ALPOLIC® & ALPOLIC®/fr
clean rooms
For the building, reconfiguring, or upgrading of cleanrooms and related applications, ALPOLIC® & ALPOLIC®/fr simply can’t
be beat. Available with either fr or standard PE core, ALPOLIC® & ALPOLIC®/fr's flat, clean, non-porous and non-shedding
surface, along with its traditional advantages of high strength to weight ratio, solid durability, and ease of fabrication and
installation make it a very cost-effective material for these highly specialized applications. ALPOLIC® & ALPOLIC®/fr panels
have attracted the positive attention of semiconductor, pharmaceutical, and biotech companies for use in mini-environ-
ments, cleanroom enclosures, cleanroom walls, ceilings, and more. ALPOLIC® & ALPOLIC®/fr panels can be integrated with
framing members, profiles, and accessories supplied by cleanroom manufacturers. ALPOLIC® & ALPOLIC®/fr collaborates
with these high quality firms to provide a complete solution to your specific needs.
S U R FA C E R E S I S T I V I T Y U S I N G A S T M D 2 5 7Conductive - <105 ohmsStatic Dissipative - 105 and 109 ohmsNonconductive - >109 ohms
T O L E R A N C E SWidth: ± 0.08" (± 2mm)Length: ± 0.16" (± 4mm)Thickness:3mm & 4mm: ± 0.008" (± 0.2mm)6mm: ± 0.012" (± 0.3mm)Bow: Maximum 0.5% of length and/or widthSquareness: Maximum 0.2" (5mm)
ALPOLIC® & ALPOLIC®/fr is supplied with factory-cut edges. The panels will not delaminate or release contaminants when cut at the project site.
C O AT I N G P E R F O R M A N C EPropertyCross Cut AdhesionImpact ResistanceFlexibilityTaber AbrasionPencil Hardness
With an emphasis on dependable quality, iden-
tification of field requirements, exceptional value
and customer support, ALPOLIC® & ALPOLIC®/fr is
the perfect material for cleanroom construction.
C H E M I C A L R E S I S TA N C E
ALPOLIC® & ALPOLIC®/fr finishes have resisted attack when tested using the following protocol:Sulfuric Acid @ 50% for 24 hoursNitric Acid @ 50% for 5 hoursHydrochloric Acid @ 32% for 5 hoursAmmonium Hydroxide @ 30% for 24 hoursSodium Hydroxide @ 50% for 24 hoursHydrogen Peroxide @ 33% for 8 hoursAcetone @ 100% for 24 hoursXylene @ 100% for 24 hours
B O N D I N T E G R I T Y
Vertical Pull (C297)Drum Peel (D1781)Flatwise Shear (C273)
ASTMD3359D2794D522D4060D3363
RequirementNo pick-off30 in-lb2T<5.0 mgF/H
Unit
psiin-lb/inpsi
3mm(0.118")190633.61259
4mm(0.157")180633.61225
6mm(0.236")166433.61195
G E N E R A L I N F O R M AT I O N
clean rooms ALPOLIC®/fr PANEL FOR USE AS A CLEANROOM MATERIAL HAS BEEN SPECIFICATION
TESTED IN ACCORDANCE WITH FM APPROVALS TEST STANDARD 4910.
E N G I N E E R I N G P R O P E R T I E S
Aluminum ThicknessSpecific GravityWeightCoefficient of ExpansionThermal ConductanceTensile Yield StrengthTensile StrengthElongationFlexural ElasticityFlexural StiffnessPunching Shear Resistance Maximum Load Shear ResistanceDeflection TemperatureSound Transmission
Unitin–lbs/ft2
in/in/˚FBTU/ft2 hr ˚Fpsipsi%psipsi
lbspsi˚FSTC#
ASTM–––D696C976E8E8E8D790C393
D732D732D648E413
3mm.0201.520.9313 x 10-6
12.298321874712.17.11 x 106
1.04 x 109
18474950231.825
4mm.0201.381.1213 x 10-6
10.756429691313.55.77 x 106
1.99 x 109
19204025231.826
6mm.0201.231.5013 x 10-6
8.534466497817.34.22 x 106
4.98 x 109
21212816231.826
ALPOLIC®/fr Characteristics
CountryUnited KingdomUSA
China
Test StandardBS476, Part6BS476, Part7ASTM E84
Fire Resistance Rating TestsASTM E119Interior Room Corner TestISO9705, UBC26-3Non-toxicity testsNew York State Uniform FirePrevention and Building CodeGB8625, GB8626, & GB8627
Results & ClassificationClass 0Class 1ClearedFlame Spread Index <25Smoke Developed Value <80One-hour Fire-RatingTwo-hour Fire-RatingCleared
Cleared
Cleared B1
F I R E P E R F O R M A N C E
S U R FA C E F I N I S H E SFluorocarbon finishes provide superior smoothness and surface integrity.
ALPOLIC®/fr - FC: Fluorocarbon conductiveALPOLIC®/fr - FN: Fluorocarbon nonconductive
E N G I N E E R I N G P R O P E R T I E S
Aluminum ThicknessSpecific GravityWeightCoefficient of ExpansionTensile Yield StrengthTensile StrengthElongationFlexural ElasticityFlexural StiffnessPunching Shear Resistance Maximum Load Shear ResistanceDeflection Temperature
Unitin–
lbs/ft2
in/in/˚Fpsipsi
%psipsi
lbspsi
˚F
ASTM–––
D696E8E8E8C393
C393
D732D732D648
4mm.0201.901.5613 x 10-6
634471265.05.77 x 106
1.93 x 109
22594637241.8
6mm.0201.812.2313 x 10-6
384042662.04.22 x 106
4.98 x 109
––
228.8
ALPOLIC® PE CharacteristicsS U R FA C E F I N I S H E SFluorocarbon finishes provide superior smoothness and surface integrity.
ALPOLIC® - FC: Fluorocarbon conductiveALPOLIC® - FN: Fluorocarbon nonconductive
F I R E P E R F O R M A N C ETest MethodASTM E-84: Flame Spread Smoke DevelopedASTM E108 (Modified)ASTM D635 (Rate of Burning)ASTM D1929
ASTM E162 (Flame Spread Index)UL-94Modified UBC42-2
Thickness
3/6mm3/6mm4/6mm4mm4mm
6mm3mm3mm
Result
5/015/10PassCC1Flash: 716˚FIgnition: 752˚F11V-O RatingPass
LITAP1020 Rev. 1
Recommended