View
259
Download
0
Category
Preview:
Citation preview
1
Modular Inverter
2
1200VA(960W) 1800VA(1440W) 2500VA(2000W) 3300VA(2640W) 5000VA(4000W)
UNV-F1.2 - UNV-F1.8 – UNV-F2.5 – UNV-F3.3 – UNV-F5.0
| --------------------------------------------------------- 19“ x 3U ------------------------------------------------------------ |
Available input voltages of:
48V DC
60V DC
110V DC
Available output voltages of:
230V AC / 50Hz
[HF Technology 1st Generation]
Modular Inverter Series UNV
3
Modular Inverter Series UNV
UNV-FTechnical information
Input:
Output: 230V, 50 or 60Hz (programmable), single phase
It is possible to build three phase system, each phase with numbers inverter in parallel.
Max. number of inverter working in parallel: 16 pieces
Output power
1,2kVA = 960W 1,8kVA = 1,44kW 2,5kVA = 2,0kW 3,3kVA = 2,64kW 5,0kVA = 4,0kW
Vin 48V 60V 110V 48V 60V 110V 48V 60V 110V 48V 60V 110V 48V 60V 110V
Ain 22,8A 18,2A 9,9A 34,2A 27,4A 14,8A 47,3A 37,9A 20,4A 62,5A 60,5A 26,6A 94,7A 74,9A 39,9A
4
Modular Inverter Series UNV
UNV-FSpecial features
>> Electrical isolation between input and output
>> Input over/under voltage shutdown
>> Hot-plug-in able
>> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 5% INom >> n+x redundancy
>> Ability to build three phase systems with a number of inverters per phase
>> Output overload and short circuit proof
>> Temperature controlled fan cooling (font-to-rear airflow)
>> Digital display for output voltage / current and adjustment of internal default settings
>> Crest factor < 3
>> Can bus interface for communication with static bypass switch and/or monitoring unit
>> Working temperature: -20°C up to +45°C
>> Power factor range: 0,5 ind. - 1 – 0,5 cap.
>> Ability for stand-alone operation
>> Designed to operate together with static bypass switches
>> overload capability 130% for 30sec
5
Modular Inverter Series UNV
UNV-FSignalling
OperationOutput voltage O.K.
High input voltage
Low input voltage
Overload
flashing: ventilator fault
Constant : high internal temperature
Common alarm
Display for output voltage (top line, 3 signs) and output current (second line, 3 signs)
Relay signalling:
Dry contact for common alarm.
Contact rating: 8A@250VAC, 8A@30VDC
6
Modular Inverter Series UNV
UNV-FMounting (mounting kit):
View into a system (left side)
Slide railsPlugs for inverter UNV-F
7
Modular Inverter Series UNV
UNV-FNeeded / available accessories
- mounting kit
>> article number: 880-MEC-MKT.01 (except UNV48-5,0F)
- socket (standard: part of delivery scope)
>> article number: 880-MEC-MKT.21 (except UNV48-5,0F)
>> article number: 880-MEC-MKT.02 (only UNV48-5,0F)
>> article number: 880-MEC-MKT.22 (only UNV48-5,0F)
8
1100W(1375VA) 1600W(2000VA) 4500W(5600VA)
(24V only)
INV211 - INV216 - INV245x
(x=still in development)
|-------------------- 1/4-19“ x 2U ------------------- | ---------------------- 19“ x 2U ------------------------- |
Available input voltages of:
48V DC
60V DC
110V DC
220V DC
Available output voltages of:
230V AC / 50Hz
[HF Technology 2nd Generation]
24V DC
Modular Inverter Series INV
9
Modular Inverter Series INV
INV 222 (INV215@24VDC)Technical information
Input:
Output: 230V, 50Hz, single phase
Max. number of inverter working in parallel: 8 pieces
Output power
INV211 (Still in development)
1,1kW / 1,37kVA
INV216
1,6kW / 2,0kVA
available
INV 222 (Still in development)
1,8kW / 2,2kVA
INV245 (still in development)
4,5kW / 5,6kVA
Vnom 24V 48V 48V 60V 110V 220V 48V 60V 110V 220V
Inom 67,4A 46,8A 46,8A 37,5A 20,8A 10,4A 131,1A 104,9A 58,3A 29,2A
10
Modular Inverter Series INV
INVTechnical information
Signalling: Operation: input voltage within nominal value
Output voltage within nominal value
Common alarm
INV 222 (INV215@24VDC)
Remote signalling:
Dry contact for common alarm. Contact rating 60V/0,1A
11
Modular Inverter Series INV
INV 222 (INV215@24VDC)Special features
>> Electrical isolation between input and output
>> Input over/under voltage shutdown
>> Hot-plug-in able
>> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 10% INom >> n+x redundancy
>> Output overload and short circuit proof
>> Temperature controlled fan cooling (font-to-rear airflow)
>> Crest factor < 3
>> Can bus interface for communication with static bypass switch and/or monitoring unit
>> Working temperature: -20°C up to +55°C
>> Power factor range: 0,5 ind. - 1 – 0,5 cap.
>> Designed to operate together with static bypass switches
>> Overload capability 130% for 5sec; 110% for 1min
12
Modular Inverter Series INV
INVMounting:
Front view of 19” rack
INV 222 (INV215@24VDC)
Mounting angles
Three slots for inverter INV222
Static bypass switch STS207
13
Modular Inverter Series INV216
INVNeeded / available accessories
>> 19” rack, 2 HU, including backplane for 3x inverter + 1x STS
>> article number: 502-222-315.LV (for DC input 24-60V)
>> article number: 502-222-315.HV (for DC input 108-216V)
>> 19” rack, 2HU, with backplane for 4x inverter (without STS)
>> article number: 502-222-405.LV (for nominal DC voltages 24-60V)
>> article number: 502-222-405.HV (for nominal DC voltages 108-216V)
>> Cover plates to cover not used inverter slot, 2HU, RAL7035
>> article number: 881-MEC-BPL.02.21.B
INV 222
14
1000VA(800W) 1800VA(1440W) 2500VA(2000W) 3300VA(2640W) 5000VA(4000W)
PWS-1.0 - PWS-2.5 - PWS-5.0
Available input voltages of:
24V DC
Available output voltages of:
230V AC / 50Hz
Other voltages / frequencies on request
Modular Inverter Series PWS
110V DC
220V DC
Available mechanical design:
19” 4/5U or wall cabinet
15
Modular Inverter Series PWS
PWSTechnical information
Input:
Output: 230V, 50 single phase
It is possible to get special output voltages / frequencies
Max. number of inverter working in parallel: 12 pieces
Output power
1,0kVA = 800W 2,5kVA = 2,0kW 5,0kVA = 4,0kW
Vin 24V 110V 220V 24V 110V 220V 24V not available
110V 220V
Ain 38,8A 8,2A 4,1A 96,6A 20,4A 10,2A 39,9A 20A
16
Modular Inverter Series PWS
PWSSpecial features
>> Electrical isolation between input and output
>> Input over/under voltage shutdown
>> Available as 19” rack or as wall cabinet
>> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 10% INom >> n+x redundancy
>> Crest factor < 2,5
>> Output overload and short circuit proof
>> Temperature controlled fan cooling (font-to-rear airflow)
>> Overload capability 160% for 1min; 130% for 10min
>> Special output voltages / frequencies on request
>> Working temperature: -20°C up to +45°C
>> Power factor range: 0 ind. - 1 – 0 cap.
>> Analogue measurement instruments for output voltage / current
>> Ability for stand-alone operation
>> Designed to operate together with static bypass switches
17
Modular Inverter Series PWS
PWSSignalling
OperationOutput voltage O.K.
High input voltage
Low input voltage
Failure
High internal temperature
Common alarm
Relay signalling:
Dry contact for common alarm.
Contact rating: 5A@250VAC, 5A@30VDC
18
Modular Inverter Series PWS
PWSNeeded / available accessories
- mounting kit
>> article number: 880-MEC-MKT.03
19
Modular Static Switches
20
7kVA@230V AC 14.5kVA@230V AC 30kVA@230V AC 50kVA(1/3phase)
STS207 - STS114 - STS230 - STS350 still in development still in development still in development
|---- 1/4-19“ x 2U ---- | ------------------ 19“ x 1U ------------------ | ---------------------------------------------- 19“ x 3U -------------------------------------------- |
Modular Static Switches Series STS
21
Modular Static Switches Series STS
Technical information
Input:
- Special versions for nominal input voltage of 24-60VDC and 108-216VDC.
- 1x 230VAC bypass mains
- 1x 230VAC inverter output
Output:
- 1x 230VAC, in phase with bypass input
STS
23
STSSignalling
Operation
Inverter input
Bypass input
Load on Mains
Load on Inverter
Synchron bus in phase with bypass mains input
Common alarm
Display of 4 lines
Remote signalling:
Optocoupler for common alarm, Relay on backplane:
Max. contact rating: 30W / 50VA; 60VDC / 125VAC; 1ADC / 1AAC
Modular Static Switches Series STS
CAN-bus Interface
Ethernet Interface
24
Modular Static Switches Series STS
STSSpecial features
>> Hot-plug-in able
>> Display for all main operating parameters, settings and measuring values
>> Ethernet interface for remote connection via SNMP protocol or WEB-Browser
>> Minimized synchronisation time (because of digital PLL) >> It is possible to use diesel gensets as bypass mains
>> Transfer time < 4ms
>> Monitoring of both incoming sources according to voltage level, frequency and synchronisation
>> Temperature controlled fan cooling (font-to-rear airflow)
>> Free programmable operation mode (inverter priority or bypass priority)
>> Overload capability 1000% for 10ms
>> CAN bus interface
25
Needed / available accessories
>> 19” rack, 2 HU, including backplane for 3x inverter + 1x STS
>> article number: 502-216-315.LV (for DC input 24-60V)
>> article number: 502-216-315.HV (for DC input 110-220V)
>> Manual bypass switches (recommended by ELTEK VALERE INDUSTRIAL, please have a look on separate description)
>> article number: 881-880-HBS-7.0 (max. 7,0kVA)
>> article number: 881-880-HBS-14.5 (max. 14,5kVA)
>> article number: 881-880-HBS-30.0 (max. 50kVA)
Modular Static Switches Series STS
STS
26
5000VA 12500VA 23000VA 30000VA 40000VA
UNB-5.0 - UNB-12.5 – UNB-23.0 – UNB-30.0 – UNB-40.0
| --------------------------------------------------------- 19“ x 3U ------------------------------------------------------------ |
Available DC input voltages of:
24 DC
48/60V DC
110V DC
[1st Generation]
220V DC
Modular Static Switches Series STS
27
Static Switches Series UNB
UNBTechnical information
Input:
DC input: Special version for 24VDC, 48/60VDC, 110VDC or 220VDC
AC bypass input: 230VAC, 50/60 Hz, single phase
also available
3x 230/400VAC, 50Hz, three phase with loadable neutral
AC inverter input: 230VAC, 50/60Hz, single phase
also available
3x 230/400VAC, 50Hz, three phase with loadable neutral
Output: 230V, 50/60Hz, single phase, in phase with bypass input
also available
3x 230/400VAC, 50/60 Hz, three phase with loadable neutral, in phase with bypass input
Free programmable operation mode (inverter to load / bypass to load as standard)
28
Static Switches Series UNB
UNBSignalling
Operation
Priority sourceSecond source (substitute source)
Load on Inverter
Load on MainsSynchron bus in phase with bypass mains inputCommon alarm
Display of 4 lines
Relay signalling:
Dry contact for common alarm.
Contact rating: 8A@230VAC, 8A@24VDC
29
Static Switches Series UNB
UNBSpecial features
>> Hot-plug-in able
>> Display for all main operating parameters, settings and measuring values
>> Optional three phase versions
>> Designed for AC systems consisting of UNV- or PWS inverters
>> Transfer time < 4ms
>> Monitoring of both incoming sources according to voltage level, frequency and synchronisation
>> Temperature controlled fan cooling (font-to-rear airflow)
>> Free programmable operation mode (inverter priority or bypass priority)
>> Overload capability 1000% for 10ms
>> CAN bus interface
30
Static Switches Series UNB
UNBNeeded / available accessories
>> mounting kit
>> article number: 880-MEC-MKT.01 (5.0 to 12.5kVA)
>> article number: 880-MEC-MKT.03 (> 23.0kVA)
>> Manual bypass switches (recommended by ELTEK VALERE INDUSTRIAL, please have a look on separate description)
>> article number: 881-880-HBS-7.0 (max. 7,0kVA)
>> article number: 881-880-HBS-14.5 (max. 14,5kVA)
>> article number: 881-880-HBS-30.0 (max. 50kVA)Needed / available accessories
>> socket (standard: part of delivery scope)
>> article number: 880-MEC-MKT.21
31
Other applicable products?
Inverter with built-in static switch UNV-UE series Input: 48/60VDC Output: 230V/50Hz/1000VA outMechanical design: 19” x 3U
32
Other applicable products?
Monoblock inverter
MBI series Input: 110VDC or 220VDCOutput:115VAC or 230VAC
30-50kAV (up to 100kVA at 220VDC)
Mechanical design: stand cabinet in RAL7035
33
Other applicable products?
Monoblock UPS systems
MBS series Input: 3x 230/400VACOutput:1ph. 230VAC or 115VAC
50 or 60 Hz60 up to 100kVA
Mechanical design: stand cabinet in RAL7035
Recommended