37
INTEROCCLUSAL RECORDS Dr Fariborz Vafaee

dr vafaee shlinberg interocclusal records

Embed Size (px)

DESCRIPTION

dr vafaee shlinberg interocclusal records

Citation preview

Page 1: dr vafaee shlinberg interocclusal records

INTEROCCLUSAL RECORDSDr Fariborz Vafaee

Page 2: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Page 3: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

The fingers are placed along the inferior border of the mandible.

Page 4: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

With the thumbs in position, the mandible is manipulat ed into a centric relation position

Page 5: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

The temporomandibular ligament (TML) acts as the posterior limit and fulcrum (F)

The downward force of the thumbs and upward force of the fingers help to seat the condyles in the posterosuperior portion of the glenoid fossa

Page 6: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Template for the baseplate wax arch form.

Page 7: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Baseplate wax is adapted to the maxillary arch.

Page 8: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Cuts are placed between the lateral incisor and canine on each side.

Page 9: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Orientation tabs are folded over the labial surfaces of both canines.

Page 10: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

The cuts between the lateral incisors and canines are extended to remove an anterior wedge.

Page 11: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Excess wax outside the buccal cusp tips is trimmed

Page 12: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Green stick compound is molded to form the anterior programming device.

Page 13: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

The patient holds the programming device in position while the operator manipulates the mandible

Page 14: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

The assembled programmer

and baseplate wax arch form.

Page 15: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

If the mandibular cusp tips do not leave indentations, the thickness of the arch form is increased with Aluwax.

Page 16: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

ONE-QUARTER INCH (6.0-MM) LENGTHS OF BITE REGISTRATION PASTE (A)

ARE MIXED WITH A CEMENT SPATULA (B).

Page 17: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

A small amount of registration paste is placed in each functional cusp tip imprint.

Page 18: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Completed interocclusal record consisting of the occlusal programming device and the paste-corrected wax arch form.

Page 19: dr vafaee shlinberg interocclusal records

CENTRIC RELATION RECORD

Excess registration paste is removed with a sharp knife.

Page 20: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Page 21: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The bite registration form.

Page 22: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The frame is tried in the mouth over the prepared teeth.

Page 23: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Scissors are used to remove any film that overlies unprepared teeth.

Page 24: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The loaded frame is placed over the prepared teeth.

Page 25: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Registration paste is injected over the top and bottom of the bite registration frame.

Page 26: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The record is inspected for completeness and detail.

Page 27: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Registration paste above the edge of the frame is cut off.

Page 28: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Only the imprint of cusp tips should remain on the trimmed record

Page 29: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

Only the imprint of cusp tips should remain on the trimmed record.

Page 30: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The part of the record facial to the mandibular buccal

cusp tips is cut off.

Page 31: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The record on the mandibular cast,

Page 32: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The casts are articulated with the aid of the record

Page 33: dr vafaee shlinberg interocclusal records

MAXIMUM INTERCUSPATION RECORD

The mandibular cast is mounted on the articulator, using the record.

Page 34: dr vafaee shlinberg interocclusal records

LATERAL INTEROCCLUSAL RECORD

Page 35: dr vafaee shlinberg interocclusal records

LATERAL INTEROCCLUSAL RECORD

THE PATIENT IS GUIDED INTO WORKING EXCURSIONS ON THE RIGHT (A). AND LEFT (B) SIDES

Page 36: dr vafaee shlinberg interocclusal records

LATERAL INTEROCCLUSAL RECORD

RIGHT (A) AND LEFT (B) LATER AL INTEROCCLUSAL RECORDS ARE MADE IN WAX WAFERS.

Page 37: dr vafaee shlinberg interocclusal records

LATERAL INTEROCCLUSAL RECORD