1 Common Customer Problem: Op-Amp Output Voltage Swing By Marek Lis Sr Application Engineer Texas...

Preview:

Citation preview

1

Common Customer Problem: Op-Amp Output Voltage Swing

By Marek LisSr Application Engineer

Texas Instruments -Tucson

a0872753

2

Op Amp Output Range Consideration

V3 5

Vout2-

+ +

U2 OPA140

VF2

V1 5

Vout1-

+ +

U1 OPA140

Vos

RF 1kRIN 1k

V2 -2.5

A Valid Op Amp Configuration (Input and Output within the linear range)

An Invalid Op Amp Configuration (Output outside of the linear range)

26.7uV2.5V 171.4mV

171.4mV

3

REAL WORLD Outputs

V+

V+ V+

4

Classic Output Stage

• Common-emitter output• Current source driver• Headroom set by

VBE+VCESAT

• Unity Gain

Q 1

Q 2

V O UT

5

OPA827 – Classic Output

OPA827

OPA827

6

R-to-R Output Stage

• Common Collector or Common Drain

• Headroom set by VDSsat or VCEsat

+V s

R LO AD R LO AD

+V s

-Vs-Vs

7

R-to-R Output Stage

• Common Collector or Common Drain

• Headroom set by VCESAT

• Value of RLOAD affects AOL and Output Swing

+V s

R LO AD R LO AD

+V s

-Vs-Vs

8

MOSFET Characteristic Curves

9

Achieving Output Swing to the Negative Rail

10

SS Pull Down Cheat Sheet

Part # Resistor Value

OPA335 40 kΩ

OPA340 7.5 kΩ

OPA343 7.5 kΩ

OPA348 250 kΩ

OPA350 2 kΩ

OPA353 2 kΩ

OPA333 20 kΩ

11

Thank you