SIZE IS 3/4" DIAMETER. MINIMUM RACEWAY SIZE IS 3/4" DIAMETER. 5. BELOW GRADE: USE ONLY BUILDING WIRE TYPE THHN/THWN INSULATION IN PVC SCHEDULE 40 BELOW GRADE: USE ONLY BUILDING WIRE TYPE THHN/THWN INSULATION IN PVC SCHEDULE 40 RACEWAY. B. USE SOLID COPPER CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS #10 AWG AND SMALLER. USE SOLID COPPER CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS #10 AWG AND SMALLER. USE STRANDED COPPER CONDUCTORS FOR #8AWG AND LARGER CONDUCTORS. C. USE STRANDED COPPER CONDUCTORS FOR CONTROL CIRCUITS AND FINAL CONNECTIONS TO ALL USE STRANDED COPPER CONDUCTORS FOR CONTROL CIRCUITS AND FINAL CONNECTIONS TO ALL VIBRATION EQUIPMENT. D. USE CONDUCTOR NOT SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS. USE CONDUCTOR NOT SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS. E. USE CONDUCTOR NOT SMALLER THAN 14 AWG FOR CONTROL CIRCUITS. USE CONDUCTOR NOT SMALLER THAN 14 AWG FOR CONTROL CIRCUITS. F. USE 10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 USE 10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. G. PULL ALL CONDUCTORS INTO RACEWAY AT SAME TIME. PULL ALL CONDUCTORS INTO RACEWAY AT SAME TIME. H. USED APPROVED WIRE PULLING LUBRICANT FOR ALL BUILDING WIRE. USED APPROVED WIRE PULLING LUBRICANT FOR ALL BUILDING WIRE. I. PROTECT EXPOSED CABLE FROM DAMAGE. PROTECT EXPOSED CABLE FROM DAMAGE. J. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. K. CLEAN CONDUCTOR SURFACES BEFORE INSTALLING LUGS AND CONNECTORS. CLEAN CONDUCTOR SURFACES BEFORE INSTALLING LUGS AND CONNECTORS. L. MAKE SPLICES, TAPS, AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITH NO MAKE SPLICES, TAPS, AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITH NO PERCEPTIBLE TEMPERATURE RISE. M. USE SOLDER LESS PRESSURE COMPRESSION CONNECTORS WITH INSULATING COVERS FOR COPPER USE SOLDER LESS PRESSURE COMPRESSION CONNECTORS WITH INSULATING COVERS FOR COPPER CONDUCTOR SPLICES AND TAPS, 8 AWG AND SMALLER. N. USE CONDUCTORS RATED 90 DEGREES C, INSIDE A BALLAST COMPARTMENT OR WITHIN 6 INCHES USE CONDUCTORS RATED 90 DEGREES C, INSIDE A BALLAST COMPARTMENT OR WITHIN 6 INCHES OF ANY BALLAST. 3.4 INSTALLATION - RACEWAYS AND BOXES A. INSTALL NONMETALLIC CONDUIT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INSTALL NONMETALLIC CONDUIT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. CONDUIT AND CABLE ROUTING PATHS INDICATED ON DRAWINGS ARE APPROXIMATE LOCATIONS CONDUIT AND CABLE ROUTING PATHS INDICATED ON DRAWINGS ARE APPROXIMATE LOCATIONS UNLESS DIMENSIONED. ROUTE PARALLEL AND PERPENDICULAR TO BUILDING CONSTRUCTION FOR COMPLETE WIRING SYSTEM REGARDLESS WHETHER EXPOSED OR CONCEALED. C. ARRANGE SUPPORTS TO PREVENT MISALIGNMENT DURING WIRING INSTALLATION. ARRANGE SUPPORTS TO PREVENT MISALIGNMENT DURING WIRING INSTALLATION. D. GROUP RELATED CONDUITS AND CABLES; SUPPORT USING APPROVED CONNECTORS. GROUP RELATED CONDUITS AND CABLES; SUPPORT USING APPROVED CONNECTORS. E. FASTEN CONDUIT SUPPORTS TO BUILDING STRUCTURE AND SURFACES UNDER PROVISIONS OF FASTEN CONDUIT SUPPORTS TO BUILDING STRUCTURE AND SURFACES UNDER PROVISIONS OF THIS SECTION. F. DO NOT SUPPORT CONDUIT OR CABLE WITH WIRE OR PERFORATED PIPE STRAPS IN ANY TYPE DO NOT SUPPORT CONDUIT OR CABLE WITH WIRE OR PERFORATED PIPE STRAPS IN ANY TYPE STRUCTURE. REMOVE WIRE USED FOR TEMPORARY SUPPORTS. STEEL TIE WIRE MAY BE USED TO ANCHOR CONDUIT DOWN TO REINFORCING RODS IN CONCRETE ENCASEMENT ONLY. G. DO NOT ATTACH CONDUIT OR CABLE TO CEILING SUPPORT WIRES. DO NOT ATTACH CONDUIT OR CABLE TO CEILING SUPPORT WIRES. H. ARRANGE CONDUIT AND CABLE TO MAINTAIN HEADROOM AND PRESENT NEAT APPEARANCE. ARRANGE CONDUIT AND CABLE TO MAINTAIN HEADROOM AND PRESENT NEAT APPEARANCE. I. ROUTE ALL CONDUIT AND CABLE WHETHER EXPOSED OR CONCEALED PARALLEL AND ROUTE ALL CONDUIT AND CABLE WHETHER EXPOSED OR CONCEALED PARALLEL AND PERPENDICULAR TO WALLS, CEILINGS, BUILDING STRUCTURES, ETC. J. MAINTAIN REQUIRED CLEARANCE BETWEEN CONDUIT/CABLE, AND PIPING. MAINTAIN REQUIRED CLEARANCE BETWEEN CONDUIT/CABLE, AND PIPING. K. MAINTAIN 12 INCH CLEARANCE BETWEEN CONDUIT/CABLE AND SURFACES WITH TEMPERATURES MAINTAIN 12 INCH CLEARANCE BETWEEN CONDUIT/CABLE AND SURFACES WITH TEMPERATURES EXCEEDING 104 DEGREES F. L. CUT EMT CONDUIT SQUARE USING SAW OR PIPECUTTER; DE-BURR CUT ENDS AND REAM. CUT EMT CONDUIT SQUARE USING SAW OR PIPECUTTER; DE-BURR CUT ENDS AND REAM. M. BRING CONDUIT TO SHOULDER OF FITTINGS; FASTEN SECURELY. BRING CONDUIT TO SHOULDER OF FITTINGS; FASTEN SECURELY. N. USE CONDUIT HUBS OR SEALING LOCKNUTS TO FASTEN CONDUIT TO SHEET METAL BOXES IN USE CONDUIT HUBS OR SEALING LOCKNUTS TO FASTEN CONDUIT TO SHEET METAL BOXES IN DAMP AND WET LOCATIONS AND TO CAST BOXES. O. INSTALL NO MORE THAN EQUIVALENT OF THREE 90-DEGREE BENDS BETWEEN BOXES. USE INSTALL NO MORE THAN EQUIVALENT OF THREE 90-DEGREE BENDS BETWEEN BOXES. USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS. P. AVOID MOISTURE TRAPS; PROVIDE JUNCTION BOX WITH DRAIN FITTING AT LOW POINTS IN AVOID MOISTURE TRAPS; PROVIDE JUNCTION BOX WITH DRAIN FITTING AT LOW POINTS IN CONDUIT SYSTEM. Q. PROVIDE SUITABLE FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE CONDUIT PROVIDE SUITABLE FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE CONDUIT CROSSES CONTROL AND EXPANSION JOINTS. R. PROVIDE SUITABLE NYLON PULL STRING OR #14 AWG STEEL WIRE IN EACH CONDUIT EXCEPT PROVIDE SUITABLE NYLON PULL STRING OR #14 AWG STEEL WIRE IN EACH CONDUIT EXCEPT SLEEVES AND NIPPLES. S. USE SUITABLE CAPS TO PROTECT INSTALLED CONDUIT AGAINST ENTRANCE OF DIRT AND USE SUITABLE CAPS TO PROTECT INSTALLED CONDUIT AGAINST ENTRANCE OF DIRT AND MOISTURE. T. GROUND AND BOND CONDUIT PER NFPA 70 GROUND AND BOND CONDUIT PER NFPA 70 U. COAT ALL METALLIC CONDUIT MALE THREADS WITH “GENERAL ELECTRIC” RTV SILICONE SEALER COAT ALL METALLIC CONDUIT MALE THREADS WITH “GENERAL ELECTRIC” RTV SILICONE SEALER GENERAL ELECTRIC” RTV SILICONE SEALER RTV SILICONE SEALER WHERE CONDUIT IS INSTALLED IN EXTERIOR AREAS OR IN CONTACT WITH CONCRETE OR EARTH. V. CONDUITS SIZED AS INDICATED ON DRAWINGS. WHERE SIZE NOT INDICTED, SIZE PER NFPA 70. CONDUITS SIZED AS INDICATED ON DRAWINGS. WHERE SIZE NOT INDICTED, SIZE PER NFPA 70. W. CAP ALL UPTURNED CONDUITS DURING CONSTRUCTION ROUGH-IN TO PREVENT MOISTURE OR CAP ALL UPTURNED CONDUITS DURING CONSTRUCTION ROUGH-IN TO PREVENT MOISTURE OR DEBRIS FROM ENTERING. PULL THROUGH EACH AND EVERY CONDUIT A DRY SWAB OF SUFFICIENT SIZE TO REMOVE ANY AND ALL MOISTURE. X. MAXIMUM 6 FOOT LENGTH FLEXIBLE METAL CONDUIT (GREENFIELD), MC CABLE, OR FLEXIBLE MAXIMUM 6 FOOT LENGTH FLEXIBLE METAL CONDUIT (GREENFIELD), MC CABLE, OR FLEXIBLE LIQUIDTITE PERMITTED. Y. ASSURE GROUND CONTINUITY ON ALL BRANCH CIRCUITRY CONDUITS WITH TWO LOCKNUTS, ONE ASSURE GROUND CONTINUITY ON ALL BRANCH CIRCUITRY CONDUITS WITH TWO LOCKNUTS, ONE INSIDE AND ONE OUTSIDE OF ALL BOXES, CABINETS AND GUTTERS FOR RIGID CONDUIT. ONE LOCKNUT INSIDE OF ALL BOXES, CABINETS, AND GUTTERS FOR EMT. AA. INSTALL BOXES IN ACCORDANCE WITH NECA "STANDARD OF INSTALLATION." BB. SET WALL MOUNTED BOXES AT ELEVATION TO ACCOMMODATE MOUNTING HEIGHTS INDICATED OR AS REQUIRED FOR SPECIFIC PROJECT REQUIREMENTS. CC. INACCESSIBLE CEILING AREAS: INSTALL OUTLET AND JUNCTION BOXES NO MORE THAN 6 INCHES FROM CEILING ACCESS PANEL OR FROM REMOVABLE RECESSED LUMINAIRE. ACCESS PANEL OR FROM REMOVABLE RECESSED LUMINAIRE. DD. COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF OUTLETS MOUNTED ABOVE COUNTERS, BENCHES, AND BACKSPLASHES OR FOR HVAC WINDOW UNITS. EE. LOCATE OUTLET BOXES TO ALLOW LUMINARIES POSITIONED AS INDICATED ON DRAWINGS. FF. DO NOT INSTALL FLUSH MOUNTING BOX BACK-TO-BACK IN WALLS; PROVIDE MINIMUM 6 INCHES SEPARATION. GG. SECURE FLUSH MOUNTING BOX TO INTERIOR WALL AND PARTITION STUDS. ACCURATELY POSITION TO ALLOW FOR SURFACE FINISH THICKNESS. HH. USE APPROVED STAMPED STEEL BRACKETS TO FASTEN FLUSH MOUNTING OUTLET BOX BETWEEN STUDS. II. INSTALL FLUSH MOUNTING BOX WITHOUT DAMAGING WALL INSULATION OR REDUCING ITS EFFECTIVENESS. JJ. USE APPROVED ADJUSTABLE STEEL CHANNEL FASTENERS SPANNING JOIST FOR HUNG CEILING OUTLET BOX. KK. DO NOT FASTEN BOXES TO CEILING SUPPORT WIRES. LL. SUPPORT BOXES INDEPENDENTLY OF CONDUIT. 3.9 INSTALLATION - WIRING DEVICES. A. INSTALL DEVICES PLUMB AND LEVEL. B. INSTALL RECEPTACLES WITH GROUNDING POLE ON BOTTOM. C. CONNECT WIRING DEVICE GROUNDING TERMINAL TO BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTOR. D. CONNECT WIRING DEVICES BY WRAPPING CONDUCTOR 2/3 OF SCREW DIAMETER IN CLOCKWISE DIRECTION AROUND SCREW TERMINAL. DO NOT USE SPRING PRESSURE DEVICES FOR WIRE CONNECTIONS. END OF SECTION 16000 END OF SECTION 16000
AutoCAD SHX Text
E-3
07/20/20
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
EXISTING CONSTRUCTION
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
SN2
AutoCAD SHX Text
SN2
AutoCAD SHX Text
SN2
AutoCAD SHX Text
SN2
AutoCAD SHX Text
SN2
AutoCAD SHX Text
SN2
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
DEMO PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
%%UELECTRICAL - DEMOLITION PLAN
AutoCAD SHX Text
SHEET NOTES: SN1 CIRCUITS CONNECTED TO REMOVED DEVICES TO BE REUSED IN NEW CONFIGURATION. CONNECT NEW DEVICES SHOWN ON POWER AND LIGHTING PLAN TO EXISTING CIRCUITS. SN2 FAN COIL UNIT TO BE RELOCATED. EXTEND EXISTING CIRCUIT TO NEW LOCATION AND RECONNECT.
AutoCAD SHX Text
E-4
07/20/20
AutoCAD SHX Text
JUDGE'S
AutoCAD SHX Text
CHAMBER
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
JURY ROOM
AutoCAD SHX Text
COURTROOM
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
COURTROOM
AutoCAD SHX Text
BAILIFF
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATT.
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
EXERCISE
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LAW
AutoCAD SHX Text
LIBRARY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
JUVENILE
AutoCAD SHX Text
RECORD
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
VISITATION
AutoCAD SHX Text
HOLDING/
AutoCAD SHX Text
CHAMBER
AutoCAD SHX Text
JUDGE'S
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
THIS AREA TO RECEIVE
AutoCAD SHX Text
NEW WAINSCOTING
AutoCAD SHX Text
ROOF ACCESS
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
ROOF HATCH
AutoCAD SHX Text
AND ACCESS
AutoCAD SHX Text
LADDER
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
101
AutoCAD SHX Text
102
AutoCAD SHX Text
103
AutoCAD SHX Text
104
AutoCAD SHX Text
105
AutoCAD SHX Text
107
AutoCAD SHX Text
VISITATION
AutoCAD SHX Text
HOLDING/
AutoCAD SHX Text
106
AutoCAD SHX Text
108
AutoCAD SHX Text
109
AutoCAD SHX Text
110
AutoCAD SHX Text
111
AutoCAD SHX Text
112
AutoCAD SHX Text
01
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
D
AutoCAD SHX Text
F
AutoCAD SHX Text
A
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
A1
AutoCAD SHX Text
A1
AutoCAD SHX Text
A1
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
NE
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
D-1
AutoCAD SHX Text
D-1
AutoCAD SHX Text
D-1
AutoCAD SHX Text
D-3
AutoCAD SHX Text
D-5
AutoCAD SHX Text
D-2
AutoCAD SHX Text
D-2
AutoCAD SHX Text
D-2
AutoCAD SHX Text
D-2
AutoCAD SHX Text
D-7
AutoCAD SHX Text
D-7
AutoCAD SHX Text
D-7
AutoCAD SHX Text
D-7
AutoCAD SHX Text
D-7
AutoCAD SHX Text
D-7
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
SN3
AutoCAD SHX Text
D
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
LIGHTING PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
%%UELECTRICAL - LIGHTING PLAN
AutoCAD SHX Text
SHEET NOTES: SN1 CIRCUIT NUMBERS SHOWN ARE EXISTING CIRCUITS IN PANEL D WHICH PREVIOUSLY POWERED LIGHTING/DEVICES IN THE AREA SHOWN. CONNECT TO THESE EXISTING CIRCUITS. SN2 COORDINATE DEVICE INSTALLATION WITH ARCHITECTURAL COORDINATE DEVICE INSTALLATION WITH ARCHITECTURAL CASEWORK. SN3 CONNECT TO ROOM LIGHTSCONNECT TO ROOM LIGHTS
AutoCAD SHX Text
E-5
07/20/20
AutoCAD SHX Text
JUDGE'S
AutoCAD SHX Text
CHAMBER
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
JURY ROOM
AutoCAD SHX Text
COURTROOM
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
COURTROOM
AutoCAD SHX Text
BAILIFF
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATT.
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
EXERCISE
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
ATTORNEY'S
AutoCAD SHX Text
LAW
AutoCAD SHX Text
LIBRARY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
JUVENILE
AutoCAD SHX Text
RECORD
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
HOLDING
AutoCAD SHX Text
VISITATION
AutoCAD SHX Text
HOLDING/
AutoCAD SHX Text
CHAMBER
AutoCAD SHX Text
JUDGE'S
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text
THIS AREA TO RECEIVE
AutoCAD SHX Text
NEW WAINSCOTING
AutoCAD SHX Text
ROOF ACCESS
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
ROOF HATCH
AutoCAD SHX Text
AND ACCESS
AutoCAD SHX Text
LADDER
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
101
AutoCAD SHX Text
102
AutoCAD SHX Text
103
AutoCAD SHX Text
104
AutoCAD SHX Text
105
AutoCAD SHX Text
107
AutoCAD SHX Text
VISITATION
AutoCAD SHX Text
HOLDING/
AutoCAD SHX Text
106
AutoCAD SHX Text
108
AutoCAD SHX Text
109
AutoCAD SHX Text
110
AutoCAD SHX Text
111
AutoCAD SHX Text
112
AutoCAD SHX Text
01
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
D
AutoCAD SHX Text
G,A
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
TV
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
TV
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
TV
AutoCAD SHX Text
A
AutoCAD SHX Text
D-37
AutoCAD SHX Text
D-37
AutoCAD SHX Text
D-15
AutoCAD SHX Text
D-41
AutoCAD SHX Text
D-15
AutoCAD SHX Text
D-15
AutoCAD SHX Text
D-41
AutoCAD SHX Text
D-15
AutoCAD SHX Text
D-17
AutoCAD SHX Text
D-41
AutoCAD SHX Text
D-17
AutoCAD SHX Text
D-17
AutoCAD SHX Text
D-19
AutoCAD SHX Text
B-41
AutoCAD SHX Text
B-39
AutoCAD SHX Text
SN7
AutoCAD SHX Text
SN7
AutoCAD SHX Text
SN7
AutoCAD SHX Text
SN7
AutoCAD SHX Text
SN7
AutoCAD SHX Text
SN7
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
POWER PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
%%UELECTRICAL - POWER PLAN
AutoCAD SHX Text
SHEET NOTES: SN1 CIRCUIT NUMBERS SHOWN ARE EXISTING CIRCUITS IN PANEL D WHICH PREVIOUSLY POWERED LIGHTING/DEVICES IN THE AREA SHOWN. CONNECT TO THESE EXISTING CIRCUITS. SN2 SOUND EQUIPMENT AND INSTALLATION BY OWNER. COORDINATE WITH SOUND EQUIPMENT AND INSTALLATION BY OWNER. COORDINATE WITH OWNER TO LEAVE ROOM IN CASEWORK FOR MICROPHONE AT BENCH, CLERK STATION, ATTORNEY TABLES, AND WITNESS STAND. SN3 COORDINATE DEVICE INSTALLATION WITH ARCHITECTURAL CASEWORK. COORDINATE DEVICE INSTALLATION WITH ARCHITECTURAL CASEWORK. SN4 TIE NEW FIRE ALARM DEVICE(S) INTO EXISTING FA SYSTEM. TIE NEW FIRE ALARM DEVICE(S) INTO EXISTING FA SYSTEM. SN5 SECURITY SYSTEM/ALARM BY OWNER. COORDINATE WITH OWNER TO SECURITY SYSTEM/ALARM BY OWNER. COORDINATE WITH OWNER TO LEAVE ROOM IN CASEWORK FOR SILENT ALARM AT BENCH AND CLERK STATION. SN6 CONNECT FLOOR RECEPTACLES TO SPARE CIRCUIT IN PANEL B CONNECT FLOOR RECEPTACLES TO SPARE CIRCUIT IN PANEL B LOCATED ON THE FIRST FLOOR. SN7 RELOCATED FAN COIL UNIT. EXTEND EXISTING CIRCUIT TO NEW RELOCATED FAN COIL UNIT. EXTEND EXISTING CIRCUIT TO NEW LOCATION AND RECONNECT UNIT.
AutoCAD SHX Text
E-6
07/20/20
AutoCAD SHX Text
COMM. NO.
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
(540)980-2429
AutoCAD SHX Text
159 FOURTH STREET,NW
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
THOMAS A. DOUTHAT , JR.
AutoCAD SHX Text
2015-A-725
AutoCAD SHX Text
TAD
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ALTERATIONS FOR
AutoCAD SHX Text
PULASKI COUNTY COURTHOUSE
AutoCAD SHX Text
45 THIRD STREET , NW
AutoCAD SHX Text
PULASKI , VIRGINIA
AutoCAD SHX Text
6-01-2015
AutoCAD SHX Text
7
AutoCAD SHX Text
SCHEDULE AND DETAILS
AutoCAD SHX Text
LIGHT SWITCH(S)
AutoCAD SHX Text
RECEPTACLE,
AutoCAD SHX Text
TELEPHONE OR
AutoCAD SHX Text
COMPUTER/DATA
AutoCAD SHX Text
OUTLETS
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
(DOOR)
AutoCAD SHX Text
15" MIN
AutoCAD SHX Text
DOOR FRAME
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
%%uDETAIL - TYPICAL OUTLET BOX ELEVATIONS
AutoCAD SHX Text
CL
AutoCAD SHX Text
4"
AutoCAD SHX Text
CL
AutoCAD SHX Text
THERMOSTAT OR OTHER
AutoCAD SHX Text
MECHANICAL SWITCH
AutoCAD SHX Text
F
AutoCAD SHX Text
4"
AutoCAD SHX Text
48" MAX TO CENTER OF SWITCH
AutoCAD SHX Text
OR FIRE ALARM PULL STATION
AutoCAD SHX Text
6'-8" TO BOTTOM OF FIRE ALARM AUDIBLE
AutoCAD SHX Text
OR AUDIBLE/VISUAL DEVICE. LIGHT SOURCE
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
6" ABOVE DOOR FRAME OR CENTERED
AutoCAD SHX Text
BETWEEN DOOR FRAME & CEILING
AutoCAD SHX Text
THERMOSTAT OR MECH SWITCH
AutoCAD SHX Text
4"
AutoCAD SHX Text
SHALL BE 80" AFF MINIMUM.
AutoCAD SHX Text
OUTLET BOX DETAIL NOTES: : 1. WHERE MULTIPLE SWITCHES ARE USED, PROVIDE MULTIPLE WHERE MULTIPLE SWITCHES ARE USED, PROVIDE MULTIPLE GANG BOXES AS REQUIRED UP TO SIX GANGS. FOR GREATER NUMBER OF SWITCHES OR LIGHT CONTROL DIMMERS, USE ADDITIONAL ROWS AT 8" LOWER HEIGHT. DIVIDE MULTIPLE SWITCHES EVENLY, FOR MATCHING BOX GANGS. 2. FOR DIMMER, DERATE AND PROVIDE SPACING AS FOR DIMMER, DERATE AND PROVIDE SPACING AS RECOMMENDED BY THE MANUFACTURER. 3. RECEPTACLES AND OTHER OUTLETS SHALL ALIGN VERTICALLY RECEPTACLES AND OTHER OUTLETS SHALL ALIGN VERTICALLY WITH LIGHT SWITCHES AND OTHER DEVICES MOUNTED ABOVE. 4. RECEPTACLES SHOWN AT 48" HEIGHT MAY BE INCORPORATED RECEPTACLES SHOWN AT 48" HEIGHT MAY BE INCORPORATED INTO SAME SWITCHPLATE WITH LIGHT SWITCH. 5. RECEPTACLES AND OTHER OUTLETS AT SAME ELEVATION RECEPTACLES AND OTHER OUTLETS AT SAME ELEVATION SHOWN SIDE BY SIDE ON PLANS SHALL BE MOUNTED 4" APART IN WALL UNLESS OTHERWISE REQUIRED BY FIRE ASSEMBLY DETAILS.