APC 3-fāžu UPS izvēles iespējas

ražošanas uzņēmumu vajadzībām

3-fāžu UPS izvēles iespējas

Presented by: Martins Berzins,

UPS Product Manager Baltic Countries

Confidential Property of Schneider Electric

Page 2Confidential Property of Schneider Electric |

Over 50% of failures for critical loads are due to the electrical supply and the

hourly cost of downtime for the corresponding applications is generally

very high.

It is therefore vital for the modern economy, which is increasingly dependent on

digital technologies, to solve the problems affecting the quality and the

availability of the power supplied by the distribution system when it is

intended for sensitive loads

UPSs (uninterruptible power supply) are designed to meet the needs presented

above. First launched in the 1970s, their importance has grown in step

with the development of digital technologies.

UPSs are electrical devices that are positioned between the distribution system

and sensitive loads. They supply power that is much more reliable than the

distribution system and corresponds to the needs of sensitive loads in

terms of quality and availability.

The term UPS covers products with apparent power ratings from a few hundred

VA up to several MVA, implementing different technologies.

.

Purpose of an UPS

What power problem UPS can solve?Power Challenges

Critical equipment

AC: Alternating Current

Power failure Voltage spikes

Over voltage Under voltage

Frequency variations

Harmonics

Power Factor

Back to index

UPS selection

Various UPS protection levels

UPS(20kVA)

Single UPS For Redundancy / Capacity

Module 1

(10kVA)

Modular & Scalable

UPS

Module 2

(10kVA)

Module 3

(10kVA)Pros: Cost efficient, Low footprint

Cons: Service capability, Reliability Pros:

Serviceability, Reliability

Cons: Footprint, Cost,

Pros: Modularity, Scalability, Efficiency,

Serviceability, Reliability

Cons: Higher Cost

UPS A(20kVA)

UPS B(20kVA)

Efficiency

Page 7Confidential Property of Schneider Electric |

Formula:

Annual energy saving = Pu x (1/ŋc - 1/ŋSchneider) x H x C

Pu = kW at UPS output

ŋc = Alternative UPS efficiency

ŋSchneider = Galaxy VM efficiency

H = number of hours in 1 year (8760 hours)

C = kWh price = 0,12 €

Schneider GVM

200 kVA

Alternative

UPS

UPS at 100% load (180 kW) 95,7% 92,0% 79 52€ 23 86€ 1 03 37€ 5 16 86€

UPS at 70% load (126 kW) 96,2% 93,0% 54 14€ 16 24€ 70 39€ 3 51 93€

EfficiencyUPS Energy

saving 1 year

Savings for

cooling (~30%)

Total Savings

1 year

UPS + Cooling

Total savings

5 years

Battery options

Modular batteries by Schneider Led Acid VRLA batteries

• Exide, Yuasa

Lithium-ion Battery

Page 8Confidential Property of Schneider Electric |

Back to index

Li-ion Battery Technology vs. VRLA

Less Footprint

40-60%

Less Weight

60-70%

Expected Life

2-3X

# Cycles

10X

Initial CAPEX

1.5-1.7X

TCO Savings

30-50%

AND

RechargeTime

Faster

Operating Temperature

Higher

BMS Integrated

BMS

Page 9Confidential Property of Schneider Electric |

Double Conversion On-Line Topology• Fully isolates and protects against all power quality

disturbances

Common features across all 3~ UPS range

Page 10Confidential Property of Schneider Electric |

Web base management and LCD display

• Provides remote management of UPS over the

network as well as locally at the UPS

Automatic internal bypass• Fault tolerant design to keep the load running if a

failure occurs

Common features

across all 3~ UPS range

Page 11Confidential Property of Schneider Electric |

Generator compatibility• Ensure continued coverage during generator use

Common features

across all 3~ UPS range

Page 12Confidential Property of Schneider Electric |

Service Contracts• Start-up – INCLUDED with a purchase of a

UPS

• Extended warranty

• Maintenance contracts

Product overview

Page 13Confidential Property of Schneider Electric |

MEDIUM

Single Blok UPS’s

Redundancy N+1

Output PF 0,8 / 0,9

CORE

Single Blok UPS’s

Redundancy or Capacity N+x

Output PF 0,8 / 0,9 / 1,0

PERFORMANCE

Modular & Scalable UPS’s

Internal Redundancy Capability

Output PF 1.0

3-Phase - Performance, Core & Medium offers positioning

Symmetra PX250/500 Symmetra MW

Smart-UPS VT

IT

DatacentersNone-ITIT &

Non-IT

Symmetra PX48 Symmetra PX96/160

Galaxy 5500 Galaxy 7000Galaxy VMGalaxy 3500

Galaxy 300(10-40) Galaxy 300(60-80)

Small to Medium Medium to Large Large to XL

Galaxy VX

3-Phase Product Overview – PERFORMANCE Range(Modular & Scalable, Internal & UPS redundancy or capacity capability, PF 1.0)

500KW

1,25MW

2MW

1MW

300KW

400KW

200KW

100KW

50KW

40KW

30KW20KW

10KW

Small to Medium Medium to Large Large to XL

Symmetra

PX48

(16 to 48kW)

Symmetra

PX96

(16 to 96kW)

Symmetra

PX160

(16 to 160kW)

Symmetra PX250

(25 to 250kW)

Parallelupto 1MW

Parallelupto 2MW

Symmetra PX500

(25 to 500kW)

Parallelupto 4MW

Symmetra MW

(200 to 1600kW)

Scaleable Power Modules: 16kW Scaleable Power Modules: 25kW PM: 200kW

Parallelupto 4MW

Galaxy VX

(1250 & 1500kW)

PM: 250kW

750kW

1,5MW

4MW

500KVA

2MVA

4 MVA

1MVA

300KVA

400KVA

200KVA

100KVA

50KVA

40KVA

30KVA

20KVA

10KVA

Parallel

Up to

4MVA

Galaxy 7000

300,400,500 kVA

Parallel

Up to

720kVA

Galaxy 5500

20,30,40,50,60,

80,100,120 kVA

marine certified

versions

Parallel

Up to

160kVA

Galaxy 3500

10,15,30,30,

40kVA

Parallel

Up to

1MVA

Galaxy VM

160,200kVA

marine certified

versions

Gutor PXC

10,20,30,40,50,

60,80 kVA

marine certified

versions

Galaxy 300

10,15,20,30,40,

60,80 kVA

1KVA

Smart 1p

1,2,3,6,8,10kVA

marine certified

1-6 kVA

Standard / adaptable UPS : Office building or light industry environment type

Parallel Up to

4MVA

Galaxy VX

500,625,750,1000

,1250,1500 kVA

Galaxy VM

Page 17Confidential Property of Schneider Electric |

Galaxy VM

Available in 160kVA & 200kVA

Parallel capability up to 5 units

• High efficiency double conversion UPS

• ECOnversiontm mode capability

• Offers Modular, Classical & Value

battery solutions

• Common battery capability

• Large color touch screen display

• Embedded seismic rating IBC level 2

• Marine certificate

• Intergraded Service Bypass Panel

• Front access servicing

• Top & bottom cable entry as standard

OK Update speaker

Page 18Confidential Property of Schneider Electric |

Galaxy VM 160kVA, 200kVA

Reliable and Fault Tolerant

• Redundant cooling fans, swappable without transfer to bypass

• Robust Static Bypass Switch, 110% continuous load rating

Flexible Energy Storage Options

• Lead Acid

• Li-Ion (Available for Galaxy VX & VM, Symmetra MW, G7000)

• Modular Battery solutions

Facility Friendly

• 7-inch LCD touch screen provides graphical overview of systems

layout, status, alarms, and event history

• Input power factor and harmonics correction, limiting impact on

facility infrastructure

• Smart Power Test (SPoT) for easy commissioning

High efficiency Double Conversion UPS

• >96% efficiency at 30% - 100% load range

• Parallel capability with up to 4 systems in Parallel

• Output Power Factor = 0.9

Multiple Operating Modes – Optimize efficiency

• Double Conversion Mode (up to 96,4% efficiency)

• ECOnversion Mode (up to 99,1% efficiency)

• ECO Mode (up to 99,4% efficiency)

Flexible

• Single or Dual (Dual feed is standard)

• Top and bottom cable entry, no additional hardware

Galaxy VM - Features at a glance

Battery

DC/DC

PFC Recfifier Inverter

LoadAC in

AC in

Bypass Switch

Battery

DC/DC

PFC Recfifier Inverter

LoadAC in

AC in

Bypass Switch

Maybe on to

allow battery

recharge

Battery

DC/DC

PFC Recfifier Inverter

LoadAC in

AC in

Bypass Switch

Double Conversion ECO mode ECOnversion™ mode

Galaxy VX - Double Conversion, ECO Mode & ECOnversiontm comparison

Regulate Voltage

Regulate frequency

Recharge batteries

“No” transfer time

Harmonics & PF Corr.

Efficiency : >96%

Efficiency : >99%

Regulate Voltage

Regulate frequency

Recharge batteries

“No” transfer time

Harmonics & PF Corr.

Efficiency : >96%

Efficiency : >99%

Regulate Voltage

Regulate frequency

Recharge batteries

“No” transfer time

Harmonics & PF Corr.

Efficiency : >96%

Efficiency : >99%

Yes

Yes

Yes

Yes

Yes

No Yes

No

No

No/

Yes

No

No

Yes

Yes

Yes

Yes

No

No

Yes

Yes Yes

Page 19Confidential Property of Schneider Electric |NOTE: Comparison at 50% load

OK

Output Voltage Classification:

• Class 1 (best):

Three classes of UPS output voltage defined by IEC 62040-3:

●Class 2: ●Class 3 (worst):

Battery

DC/DC

PFC Recfifier Inverter

LoadAC in

AC in

Bypass Switch

Battery

DC/DC

PFC Recfifier Inverter

LoadAC in

AC in

Bypass Switch

Maybe on to

allow battery

recharge

On-line mode (double-conversion)

typically obtains class 1 (best)

”Classical” ECO mode typically

only obtains class 3ECOnversion : same class level as

Online Double Conversion

ECOnversion

Com

petito

rE

EC

Onvers

ion

Short circuit on upstream main

Upstream short when system is in ECO Mode

Blue : bypass Voltage

Yellow : bypass Current

Red : Inverter Voltage

Upstream short when system is in ECOnversion

Blue : bypass Voltage

Yellow : bypass Current

Red : Inverter Voltage

Short circuit management

Page 22Confidential Property of Schneider Electric |

Galaxy VM - Smart Power Test (SPoT)

• Circulates power from Inverter, through SBS, into the PFC

• Each component is energized and loaded

• Can test 100% continuous load, or 110% for 10 min

• Inverter operated as current generator in phase with bypass

• PFC draws current to maintain DC bus, and adjust for losses

• UPS draws small amount from utility to adjust for losses

Benefit: UPS Tests without load bank, saves load bank cost

Normal Operation Power Test

Page 23Confidential Property of Schneider Electric |

Galaxy VM - LCD Display 7 inch Display Mimic Diagram Alarms and Logs

• Shows power flow through system

• Shows status of main functions

• Shows current mode of operation - Double Conversion, ECOnversion, ECO

• Intuitive menus

• Downloadable event logs

• Visible Indication of operating mode

• Benefit: Increases Availability and Reduces Human Error

APC tools:

• APC Partner Portal

http://www.apc.com/ee/en/partners-alliances/index.jsp

• Secure Power Industrial selector

http://conf.schneider-electric.com/schneider-electric~cfgui5-spis/index.html

• UPS Selector

http://www.apc.com/ee/en/tools/ups_selector/

• WEB portal for Consultants, Designers, Engineers

http://www.apc.com/ee/en/tools/consultants_designers_engineers/handbook/IE/en/?r=1

• UPS Efficiency comparison calculator

http://www.apcmedia.com/salestools/WTOL-7GKS4S/WTOL-7GKS4S_R3_EN.swf?sdirect=true

THANK YOU.