Camp del"arpa Ecotect Analysis

Preview:

DESCRIPTION

An environmental analysis of this area in the city of Barcelona, to help develop the Zero Emissions Project.

Citation preview

CAMPDE

L’ARPACA

ROLIN

A LIB

ARDI

_ECO

TECT

[201

0]EN

VIRO

NMEN

TAL A

NALY

SIS

[the

area

]Zero emissions Project

The Institute of Advanced Archi-tecture of Catalonia is involved in a research project to transform the city of Barcelona in a Zero Emission city. The barrio of Camp del’Arpa, located in the northeast part of the territory, was analysed using the Ecotect tool, and the results will be used in the future proposal for the region.

Camp del’Arpa - Barcelona

Barr

io 5

steP 1:Model the area in a 3D modeling program In this case, Rhinoceros was used.

the

mod

el

steP 2:Exporting the 3D Model from Rhinoceros. Select All > File > Export as DXF

the

mod

el

steP 3:Import the model in Ecotect. Scale 1 X 1 - Meters to Millimiters. Save As in the hard drive.

the

mod

el

steP 4:Click the Visualize tab to see the 3D Model imported. Go to Modify > Merge Coincident Triangles to optimize the analysis.

the

mod

el

steP 5:Go to Modify Model Settings to put the north in the right position.

the

mod

el

steP 6:Click the world in the top toolbar to load the weather file for the specific location.

the

proc

ess

steP 7:Go to the Shadows tab on the right box and select Display Shadows [Daily]

the

proc

ess

steP 8:Check the Anual Sun Path case to create the following diagram.

the

proc

ess

steP 9:Click the Show Sahdow Range button to create a digram of the shadow range for the hole year.

the

proc

ess

steP 10:Choose a surface to analyse the solar incidence. Copy the plans in a new layer, or New Zone, to facilitate the visualization.

the

proc

ess

steP 11:Go to Display > Normals to check the direction of the normals vectors. In case they are in the wrong direction, go to Modify > Reverse Normals.

the

proc

ess

steP 12:Go to Modify > Surface Subdivision to create a grid in the surface that will be analysed. Check the cases as shown in the image above.

the

proc

ess

steP 13:Assign the material that is being used in the surface in the Material Assignment Tab at the right. Right click on the desired material to apply it to the selection.

the

proc

ess

steP 14:Go to Calculate > Solar Access Analysis and follow the wizard instructions.

the

proc

ess

steP 15:After the software finishes the calculations, the result should be a diagram as the above.

the

proc

ess

steP 16:The solar analysis of the hole area can ba achieved by creating a grid that contains the totality of the buildings. Go to the Grid tab on the right to manage the Grid.

the

proc

ess

steP 17:Go to Calculate > Solar Acces Analysis and calculate it for the grid that was created.

the

proc

ess

steP 18:To perform the Spatial Visibility Analysis you should define a grid in the analysed area through th Adjust Grid Extends com-mand and then Manually Adjust Grid Extends. After that, select the surface that will be analysed (selected in red).

the

proc

ess

steP 19:To start the wind analysis a Winair file had to be loaded in Preferences > General > 3rd Party Tools > Winair4 Application. After that you hac=ve to Fit Grid to Objects > Calculate CFD Cell Blockages > Export to Winair4 > Save > Insert Param-eters for the Export > Load CFD Data.

the

proc

ess

steP 20:The Wind Analysis diagram.

the

proc

ess

steP 21:Changing the option shown in the right hand side toolbar, we can obtain the Cell Temperature Analysis diagram.

the

proc

ess

steP 22:Changing the option shown in the right hand side toolbar, we can obtain the Air Flow Rate Analysis diagram.

the

proc

ess

steP 23:Changing the option shown in the right hand side toolbar, we can obtain the Cell Pressure Analysis diagram.

the

proc

ess

CAMPDEL’ARPA

CAROLINA LIBARDI

_ECOTECT [2010]