Upload
bell-flow-systems
View
589
Download
8
Tags:
Embed Size (px)
DESCRIPTION
History and operating principle of electromagnetic flow meters and an overview of Badger Meter's mag meters including technical data and suitable applications for each type from the ModMag range.
Citation preview
Electromagnetic Flow Meters Overview
Type M3000/M4000 / Type M1000
Type II / Type III
Type ModMAG®M2000 / Type B-MAG™ I M5000
Type Food
Faraday´s law states that when a conductor (fluid) moves through a magnetic field of given strength, a voltage is produced.
E = magnitude of the voltageB = magnetic field densityD = pipe diameter v = average velocity of the medium
Electrode
Scoil
Operating principle
.
During the summer of the year 1831
Michael Faraday found the principle of
induction.
Already at that time he tried to
measure the flow velocity of the river
Thames. Unfortunately at that time
without success.
History
.
The first working MAG meter was built in 1939 by the Swiss monk
Bonaventura Thurlemann in the monastery of Engelberg in Switzerland.
History
.
Beginning of the 1950´s a Swiss company recognized the big advantage of the physical law of Faraday for flow metering and gave a research contract to the famous Batelle Institute in Geneva to develop a flow meter based on this basics.
All existing meters on the market are still based on this first construction.
In 1962 the first MAG was delivered to a Swiss water authority.
History
Type Type ModMAG® M1000/1500M1000/1500
Type ModMAG® M2000
Type ModMAG® M3000/M4000
Type B-MAG™ I M5000
Electromagnetic flow meters
.
The low cost alternative
Sizes: DN 6 to DN 200
Accuracy: ±0,5% of actual flow > 0,5 m/s±2,5 mm/s of actual flow ≤ 0,5 m/s
Repeatability: 0,1%
Conductivity: > 5 µS/cm (demineralized water >20 µS/cm)
Flow range: 0,03 - 12 m/s
Flow direction: Bidirectional
Power supply: 24 VDC / 115 VAC / 230 VAC
Display: LCD (4 lines and 16 digits)Blind version M1000
Housing: Powder coated aluminium in IP65
Ambient temp.: -20°C to 60°C
ModMAG™ M1000 / M1500
.
The low cost alternative
Programming: 3 buttons or by RS232 on M1000
In/Outputs: 1 x analog 4 to 20 mA (active/passive)2 x digital out (open collector, active/passive)1 x digital in
Interface: RS232
Empty pipe: Detection by third electrode
Status: Min/Max. alarm, flow direction, error, empty pipe
Preselection: Yes
Low flow cut-of: 0-10%
Remote version: up to 100 m
Detector types: Flange, Wafer, Food
ModMAG™ M1000 / M1500
.
The low cost alternative
Special features: No
Self diagnostic: Yes
Verification device: No
Special approvals: No
ModMAG™ M1000 / M1500
.
Applications
- Water and waste water
- Food and beverage
- Power
- Machines, trucks, OEM
ModMAG™ M1000 / M1500
Type ModMAG® M1000/1500
Type Type ModMAG® M2000M2000
Type ModMAG® M3000/M4000
Type B-MAG™ I M5000
Electromagnetic flow meters
.
The universal meter
Sizes: DN 6 to DN 2000
Accuracy: ±0,25% of actual flow > 0,5 m/s±1,25 mm/s of actual flow ≤ 0,5 m/s
Repeatability: 0,1%
Conductivity: > 5 µS/cm (demineralized water >20 µS/cm)
Flow range: 0,03 - 12 m/s
Flow direction: Bidirectional
Power supply: 85 - 265 VAC / 9 - 32VDC
Display: LCD (4 lines and 20 digits)
Housing: Powder coated aluminium in IP67
Ambient temp.: -20°C to 60°C
Electromagnetic flow meters
.
The universal meter
Programming: 3 buttons (outside)
In/Outputs: 1 x analog 4 to 20 mA (active)4 x digital out (open collector, active/passive)1 x digital in
Interfaces: ModBus® RTU RS232/RS485, HART, Profibus DP, M-Bus
Empty pipe: Detection by third electrode
ModMAG™ M2000
Status: Min/Max. alarm, flow direction, error, empty pipe
Preselection: Yes
Low flow cut-of: 0-10%
Remote version: Up to 100 m
Detector types: Flange, Wafer, Food
ModMAG™ M2000
The universal meter
.
Special features: Parameter backup via memory stick(in process) Data logging
Firmware update via memory stick
Self diagnostic: Yes
Verification device: Yes
Special approvals: No
ModMAG™ M2000
The universal meter
.
Applications
- Water and waste water
- Food and beverage
- Power
- Industrial
- Others
ModMAG™ M2000
Type ModMAG® M1000/1500
Type ModMAG® M2000
Type Type ModMAG® M3000 / M4000M3000 / M4000
Type B-MAG™ I M5000
Electromagnetic flow meters
.
The meter for hazardous areas
Sizes: DN 6 to DN 600
Accuracy: ±0,25% of actual flow > 0,5 m/s±1,25 mm/s of actual flow ≤ 0,5 m/s
Repeatability: 0,1%
Conductivity: > 5 µS/cm (demineralized water >20 µS/cm)
Flow range: 0,03 - 12 m/s
Flow direction: Bidirectional
Power supply: 85 - 265 VAC / 24 VDC
Display: LCD (4 lines and 16 digits)
Housing: Powder coated aluminium in IP67
Ambient temp.: -20°C to 60°C
ModMAG™ M3000 / M4000
.
The meter for hazardous areas
Programming: 3 buttons (inside and by magnetic stick)
In/Outputs: 1 x analog 4 to 20 mA (active)4 x digital out (open collector, active/passive)1 x digital in
Interfaces: RS232
Empty pipe: Detection by third electrode
Status: Min/Max alarm, flow direction, error,empty pipe
Preselection: Yes
Low flow cut-of: 0-10%
Remote version: Up to 100 m
Detector types: Flange
ModMAG™ M3000 / M4000
.
The meter for hazardous areas
Special features: No
Self diagnostic: Yes
Verification device: No
Special approvals: M3000ATEX Zone 2 /FM and CSA Class I Div II
M4000 Div IATEX Zone 1 / FM and CSA Class I Div I
ModMAG™ M3000 / M4000
.
- Chemical industry
- Pharma
- Oil and gas
- Refining
Applications
ModMAG™ M3000 / M4000
Type ModMAG® M1000/1500
Type ModMAG® M2000
Type ModMAG® M3000/M4000
Type B-MAGType B-MAG™™ I M5000 I M5000
Electromagnetic flow meters
.
Sizes: DN 15 to DN 600
Accuracy: ±0,5% of actual flow > 0,5 m/s±2,5 mm/s of actual flow ≤ 0,5 m/s
Repeatability: 0,1%
Conductivity: > 20 µS/cm
Flow range: 0,03 - 12 m/s
B-MAG™ I M5000
Battery-operated water meter
Flow direction: Bidirectional
Power supply: Battery operated / Battery backupBattery life time up to 20 years
Display: LCD
Housing: Powder coated aluminium in IP67
Ambient temp.: -20°C to 60°C
B-MAG™ I M5000
Battery-operated water meter
.
Programming: 3 buttons (outside)
In/Outputs: 4 x digital out (open collector, passive)
Interfaces: ModBus® RTU RS232, IrDA, M-Bus
Empty pipe: Detection by third electrode
Status: Min/Max alarm, flow direction, error,empty pipe
Preselection: No
Low flow cut-of: 0-10%
Remote version: Up to 30 m
Detector types: Flange
B-MAG™ I M5000
Battery-operated water meter
.
Special features: Data logging with real time clock
Self diagnostic: Yes
Verification device: Yes
Special approvals: OIML R49, CEN EN 14154 / ISO 4064, MI-001, MID in process
B-MAG™ I M5000
Battery-operated water meter
.
Applications
- Water and waste water
- Others
B-MAG™ I M5000
Type FlangeType Flange
Type Wafer
Type Food
Electromagnetic flow meters
Flange connections: DIN, ANSI, JIS…. in C-steel or SS
Sizes: DN 6 - 2000
Pressure rates: up to 100 bar
Lining: DN 25 up to 2000 Hard/Soft rubberDN 15 up to 600 PTFEDN 300 up to 1400 HALAR (ECTFE)DN 6 up to DN 10 PFA
Electrodes: Hastelloy C (standard)TantalumPlatinum/Rhodium
Measuring, empty pipe, grounding electrodes
Housing: C-Steel painted or stainless steel
Lay lengths: Badger standard, ISO or customized
Detector - Type Flange
Type Flange
Type WaferType Wafer
Type Food
Electromagnetic flow meters
Flange connections: Sandwich
Sizes: DN 25 - 100
Pressure rates: PN 40
Lining: DN 25 up to 100 PTFE
Electrodes: Hastelloy C (standard)TantalumPlatinum/Rhodium
Measuring, empty pipe, grounding electrodes
Housing: C-steel or stainless steel
Lay lengths: Badger standard
Detector - Type Wafer
Type Flange
Type Wafer
Type FoodType Food
Electromagnetic flow meters
Flange connections: DIN 11851, TriClamp® BS 4825 / ISO 2852
Sizes: DN 10 - 100
Pressure rates: up to 16 bar
Lining: DN 15 up to 100 PTFEDN 10 PFA
Electrodes: Hastelloy C (standard)TantalumPlatinum/Rhodium
Measuring, empty pipe, grounding electrodes
Housing: Stainless steel
Lay lengths: Badger standard
Detector - Type Food
Thank You +44 (0)1280 817304 [email protected] www.bellflowsystems.co.uk
Bell Flow Systems are the UK representative for Badger Meter.