View
122
Download
4
Category
Tags:
Preview:
DESCRIPTION
Atlantium Advantage Hydro-Optic Disinfection The “Future” Of Disinfection. Atlantium Advantage 2007. Who Are We?. Worldwide Leader Next Generation Water Disinfection Solutions. Revolutionary Disinfection Technology Hydro-Optic Disinfection (HOD): Environmentally friendly - PowerPoint PPT Presentation
Citation preview
Atlantium AdvantageHydro-Optic Disinfection
The “Future” Of Disinfection
Atlantium Advantage 2007
2
Who Are We?Who Are We?
Worldwide Leader
Next Generation
Water Disinfection Solutions
Revolutionary Disinfection Technology
Hydro-Optic Disinfection (HOD): Environmentally friendly Simple to use and maintain At a low cost of ownership Guaranteed performance…
3
Atlantium Advantage… Red Herring’s List: “Companies Driving the Future of Technology”
Atlantium Advantage… Red Herring’s List: “Companies Driving the Future of Technology”
4
Water Disinfection Technologies TodayWater Disinfection Technologies Today
Extremely high operational & maintenance costsReliable; Wide acceptance
Heat exchange Heat exchange (pasteurization) (pasteurization)
IssuesAdvantages
Microbial Kill 1-3 log range; Deposits & fouling of quartz sleeves; High maintenance; Questionable reliability; Issues with monitoring and control
Environmentally Friendly;Acceptable
Conventional Conventional UVUV
Expensive to buy & operate; Stops microbes only above certain threshold; Sensitive to chlorine; Backwash treatment and bio-films breed hidden costs over time
Reliable;Wide acceptanceMembranesMembranes
Disinfection by-products (Bromates); Hard to control with water quality flux; Difficult working environment; Lots of hidden costs
Effective;Accepted for some industries
OzonationOzonation
Disinfection by-products; Taste in food; Ineffective against Cryptosporidium & Giardia; Creates issues for downstream processing - membranes
Relatively cheap; Widely used and accepted
ChlorinationChlorination
5
What is the big news about HOD?What is the big news about HOD?
Great solutions are simple solutions
Conceptual change in conventional thinking…
““Light inside the Water”Light inside the Water”
““Water inside the LightWater inside the Light ” ”
6
Conventional UV Conventional UV
Microbial EscapeRoutes
Many Lamps; Non-Uniform Light Distribution
7
Same principle as in optical fibers: “Total Internal Reflection”
No microbial escape routesNo lamp fouling due to scale from heatNo mechanical cleaners to jam & maintainNo mercury in the water from broken lamps
HOD Technology Principle“The liquid wave guide”
HOD Technology Principle“The liquid wave guide”
9
HOD’s Out-of-the-Box DesignHOD’s Out-of-the-Box Design
Light beams represent how the fiber optic Total Internal Reflection principle works
11
2
3 3
4
Out-of-the-water light sources1
Air cooled dry chamber2
Dual sensor configuration for accurate monitoring3
Central quartz chamber traps light photons4
10
Operation PrinciplesOperation Principles
HOD System Cross SectionHOD System Cross SectionHOD System Cross SectionHOD System Cross Section
Quartz Window
“Lamp Status” Monitoring
Sensor
“Dose Control”Transmission
Sensor
AIR
AIR
AIR
AIR
WATER
* Medium Pressure High Intensity
Air Cooling
Quartz Tube
Air BlockMPHI* UV
Light Source
Reflector
11
The Atlantium “Total Kill” Solution HOD vs. Sea Water Algae; NO Recovery
The Atlantium “Total Kill” Solution HOD vs. Sea Water Algae; NO Recovery
11
Dark Chamber Natural Environment
28 Days Incubation
A - Inlet B - Outlet
12
The HOD Advantage I: Performance & ReliabilityThe HOD Advantage I: Performance & Reliability
HOD System HOD System HOD System HOD System
WATER
Conventional UV Conventional UV Conventional UV Conventional UV
Heat = Sleeve Deposits Requires Frequent Maintenance
Uniform Dose Distribution
Non-Uniform Dose Distribution
13
HOD System HOD System HOD System HOD System
WATER
5 Minutes Replacement No System Downtime
Cumbersome lamp & sleeve replacementSystem Down & Off-Line
Broken LampsMercury & Glass Contamination
The HOD Advantage II: Simple MaintenanceThe HOD Advantage II: Simple Maintenance
Conventional UV Conventional UV Conventional UV Conventional UV
14
WATER
Conventional UV Conventional UV Conventional UV Conventional UV Indirect UV Light Measurement(Through Water & Sleeve Fouling)
Direct UV Source Measurement
Additional UVT InstrumentAssures Delivered Dose
The HOD Advantage III: Monitoring & ControlThe HOD Advantage III: Monitoring & Control
HOD System HOD System HOD System HOD System
15
HOD Performance ValidationDeveloped Dose = Delivered DoseHOD Performance ValidationDeveloped Dose = Delivered Dose
Accurate Monitoring On-line UVT Monitoring
Uniform Dose Distribution(No “Low Dose” Tracks)
Validated Dose = Displayed Dosey = 0.9973x
R2 = 0.9984
75.0
80.0
85.0
90.0
95.0
100.0
75.00 85.00 95.00
UVT by Spectrophotometer (%)
UV
T b
y H
OD
(%
)
On-line Lamp Monitoring
0.0
20.0
40.0
60.0
80.0
100.0
0 20 40 60 80 100
Power Level (%)
Se
nso
r b
y H
OD
(%
) Sensor1-Lamp1
Sensor2-Lamp2
U(D
)
UV-Dose [mJ/cm^2]
0
0.02
0.04
0.06
0.08
0.1
0.12
0 50 100 150 200
Dose DistributionAverage track DoseMinimal Dose
Dose DistributionAverage TrackMinimum Dose
y = 1.0021x - 1.1438
R2 = 0.97060
20
40
60
80
100
120
140
0 20 40 60 80 100 120 140
RED calculated - Rev 3.2
RE
D m
ea
su
red
EP
A
Va
lid
ati
on
Reduction Equivalent Dose Verified: R200-DL What you see is what you get
What you get is what you need
What you need is what you want
16
The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control
State-Of-The-Art
Set-Up
Control
Monitoring
State-Of-The-Art
Set-Up
Control
Monitoring
17
The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control
Configurable Validated Dose
Configurable Validated Dose
18
The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control
AutomatedReport
Generation
AutomatedReport
Generation
19
Overview:Markets & ProductsOverview:Markets & Products
R – Series: Flow Rates 10 – 300 m3/Hr (~50 – 1500 GPM)
Products-In-Pipeline: Q1, 2007:
R – 500 R - 25
Q3, 2007: R - 1000
Industrial and Municipal markets:
Municipal Drinking Water Water Re-Use Desalination Waste Water
Industrial Food & Beverage Aquaculture Power Plants Pharmaceuticals Other
20
Product WaterProduct Water
Fire-WallFire-Wall Process Water Process Water
PasteurizationPasteurization
The Atlantium AdvantageIndustrial Market Applications
The Atlantium AdvantageIndustrial Market Applications
AquacultureAquaculture
Ultra-Pure / AOP Ultra-Pure / AOP
21
HOD “FireWall” TechnologyIdeal “Solution Solution”: Food & Beverage industryHOD “FireWall” TechnologyIdeal “Solution Solution”: Food & Beverage industry
Inactivate Harmful Microorganisms
Improve Plant Water QualityImproved Product QualityEnhanced HAACP & QA/QC
Minimize Chemicals Use Avoid DBP’s Minimize Risk / Exposure
Saves Power, Chemical & Labor Costs
ROI < One Year
22
“HOD FireWall” Protection:TNUVA E.T. – One of the World’s Largest Dairies“HOD FireWall” Protection:TNUVA E.T. – One of the World’s Largest Dairies
3 x 100 m3/hr Atlantium HOD Units
External View of Atlantium’s Facility
Note Far Sampling point – 500 m’ down the line from the HOD system
Microbial contamination in test points of water system (June - July, 2005)
21.0717.0710.0730.06 4.0723.06 27.0619.0614.069.065.062.06 24.07 27.071.00E+00
1.00E+01
1.00E+02
1.00E+03
1.00E+04
1.00E+05
1.00E+06
Date of test
CF
U/1m
l
System entrance
System exit
Far sampling point
Microbial contamination in test point of dairy water systemMicrobial contamination in test point of dairy water system
23
The Atlantium AdvantageReplace Heat Pasteurization
The Atlantium AdvantageReplace Heat Pasteurization
Above: Conventional Pasteurization UnitAbove: Conventional Pasteurization UnitDown: Atlantium’s HOD PR-20 SystemDown: Atlantium’s HOD PR-20 System
HOD PR-20 System
Validated 9 Log Reduction
Significant “Return On Investment” Energy Savings Reduced Operating Costs Reduced Maintenance Costs
24
Pasteurization:The Atlantium AdvantagePasteurization:The Atlantium Advantage
Conventional PasteurizationConventional PasteurizationAtlantium’s SolutionAtlantium’s Solution
1-1.2 Euro per m³ energy cost0.05 Euro per m³ energy cost
Major maintenance requirementSimple & easy maintenance
Significant system downtimeAlmost no system downtime
Large FootprintSmall Footprint
Return On Investment < 4 Months!Return On Investment < 4 Months!
25
Advanced Oxidation“Super-Charging” HOD Technology
Advanced Oxidation“Super-Charging” HOD Technology
“Super-Charging” HOD Technology
Creation of “radicals-saturated” zone
All water are exposed to “radicals-saturated” zone
Continuous generation of radicals
Utilization of entire HOD reactor’s chamber for chemical reaction
Reduces BOD Loading
Breaks-Down Long Chain Organic Molecules
Cost Effective:
~5ppm Oxidizing Agent
Reduces O&M costs
26
HOD Atlantium Advantage
“Radicals-Saturated” Zone
WATER
“Radicals-Saturated” Zone
Chemical Reaction Zone
OH OH
OHOH
OH
OH
OH OH OHOH
OH
OH
OH
OH
OH
OH
OHOH
OHOH
OxidizerIntroduced
27
HOD vs. Conventional UVAdvantage: Atlantium HOD
HOD vs. Conventional UVAdvantage: Atlantium HOD
WATER
OH
OHOH
OH
OH
OH
OH
OHOH
OHOH
OH
OH OH OH OH OH OHOH OH OH OH OH OH OH OH OH OH OH OH
OH OH OH OH OH OH OH OH OH OH OH OHOH OH OH OH OH OH OH OH
“Uniform Dose”
Ensures reaction within all water flow through the “radicals-saturated” zone
“Uniform Dose”
Ensures reaction within all water flow through the “radicals-saturated” zone
“Dark Routes”
Enables part of water flow to escape the OH radical
formation & contact
“Dark Routes”
Enables part of water flow to escape the OH radical
formation & contact
OH
OH
OH
OHOH
OH
28
The Atlantium AdvantageThe Atlantium Advantage
Unique “Radicals-Saturation Zone” High Generation of OH Radicals Assured Water-To-Radical Contact
Total Fluid Exposure To “Radicals-Saturation Zone” No Escape Routes Uniform Dose
Continuous Generation of Radicals On-Line Lamp Exchange Minimal System Fouling
Huge Chemical-Reaction Chamber Entire HOD Quartz Chamber No Flow Impediments
Applications…
29
Unique AOP OpportunitiesUnique AOP Opportunities
TOC / BOD Reductions
Chlorine / THM Reductions
Complex Compounds Break-Down
Odor Control
Disinfection
Waste Waters Re-Use
Waters Disinfection Ballast Waters System Run-Off
30
AOP / HOD Case Study“Demand Reduction”: Dresden – GermanyAOP / HOD Case Study“Demand Reduction”: Dresden – Germany
AOP / HOD vs. PAC… No Contest!AOP / HOD vs. PAC… No Contest!
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
mg/l
cl-
Free Chlorine 0.39 0.56
Bounded Chlorine 0.29 0.08
Total Chlorine 0.68 0.64
PAC On; HOD Off (15-24/4/2006) PAC Off; HOD On (12-21/6/2006)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
mg/l
cl-
Free Chlorine 0.39 0.56
Bounded Chlorine 0.29 0.08
Total Chlorine 0.68 0.64
PAC On; HOD Off (15-24/4/2006) PAC Off; HOD On (12-21/6/2006)
31
Membrane Pre-Treatment ApplicationsMembrane Pre-Treatment Applications
Protect Membranes…. From Bio-Films Chlorine Break-Through
Task Separation Biologic Firewall Chemical Firewall
Reduce CIP Days Increase Production Decrease Chemical Costs
Increase Membrane Lifetime Extended Run-Times Less Cycling
Reduce Energy Consumption
Return On Investment < One YearReturn On Investment < One Year
32
Atlantium Advantage:Activated Carbon Pre-Application
Atlantium Advantage:Activated Carbon Pre-Application
Active Carbon
UV
Conventional Design: UV Post-GACFor Bacterial Breakout Control
Active Carbon
Atlantium Advantage:HOD Pre-GACPrevent Growth & Fouling
Frequent CIP & Backwash
Frequent Media Replacement
High-Count Excursions
Eliminated by UV
33
Atlantium Advantage:Biofilm Formation In Activated Carbon UnitsAtlantium Advantage:Biofilm Formation In Activated Carbon Units
Atlantium Advantage
Traditional Design
Microbial Break-Through
Periodic CIP
Days
Return On Investment < 2 YearsReturn On Investment < 2 Years
34
The Atlantium AdvantageAquaculture / Fish Hatcheries
The Atlantium AdvantageAquaculture / Fish Hatcheries
Increases fish growth rates
Increases survival rates
Minimizes drugs, chemicals and antibiotics
Improves FCR (Fish Conversion Rate)
Environmentally friendly
35
Case Study:Pinar Fish HatcheryCase Study:Pinar Fish Hatchery
Increase in survival rates: Sea Bream: 100% Sea Bass: 50%
90% Reduction Antibiotic Costs
50% Labor / O&M Costs
ROI: Less Than 4 Months
2nd System Ordered
36
Pinar: Pathogen TestingHOD Technology Provides Documented ResultsPinar: Pathogen TestingHOD Technology Provides Documented Results
Vibrio Count (April – July 2006 '06)
0
500
1000
1500
2000
2500
7.4.
06
14.4
.06
21.4
.06
28.4
.06
5.5.
06
12.5
.06
19.5
.06
26.5
.06
2.6.
06
9.6.
06
16.6
.06
23.6
.06
30.6
.06
7.7.
06
Date
CF
U/m
l
Vibriol Count Outlet Vibrio Count Inlet
37
Further DevelopmentFurther Development
Finalizing EPA Validation Process
Developing “Low-UVT” Reactor
Emerging Markets: Municipal Drinking Water / Ground Water Rule Water Re-Use Power Plants Pharmaceutical Industry Semi–Conductor / Electronic Industry
New Applications: Zebra Mussels Activated Carbon Filter Protection
38
Summary… Atlantium AdvantageSummary… Atlantium Advantage
Leader In Innovative Water Disinfection Solutions: Introducing Hydro-Optic Disinfection (HOD) technology A Revolutionary primary disinfection method
Dozens Of Successful Installations & Applications
Comprehensive Intellectual Property (IP) Portfolio Seasoned management, academic and R&D staff Registered and pending patents worldwide
Operations: Europe, US & Asia – 20 Countries Worldwide
Partnering with reps / distributors and “solution” companies
for sales, installation, support, distribution and R&D projects
39
Most important …Most important …
TheThe
FactorFactor
SleepSleep Well Well
At NightAt Night (SWAN)(SWAN)
Norm Sendler
Atlantium Technologies, Ltd.
888.846.2464
NormS@atlantium.com www.atlantium.com
THANK YOU!