Building the next generation data center

Embed Size (px)

Citation preview

Page 1: Building the next generation data center

1

Page 2: Building the next generation data center

Key Elements of Salient’s Next-Generation Data Center Development include: Redundant Power

Redundant Cooling

State of the Art Security

Flexible Internal/External Network Connectivity

Industry Standards Data Center Certification

Salient eliminates limited and expensive connectivity options by offering Data Center and Fiber Network connectivity in a single package.

2

Page 3: Building the next generation data center

Salient/Minnesota Fiber Exchange is developing a Regional partnership to build a 120 mile last mile, carrier neutral, dark fiber network. The Salient/Minnesota Fiber Exchange Network simplifies direct

connectivity from the Data Center to the end-user.

Carrier Neutral access to the fiber network for licensed, credit worthy providers.

Salient/Minnesota Fiber Exchange maintained Dark Fiber can be lit by Enterprises or Carriers.

Ramsey County Project part of 2012 budget cycle; also in negotiations with Dakota County for access to their fiber assets.

3

Page 4: Building the next generation data center

Increased Carrier capacity reduces cost of bandwidth.

Enables Carriers to serve targeted customers in Ramsey County (and to super-regional locations via inter network connections) from a single point of presence.

Facilitates rapid delivery of Managed Services to an extensive Private and Public sector customer base.

4

Page 5: Building the next generation data center

The Salient Next-Generation Data Center is strengthened through key partnerships:

Kraus-Anderson Construction Company

Parsons Electric

Harris Companies

Hagen Christensen and McIlwain Architects

5

Page 6: Building the next generation data center

Ground-up Facility- Ramsey County Suburbs

Final Site Selection will be aligned with:

Anchor Tenant Requirements

Fiber Network Connectivity

Community Collaboration

Currently working with MN DEED and St. Paul EDA looking at options

Expected Date of Occupancy – Fall 2012

6

Page 7: Building the next generation data center

All Carriers are now interconnect via a single facility within the Minneapolis/St. Paul metro area (511 Building).

A State Task Force* has identified this as a significant liability for our region.

The Salient Data Center + Carrier Hotel strategy brings essential redundancy to our region.

This state of the art facility will serve as a magnet for super-regional connectivity to other population centers in the Central U.S.

* Source: State of Minnesota Broadband Taskforce Report 2009

7

Page 8: Building the next generation data center

Modular 5k to 12k square foot Pods will be available.

Upgradeable Tier 2 and 3 Pods provide increased flexibility to serve selected markets.

Meets both medium and large enterprise requirements.

Each Pod will be electrically isolated from all other Pods.

Salient offers customized Pod services including managed bandwidth and “hands-on” support.

Affords the economies of scale of a larger facility while only leasing the space needed.

8

Page 9: Building the next generation data center

Healthcare

Financial Services

Local, State and Federal Government

Hi-Technology Enterprises

Local, Regional, National and International Carriers

Co-location Wholesalers (Leverage Salient Pod capacity to create retail rack and cage space offerings for Small Business Enterprises)

9

Page 10: Building the next generation data center

Tier 3+ Facility Reference Architectures include:

Uptime Institute Requirements

Facebook Open Compute Project

Combined experience of the Salient Design/Build Team:

Site Specifications

Power

HVAC

Security

10

Page 11: Building the next generation data center

Salient Site +

Upper Midwest limits Data Centers exposure to:

Seismic Activity

Hurricanes

Heavy Tornado Activity

Site Selection Criteria includes:

Out of Flight Path

Significant distance from Railway and Freeway Activity

Outside of Core Downtown areas

Opportunity for Redundant Power Feeds

11

Page 12: Building the next generation data center

Salient Power +

Scalable design with 5,000SF, 7,500SF, and 12,000 SF Pods

150 Watts/SF average

Higher Watt/SF Available

N+1 Centralized power generation, utilizing 2250kw Generators

N+1 dedicated UPS backup per POD

SCADA power monitoring system

Dedicated power distribution system per POD

12

Page 13: Building the next generation data center

Salient HVAC + Concurrently Maintainable Data Center Cooling

All Components Serviceable While Under Maximum Cooling Load

N+1 Chilled Water Plant Robust Perimeter CRCU Fan Gallery No Water Piping In Data Floor 150 W/SF Average Data Floor Cooling Higher Spot Cooling Densities Available Clean Agent Fire Suppression Below Data Floor Double Interlock Pre-Action Fire Suppression For Critical

Spaces Early Warning Smoke Detection To Identify Problems

Before They Start

13

Page 14: Building the next generation data center

Salient Security +

Live Security Staff 24 x 7

Fully Documented Procedures

IP Video Surveillance with Analytics

Man Traps

Audited IP Access Control

Vascular Biometrics

Full RFID Tracking

Explosives Monitoring

Biometric Racks (Optional)

14

Page 15: Building the next generation data center

Currently negotiating for Anchor Tenants for both Data Center and Fiber Network

Additional Anchor Tenant opportunities and pricing are still available

Agent Program allows Technology Firms the opportunity to bring Tenants to the facility and network while receiving a finder’s fee

Check out our booth at the show or contact one of our associates

15

Page 16: Building the next generation data center

John Schultz

612.836.4740

[email protected]

16